If you still can't figure out the problem with your hot tub, comment below or join our membership group for more detailed help.
@kingtenoffsuit113 күн бұрын
i have no voltage going to the heating element when the spa is calling for heat. resistance and continuity seem fine on the heating element itself. leaning toward a bad relay/, circuit board. would you agree
@VIPPoolsandSpas3 күн бұрын
If there's no error message and everything seems to be flowing fine, then it does sound like a relay problem. Test all fuses and volts coming into spa pack.
@gautamshah4293 Жыл бұрын
Great video! Does the heater manifold need to be disconnected from the circulation pump to do these tests, or can I do them with the spa running?
@VIPPoolsandSpas Жыл бұрын
Yes. In the video I'm testing it live.
@derekparkinson3336 Жыл бұрын
Nice informative video. I have a 5.5 kw not heating. Do you have an element install video?
@VIPPoolsandSpas Жыл бұрын
Thanks. We have many videos on heater element installs. Please go on our channel and you'll find what your looking for. If you can't find it, let me know and I'll give you a link.
@garyhovers2487Ай бұрын
I have checked my element and have 240v, ohm reading is 14.2 for 5.5kw seems to be out of range. I have continuity between post. Any idea what may be going on?
@VIPPoolsandSpasАй бұрын
Whats going on with the hot tub?
@garyhovers2487Ай бұрын
@VIPPoolsandSpas tub won't heat temp staying around 70 degrees.
@VIPPoolsandSpas29 күн бұрын
@@garyhovers2487 change the element
@georgevelarde5323 Жыл бұрын
Thanks for the videos. I replaced my heating element, filled up my tub, but still no heat. Voltage coming into the board is good and all fuses are good, but volts at the element leads are zero, amps zero, ohms zero. Continuity is good. Was I sold a bad heating element or is there something else that is the problem?
@VIPPoolsandSpas Жыл бұрын
Could try replacing the element again.
@danielday23404 ай бұрын
Hello, after changing my heater element and both sensors on my Balboa spa, I still can’t keep my he heater on for more than 90 seconds (est). I hear a click sound sometimes sound which appears the heater has turned off even though it is still showing as being on up top on the panel. If you have any ideas I would be appreciative…
@VIPPoolsandSpas4 ай бұрын
@@danielday2340 test volts coming into the spa pack. Test volts and amps on the heater element.
@RaquelFinkelstein10 ай бұрын
I have a Jandy heat pump EE1500, in the pass it would give me a high pressure error code, and fan wouldn't spin, i would change the condenser for the motor and it would work for about a year, last year it give the same code but this time after changing the condenser it keep showing the same error I have no idea what is going on i change every connection and eerything has power but the heat pump still won't run, any idea what is going on, and A/c tech friend of mine tested the freon lines and said everything is within normal operations he didn't know what was wrong with it either, any help would be appreciated
@VIPPoolsandSpas10 ай бұрын
unfortunately, I don't deal with heat pumps. I always get a heating/cooling guy out to look at them.
@JasonE-kl2ss Жыл бұрын
Spa isn’t heating checked the fuses they are good, checked the voltage it’s good coming in when I go to the element continuity is good on it it reads about 14 ohms, but when I voltage test it’s 0. Does this mean replace the element?
@VIPPoolsandSpas Жыл бұрын
Test the amps on the heater element? Is the circ pump / Pump 1 working fine? Any error codes showing?
@JasonE-kl2ss Жыл бұрын
1 pump and it’s fine, no error codes. Amps are zero, but not super confident that I got a good reading.
@VIPPoolsandSpas Жыл бұрын
@@JasonE-kl2ss Sounds like a relay issue.
@JasonE-kl2ss Жыл бұрын
I have the balboa bp7 spa pack, do you have a video on what relay to check?
@VIPPoolsandSpas Жыл бұрын
@@JasonE-kl2ss I do have videos on how to test a hot tub relay.