Hi Tim, part p electrician here, only recently started watching your channel but enjoying so far. What you’ve done here is not only perfectly legal it is also done to a high standard. The bonding/earthing situation others have referred to is not a problem as the towel rail cannot bring in an earth potential from the water pipes as they’ve been disconnected (and were probably made of plastic further back anyway). The only reason you would need to earth the towel rail is because it is now an electrical appliance, and the earth wire in the element would do that. From a regs point of view these are not new circuits as they’re on a plug so just extended appliances essentially. The only thing I would be concerned with is those crimp connectors, if you use a heavy duty ratchet crimper with the right heads then they’re fine but most others like those wire strippers won’t really be up to it, I’d recommend in line wago connectors if you can fit them in the trunking, if not then redo the crimps with a ratchet crimper. Otherwise very good work and with the smart plugs this setup is actually better in my opinion than hard wiring them in.
@TimAndKatsGreenWalk Жыл бұрын
Cool, thanks for the confirmation, I appreciate it. I'll take a look at getting a ratchet crimper, or else see if I can fit wago connectors. For the record, I did press as hard as I could when crimping those connectors and did a tug test to make sure they were gripping tightly but no harm in getting a better tool for the job.
@classictrafics Жыл бұрын
@@TimAndKatsGreenWalk Yeah, they're probably fine, just something to consider really. The tug test is a good check to do.
@TimAndKatsGreenWalk Жыл бұрын
@@classictrafics I've just ordered myself a ratchet crimper anyway as it looks like another useful tool to have available. I might redo those crimps just be sure. Thanks for the pointer!
@Ben-gm9lo Жыл бұрын
Awesome, some qualified reassurance of a job well done. Tim, perhaps you should try to get a contact for classictrafics. Always useful to have a proper spark to bounce ideas off and you already have him hooked with your content! Ofc this is a fairly futile comment, but comments raise your profile and I too like what you and the lovely Kat do on your channel.@@TimAndKatsGreenWalk
@TimAndKatsGreenWalk Жыл бұрын
@@Ben-gm9lo Haha! Yes, indeed, never hurts to have a qualified person to check with. Prior to starting this project I did research the options as thoroughly as possible to try and ensure I was doing things right, and couldn't find anything to suggest my plan was dodgy in any way, but you can never be 100% sure without professional input, as you say. I'm glad you enjoy the channel.
@boomerang2 Жыл бұрын
from a novice DIY'er i think you did a brilliant job Tim and I'd never be as creative in a solution. Great effort and research. I am having some refurbishment work done on my house and need to have fused spurs installed. A bit annoying that a wifi fused spur is ~£50 but a smart plug like yours is only a tenner! I need 4 including the h/w tank immersion.
@TimAndKatsGreenWalk Жыл бұрын
Ah, I didn't know you could get WiFi fused spurs, that's neat. I guess that saves you needing to find a socket to plug them into. We were lucky that we had some unused sockets in convenient locations that allowed for the smart plug solution.
@hicksonb10 ай бұрын
Did this leveraging this vid, great resource, thanks Tim!! Takes longer to heat up than I thought, circa 30 mins… but stays warm for an hour after turn off. Interest to hear what others are doing for their timings and automations
@TimAndKatsGreenWalk10 ай бұрын
Glad to hear it.
@lyracian Жыл бұрын
Great video (and feeding the algorithm)
@Pablo-tw7tt Жыл бұрын
Nice work Tim. I took a slightly different approach and went for a belt and braces design. As our bathroom is fairly large, I added an additional 700w electric radiator and connected it to the Eddi unit in Hot-water tank cupboard, which conveniently is also in the bathroom. So now I can still heat on gas but if there's surplus solar energy or an Agile price plunge I can take advantage of it as well.
@TimAndKatsGreenWalk Жыл бұрын
Ah, very neat. Theoretically we have a second eddi input we could use for the towel rails but it would mean putting in a whole extra dedicated circuit upstairs, which would be a pain to do, so we decided against that.
@Pablo-tw7tt Жыл бұрын
Agreed. But in the bathroom it was very convenient luckily.@@TimAndKatsGreenWalk
@TimAndKatsGreenWalk Жыл бұрын
@@Pablo-tw7tt yeah, very handy. I'd have certainly done it if it had been that convenient!
@robbiepilot Жыл бұрын
Thanks very much for the demo - will plan to follow your design now.
@TimAndKatsGreenWalk Жыл бұрын
No problem. Good luck!
@David-bl1bt Жыл бұрын
well implemented, well explained.... a good job well done.👍
@TimAndKatsGreenWalk Жыл бұрын
Thank you.
@marks3056 Жыл бұрын
Tidy work, Tim!
@JohnR31415 Жыл бұрын
I’d also add a line of sealant across the top of the blanking plate - drip loop protects from one direction.
@TimAndKatsGreenWalk Жыл бұрын
Yup, fair point.
@paulanderson6903 Жыл бұрын
To be fair the electrical connection is not in the box. That’s just a vanity cover.
@Joe-lb8qn11 ай бұрын
Thanks, I've been considering doing this.
@TimAndKatsGreenWalk11 ай бұрын
No problem. And good luck!
@nicflanagan6662 Жыл бұрын
An interesting project & well executed. Not cold enough yet, in our extension i put in zoned electric underfloor heating. Im looking to test the performance and consumption on the 2-5am element of the Flux tariff. 🤞
@TimAndKatsGreenWalk Жыл бұрын
Yup, I just run our one for half an hour in the off peak period and that dries the towels nicely so far. Don't really need it to heat the room at the moment but we'll see.
@bazcurtis1783 ай бұрын
We have towel rails and they were the only reason we would put the heating on upstairs. The house itself was warm enough. With our new air source heat pump we don’t want the heating on at this time of year (September, October) just for the towel rails. Even if we do turn it on, they aren’t very hot. I was considering getting them converted to electric. You capped off the water pipes, won’t we need to have them still connect to allow water to flow round the rest of the system?
@TimAndKatsGreenWalk3 ай бұрын
No, if you cap off any one radiator/towel rail it won't affect the flow to any of the others. It's a bit like closing the valve to one rad, the rest will still work. In fact you could test it by doing just that in the first instance to be absolutely sure, just close up the towel rail valve and put the heating on to see if the remaining rads get hot.
@bazcurtis1783 ай бұрын
@@TimAndKatsGreenWalk Thanks. I thought that must be the case, but wanted to make sure.
@richardwilson31 Жыл бұрын
Hi Tim, I'm a retired building services engineer. Your installation looks very tidy, I can understand you being happy with what you have done, it looks a very nest jobs but I would like to make some comments on a couple of points that I think you have overlooked, please don't take this to heart. Your trunking looks very neat but I don't like your hidden taped crimped connection, to me the quality of the joint is suspect and could overheat, I think this is why electrical regs call for Wago connectors on hidden connections on mains circuits. Admittedly it doesn't apply in this case but practically it is still a heating circuit drawing a continuous load, it would of been better if the cable could of been replaced in its entirety with no hidden joints between the element and the plug, but that may not of been possible. Your point regarding not overfilling is very important and relevant, expansion must be allowed, however their is no pressure relief valve on this system, should the overheat contactor fail in the element the temperature could rise to boiling point and pressurise the radiator until a joint fails, releasing scalding hot water into the bathroom. I used to work with high pressure systems so my concerns may be excessive but worthy of consideration, Richy
@TimAndKatsGreenWalk Жыл бұрын
Yup, as it happens I have replaced the crimps with wago connectors, although this towel rail is rarely used so it's probably not a huge deal. We only have the main ensuite one on for an hour a day (the others are only used when we have guests), so hopefully also less likely to suffer from overheating, but I'll look into sourcing some pressure release valves just to be sure.
@nubie34 Жыл бұрын
I put in a TCP Smart 500w elec. towel rail, great, but complicated. Aiming to use cheap rate and excess energy for a lovely warm bathroom.
@TimAndKatsGreenWalk Жыл бұрын
Yup, a reasonable alternative.
@MrKlawUK Жыл бұрын
we had electric radiators fitted years ago when we had the bathrooms done as they were never heated before..more recently I had shelly PM1s fitted behind the backbox to act like smart switches but without a plug. Aside from app control manually I also have an automatic humidity control using a wireless thermometer/humidistat (?) - in home assistant so if the humidity hits 80% in the bathroom it'll turn the towel rail on for a couple of hours because that means someone is having a shower.
@TimAndKatsGreenWalk Жыл бұрын
Very neat. One day I'll get around to trying out Home Assistant.
@stevengrace6712 Жыл бұрын
Thanks Tim, will you be sharing any energy consumption data - very intrigued on cost. Also, I know you’re going to get YT hate for the insulating type wrapped crimps in ducting . . Though not a sparky . . I suggest sinking a dry lining back box directly behind here the cable comes through the wall (good for zones too), perform the connections with Wagos or similar maintenance free connectors and then go into the trucking, or fish through the wall. Won’t be as clean looking as your current set-up, but an option if you ever need to switch out the inline connectors/tape situation.
@TimAndKatsGreenWalk Жыл бұрын
For 300 watts I'm pretty happy that this is all good. I will certainly be sharing the data in the stats update videos.
@olej24 Жыл бұрын
Great, I had a quote for £1,050 to do 3 towels rails last week!
@TimAndKatsGreenWalk Жыл бұрын
Blimey. I think this cost me about £200 all in, and that included buying tools that I can use for other projects later. Plus it took a fair while to do, so there's that.
@olej24 Жыл бұрын
My cable runs aren’t as straight forward so I may still need to get an electrician to add some new sockets but the rest of it looks pretty straight forward. Do you have a link to a good video to drain the central heating system?
@TimAndKatsGreenWalk Жыл бұрын
@@olej24 erm, I think I just did a search and watched a couple from different plumbers. Let me see if I can find one.
@TimAndKatsGreenWalk Жыл бұрын
@@olej24 right, apparently I watched this one according to my watch history. Although it turned out to be a bit more complicated for our system and I had to drain each radiator individually, annoyingly: kzbin.info/www/bejne/lZXMc2mCotGJp5Isi=YpYTIVpY-93_e3LN
@nicflanagan6662 Жыл бұрын
Now you know why the electrician's apprenticeship is 5 years .... 1 year theory, 1 year practical & 3 years Offshore and International banking 😅
@terrymackenzie6784 Жыл бұрын
You may want to check with an electrician but I think you may find you need a parent earth connection for metalwork in the bathroom
@TimAndKatsGreenWalk Жыл бұрын
Will do.
@JohnR31415 Жыл бұрын
Yeah, without the pipes hooked up they have no earth any more - though if the elements have a protective earth wired in - you might be ok. Worth getting someone to check the earth.
@TimAndKatsGreenWalk Жыл бұрын
@@JohnR31415 the element definitely has an earth wire but I will get someone to check. I'm thinking if the pipes in the wall are earthed somehow (even though I think they connect to plastic pipes inside the wall) I could put an earth connection between the towel rail and the pipe stumps sticking out the wall?
@Ben-gm9lo Жыл бұрын
I am not a spark, but a keen DIYer with academic qualifications in the matter. Hopefully a Part P spark will see and respond to your question, but if not here is an observation. Such a modern house, your internal pipework will almost undoubtedly be PEX, not copper. Plastic being a poor conductor there would be no point in supplementary bonding (what is being suggested). The towel rail heating element has its own earth, or more pedanticaly Circuit Protective Conductor (CPC), to protect the metalwork of the towel rail from the line connector, or live mains if you prefer. TLDR, what Tim has done is totally adequate. I have the exact same in our en-suite that has subsequently passed an EICR, or safety inspection by a qualified Part P electrician.@@TimAndKatsGreenWalk
@TimAndKatsGreenWalk Жыл бұрын
@@Ben-gm9lo that's good to know. As far as I know the pipes are indeed plastic behind the scenes as all the radiators had plastic pipes.
@JurassicJungle Жыл бұрын
Nice video but I wonder where this stands with Part-P? I appreciate you have wired into a socket in a different room but you had added a new electrical circuit into a bathroom which is a special location which I am not sure is allowed as a DIY under part-P of the building regs.
@TimAndKatsGreenWalk Жыл бұрын
This is a very common setup for towel rails, from what I can tell. I think part P only states you can't plug it in in the bathroom itself (unless the socket is more than 3m away, which would require a huge bathroom!)
@Ben-gm9lo Жыл бұрын
He hasn't added a new circuit, so this is not notifiable work. He has merely added a device on the end of a fused plug, so in the eyes of the regs it is much like plugging in a low powered kettle. Assuming his plug fuse is suitably sized (3 or 5 Amp), then he has taken all the reasonable steps to protect the towel rail heaters.@@TimAndKatsGreenWalk
@TimAndKatsGreenWalk Жыл бұрын
@@Ben-gm9lo yup, it's a fused plug with a 5A fuse.
@FUGDUBED Жыл бұрын
Could you add elements into the radiators in your spare room also??
@TimAndKatsGreenWalk Жыл бұрын
Those radiators are now gone so no, not as it stands! But I believe immersion inserts need to be vertical and those radiators wouldn't have allowed that anyway so they would have needed changing for different ones regardless.
@boomerang2 Жыл бұрын
@@TimAndKatsGreenWalk hi TIm, what makes you think they can only be mounted vertically? I am hoping to fit one (horizontally) to a new cloakroom radiator. Can't find anything online (yet) which suggests can only be vertical, though all the pictures usually show a vertical mount into a towel rail (not radiator). Cheers.
@TimAndKatsGreenWalk Жыл бұрын
@@boomerang2 the instructions that came with the ones I got say they should be installed vertically. You may be able to find specific horizontal ones but most (possibly all?) are designed to work vertically (or at least all the ones I found while looking for towel rail ones).
@TimAndKatsGreenWalk Жыл бұрын
@@boomerang2 a quick Google search reveals specific horizontal ones though for radiators rather than towel rails, e.g. www.justradiators.co.uk/dq-hgt-horizontal-thermostatic-heating-element?ps=OTM9MTE4NTEmMjY1PTE2OTc2&gclid=CjwKCAjwkY2qBhBDEiwAoQXK5SjgOO8CYeDBHiEcU-TgcXZfvqZy7_tvWO8Dt8oqqJSjItI5NcBdMxoC-dwQAvD_BwE#93=11851&265=16976&*CSS+%7C+Generic+%7C+H_P&hsa_acc=5690114029&hsa_cam=11427413721&hsa_grp=120301516748&hsa_ad=474485212742&hsa_src=g&hsa_tgt=pla-332869694290&hsa_kw=&hsa_mt=&hsa_net=adwords&hsa_ver=3
@boomerang2 Жыл бұрын
@@TimAndKatsGreenWalk i also found the same via another website Tim :D Annoyingly they are somewhat more £ than the vertical variety. Does make me wonder if, for similar cost, to have undertile electric heating installed instead (along with the radiator to be solely running via boiler). Would be nice to have toasty feet all year round, in what is a cold cloakroom (north facing). Though my concern here is that it the electric mat will raise the floor height ever so slightly. Much to ponder! Cheers
@JohnR31415 Жыл бұрын
Cable strippers are genius - don’t let all that long if you do a lot of cables, but great for DIY.
@TimAndKatsGreenWalk Жыл бұрын
I should have bought one years ago.
@No3Snow Жыл бұрын
FYI you could wire these in parellel to an eddi as well
@TimAndKatsGreenWalk Жыл бұрын
That would require a separate electrical circuit which would be a bit of a pain to get added. But yes, in principle that could be done.
@stockbullfrog4 ай бұрын
Hi Tim. Just looking at doing this myself so thanks for sharing this knowledge ! Did you have to check your radiators were suitable to be converted or is all that just a bit of a myth? Our case will be with a new bathroom but I prefer some of the designs which come as ‘central heating suitable’. Google is unclear whether there are boundaries on the heat source ….
@TimAndKatsGreenWalk4 ай бұрын
I think pretty much any towel rail will be suitable, as long as an immersion insert will fit.
@paulanderson6903 Жыл бұрын
Question for you…. Would these now run from battery as would want towels warmed BEFORE sun comes up? Would three rads kick the battery hard? As not on cheap elec and not when suns up? Don’t get me wrong I’ve thought about doing something similar too.
@TimAndKatsGreenWalk Жыл бұрын
At the moment I'm running them during the off peak period overnight as that's enough to dry the towels. But yes, they would run from the battery easily. Even if all three were running they would total about 1kW, well within the capability of the inverter/battery. Since we'll also be running our heat pump heating system over winter we'll probably still keep the use of the towel rails to a minimum though. Just enough to ensure the towels are dry.
@paulanderson6903 Жыл бұрын
@@TimAndKatsGreenWalk do like the idea though… and never thought of filling with oil. That said…. Did you put a drain off on them. Like a hose connection?
@TimAndKatsGreenWalk Жыл бұрын
@@paulanderson6903 when I drained them initially I just put a washing-up bowl under one end and undid the bung.
@paulanderson6903 Жыл бұрын
Fair enough
@danielwalls5150 Жыл бұрын
Quick question. Would you pair the immersion with a temperature sensor to operate automatically when it gets colder?
@marks3056 Жыл бұрын
I can answer this ;-) with the givenergy plugs....probably not as the API doesn't allow access. With other smart plugs and home assistant for example, then absolutely (I have sensors and triggers for my home office radiators :-) )
@TimAndKatsGreenWalk Жыл бұрын
Looks like Mark has you covered on that one!
@danielwalls5150 Жыл бұрын
@@marks3056 thanks. Didn’t know givenergy smart plugs didn’t work on the api.
@stevengould2965 Жыл бұрын
Love your videos, but you really need to get an electrician to look at that. I’d be surprised if a straight ‘plug in’ passes regulations.
@TimAndKatsGreenWalk Жыл бұрын
As long as it's not plugged into a socket in the bathroom it's all good, was my understanding. Or if in the bathroom itself the socket needs to be more than 3m away (who has a bathroom that big?)
@lksf98202 ай бұрын
Instead of buying an ASHP why not make all your rads electric like this one?
@TimAndKatsGreenWalk2 ай бұрын
The simple answer is efficiency. Electric radiators convert electrical energy to heat energy with an efficiency of 100%, whereas a heat pump will give you an efficiency of 350%, i.e. you get 3.5x as much heat out as the amount of electrical energy put in (and depending on the system some can be as high as 450+% efficient).