First Time Customers Get 10% Off Their Order With Code " *10%NOW* " At Check-Out Items Used In This Video: 100W Solar Panels: offgridstores.com/products/rich-solar-100-watt-solar-panel-rs-m100 2 To 1 Parallel Connectors: offgridstores.com/products/rich-solar-y-branch-parallel-connectors 50' MC4 Extension Cable: offgridstores.com/products/rich-solar-10-gauge-50-feet-solar-extension-cable-rs-50102
@ronhanish2 ай бұрын
In this solar panel situation do you add The series voltage with the parallel so your total is going to be around 120 I believe? I think the series voltage is around 94, And the parallel voltage down the line is what 32? So total voltage is what 126 volts DC??
@ronhanish2 ай бұрын
In this solar panel situation do you add The series voltage with the parallel so your total is going to be around 120 I believe? I think the series voltage is around 94, And the parallel voltage down the line is what 32? So total voltage is what 126 volts DC??
@ronhanish2 ай бұрын
What I'm trying to say is do I add the parallel circuit voltage with the series circuit voltage question? I'll just check it with a multimeter probably when I hook it up.
@ronhanish2 ай бұрын
So what was your total voltage on this array???
@ronhanish2 ай бұрын
Dude I did it just like you did it. Instead of two panels in series I did three. I had 99 volts. So then I proceed to start paralleling more panels. I got 33 volts. So I'm wondering where my 99 volts went after I went parallel? That's my first question. My second question is the polarity is reversing when I inverted The y adapters. And I checked the voltage and there was zero. So reverse polarity doesn't work. I noticed you guys didn't say anything about it. And the other way doesn't work either. Because it lost my voltage. So now I got to re-figure out what I'm going to do. I'm probably going to parallel everything on the back side at 33 volts and then I'm going to put a couple panels up after that for 99 volts. This is crazy. I don't know what's going on.
@medilax912 ай бұрын
Thanks man... i learn now..
@StansE250 Жыл бұрын
I have Specific use for this information, since my install is limited to TWO panels, whereas most vids deal with arrays larger than Two. I am hopeful to get a Definitive “answer” as to optimizing my Two panel (Van) installation
@LostBoysRecovery Жыл бұрын
Can I do the same thing like this with SAE connectors?
@debbiedogs1 Жыл бұрын
I will be doing parallel with just 2 panels, I think, because the portable power station I want to use 2 panels on when it is cloudy will tolerate only 30 volts for the DC input, and my folding panels are 22 volts, so I cannot do series and double the volts. Now I need to assess whether the MPPT controller in the unit can handle the amps, I guess.
@Van-life-4-Jesus9 күн бұрын
Does it matter where the fuse goes?
@hopeuluv979 Жыл бұрын
Thanks for information.
@jamesdiggs67425 ай бұрын
Love your videos I have a victron 100/50 charge controller trying to get the most watts getting the N-Type 200 w from bougerv is the panel I will have series or parallel and what all do I need please thank you for your time and help
@Rwcheshire10 ай бұрын
I just bookedy the Anker SOLIX F3800. It has 2- 60amp max connection ports. I was going to buy 6 - 400watt panels and run 3 in parallel to each port. Does this sound right? I’m a solar newbe. Panels will be VOC under 60 volts and VMP over 32 volts. Thanks
@Moes_Prep_and_Tech7 ай бұрын
I would that an educated guess and say your 400 panels are over 30 volts each so it would kind of suck for you to put them in parallel, because Unlike this video where he's connecting 2 together in series and then paralleling them in groups of 2. You will have to parallel all of your individually. So you won't go over the 60 volt Voc. (it's a lot of work man and it's gonna look even messier than this video) be prepared to have a lot of extension cables on hand
@alexlindekugel8727 Жыл бұрын
so the more volts you add the lower the amps so can use a small gauge wire? where in par the amps go up alot and need a much larger wire? am i getting this correct?
@camerona.5921 Жыл бұрын
Correct. Low amperage 14-12 gauge solar wire; With amperage higher than 25 amps, go with 12-10 gauge wire
@Moes_Prep_and_Tech7 ай бұрын
Higher Volts are better for Long distance Runs.
@olubunmiadebiyi2988 Жыл бұрын
Which type of connection is preferred. Parallel or series
@debbiedogs1 Жыл бұрын
Totally depends on the system and what amount of amps and volts it can handle. Putting panels in parallel means the AMPS of each panel are added together, increasing the amps going to the system; panels in series add the VOLTS, especially the listed "VOC", so you need to know a bit to assess what to do and why and how. Clearest video I have seen on this is by Jason on his Jasonoid channel, and right now I need only 2 panels combined, which at least makes the math simpler.
@debbiedogs1 Жыл бұрын
Here is the link to Jason's video about what is involved to decide whether series or parallel should or CAN be used. kzbin.info/www/bejne/hYvZo4erna-bjtU
@Moes_Prep_and_Tech7 ай бұрын
I like series but for example if your where to stand in front of one of your panels "ALL" of them would be seriously impacted. it's an all or nothing kind of approach. But less work involved getting it setup. Parallel gives you an insurance plan, They all work together to give you the same results (if your controller can accept the amps it puts out) and when the sun moves and half or part of your array gets shaded the other parts of it with sun on it won't get affected so your still getting power
@flatcirclebob Жыл бұрын
Using 400w panels, could I wire my panels this way to the Ecoflow Delta Pro?
@Moes_Prep_and_Tech7 ай бұрын
depending on the length of the cords. The Panels I have really suck for Parallel, they are just long enough to put in series. So I would need an extension for for like every other connection and that sucks
@joebravokilo8 ай бұрын
i have 4 100W panels , do you recommend doing 2 sets of series and then connecting them in parallel? would that give me 400w's at 11A?
@SirJamez07 ай бұрын
It depends on what you are connecting it to can handle. You just need to sit down and do the math. My River 2 Pro can take 50v 14A max. If you connect x4 of your panels in series, that would be about 80v, too much for my River 2, if you connect all of them in parallel, that would be about 22A, too much for my River 2, however if you connect 2 in series and then both sets in parallel like in this video you would get about 40v 11A, perfect for the River 2 Pro. Connecting in Parallel will also give you more Watts than Series, as long as your controller/device can handle the Amps.
@Moes_Prep_and_Tech7 ай бұрын
are you in a shaded area? If not and if whatever it is your connecting it to can handle the combined Volts (VOC) of them all just go for it. Parallel is great if your afraid of partial shading or if your controller can't handle the volts.
@HansonFishFeeds Жыл бұрын
Thanks so much bro. Please, i have 2 300V panels, 200amp battery and 60amp charge controller. What's the best connection for me?
@RR426368 ай бұрын
do more research
@absolute___zero7 ай бұрын
There are no 300 volt panels on the market. Maximum voltage a panel could produce is 52 Volts, and that only under ideal test conditions in a lab. As for your question, the best connection would be the the one that would give you the lowest voltage for your battery, because the MPPT produces bigger losses for larger voltage difference (for converting from source to destination)
@Jakepp235Ай бұрын
When connecting panels in parallel at what point do you need a fuse? Certain amount of amps?
@Van-life-4-Jesus9 күн бұрын
Always need a fuse
@MEASURETWICE Жыл бұрын
I am about to buy renogy panels and cables in the sale but I am trying to research which AWG to get for the extension cables. No one seems to talk about it. How would I find out which would be needed?
@camerona.5921 Жыл бұрын
Rule of thumb is ALWAYS oversize your wire if you aren't sure. The price difference between 12 gauge and 10 gauge isn't much; So I'd go with 10AWG
@MEASURETWICE Жыл бұрын
Thank you@@camerona.5921
@HansonFishFeeds Жыл бұрын
@@camerona.5921Please bro, which gauge is higher, 12 or 10 awg?
@leeknivek10 ай бұрын
@@HansonFishFeedsthe lower the number the heavier the wire
@HansonFishFeeds10 ай бұрын
@@leeknivekThanks for your response
@DanFreark-ou2ci9 ай бұрын
Clear as mud
@geod3589Ай бұрын
so to simplify, connect all positive to one and all neg to one.
@Robby4Jesus10 ай бұрын
Would like to see 4 in parallel.
@fenwickc22742 ай бұрын
think of the 2 you saw and then double it ......
@edwedwdsdsddsds7 ай бұрын
I dont know much solar panels but if I have two 100 watts solar panels and I get someone to connect them for me in parallel for usage on my solar generator, after connecting them in parallel will I get a total of 200 watts coming from the sun to charge my solar generator? My solar generator has maximum amp of 8.5. If the amps double after connecting in parallel will this damage my solar generator??
@Moes_Prep_and_Tech7 ай бұрын
Volts are Force Fed, Amps is something your generator has control over. So whatever your setup details. Don't go over the VOC (voltage)
@absolute___zero7 ай бұрын
solar generator? first hearing of this. is that a combo of mppt + inverter? if so, what a silly name
@CoolStuff.. Жыл бұрын
cool
@flailhammer5174 Жыл бұрын
What do I do when my solar panel has a Sigle 9v power female end instead of a positive and negative?
@debbiedogs1 Жыл бұрын
What kind of solar panel, sounds like it is built only for one specific system, I guess?
@dennyhounds8102 Жыл бұрын
You make have to cut the female adapter, split the wires and solder copper lugs to them. Then make more wires using lugs tht acts as adapters
@muhammadazamkhankhan442611 ай бұрын
Nice job Please share which connection is best for solar pannels. . perallel or series? I mean to get best solar energy. And also give me both connections in easy way to connect 6 150 watts pannels Thanks I am from pakistan.
@CW-pp7zc4 ай бұрын
You lost me when had four panels.
@augustusmccrae7714 Жыл бұрын
This guy advertised his video as being one that focused on, and explained how to connect two solar panels in PARALLEL. Yet instead of focusing on that specific issue, he starts blabbering so incoherently on his stated topic and keeps switching back and forth between series and parallel that trying to watch this video wound up tying my brain into knots and I finally got so disgusted that I shut the video off. Is this supposed to be a beginner's video how to or is it aimed at people who have 10 or 20 years of experience dealing with solar configurations? I score this video with a major F minus. It did NOT provide me, as newbie to solar, with the answers to the questions that I thought the title would give me. All it succeeded in doing was to confuse me even more than I was when I clicked on the video.
@debbiedogs1 Жыл бұрын
The best beginner video I have seen is by the Jasonoid KZbin channel, he is a clear and organized teacher, very helpful. And isn't typically trying to do a demo video while holding a camera, which is super hard to do!! Here is the link: kzbin.info/www/bejne/hYvZo4erna-bjtU
@adammyles-rn8eh Жыл бұрын
Maybe you should leave it to someone who has a brain this was pretty simple
@HansonFishFeeds Жыл бұрын
You to appreciate him bro.He did the video for free.
@heroesandzeros7802 Жыл бұрын
You sound like you may know what you are doing, maybe you can figure this out. I have 12- 100W 20V 6A panels wired in parallel going to a 1300W GTI. Each panel individually puts out about 21V. At the end of the parallel string, I get 16V without a load. Instead of 60A, I get about 3A. I fused each panel and all fuses are good.
@camerona.5921 Жыл бұрын
Did you diagnose each panel individually? Does one of your panels stay in the shade constantly?
@VictorVictor-hq7ui8 ай бұрын
Maybe buy a tripod for filming?
@9jmorrison11 ай бұрын
Show your array was 1 series and one parallel connection at 24 volts.
@reese9276 Жыл бұрын
OK.. I'm a complete newbie in solar. Should I connect two pairs of solar panels in series ( wired as two sets ) and then parallel or the other way around. I believe the end results are the same with current and voltage but am wondering if the panels being wired parallel and the two pairs joined in series would result in a more stable situation or does it make no difference? Please forgive me as I just really do not know and I'd rather appear stupid than burn up my panels or power station. Thanks in advance for your help. I "WILL" be fusing the panels regardless. I'd rather be safe than sorry. Thanks again !
@christopherallan3464 Жыл бұрын
Sorry.. what is feet exactly???
@offgridprep Жыл бұрын
Length of something it means , 1 foot equals 12 inches example 12 feet equals 144 inches
@jackdolphy89658 ай бұрын
instead of just saying 'you should not connect in parallel. it's just my opinion.' you should explain why Duh!!
@coolproductsidiscovered39393 ай бұрын
It's like you're making this video for children. What do we have over here kids? Oh what do you know we have a male what do we have on this side guys? What do you know it's a female they fit together The colors match!
@Sweepear Жыл бұрын
I’m a total novice. This is so jury rigged that it scares me to death. I need help here and this does nothing for me. The comment before mine says condescending and that is correct.