How to do Goose between ABB and Micom Relay | Goose in PCM600 | Goose Schneider Electric S1 Studio

  Рет қаралды 20,417

Barani Tech

Barani Tech

Күн бұрын

Пікірлер: 36
@bharatlalmali8695
@bharatlalmali8695 3 жыл бұрын
Very nice explanation, Sir please prepare a video on trip block on inrush from micon P642 to C264 using goose communication.
@baranitech
@baranitech 3 жыл бұрын
Will try for you
@somidiraj
@somidiraj 4 жыл бұрын
How to detect if there is any break in FO cable and loss of signal from IED to IED ( when in redundant system, IED still be abale to communicate through another cable)
@baranitech
@baranitech 4 жыл бұрын
i don't know how to find but i will try to get solution for your ans soon.
@haribalankumar4657
@haribalankumar4657 5 жыл бұрын
Awesome.....Can you upload video regarding busbar concept..
@alial-shaibany7571
@alial-shaibany7571 2 жыл бұрын
Thanks
@baranitech
@baranitech 2 жыл бұрын
Welcome
@Vicky-xl7no
@Vicky-xl7no 3 жыл бұрын
Communication mode from micom to abb through fo cable are ethernet how to use that
@baranitech
@baranitech 3 жыл бұрын
we can use fiber optical also.
@clintonthangaraj4250
@clintonthangaraj4250 4 жыл бұрын
You covered in all videos how the GOOSE message is send from ABB,Micom,Siemens relays and GOOSE message is received to ABB, Siemens but GOOSE receiving in Micom relay is not available in any other videos. If possible teach us how to receive GOOSE message in Micom relays.
@baranitech
@baranitech 4 жыл бұрын
soon i will make
@jhonkevincardenasalva8056
@jhonkevincardenasalva8056 4 жыл бұрын
El bloque lógico que une a los bloques "AND - CB Close enable logic" y al bloque lógico "NOT - P543_Block" mostrados en el min 16:22; debería ser un bloque lógico "AND" , no un bloque "OR" , esto debido a lo indicado en el min 1:43 - "block CB close enable".
@baranitech
@baranitech 4 жыл бұрын
@16:22 it should be AND gate . i have done mistake
@CKP27
@CKP27 2 жыл бұрын
Sir make video for c264 GE make and use of CET software
@baranitech
@baranitech 2 жыл бұрын
i will try
@CKP27
@CKP27 2 жыл бұрын
Make video of how can replace p444 relay with old relay mcl
@baranitech
@baranitech 2 жыл бұрын
good topic i will study first and then i will try to make
@choskinwest
@choskinwest 4 жыл бұрын
How to do goose from ABB to micom ? ABB as publish and micom as subscriber?
@baranitech
@baranitech 4 жыл бұрын
create IEC file on micom and import to ABB project file for doing Goose cofiguration
@choskinwest
@choskinwest 4 жыл бұрын
@@baranitech it’s for goose from micom to abb right? I mean how about goose from abb to micom, I’ve tried export cid file from pcm600 for abb and imported to s1 agile for micom subscriber, but it doesn’t work
@baranitech
@baranitech 4 жыл бұрын
@@choskinwest First export micom CID file from mcl and import to IEC on ABB pcm600 do goose send and then export IEC file from abb . this export cid has to import to micom mcl
@choskinwest
@choskinwest 4 жыл бұрын
@@baranitech okay, I’ll try it, thanks
@vennapusavenkatesh5546
@vennapusavenkatesh5546 2 жыл бұрын
Sir I want to learn relay. Basic and all types relay training center please send me location are name of institute
@baranitech
@baranitech 2 жыл бұрын
1. voltech 2.V EQUAL IR
@asgeirnilsen6752
@asgeirnilsen6752 5 жыл бұрын
Useful stuff!
@abhishekkalita93
@abhishekkalita93 5 жыл бұрын
It was really useful. But u have missed some parts where a proper explanation was required for proper understanding by new engineers. But those parts were ruined by the loud background music. Kindly stop the music and explain more things line by line
@mr.biplob3795
@mr.biplob3795 4 жыл бұрын
Sir how make CID file for micom relay and if i want comminicate all relay from ethernet switch how to ip address set please make one tutorial for us.
@465AP
@465AP 5 жыл бұрын
Plz don't add the background music... It's ruining the video
@465AP
@465AP 5 жыл бұрын
@@baranitech can u share the link
@bhupendrasingh0302
@bhupendrasingh0302 Жыл бұрын
Please don't add such irritating music in video 😢
@baranitech
@baranitech Жыл бұрын
sorry
How to Trigger Binary input on relay in pcm600
2:09
Barani Tech
Рет қаралды 10 М.
GOOSE BETWEEN MICOM AND DIGIS | GOOSE BETWEEN P543 & 7SJ64 RELAY
19:14
Wall Rebound Challenge 🙈😱
00:34
Celine Dept
Рет қаралды 19 МЛН
Леон киллер и Оля Полякова 😹
00:42
Канал Смеха
Рет қаралды 4,5 МЛН
7- How to use IEC 61850 Configuration in PCM600
11:19
ABB Learning
Рет қаралды 23 М.
How to connect to a relay to use PCM600 and find its information?
5:41
IEC 61850 Engineering with PCM600 -  Part 1 (Goose Configuration)
13:01
Micom Relay Goose Configuration
13:49
TTL Electrical
Рет қаралды 4,9 М.
Route to IEC 61850 (2016): Client/Server, GOOSE and Sampled Values
28:45