Mistake in kitchen vent - You are not allowed to have vent for sink go around king stud in this situation, the drain should be moved over into framing stud bay so vent can go straight through the roof. Here is an example in the 625 square foot house - kzbin.info/www/bejne/pl6zlnp_d9WZpaM and first part of the video.
@MrMac51509 ай бұрын
Your a contractors hero.
@gregvancom9 ай бұрын
Awesome!!!
@CarolSherwood-we6cn7 ай бұрын
Very well done video. For a building newbie can you explain how your plumbing is not on an outside wall? It seems to me that all garage walls would be outside walls. Thanks!
@emilechap85739 ай бұрын
Great stuff thankyou, for the knowledge. 👍
@gregvancom9 ай бұрын
My pleasure!
@venkatesh22859 ай бұрын
Can you show some videos related TJI framing for roof framing? Also Can you show sone videos full open cantilever carport structure. How the TJI connected to the existing masonry building. Also I have doubt on how to place the TJI in the roof framing where the sliding door opening height is at the height of ceiling level.
@gregvancom9 ай бұрын
I have it my list of videos to make, just don't know when.
@davidassaf62139 ай бұрын
How can you span regular 2x floor joists such a distance? I'm doing a similar project and I see in the tables that even with a 2x12 you can't span more than 18'
@gregvancom9 ай бұрын
I've done it on 20 feet with 2x12 that will be 12 inches on center. Keep in mind to check with local building authorities in your area before building.
@davidassaf62139 ай бұрын
Thank you@@gregvancom
@lokksable9 ай бұрын
Would The same footing on the garage work for the second story? From Southern California