How to install a Combi boiler conversion - Worcester 8000 - Vented boiler to mains pressured system

  Рет қаралды 22,236

Loving Plumbing

Loving Plumbing

Күн бұрын

In this video I explain the process I use when converting a regular vented low pressured central heating system to a mains pressured combi boiler set up.
We will be installing the Worcester 8000 Combi boiler and showing you some of its features.
#lovingplumbing #combiboiler #worcester #plumbing #heating #boiler #gas

Пікірлер: 37
@charliefox6987
@charliefox6987 4 ай бұрын
Great video for learning 👍
@Smart_fix
@Smart_fix 2 жыл бұрын
As new in plumbing field I do appreciate for your informative vid mate well explained and well done 👍🏼🙂♥️
@loving-plumbing
@loving-plumbing 2 жыл бұрын
Thank you very much. I'm glad they are helping .
@sudhiradhikari19
@sudhiradhikari19 2 жыл бұрын
Well done my friend, you tried your best to explain which is very helpful for new bees like me, please keep on making good quality videos like this, really appreciate for your help, thank you.
@loving-plumbing
@loving-plumbing 2 жыл бұрын
Thank you very much. Appreciate the feedback. I'm glad it is helpful . Cheers
@ManojKumar-tm2tz
@ManojKumar-tm2tz 2 жыл бұрын
Thank you for information,very helpful
@dannymatona3506
@dannymatona3506 Жыл бұрын
Excellent video mate.
@loving-plumbing
@loving-plumbing Жыл бұрын
Thank you very much
@nishanckarunatillake3361
@nishanckarunatillake3361 3 ай бұрын
Thanks this is a really nicely done video. Small question is it better to do the flush or power flush before installing the new boiler or after. Just wondering if it is done before (using the old boiler to heat it up), the sediments in the pipes and radiators won’t go through the new boiler
@heatpump8566
@heatpump8566 2 жыл бұрын
Quality boiler that 8000 👍
@paulwilliams5296
@paulwilliams5296 Жыл бұрын
Yeah it will probably have half the Life of the Potterton Neta heat had
@Shah2
@Shah2 Жыл бұрын
Great informative video. Having my two bedroom flat system boiler changed to a combi by the housing association and wanted to get an idea of what will happen on the day. Also what to look out for so no corners are cut. Thanks!
@loving-plumbing
@loving-plumbing Жыл бұрын
Thank you
@Shah2
@Shah2 Жыл бұрын
@@loving-plumbing corners were cut! There were two bottles in the new boiler box. Cleaner and inhibitor Fernox red and blue cap. They were not used. Can they flush the boiler without using them...the rads were drained of water via a hose stuck on water pipe in hallway...I was keeping an eye on the bottles (not watching them constantly, as I don't like that personally in my job) but at the end before they left I felt the bottles and felt they were full , caps still sealed. I think coz of the time needed to flush/clean they didn't do it. The guy working on the boiler did use a spray bottle which I found out is an inhibitor, but boiler was not run for hour whatsoever, maybe just 20mins tops. They felt the rads warm up and bleeded them that's it. You mentioned it was imperative to do it in your vid. I didn't like the fact they didn't do it. I didn't call them out straight away as again I didn't want to tell them how to do their job. So I waited for the inspection next day to mention to the inspector. I told them that the workers didn't use the bottles, they agreed that it should have been done. The paperwork was even filled in ticking the boxes stating that they had used the cleaner and inhibitor. Also they were cheeky enough to stick the stickers from the bottle onto the side of the boiler but without inputting the date used. Why would they do that? Purely to save time? So the boiler breaks down so they are called out more often? I am a housing association tenant. Or is it not imperative? Anyway, the inspector arranged for an operative to attend the next day, I wasn't in but my misus stated all they did was come in and pour a bottle of inhibitor into the Fernox TF1 Sigma Filter. That was it. No cleaner used, no running on full power for 1/2 hour etc. Boiler working fine. But I'm guessing old sludge remains inside rads/pipes. Its probably just going to damage boiler sooner rather than later. Any thoughts?
@lewisconway6431
@lewisconway6431 Ай бұрын
Why do you care? It's not your boiler,you didn't pay for it did you?
@56ty78ui
@56ty78ui 11 ай бұрын
Great vid. Obviously British Gas looked after the boiler and system. Hmmm, I wonder how much they quoted compared to yours. I'm guessing 5-6k!! Robbing b&stards.
@xclusive463
@xclusive463 4 ай бұрын
Can this 35KW sufficiently provide hot water for shower if two people using at the same time? 🤔 or would they need to take turns thanks ?
@charliefox6987
@charliefox6987 4 ай бұрын
great vid, if you were called to install a boiler but the customer was not willing to agree to power flush the system before hand , would you agree to the install ? even tho by default this would make the warranty invalid (I assume) and would you make note of this on the commisioning documents
@loving-plumbing
@loving-plumbing 4 ай бұрын
Power flush is not mandatory. A chemical flush is.
@MrRawMonkey
@MrRawMonkey Жыл бұрын
The Hive can’t modulate the boiler making the boiler not as efficient as it could be.
@JayGasEssex
@JayGasEssex Жыл бұрын
Correctly sized rads with traditional trv’s. Condensing boiler. Normal programmer and room stat. Basic stuff is the best. Why complicate things.
@Mhyykol
@Mhyykol Жыл бұрын
@@JayGasEssex because on/off controls are inefficent
@luic7021
@luic7021 Жыл бұрын
Hey great video ! I’ve got a question for you … I have a small house that is having its plumbing converted to a combi system and I was wondering would it need motorised valves ?
@loving-plumbing
@loving-plumbing Жыл бұрын
Only if you are having more then one heating zone. But usually probably not if converting.
@gezmonder
@gezmonder 6 ай бұрын
Say you have a bath that only gets used twice a year, isn't that effectively a dead leg?
@ShahedAhmed-er4ih
@ShahedAhmed-er4ih 2 жыл бұрын
Nice work. Another channel to keep uo with. What's the brand of pressfit fitting do you use? You mentioned on one of your videos it does both gas and water and cheaper...
@loving-plumbing
@loving-plumbing 2 жыл бұрын
Thank you 👍. I'm pretty sure they are just called Aquagas M-Press fittings. Merchants like Williams have recently started to stock them. Cheers.
@markbooth3804
@markbooth3804 Жыл бұрын
Great video looking at a combo conversion can this system be run with micro bore pipework as my radiators are all micro bore ?
@loving-plumbing
@loving-plumbing Жыл бұрын
I wouldn't recommend it to be honest. Unless the micro bore is already pressurised
@laganas2008
@laganas2008 Жыл бұрын
@@loving-plumbing How can you tell if the microbore is pressurized? I'm in the same boat as the person who asked the question. I have a regular (very very old) boiler with microbore and I don't know what to do for the best. Thanks.
@SamsungJ-wy4iq
@SamsungJ-wy4iq 10 ай бұрын
​@@laganas2008I'm in the sanw boat, did we get an answer to this please 🙏
@cynt1111
@cynt1111 Жыл бұрын
look at all that scrap😃
@syedabbas8786
@syedabbas8786 Жыл бұрын
How can i found out the flow rate my house has, also is there a way this flow rate to the property can be increased by the supplier?
@loving-plumbing
@loving-plumbing Жыл бұрын
Hi. The best way is to get a large measuring jug and run the tap for a minute. This will tell you how many liters per minute you have. Make sure it's from the cold main. I like to use a big tilers bucket. Alternatively you can buy a weir gauge which is a plumbers measuring device. Flow rate generally can't be increased by the supplier but you can upgrade your incoming main size. The minimum you want is a 25mm blue MDPE pipe. Otherwise pumps and accumulation may be necessary
@IWANASLAPTHAT
@IWANASLAPTHAT Жыл бұрын
Nice video, I'm due to have a worcester external boiler fitted very soon My water is also 5bar 25ltr pm, what should my prv be set at taking into account the shower being fitted is a mira maxim dual Digital overhead one.
@loving-plumbing
@loving-plumbing Жыл бұрын
3 Bar is pretty standard I would say. Thanks 👍🏻
@davidlewi1313
@davidlewi1313 5 ай бұрын
Worchester bosch don’t touch them better boilers out there
Worcester Bosch Greenstar 8000 fitted after a full system conversion!
16:23
Hartley heating and plumbing
Рет қаралды 34 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 48 МЛН
I Took a LUNCHBAR OFF A Poster 🤯 #shorts
00:17
Wian
Рет қаралды 15 МЛН
Люблю детей 💕💕💕🥰 #aminkavitaminka #aminokka #miminka #дети
00:24
Аминка Витаминка
Рет қаралды 1,3 МЛН
Another house saved from a combi
9:47
Urban Plumbers
Рет қаралды 146 М.
Combi Boiler From Start To Finish
24:57
Plumb Like Tom
Рет қаралды 26 М.
Is Your Central Heating System Losing Pressure?
6:43
Skill Builder
Рет қаралды 341 М.
System Conversion - Gravity To Pressurised With New Gas Run
23:23
CP Utility Solutions
Рет қаралды 12 М.
System conversion gone wrong!!!
12:44
CP Utility Solutions
Рет қаралды 4,5 М.
Full Plumbing System Conversion | Back boiler to Combi
29:48
Plumb Like Tom
Рет қаралды 13 М.
System Conversion Part 1: Upgrading Your Plumbing To A Combi Boiler
22:55
Blue Bulldog Plumbing
Рет қаралды 8 М.
THIS BOILER IS A BEAST
7:21
Hartley heating and plumbing
Рет қаралды 28 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 48 МЛН