How To Install a Main Water Shutoff | NIBCO Press Fittings

  Рет қаралды 770,121

Everyday Home Repairs

Everyday Home Repairs

Күн бұрын

Пікірлер: 906
@EverydayHomeRepairs
@EverydayHomeRepairs 4 күн бұрын
Press Fitting Crimping Tool: geni.us/IqAJ7o0 NIBCO Press Fittings 1/2" Ball Valve: homedepot.sjv.io/JgnY2 Sharkbite 1/2" Ball Valve: geni.us/3UBlKoE Pipe Cutter Set (includes both sizes used): geni.us/fAhCj Deburring Tool: geni.us/UoL1 NIBCO Ball Valve: Tools Every Weekend Warrior Needs Makita Cordless Drill Combo Kit: geni.us/t7dIA Dewalt Drill Bit Set: geni.us/oFlSl Dewalt Screwdriver Bit Set: geni.us/VDcr Craftsman Screwdriver Set: geni.us/jXqFI Eklind Allen Wrench Set: geni.us/7XfvO Pliers (4-Piece Set): geni.us/RIdx Stanley Utility Knife: geni.us/ndIDa Stanley Tape Measure: geni.us/bUfD1R Studbuddy Stud Finder: geni.us/RySCuVw Johnson Torpedo Level: geni.us/wiLcDY Stanley Hammer: geni.us/bPDk8Wo Buck Bros Wood Chisel Set: geni.us/vk3cpTW Klein Voltage Tester: geni.us/h9Hl Klein Outlet Tester: geni.us/kdBAJ Milwaukee Wire Strippers: geni.us/MdOB Little Giant Ladder: geni.us/fmlmTk DISCLAIMER: This video and description contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
@jdog4534
@jdog4534 2 жыл бұрын
Ive been a commercial plumber since '95. Whenever I'm fitting together anything involving rubber or neoprene, i like to wet all surfaces with soapy water. ..even nohub bands. ..slip nuts, I've never installed these kinds of fittings here in this video, but i would certainly soap them up before making them up. The soapy water makes all the mating surfaces nice and slippery so nothing binds up or gets pinched then it gets tacky as it dries. Anything that ends up inside the pipe rinses right out with ease. Soapy water in a spray bottle is an invaluable asset for any plumber to maintain. It's not just for checking for leaks or when making up rubber connections. Its good for remodels, before soldering around combustible materials, spray down area. Before cutting into wall or pipe, spray area to keep dust to a minimum. The soap makes it spread better, stay wet longer. I use 2 or 3 tablespoonfuls of dawn per bottle. That way, when it gets low, if im not near my supply of soap, I can just add water to what's left and its still soapy enough... Its handy when cutting rubber too.
@floydalbright2129
@floydalbright2129 Жыл бұрын
Great idea or even corn oil would work as long as it's not oil based .
@jdog4534
@jdog4534 Жыл бұрын
@Floyd Albright but corn oil won't dry clean and it won't spray out of a simple spray bottle like soapy water does. ..and it doesn't double as a substance that can be used to check for leaks. ..and you can't add water to corn oil when the bottle gets low and there's no more corn oil.. lol But it might work well tyseal gaskets and ductile iron gaskets..
@RadioRich100
@RadioRich100 10 ай бұрын
This guy doesnt know what hes doing. He a jack of all trades master of none.
@Wow_wow1
@Wow_wow1 9 ай бұрын
@@RadioRich100but better than master of one, right?
@RadioRich100
@RadioRich100 9 ай бұрын
@@Wow_wow1 No
@georgemoomaw9437
@georgemoomaw9437 10 ай бұрын
I am an old school (retired) HVAC technician that has always sweat copper pipe. About 2 years ago I used Pex to install at tankless water heater in my camping trailer and shark bite to run a new water line in the basement of my condo. Although I have had no problems with either. I’m still skittish about these new fangled things. Any more DIY projects I have, I’ll go back to my old ways. The cost of the press fitting crimping tool is enough to prevent me from even trying these fittings. However, your video was certainly educational. Thank you.
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
None of them have been out there or had the track record or history of sweating copper. Everything new is better than sliced bread until the failures start stacking up. I still remember the 'cheap' PVC from the '70's, aluminum wire, and the CPVC stuff ('90's-'00's) that would fall apart if you touch it. And they got that cheap ABS pipe with a sandwiched layer of foam that turns into spaghetti with hot water. Only reason to deviate from what works is to cut time or money.
@chevy16001
@chevy16001 9 ай бұрын
It doesn't save money it just makes people more confident to do repairs. For a plumber that knows exactly what to look for in solder joints that's fine. For people who don't that can cut a pipe deburr clean and press on a SB it is much easier
@vincemajestyk9497
@vincemajestyk9497 8 ай бұрын
@@chevy16001 For production building work it absolutely saves money (time) if you look at how long it takes to plumb a whole house or building. For a home owner, it's a waste, unless you hire a pro plumber.
@rogerpullin8997
@rogerpullin8997 3 жыл бұрын
I bought the Milwaukee 12 volt system, never looked back, if you ever hired a plumber $1000.- $1500 does not go far, most of the plumbing I do is under kitchen sinks, bathroom vanities, crawl spaces, one point to remember the press fittings are one use only, think twice, press once. One thing I will mention if you used a press cap at the end, that is maybe the most expensive press fittings, you could have likely put on another ball valve for just a dollar or two more and had a water heater shut off valve, maybe the cap is shark bite and you can reuse it, I enjoy your videos. When I replace a valve in a tight run like that I cut the valve, which releases the water inside and reduces the mass to heat up, heat and remove the collar left on pipe, wipe off solder, clean pipe, sometimes that half inch of pipe you save, saves a lot of work
@CarlosRodriguez-hb3vq
@CarlosRodriguez-hb3vq 3 жыл бұрын
Yes the ball valve works in either direction, but pay attention to where the handle may be as it swings 90 degrees from on to off. Otherwise you may find it hits another pipe, another valve, the wall, etc
@joepublic2894
@joepublic2894 3 жыл бұрын
I agree,i think he may have turned it around,the nub on the valve is the stop.the way he had it to open it you turn that one clockwise hitting the wall.good catch.
@virtuallyrealistic
@virtuallyrealistic 3 жыл бұрын
Not to be too picky. There are gate ball valves I use in the basement the include a drain port. That has to be positioned to allow the down stream plumbing to drain after the gate valve is off.
@artemiasalina1860
@artemiasalina1860 3 жыл бұрын
It would be great if they made wheel style handles for ball valves. The handles are easy enough to remove and replace. I suppose you could cut a straight handle down so it's shorter when you have no other option due to space constraints.
@danielanasson4713
@danielanasson4713 2 жыл бұрын
@@virtuallyrealistic gate valves are no match for a ball valve, they jam, leak , and any dirt in the line and they wont shut off properly.
@mrcryptozoic817
@mrcryptozoic817 2 жыл бұрын
@@virtuallyrealistic Any contamination will cause the gate to not seat fully. Then the seat erodes. As long as you're going to sweat one of those monsters on, you might as well use a ball valve. He was spending a lot of money to avoid sweating a valve on but even using an extra $25 on materials to practice with, it still wouldn't equal anywhere near the cost of that crimping tool. That is, if you bought, for practice, an extra 1/2" pipe ($20), a ball valve ($12), 8 couplings (97¢ each), solder, and flux, torch and tank, you're only into it about an extra $60. And you have something to start your campfire with.
@scottpalmer2204
@scottpalmer2204 Жыл бұрын
I use that tool all the time on a 50 yr old apartment complex. Love it! No failures.
@antonioramos8088
@antonioramos8088 2 жыл бұрын
I encourage you to keep up with your instruccions, your videos or whatever you call them. You happen to be a great communicator!!!, therefore we are able to understand and review everything you tell us...!!
@fredh54
@fredh54 3 жыл бұрын
I'm an old school DIYer and I would solder all the connections. Even if you have to buy a torch, the cost is a small fraction of other methods and this method has been used successfully for years. To me it's the gold standard.
@tgoodwin06
@tgoodwin06 3 жыл бұрын
Decades not years, otherwise your comment is awesome.
@jessetorres9698
@jessetorres9698 2 жыл бұрын
I Love the Idea, it’s not only is easier it also prevents you from from burning the house . $175.00 is a well worth Investment
@FrustratedBaboon
@FrustratedBaboon 10 ай бұрын
If you are going to burn the house down, then you should not be doing any plumbing work and stick to your day job where you won't hurt anyone or yourself.
@artemiasalina1860
@artemiasalina1860 3 жыл бұрын
I owned six rental units with very old plumbing for about 25 years. Each time an existing globe valve would fail I would replace it with a ball valve (with a drain). I love them. They are very easy to open and close (1/4 turn) and very easy to see if they are closed or open from across a room. My father taught me how to sweat copper pipes when I was a kid, so that's never been an issue for me. Also, I only own close quarters pipe cutters. Once I found them I never bought another set of the regular kind. I use the CQ ones for everything with no trouble.
@spinspinsugar480
@spinspinsugar480 3 жыл бұрын
I prefer the solder method. It's old school but if done correctly will last many years trouble free. Installing the ball valve is the way to go!
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Something tells me personally I will lean towards solder joints longterm but also interested in getting some experience with these press fittings as I have seen so many making the shift.
@mrdan2898
@mrdan2898 Ай бұрын
My last house was over a hundred years old with original soldered plumbing, and not a single leak! With Pro-press they have rubber O-Rings that will fail. Just imagine a whole house with Pro-press installed everywhere and they all randomly start failing! Those in the plumbing industry love the Pro-press, SharkBite's for repeated emergency overtime pay! 🤑
@Jaredcouture12676
@Jaredcouture12676 3 жыл бұрын
That crimp tool looks like a nice quality tool. I have a Milwaukee Force Logic but I like the fact that you can use the fittings without shelling out $2000. There are some places where soldering isn’t safe. No hot work permit and no sprinkler heads going off but for $175. Nice!
@robertpage2023
@robertpage2023 2 жыл бұрын
I have a big, old soldering iron that I use in such cases when I cannot use a flame torch. I've even used soldering coppers in the past with my heater outside. A big 4 lb copper can do 3 or 4 joints before cooling.
@garywalls9041
@garywalls9041 3 жыл бұрын
One other tip, instead of using a Sharkbite Cap in general, I like to use a Sharkbite coupling with a short piece of pex with a plug crimped in. Then when ready to run more pipe, simply remove the PEX and continue with PEX or copper. I've used Sharkbites professionally for 15-20 years (since Cash Acme 2st came out with them), never had a problem.
@victorpayne6586
@victorpayne6586 9 ай бұрын
I've always soldered pipes together. Works well for me.
@cju4300
@cju4300 3 жыл бұрын
I used threaded ball valve with thread-to-solder coupling. Makes it easier to replace the ball valve. Also don't want to spend $190 (tax included) for a crimp tool. Nice video!
@top-notchcontracting2248
@top-notchcontracting2248 2 жыл бұрын
Isn't that a male adapter?
@stevenbernstein1978
@stevenbernstein1978 3 жыл бұрын
I love SharkBite! The ability to easily disassemble fittings to tune projects by making adjustments is worth every penny of the premium cost.
@parkerjohnson1781
@parkerjohnson1781 3 жыл бұрын
😂😂😂. Sharkbites are trash. I make good money taking out sharkbites that leak
@MariuszChr
@MariuszChr 3 жыл бұрын
@@parkerjohnson1781 And this press fittings, kept by friction, sealed with the same O-ring doesn't leak?
@parkerjohnson1781
@parkerjohnson1781 3 жыл бұрын
@@MariuszChr propress fittings are less likely to leak if pressed with a press gun which are expensive and the pipe is properly cleaned and reamed and installed by a professional. Shark bites are usually installed by homeowners,handymen,and shitty plumbers and tend to leak from poor installation. The only time I use shark bites are for isolating and testing leaks on manifolds or temporary repairs. I prefer to solder if I can cuz it's an art to create beautiful joints. Pressing joints saves time which saves money.
@Steve-kl3mo
@Steve-kl3mo 3 жыл бұрын
Soldering a new fitting is pretty simple and a lot cheaper, but this is interesting and looks like a good option.
@TheGuitarman1968
@TheGuitarman1968 2 жыл бұрын
Good video for the most part. However, press type fittings (including Sharkbite) are ok for external pipe connections that can be monitored regularly. Personally, I would never use press fittings inside of walls (yes, I know people do it all of the time). I have seen way too many press fittings leak, even when installed by so-called "professionals." Also sweating (soldering) copper pipe is fairly cheap and easy. Just make sure the pipes and fittings are cleaned and deburred. Use Flux on the pipe and fitting, and apply heat to the opposite side of the solder contact. This will draw the solder into the gaps between the pipes and fittings, properly sealing the connection for many years. Soldering copper pipe takes some practice, but it is a lot cheaper than spending $175 on a crimping tool that you may only use once or twice. Hey, we can't have too many tools though, can we?....lol. Finally, ball valves are great. They are much more durable and convenient (also more expensive) than globe/gate valves. Just don't buy thin metal, cheaply made ball valves, and they will last (almost) forever. When buying ball valves always look for "full-port" ball valves, so you don't lose water volume. What is the point of having a 3/4" pipe if the ball valve only has a 1/2" hole?" Also, water-knock can be an issue with ball valves on an often-used connection (like a garden hose). This is because the opening and closing of the ball valve is instant, and not gradual like with a gate/globe valve. However, this can be overcome by closing the ball valve slowly. This is just my 2 cents on the subject. Hopefully this helps all of those DIYers out there. 👍👍
@zekehu7701
@zekehu7701 2 жыл бұрын
For sure its going to help guys like me who own a home and depend on videos and detailed instructions from guys like you. Well I have to use sharkbite as my shutoff is in-between walls and 12 inches below the basement ceiling. Thanks once again.
@jayak3768
@jayak3768 2 жыл бұрын
Hi, Sorry I haven't heard of press fittings leaking inside walls if done properly.
@mikeos6666
@mikeos6666 Жыл бұрын
@@jayak3768 Those things leak all the time, all the pipes at my work are installed by long term Journeymen plumbers and I see them leaking all the time, slow drips with visible corrosion from where it is leaking.
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
@@zekehu7701 I WOULD NEVER USE A PUSH FITTING VALVE ON THE MAIN SHUT OFF. Your insurance company is gonna love you. There's ALWAYS a way to do it correctly.
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
You are correct. Best to check your jurisdiction. Some ONLY allow a rising stem or gate valve on the main shut off to avoid water hammer or shock from abrupt shut off. The gate valve makes this impossible.
@trianj12
@trianj12 3 жыл бұрын
Have used sharkbites several years on numerous project's. Extremely satisfied with ease of installation. No special tools required. Have used on both copper and plastic type pipes. Never a leak Very convenient for DYI in remote,, tight, or potentially flammable locations. Concur with comments concerning cost of snakebite but considering savings in purchase of and required knowledge in using more sophisticated tools still preferable for average user.
@jwall62
@jwall62 11 ай бұрын
Same here, I have an old leaky main right now that I am cutting out and using sharkbite, 15 minutes start to finish. Cue all the regular plumbers coming in and shitting on sharkbite and pex.
@RadioRich100
@RadioRich100 9 ай бұрын
@@jwall62 There shit dont be lazy.
@jwall62
@jwall62 9 ай бұрын
@@RadioRich100 or they’re so easy anyone can do it and plumbers don’t like that. Showed my wife how to do it and she did it in less than five minutes.
@RadioRich100
@RadioRich100 9 ай бұрын
@@jwall62 Whats she going to do when it starts leaking?
@jwall62
@jwall62 9 ай бұрын
@@RadioRich100 there will probably be better technology in 20 years when it might fail, but we’ll have to wait and see.
@murraymacneill2545
@murraymacneill2545 3 жыл бұрын
There's a lot to said for old school heat and solder joints. Simple and solid.
@justice4all603
@justice4all603 3 жыл бұрын
I'm a plumber and I use pro press and mega press frequently, you did a good job ,but I would have pre fitted it where all I had to do was 2 presses on the wall to eliminate fatigue. It's much easier to sub assemble on a bench or floor then to do a bunch of crimps on a wall, also most jurisdictions require a minimum of 3/4 feed lines to water heaters
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Hi Will thanks for the feedback. Yeah, I was surprised on the 1/2” main.
@stevelovesgod
@stevelovesgod 3 жыл бұрын
@@EverydayHomeRepairs The main is Size according to Water Pressure from the Street., you are suppose to upsize to 3/4 leading to the Hot water Tank.
@danielanasson4713
@danielanasson4713 2 жыл бұрын
I prefer to Silver Solder Copper lines that are hidden. Pipes that are exposed, pipes around a hot water unit for example it's neater and better looking to use a press tool.
@ltsgarage7898
@ltsgarage7898 Жыл бұрын
I’m pretty sure All Jurisdictions require 3/4 pipe into and out. Most codes call for a 3/4 supply no more than 3 fixtures. You have someone in your comments saying code should be 3/4 supply line. Mobile homes don’t have all the same codes as most building codes. I’m really not sure why mobile homes get away with undersized water piping and undersized drain pipes. But they do!!!!
@ltsgarage7898
@ltsgarage7898 Жыл бұрын
Justice, I’ve been a plumbing contractor for Just over 50 years. How about yourself??
@gjurczyc
@gjurczyc 2 жыл бұрын
Love shark bite, just did my entire house from 60 year old Galvanized steel to Copper pipe with shark bite connectors. They are the best!!
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
If you were using those 'Bite' connectors should have just went to PEX. If you're not going to sweat the joints, no point in using copper.
@mrdan2898
@mrdan2898 Ай бұрын
You re-did your entire house!? Shark bites are NOT the best, they are for emergency repairs only! The fitting will fail, it's just a matter of time.
@hassanbazzi3545
@hassanbazzi3545 3 жыл бұрын
The best for me as a homeowner and non professional experience is using the shark bite fitting. Great tool for pros though. Thank you for sharing
@jamesofbmore
@jamesofbmore 2 жыл бұрын
I am not a plumber but needed a water line to a fridge with water and an ice maker in the door, the fridge is in an extension part of the house that is exposed to subfreezing temps. The plumber wanted $2000 to run 13 feet of pipe and valves to the fridge. I did it myself for less than $50, I put in the pipe, shutoff valves, and a place to drain off the water outside so the exposed pipe doesn't freeze, all using shark bite fittings and ball valves. did this over a year ago and still no leaks or frozen pipes. As a truck driver, I did well.
@g.b.5206
@g.b.5206 10 ай бұрын
Plummers are not a profession, they are a crime organization
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
Normally if a plumber quotes you THAT much to do that job, it means they just don't want to do it or be bothered.
@justatorchicli4240
@justatorchicli4240 4 ай бұрын
Too expensive
@mrdan2898
@mrdan2898 Ай бұрын
Yeah, plumbers are especially lately becoming way too expensive.
@kenmazza1766
@kenmazza1766 Жыл бұрын
I bought the same tool .Great video explaining the operation of the tool. Mixing in shrak bite couplings is the best option in tight spaces the shark bite fittings allows 360 turning of the pipe a win win
@eusouocara23
@eusouocara23 2 жыл бұрын
I use shark bite. Have it on my laundry room for my cold and hot water lines inside wall with an access panel. Have been there for 8 years. No leak, no problem. Great video!!
@robing5509
@robing5509 2 жыл бұрын
The shark bite fittings are great for me, as I didn't need to use the torch to fix my leak. Which coincidentally was while trying to fix an outside hose valve! I should of watched your video first. I am so not a plumber, but these make it where I can fix things myself. Thank you
@michaelparkin8216
@michaelparkin8216 3 жыл бұрын
I have a property maintenance company; we use sharkbit all the time "10+ years now", benefits of sharkbit over Brazing or press fittings g is you don't loss pipe length due to removal/replace. Sharkbit is 100% removable, replaceable and reliable.
@OddBall1958
@OddBall1958 Жыл бұрын
Never had a problem with sharkbite's. I'm a builder, 40 yrs, and when these came out it's a super easy repair. Quick and clean and most of all no fire and no expensive tools. Another advantage is going from metal to pvc to pex etc with ease.
@RadioRich100
@RadioRich100 9 ай бұрын
So you put your name and phone number on each one? A plumber worth a damn doesnt use them.
@vincemajestyk9497
@vincemajestyk9497 9 ай бұрын
@@RadioRich100 Normally when someone says 'I'm a builder' = 'quickest, cheapest method'. Once these builders finish the last home and are out of the 'warranty period' they file bankruptcy or dissolve the shell company or LLC....and start all over. Once people start having flooded homes they're long gone. Seen it before.
@RadioRich100
@RadioRich100 9 ай бұрын
@@vincemajestyk9497 Tell the know it all guy that has this channel that.
@pasquarielloanthony
@pasquarielloanthony 3 жыл бұрын
Ya you replaced it! 😀👍 I'm a sharkbite skeptic, but also guilty of using them. I never put them in wall though.
@scota.3898
@scota.3898 3 жыл бұрын
Sharkbite uses plastic and it has not proven how long it will last until the plastic part is disintegrated.
@pasquarielloanthony
@pasquarielloanthony 3 жыл бұрын
@@scota.3898 The plastic bit is only applicable for pex. The pressure bearing part is brass and the seal is an o ring. Crimp fittings use the same type o ring.
@antonioramos8088
@antonioramos8088 2 жыл бұрын
Good tool and great comunicator so that we can learn how to do it ourselves.... Bravo for you
@stevefrawley9756
@stevefrawley9756 3 жыл бұрын
I am a DIY'er who thinks ahead, such as what if I have to change this? I can reflow solder, or release a Sharkbite, but what do you do with these fittings?? Does it permanently deform the pipe to the point it cannot be reworked? Looking forward to a video on that topic...
@DragonBuilds
@DragonBuilds 3 жыл бұрын
Yes, it is permanent. That is why I prefer solder.
@seangilboy6053
@seangilboy6053 3 жыл бұрын
If you're going to rework you a solder joint or this you have to cut the pipe so I don't see it as a big issue. You can do this and not worry about water. If you solder you can have to make sure everything is dray.
@CarlosLopez-te5mj
@CarlosLopez-te5mj 3 жыл бұрын
had the same question....
@randy9886
@randy9886 10 ай бұрын
If you are unable to shut the water off completely, (small dribble) these fittings and press will work great, unlike solder. I have one of these presses and it is well worth the money.
@patrcrnn
@patrcrnn 3 жыл бұрын
Way Better Than Shark Bite for a permanent repair. I try to only use pro press when i can. Haven't had many issues after thousands of connections. The issues where usually due to installer error. Great product overall. First time i have seen a manual version in use. Thanks for the demo!
@TheseusTitan
@TheseusTitan 10 ай бұрын
I used SharkBite four times and they have all worked perfectly. I terminated a .25” copper tube and I have three shutoff, quarter turn valves under the sink. No leaking with any of them. I can see and access all the valves (they’re not behind a wall).
@guloguloguy
@guloguloguy 3 жыл бұрын
WOW!!! THANKS, FOR ALL OF YOUR GREAT, DEMO VIDEOS!!! I JUST GOT MY IWISS CRIMP TOOL, TOO!! ....I'LL BE INSTALLING A REPLACEMENT "TANKLESS WATER HEATER", AS SOON AS IT ARRIVES!!.... (MAYBE IN ANOTHER WEEK).
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Nice, welcome to the channel and best of luck with the install 👍
@edwardberrian6057
@edwardberrian6057 2 жыл бұрын
I'm a chief engineer as many situations come up- for copper piping I only go with old school- sweat fittings it's a solid seal as the solder bonds to both sides of the pipe ( male and female) no slipping no chance of coming loose. In some situations I can see saving time with these press fittings, but in time I can see them leaking. Plus all round fittings and supplies are just so much cheaper. Just my thought....
@bigpapa2689
@bigpapa2689 10 ай бұрын
Job security. I can’t understand sharkbites passing plumbing code when the "bite" part is metal into copper. Electrolysis will eventually eat one or the other dissimilar metals.
@MRCNC1967
@MRCNC1967 3 жыл бұрын
I had the boiler replaced at home and the contractor used this style of compression fittings. They did have to sweat a couple of the connections but 99% were done with cordless crimp tool. I think the time it took them to sweat the couple fittings was longer than the time to crimp the others. Also, with this system there is no flame so way safer from a fire hazard standpoint, especially in tight areas near any framing.
@wayneacguy
@wayneacguy 2 жыл бұрын
i am an old time solder guy thats a excellent video
@garywalls9041
@garywalls9041 3 жыл бұрын
I use pro-press from 1" to 3" large Ridgid corded tool. Heavy, but surprisingly well-balanced and easier to get into spaces than it looks. Works great, primarily for commercial, because it's permanent. Only way to remove is to cut, lose some length of cc oppper. One tip, There's a built-in stop. Just push onto pipe until it stops, unless using a slip repair coupling. The 11/16 for 1/2" is just for planning/measurements.
@bahopik
@bahopik 2 жыл бұрын
I would recommend "round off" the edge of pipe with a sand cloth so you're less likely to damage o ring, and dipping either pipe or fitting into a cup of water also makes it easier to push on
@akalina
@akalina 3 жыл бұрын
I like Sharkbite fittings. They are easy and never had any issues with them being a DIYer.
@sparky687
@sparky687 3 жыл бұрын
I use a similar tool from Vevor and I have used MLCP fittings. For the weekend DIY warrior they are a great tool ...my cost was about £70 ($95), definitely worth it...👍🏻
@James-bv4nu
@James-bv4nu 2 жыл бұрын
For a water heater overflow I think sharkbite is perfect. You can remove the sharkbite and put back when you swap out the water heater. If you solder or propress, you may need new piping every time you get a new water heater.
@jamieminton172
@jamieminton172 3 жыл бұрын
Just watched your globe valve repair and HAD to watch this one. I have PEX tools, NIBCO crimp tools, torch and solder, as well as wrenches. You present a lot of good information and options. This is where I have to showcase the error of your way. NIBCO manufactures some amazing products that I can use all of the tools listed above to install which ever product the customer spec's. This is where contemporary marketing bites us all in the A$$. You repaired a globe valve with a little knowledge, sweat equity and $0.30 worth of materials. That valve is now good for another 50 year run and if maintained will last indefinitely. I commented on that episode. Do not misunderstand, I love 1/4 turn balls for replacements and new installs. You have shown the replacement with a NIBCO 1/4 turn press fit ball valve at a cost of $30.00. Not to mention the "Special Tool" which can be had for $100.00 and change. This valve has no serviceable parts has a rubber O-ring and deforms the pipe. Now here is the rub. 1/2" PEX 1/4 turn ball vlv will run about $6.00 and the tool $40 and no serviceable parts or rubber O-rings. SharkBite or equivalent 1/2" 1/4 turn ball vlv is about $17.00, is reusable, requires no special tool, does not deform the pipe and has no serviceable parts or rubber O-rings. Let me just stipulate that 1/4 turn valves have no serviceable parts. You replaced a functioning serviceable valve with a WAY more expensive and potentially inferior Valve. The jury is still out. Unlike the Quest plumbing of the past that was manufactured using inferior materials, NIBCO has introduced a potential weak point in their "Press Fit" line. Recall the galvanic corrosion on the globe valve and the state of the stem packing and the washer. That corrosion and decay were caused by minerals in the water. The globe valve is infinitely serviceable with new packing, washers and Plumbers Grease. The NIBCO O-ring is NOT serviceable and is subject to the same decay. It may be prolonged by coating the O-ring with Plumbers Grease, this will also aid in installation, but that O-ring WILL eventually FAIL. Ask NASA. Don't be fooled by marketing. A trickle of water started the Grand Canyon, it will level a house!
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Thanks for all the feedback 👍
@alanharris9357
@alanharris9357 3 жыл бұрын
I hardly ever respond in the comments but I agree with Jamie. If it were me, I would have put a male compression fitting on the copper then crimped on a female fitting to the pex line then attached the 1/4 turn PEX ball valve.
@MrJamespeyton
@MrJamespeyton 3 жыл бұрын
Shark bite fittings will also allow the valve or fitting to rotate which you may not want. I would use a crimped coupling to extend the valve away from the wall, then solder a ball valve, because the soldered valve can then be easily replaced if necessary. It’s also a good idea to place a pressure gauge upstream and downstream of your water regulator so that you know how well the regulator is functioning and when it is failing. It will also tell you if your street pressure is too high in which case you might want to use 2 regulators. One of which would be a “step down” regulator. . This would only be necessary if the street pressure exceeds 150 psig. Normally house pressure would be set at about 55 or 60 psig. The higher the street pressure, the shorter the life of the regulator because it must work much harder to maintain house pressure.
@ncooty
@ncooty Жыл бұрын
Or install a valve-switched bypass for the PRV with a gauge downstream of both. That way, it's just 1 gauge and you're prepped to change out the PRV when needed.
@monohydrate2
@monohydrate2 Жыл бұрын
I noticed that too, should have extended the copper pipe before placing the ball valve.
@raymondrobbins9495
@raymondrobbins9495 8 ай бұрын
I used sharkbite fitings on my hot water tank they work great with no leaks after 10 years.
@maxmaximus6671
@maxmaximus6671 3 жыл бұрын
I use a variety and it depends on what it is that may make the job easier. I'll use shark bite fittings on certain applications, and solder on others. I'm kind of liking the crimp fit a little more due to an area on a main water line that just wouldn't clear all the water out. Crimp fittings work well for that because soldering would have been a pain. So, the variety is great for the different scenarios you would encounter.
@banditdog1338
@banditdog1338 2 жыл бұрын
Next time you sweat a pipe that just will not quit dribbling water go get a piece of bread break off a piece roll it into a ball and stuff it into the leaky pipe when the water quits dripping go ahead and solder the joint. It works and the bread breaks down and flushes out the nearest outlet.
@ruraloregon2347
@ruraloregon2347 Жыл бұрын
@@banditdog1338 the father of a friend of mine, showed us that trick back in the 60's. It made total sense and I have made use of it a few times.
@MyLifeThai371
@MyLifeThai371 3 жыл бұрын
We used sharkbite fittings to install my new water heater 15 years ago. They never leaked in the 15 years they were on. I decided to put new ones on when the water heater failed this year, because I'm sure that o-ring will eventually deteriorate in the sharkbite fitting.
@giffordcampbell8199
@giffordcampbell8199 3 жыл бұрын
I am a Jamaican and I like your illustration.
@g.b.5206
@g.b.5206 10 ай бұрын
especially when you just smoke a joint heeee heeee
@kenmore01
@kenmore01 3 жыл бұрын
Hey Scott, I had a house in California which had tubing in the slab. Cheap. The hot water tubing started leaking (of course, maybe a topic for a future video.) Not wanting to jackhammer the slab, I bypassed. My then future (now ex) wife was impressed that I was using a utility knife to cut two slots across all of the walls to re-pipe lol. That job was not fun! I used red Pex and the rings and fittings needed a plier similar to what you have there. It's huge! I still have it. It was 3/4" because I sure wasn't getting more than one plier, and the bits weren't changeable like yours. Man, I had to drill 1" holes in all of the studs and put in steel plates to prevent future people from drilling into the Pex. Did drywall repair, painting, texturing and I surprised myself that it was impossible to tell the difference when I was done. I think that was why she married me, but she divorced me because I couldn't get a job lol. Easy come easy go maybe? Don't know. 😁 The point of this comment is to convey what a pain it is to get those huge clamping pliers into walls or any tight spaces. It worked and I saved having a plumber come out and charge thousands of dollars, so you sweat the stuff you have to do but please repeat to yourself, think of what I'm saving. Of course, not everyone will succeed, so mileage will vary. Anyway, awesome video!! Ken
@barrytanenbaum4157
@barrytanenbaum4157 3 жыл бұрын
Great Video! Never seen this done before, so you taught me a lot. Thanks!
@gregroman6840
@gregroman6840 3 жыл бұрын
Shark bite fittings are great ,those press fittings are hard to use and are not reusable if make a mistake,sharkbites cane used over and over again.i keep some fittings and pipe on hand for emergency repairs. I live in a trailer with the old polybutalane pipe so I get a lot of leaks👍
@G0DeSs76
@G0DeSs76 3 жыл бұрын
I had no idea these fitting existed. I use SharkBites, because I am terrified of soldering-afraid I'll start a fire 🔥🔥🔥. I think I'd like to give these crimp fittings a try...tho, I am kinda a very new fan of PEX and the SharkBite EVOPex fittings...
@survivaldaily12
@survivaldaily12 Жыл бұрын
Just did this at home and surprisingly it did not leak!!!! It was incredible. Let me say… as a girl… it was hard to install but totally worth it!!! 🎉🎉
@DragonBuilds
@DragonBuilds 3 жыл бұрын
I prefer using male adapters and a threaded valve, so it is easier to replace the valve if needed.
@gregroman6840
@gregroman6840 3 жыл бұрын
Yeah I never solder valves
@Kerbros100
@Kerbros100 3 жыл бұрын
I never press or solder valves. I always also use threaded or compression fitting valves. Just better for any future repair because nothing lasts forever.
@DragonBuilds
@DragonBuilds 3 жыл бұрын
@@Kerbros100 Soldered valves are fine since you can remove them.
@Kerbros100
@Kerbros100 3 жыл бұрын
@@DragonBuilds Sure but here in Sweden you need to get the hotwork permit just as you look at the torch. If it wasnt for that i agree with you 100% =)
@guloguloguy
@guloguloguy 3 жыл бұрын
GREAT IDEA!!!.... => VERY SMART!!!
@markmurto
@markmurto 3 жыл бұрын
Pro. 30 years +. North East upstate NY. Never had a shark Bite or equivalent fail, or freeze off. Scores copper good in a freeze, never plows or moves on PEXa. Love them for leak fix when sweat will never work.
@wskripka1
@wskripka1 3 жыл бұрын
You can buy ball valves like you showed with compression fittings . Not the small shutoff valves for faucets and toilet supply .
@andrewhobby8041
@andrewhobby8041 2 жыл бұрын
The propress and Sharkbite fittings or Valves I find best to use when you want to avoid Burning anything, a large home with any water in the line when you need a fast repair done anywhere, and when using sharkbites I always look to see if the O rings are greased properly to avoid a dry connection! Love that you made sure the copper was well cleaned before installing the propress to Prevent leaks! As a 20 yr plumber I prefer Propress over sharkbite When really needed! Besides that I try to solder anything I can
@janiceshrader4297
@janiceshrader4297 3 жыл бұрын
When doing some updating on my daughters home I used shark bite fittings in 21 places as well as shark bite ball valves on all sinks and faucets. I know that the shark bite fittings were pricey, but I had time constraints involved. To spend $175 on that crimping tool would be cost effective only if I were going to be doing a lot more plumbing. I know how to sweat the copper, but the shark bites were so quick. My daughter has lived in her home now over 10 years with no leak issues. And I’ve had to sweat a copper line only once in the last 10 years. So, for me I have to say I loved using the shark bites.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Thanks for the feedback!
@mikecase9365
@mikecase9365 3 жыл бұрын
However sharks have been known to blow off. Had it happen. Now I only use the if ever on an exposed connection.
@DilettanteDon
@DilettanteDon 3 жыл бұрын
@@mikecase9365 I have had 1 inch elbows and couplings on my incoming well water line for 11 years now. When I 1st use them I had one blow off, but only because I didn't understand I would encounter 2 points of resistance during insertion. 1st on the stainless steel teeth and then again at the o ring. Properly deburred pipe inserted to fully seated depth will have zero issues.
@thestranger5971
@thestranger5971 Жыл бұрын
I don't have a lot of plumbing projects, as a home owner, I like Sharkbite very much. Never had anything fail or leak on me. But this is a great video and let's me see that the press fitting option might be a good choice in the future..
@FtanmoOfEtheirys
@FtanmoOfEtheirys 3 жыл бұрын
Isn't the point of using solder so that you can remove the pipes by heating them up? By making a permanent connection, if this ever has to be removed to be replaced you lose some length of your pipe.
@7x779
@7x779 3 жыл бұрын
True.
@parkerjohnson1781
@parkerjohnson1781 3 жыл бұрын
Only with certain fittings though. Only if the it's a 90 or a flex line for a water heater or if you have union fittings that you can remove and sweat the unions off. If you have to replace a tee fitting you can't just sweat the fitting off you still have to chop it out and put a new tee, pipe, and couplings.
@kenmore01
@kenmore01 3 жыл бұрын
No, solder is a more permanent connection (though contains lead but not much.) You can't really replace them. I mean you can cut them out and replace, but it's not just a simple melt and replace. Also, things have to be pretty perfect before soldering, or you just cost yourself hours of messing around. And, of course, many people can't solder.
@artemiasalina1860
@artemiasalina1860 3 жыл бұрын
Some ball valves have a drain on them, just like a globe valve. In that case they are directional. There should be an arrow cast into the brass body showing which way they should be installed to be able to drain the side that gets shut off. Another consideration is the example case is make sure there is enough room for the valve's handle to swing it's full travel. It would suck if you installed the valve only to find out that it's so close to the wall that you can't shut it off!
@AStanton1966
@AStanton1966 Жыл бұрын
Valves with the drain are typically called "waste stop valves."
@blakepeterson1977
@blakepeterson1977 Жыл бұрын
I tried a Sharkbite elbow on a pipe with a (very) little bit of solder on it. It wouldn't bite on the pipe. Then I installed a plastic Nibco(?) fitting on the same pipe, and it worked flawlessly. Several months later, I sweat a copper elbow, sleeping better now. I struggle to sweat valves, so I could justify renting one of those crimping tools.
@dgpuig45
@dgpuig45 3 жыл бұрын
I would have chosen the soft solder route and use a damp rag around the valve to keep the heat in check. However if you have water coming through you can either do the press fit solely on the valve or a compression fitting there but I like mostly solder and don't forget to wipe all solder joins free of flux.
@kenkw5515
@kenkw5515 3 жыл бұрын
Or take some bread and push it into the pipe which will stop the water dripping into your solder area and when done, water will soak bread and be expelled when under pressure! Easy peasy!!
@patrickmorris4335
@patrickmorris4335 2 жыл бұрын
I know I’m a year late but I think it was a great instructional video. I’m not a shark bite user, it’s great for homeowners but as a pro , we sweat and press. My only feed back on pressing is that every failure I’ve found was someone 1. Didn’t clean the pipe well 2. The fitting wasn’t pushed in all the way 3. If you are using a battery pro press machine , the battery wasn’t charged all the way . Press fittings have been a time saver and a liability saver versus using a torch. Press valves are especially helpful in the places that you can’t turn the water fully off or there is a lot of drain down.
@EverydayHomeRepairs
@EverydayHomeRepairs 2 жыл бұрын
💯 can be a life saver for sure 👍 Thanks for the feedback
@kikibellebubba1248
@kikibellebubba1248 3 жыл бұрын
Nice detailed video👏 I encourage you to try soldering, it's much easier than you think, especially if you use flux containing tin.😁 Good job on the tool review, I will consider purchasing the crimp tool.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
For sure, I will be spending a bit more time learning how to solder over the next year. I actually think once I get a little practice from a cost and robustness standpoint solder would be my preferred method.
@kkutube1972
@kkutube1972 3 жыл бұрын
I have used Sharkbite for 17 years for those hard-to-reach places and zero problems so far. I manage our own rental property.
@natshain7746
@natshain7746 3 жыл бұрын
Great Job, One question, if you need to solder (in the future ) of a nearby fitting would this soldering melt the O-ring in the press fitted section?
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Viega, which makes ProPress, offers a bit of guidance for this situation Soldering or brazing near an existing To ensure proper sealing of the soldered/brazed joint and the press connection, a minimum distance between connections must be maintained. When soldering near a Viega ProPress connection, the installer must remain at least three tube diameters away from the connection to prevent damage to the sealing element. When brazing, the installer must remain at least nine tube diameters away from the connection. Refer to Table 3.4. The installer should take precautions to keep the Viega ProPress connection cool. These include: • Wrapping the connection with a cold wet rag • Fabricating solder connections prior to installing the press fitting, making sure the tube has cooled before installing the fitting • Applying “spray type” spot freezing
@bobrappucci683
@bobrappucci683 3 жыл бұрын
That's a very great question my concern exactly I don't know if I want to rely on an o-ring on my copper pipe I do a lot of plumbing repair work hot water heaters and I like to know that it's in there permanently and if it had to be redone you just heat up the soldering clean your pipes again I'm not real happy with it I don't trust shark bites and I don't know if I trust an O-ring
@dr2944
@dr2944 2 жыл бұрын
Looked good. Wish you had saved me time with finding out how long it is guaranteed to last. Thanks, HAGO
@robertmacdonald8447
@robertmacdonald8447 3 жыл бұрын
Shark bites are great, can be used to connect two different types of pipe no problems. Used them when I upgraded my waterheater. Limited space so SB's were the way to go.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Hey Robert thanks for the feedback and with limited space I agree Sharkbite fittings can come in pretty handy 👍
@ckennylin717
@ckennylin717 3 жыл бұрын
I concur. Why have a large expensive specialized tool hanging around after you are done with the renovations? Sharkbite valves also rotate after installation, useful for making your flexible connections look neat and straight.
@TiTi-vo7qn
@TiTi-vo7qn 3 жыл бұрын
Yes, once in winter temperature was very cold outdoor, I got copper pipe broken behind the indoor valve (closed) even though I had drained water out then closed the outdoor valve. It was not good for my basement. I repaired it as the same way you said. Outdoor valve (existing)-- copper pipe (existing in concrete) -- SB coupler - Flex pipe (new) -- new T valve (sharkBite) -- Flex pipe (new) -- SB coupler (new) -- SB valve (new) -- existing copper pipe. By this configuration, before winter, I can respectively close the indoor valve, open outdoor valve, open T valve and drain completely water out (vacuum or air compressor). Finally close outdoor and T valves. No more thermal conduction to my indoor valve :-)
@trianj12
@trianj12 3 жыл бұрын
Also used to install the a new water heater several years ago. No leaks yet!
@rubo1964
@rubo1964 7 ай бұрын
Been using compression fittings on my home without issues. Cheap effective....
@markphillips6154
@markphillips6154 3 жыл бұрын
Use shark bite on replacing a ball valve at the veterinary clinic that I maintain probably seven 810 years ago and it works just fine
@watomb
@watomb 3 жыл бұрын
810 years what your secret on how to live so long :). Guessing you missed the dash 8-10
@vcolet2011
@vcolet2011 Жыл бұрын
Just bought that tool....it feels good to know I can be done that easy...
@marcberm
@marcberm 3 жыл бұрын
I think SharkBite fittings are great. I don't typically like to use them for permanent installs or repairs, but that's not to say they'd be at all unsuitable for that. I think people like to envision them as somehow underperforming or leak-prone, but I just find that's demonstrably (and in my own observation) not the case. There's absolutely no compromise in quality when used properly in normal residential situations. That said, I can totally understand professionals staying away from them based on price alone. A plumber trying to spec a job using all SharkBite fittings would never be able to quote copper competitively. I think the press fittings are a good compromise between traditional sweating and something like SharkBite, and that's probably why so many professionals are moving toward them. People also get set in their ways. It's a whole other "wirenuts vs. push-in vs. wago/lever-nuts" kind of question. Everyone's got an opinion on what's best, but everything still has to pass the same government and professional trade association ratings and tests to meet at least minimum standards.
@joshcowart2446
@joshcowart2446 3 жыл бұрын
I wouldn’t trust them for good reason. 9 times out of 10 they may be fine. However I’ve seen freeze tests that just push them off. Before everyone says “don’t put them in a freeze area”, that’s not how freezing works. Freezing greatly increases the pressure in a system and will damage things not necessarily in the frozen area. When they do these tests and shark bite is the only type of fitting that fails and every other one failed at the pipe then I’ll trust other systems
@garydp9760
@garydp9760 2 жыл бұрын
@@joshcowart2446 so how did shark bite pass minimum standards then?
@joshcowart2446
@joshcowart2446 2 жыл бұрын
@@garydp9760 do minimum standards test for freezing? Lots of things pass minimum standards but aren’t the preferred method I’d use. That’s why they’re minimum standards
@spacejunk2610
@spacejunk2610 3 жыл бұрын
I was hesitate using sharkbites at first but I'm a believer now. Installed several with no failures for about 5 yrs. It is the sharkbite brand that I use. No experience with other similar brands. These were invented in Australia. I still can't figure out how they work so darn good!
@billhandymanbill2775
@billhandymanbill2775 3 жыл бұрын
Excellent video. A couple of things to think about: turning off the water valve at the curb has potential consequences if dirt or sand is in the valve you could snap off the curb water valve and then you have big problem and flood. And in some cases, since the curb water valve maybe town property and they may not want you touching their valve so it is best to call them and have them turn off/on the curb water valve. On the placement of the interior ball valve, make sure you have enough space between the ball valve and the wall to turn the ball valve handle open/closed. The plumbers in my area all use the Nibco method and rarely use the Sharkbite for many personal reasons.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Thanks Bill!
@shadowman3320
@shadowman3320 3 жыл бұрын
In my jurisdiction there is no rule that say you can't use the meter shutoff at the curb. It's a good thing too, since they buried the "homeowner's" shutoff in a concrete pipe that filled up with dirt so you can't even find the valve.
@davidppfitzner
@davidppfitzner Жыл бұрын
I have used the battery operated crimpers and they are indeed very quick and efficient, but they are very expensive. I have been looking at these manual crimpers on eBay for a while, but have been hesitant. Thanks. I will be more inclined to buy one now
@Awkward_Fox
@Awkward_Fox 3 жыл бұрын
I like to keep sharkbite caps on hand in the event of a leak, but prefer soldered joints as it's a dying art, and as a hobbiest, it's a skill I need to maintain
@daviddavenport8064
@daviddavenport8064 3 жыл бұрын
Yes not of us oldschool plumbers left out there there's nothing plum with pex copper you make it level and straight
@parkerjohnson1781
@parkerjohnson1781 3 жыл бұрын
Sharkbites are okay for temporary repairs but nothing permanent
@davidannett3322
@davidannett3322 3 жыл бұрын
yea, thinking of an emergency leak kit, a pipe cutter, some shark fittings of diff sizes. ready to go, just cut and cap; but for real, anything permanent, I don't want to have to worry about future failure, soldered joint can be tested, if its not leaking now, its not going to leak later...... is it?
@jtpappas2161
@jtpappas2161 2 жыл бұрын
I used shark bite ends when I installed a water softener system two years ago. They were easy to use and no issues so far
@arthendrickson4860
@arthendrickson4860 3 жыл бұрын
Ball valve orientation might be important based on clearance for the handle.
@drasco61084
@drasco61084 3 жыл бұрын
Don't want to install it then find out you have to turn it towards the wall two inches away 😂
@lucianprescott8357
@lucianprescott8357 3 жыл бұрын
When it comes to a main water inlet, my biggest problem was dealing with the city water department. The street valve is unique and the city was the only ones allowed to turn it off or on. Took a day off work and called the water department to shut off the water. Three hours later a young kid showed up and couldn't get the street valve closed and had to call a supervisor to help him. At this point, I didn't care if the ball valve cost me $50. I just wanted that valve in the warm house installed and working. Of course this was all happening on a January day and the temperature was 14 degrees outside. I sweated the new ball valve on and again had to call the water department again to have them come out to turn the water back on (another 2 hour wait). All in all, spent an entire day changing out one valve.
@jamesdlin7
@jamesdlin7 3 жыл бұрын
When the o-ring fails, how do you remove the crimped connection to replace it? It seems like you'd have to cut it off again, leaving very little pipe left. I think I'd prefer a compression fitting or a soldered one.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Hey James, yeah you would need to cut the pipe off if there was a failure. Overall only 1 commenter indicated they saw failures in press fittings but we will see if more comments on failures come in as we usually get a wide range of experiences from all over the US / World.
@javeedsultan8484
@javeedsultan8484 3 жыл бұрын
On a new build then definitely a lot quicker and anyone can actually crimp . but as replacement on an existing install definitely wouldn't use them, the fact the vavle needs replacing demonstrates why this jointing method can lead to more issues
@TheDogDad
@TheDogDad 3 жыл бұрын
how long do you think it will take the ring to fail? Press fitting are used across the world in residential and commercial settings with a warranty of 50 years.
@javeedsultan8484
@javeedsultan8484 3 жыл бұрын
@@TheDogDad if you're going to use a crimp joint why not just go straight to solder joint, at least you'll have the ability to desolder the joint without cutting pipe short. Good luck claiming even just 10 years down the line. How do you prove it was installed correctly and by a bonafide plumber just for starters, and for the cost of the joint is it even cost effective to argue the item didn't last the course. Ideal conditions never match real life., Here in the UK plastic pipe push fit fittings are commonly used is used if it can be hidden and copper pipe where pipe is visible
@mountainman4068
@mountainman4068 Жыл бұрын
I am a fading PEX fan . My difficulty is how a PEX connection will spin . For example a ball valve will always face down and move when trying to operate the valve . I work in apartment and nursing home environments . I run into a variety of plumbing styles depending on the age of the pipe I'm working on . I am moving towards using a crimper for PEX , or compression fittings when working with older lines . A common problem has been swelled lines from a winter freeze . The 1/2 copper will need cut at a point where there is no swelling . At that point I lean to PEX and quick connects . PEX has made it easy for me to make a continuous run & avoid in the wall connections . I find that I am choosing material (copper or PEX) and fitting depending on what I am working on and the environment that I am in.
@drasco61084
@drasco61084 3 жыл бұрын
I feel like solder is just so much more secure. Of course, you have to do it correctly.
@picklerix6162
@picklerix6162 3 жыл бұрын
I had tons of pinhole leaks due to flux corrosion inside the cold water pipes.
@Jaredcouture12676
@Jaredcouture12676 3 жыл бұрын
I have a ProPress and it’s completely secure. That’s why all the pro’s are switching over. I still solder sometimes but only on a weekend when the supply houses are closed. Crimp fittings aren’t widely available at the DIY stores. Home Depot doesn’t have them at all but Lowe’s has a very limited stock in some stores. But... you’ll never spend $2000 on a torch and a torch makes equally good joints. Mine comes in handy if there’s no time for a hot work permit, sprinkler heads or the water won’t completely shut off. Last week I couldn’t get the water completely off in an apartment complex and there was a leak. I cut the pipe, shoved a press ball valve on there, crimped it and was able to fix the leak at a leisurely pace 🤣
@chachacheng9380
@chachacheng9380 3 жыл бұрын
My 40 year old house use soldering never leak, why I switch to use something I don't feel comfortable to use ?
@Jaredcouture12676
@Jaredcouture12676 3 жыл бұрын
@@chachacheng9380 The beautiful thing is you don’t have to change. If you do it for a living and find something just as secure that cuts your time in half it’s a no brainer.
@joshcowart2446
@joshcowart2446 3 жыл бұрын
Pro press is great. The only issue I have is we haven’t seen them long term when that o rings begins to degrade.
@deboss6620
@deboss6620 Жыл бұрын
I work as property maintenance for 10 years at the same place. We have many maintenance techs fix leaks with sharkbite fittings. As the years go by, more and more leaks seem to pop up. All due to Shark bites started leaking. We have plumbers come out fix them properly. They all say the same thing. The see slot if Shark bites leak after 3-5 years due to hiw bad the hard water in our area is. I seen pro press and it worth investing in the tools. Simple to do and use. Plus saves alot of time then soldering. Recommend saving up for it if you do properly maintenance maintenance. It a live save. We can fix our pipes and not have to pay over price plumber to come out, and do job in 30mins or less with pro press fittings.
@BloodAsp
@BloodAsp 3 жыл бұрын
I prefer soldered pipes. It is stupid simple, cheap, will last forever, and is a transferable skill.
@machintelligence
@machintelligence 3 жыл бұрын
A possible advantage of sweat fit copper is that the joint can be unsoldered cleaned and resoldered with no loss of pipe length. OTOH this system looks like it could be used on a line with a persistent drip, which would make soldering difficult at best.
@richardgallagher70
@richardgallagher70 3 жыл бұрын
Very good presentation. But why re-invent the wheel. Just solder it, so much easier. Less costly.
@jimpie231
@jimpie231 3 жыл бұрын
@@machintelligence I also solder, but never reuse fittings. This makes it faster and easier, no leaks. I also buy at least a couple more of each fitting, thereby not having to go back to the store, because I was a fitting short no matter what the reason. I taught a soldering class in the 80’s at work, a gal learned how to solder in 5 minutes. Thanks.....Jim PS.....soldering tip.......clean all pipe and fittings, even if new, till they shine!
@CarlosRodriguez-hb3vq
@CarlosRodriguez-hb3vq 3 жыл бұрын
@@machintelligence One trick around this is to stuff bread in the pipe to temporarily stop the drip while you solder. When you turn the pressure back on, the bread gets blown through the pipes and obliterated
@blessdunn
@blessdunn 3 жыл бұрын
They took the skill out of the trade, everybody a Turd Herder nowadays
@JW77
@JW77 Жыл бұрын
Not having to drain the water in the pipes is what I like the most about this type of fitting.
@DireNeeds
@DireNeeds 3 жыл бұрын
I like to install a ball valve so when it's open the handle points in the direction of water flow.
@davidg5629
@davidg5629 3 жыл бұрын
I rarely use Sharkbites, but thank God they exist. A Sharkbite coupling just saved me a lot of pain this week. I try to put them in a place in the line where they will be trapped in place, and never use them to cap a live water line. Not permanently, anyway. I'll probably increase my stock of them in the future. Better to have it and not need it, than to need it and not have it. Cheers.
@shahsmerdis
@shahsmerdis 3 жыл бұрын
Cool didn't know they made that but you might be able to find a rental for the press tool
@vake506
@vake506 3 жыл бұрын
👍👍using the nibco press fitting is much simpler and quicker than sweeting copper pipes. I used the shark bite fittings on my hot water heater and It worked very well. I will switch to the nibco press fitting.🇬🇾🇬🇾🇬🇾🇬🇾
@dustintunis9347
@dustintunis9347 3 жыл бұрын
Simpler yes, but it's not much quicker at least not with 1/2" pipe
@50srefugee
@50srefugee 2 жыл бұрын
As always, great presentation. One question: the original installation had a U-loop off to to your right immediately after the shut-off valve. Your preassembled replacement piping did not include this U. I wonder if the U was intended to relieve thermal expansion or water hammer stress on the fittings.
@tomschwartz4853
@tomschwartz4853 3 жыл бұрын
I would suggest calling the city to turn the water off at the street as if you somehow wreck the underground valve you maybe responsible where the city know better. Not sure if there is a charge for that depending on the municipality. Something we did with press fit, is when the fitting is fully engaged mark it with a marker to make sure it does not slip out on you. If so you know. Otherwise nice job and advice. I like the way you put the vice grips on the pipe to hold it out of the wall for the press.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Thanks for the feedback Tom and calling the city/water company is probably the best bet for most people especially with the sensors commonly found in the water box now.
@MarsMan1
@MarsMan1 3 жыл бұрын
Sweating the copper is not difficult in such a wide open space! Thanks!
@jimmiebroadbrook1057
@jimmiebroadbrook1057 2 жыл бұрын
Hey there I bought the same exact tool from Amazon paid $150 for it but all the adapters to do the job I used this tool once not only was it super easy great to handle and it's already paid for itself I recommend this way above shark bites it's more professional looking and it's definitely stronger
@EverydayHomeRepairs
@EverydayHomeRepairs 2 жыл бұрын
I am a fan of Sharkbite as well but agree this is a great alternative and nice to have an option to buy a crimper that isn't $1000's of dollars. What brand of Press Fittings did you use NIBCO or ProPress (Viega)? I used NIBCO just because they are stocked at the Menards in my area.
@jimmiebroadbrook1057
@jimmiebroadbrook1057 2 жыл бұрын
@@EverydayHomeRepairs I used Viega cuz that's what was available but at the end of the day this system is 10 times better than SharkBite I think and my crimping tool looks exactly like the one you have same color telescopic arms and different size fittings half inch 3/4 1 in I have a couple more jobs to do in my house to fix the flood that I had so it's going to come in handy
@666mrgene
@666mrgene 3 жыл бұрын
I've used Sharkbites for about 8 years. The neat feature is that they can be removed, and reused. Oh, and are those caps in your video on the cut ends of the pipes for future use, Sharkbites ? No doupt you used them, so they can be removed. I think you should have pointed that out.
@EverydayHomeRepairs
@EverydayHomeRepairs 3 жыл бұрын
Yeah good point and I do really like the sharkbite caps. Very handy.
@Roy-ij1wq
@Roy-ij1wq 10 ай бұрын
I bought this tool for a whole house re-pipe following a deep freeze that burst many of the copper pipes. Fortunately, the water main was shut off and the house was vacant. All of the plumbing was in the unfinished basement. Several of the 70 year old copper solder joints blew apart as did the single shark bite connector that was used to repair a horizontal pipe. The 1" copper main blew open in the middle of a horizontal section of the pipe as did one of the 1/2" pipes. The main shutoff valve was also leaking a solder joint. I own a Milwaukee ProPex expansion tool and chose Pex A for the repipe. But I wanted something other than Sharkbites to transition to the copper pipes I wasn't replacing. My experience was similar to the video but I couldn't get it to work between some of the floor joists because there wasn't enough room to open the jaws. It is also difficult to get the tool properly aligned on the fitting because it is relatively heavy and you need both hands to get the clamp to close. All told, I'm pleased with the way the tool worked. I replaced the main shutoff valve without incident and kept a section of the verticle copper pipe because this is a 70 year old house and the electric panel is grounded to the water main. You can't do this with a Sharkbite because there is no continuity due to the plastic liner. But if I ever do another re-pipe, I'm buying the Milwaukee power press tool.
@scottd.brutout3835
@scottd.brutout3835 3 жыл бұрын
Cool video, with good detail. I didn't know there were any crimping solutions for copper (I never was good at sweating tubing). If I was doing this valve replacement, I would have added some extra tube to the stub to allow for a future valve replacement. That said, that ball valve will probably last a long time! Nice work.
@knnthl5326
@knnthl5326 3 жыл бұрын
Excellent presentation. But I will be too afraid to use press fitting: what would you do if there is a leak after the work is done? How can you fix it?
$100 vs $1000 Press Tool
10:45
Roger Wakefield Plumbing Education
Рет қаралды 126 М.
Plumbers Hate Me For Showing You This!
23:28
Fix This Build That
Рет қаралды 576 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
Гениальное изобретение из обычного стаканчика!
00:31
Лютая физика | Олимпиадная физика
Рет қаралды 4,8 МЛН
Truma VarioHeat Tech Tip: Understanding Common Error Codes
2:50
Truma North America
Рет қаралды 2
How to Flush a Water Heater? | Flushing Will Probably Not Fix Your Problem
8:06
The Grumpy Plumber
Рет қаралды 3,1 МЛН
Avoid These Mistakes With The  2 Most Common PEX Fittings
10:19
Everyday Home Repairs
Рет қаралды 57 М.
FIX LEAKING COPPER PIPE - PINHOLES - Plumbing Tips
9:54
plumberparts
Рет қаралды 3,8 МЛН
#1 PEX Plumbing Mistake You Don't Want to Make (A vs B)
6:14
Silver Cymbal
Рет қаралды 3,5 МЛН
Should You Use Sharkbite Fittings | DIY Plumbing
9:28
Everyday Home Repairs
Рет қаралды 467 М.