How to install a MR Cool DIY mini split Air conditioner (step by step)

  Рет қаралды 23,061

DIY JIM

DIY JIM

Күн бұрын

Пікірлер: 96
@DIYJIM
@DIYJIM Жыл бұрын
(click read more) Thank you very much for watching and God bless. ✅1800 BTU DIY Mr cool 3rd gen amzn.to/3KS209O ✅9000 BTU DIY Mr Cool 3rd gen ✅12000 BTU DIY Mr Cool 3rd gen. amzn.to/3TDa41U ✅24000 BTU DIY Mr Cool 3rd gen amzn.to/3epObDl ✅36000 BTU DIY Mr Cool 3rd gen. amzn.to/3cUQxtf ✅line set cover Mr Cool. amzn.to/3Bq3i8V ✅AC wall mounting bracket. amzn.to/3D0V0FE ✅10/2 wire amzn.to/3cQ8uJE ✅AC Disconnect (I bought at Lowes but this is similar) amzn.to/3KQM7A5 ✅6 Ft Whip amzn.to/3CYyVY8 ✅Drywall anchors amzn.to/3cJjI2F ✅Gorilla white tape amzn.to/3wYe6bI ✅ My T-shirts. Thank you for supporting my channel✅ diy-jim.creator-spring.com 5% off shirts use DIYJim2021 when checking out ✅GIFTS and THANK YOU✅ DIY Jim PO Box #105 Hughesville Pa, 17737 0:00 intro, what comest with Mr cool 4:12 supplies That did not come with Mr Cool 5:09 Tools I used 7:20 start to install mounting plate 12:30 find studs install mounting plate 15:00 Drilling 3 1/2" hole 17:40 hang indoor unit Evaporator 20:00 outdoor unit condenser 20:40 drill hole through siding 23:24 start to connect and bend line set 33:17 release refrigerant check for leaks 35:25 condensate drain hose 36:13 Electrical 39:22 start Mr Cool 41:20sound deadening pads insulate 45:30 ending ✝Bible ESV easy to read amzn.to/3qshNQP ✝Bible NKJV amzn.to/30ns322 ✅Titan Solar Generator (large generator) poweredportablesolar.com/ref/48/ ✅Sony ZV-1 (camera I use) amzn.to/3MxVeG2 ✅sony wireless UWP-D (mic I use). amzn.to/3LEPV6m ✅Go Pro that I use amzn.to/2WC6WXH ✅Wireless mic used: Rode Wireless Go amzn.to/2WxQt7c *Full transparency. I am a participant in the Amazon Services LLC Associates program, an affiliate advertising program designed to provide a means for me to earn fees by linking to Amazon.com and affiliated sites. *Disclaimer - Thank you for visiting my KZbin channel. Please understand that the content on the DIY jim KZbin channel is intended for informational purposes only. I make no warranties about the completeness, reliability and accuracy of this information. Any action you take upon the information posted on my KZbin channel is strictly at your own risk, and I will not be liable for any losses and damages in connection with the use of my KZbin channel.
@user-ft6ji3or6d
@user-ft6ji3or6d Жыл бұрын
This was a great help! We too are doing the install a bit different as I must go through the attic and down through the back of a closet and then outside at the bottom of the closet. And you are right, you are the first to show an alternative route. Fortunately the 25' will be long enough and hopefully end up looking as neat as yours. Great idea to use the PVC pipe for the drain line. I think I will do that to ensure the slant stays true through the attic. I am a 78 year old great grandmother. For 60 years I have been my husband's helper and now we have had to reverse roles. Wish us luck!
@DIYJIM
@DIYJIM Жыл бұрын
Awesome I hope it turns out good. If you lived near me I would come help. God bless
@chrisd4283
@chrisd4283 28 күн бұрын
Thank you for this. Perfect timing as I look to install a 36BTU in my garage.
@DIYJIM
@DIYJIM 27 күн бұрын
Thanks for watching
@slipstreamvids7422
@slipstreamvids7422 Жыл бұрын
Good detail in covering any exposed copper with insulation as it will sweat and drip if left exposed. Also one of the neatest and easy to watch install vids on this subject.
@DIYJIM
@DIYJIM Жыл бұрын
Thank you ver much
@geneefonseca3647
@geneefonseca3647 Жыл бұрын
This is the BEST video with the most detailed installation instructions!
@DIYJIM
@DIYJIM Жыл бұрын
Thanks
@maxheadroom8677
@maxheadroom8677 Жыл бұрын
Jim Excellent Video, very nicely done and you have provided a ton of good information. The only thing I would add would be about the electrical connections/wires out side - from AC disconnect to outside unit. Normally green is used for ground, back for hot, white for neutral (or second hot line if it is 240V, sometimes red is also used for second hot line).
@DIYJIM
@DIYJIM Жыл бұрын
Thanks for the info this is definitely why I said I’m not a professional election. Thanks for watching Max
@festerofest4374
@festerofest4374 Жыл бұрын
Really good video! I'm in the process for planning to install my own 18k unit and have been watching tons of YT videos (there are a lot - thank you YT!) so I can learn anything and everything to anticipate every step of the installation and get all the needed parts organized before I even get started. Like yours, mine will be a bit non-standard in that I'm running the line set from the interior wall of my living room and through the garage to the outside wall of the garage. I will have a few feet of extra from the 25' line set (16" is also available but it would be just a couple of feet short). Like your install, I will snake the extra line set horizontally on the garage rafters before running it down the inside wall of the garage before exiting the outside of the garage wall right to the condenser. I won't need any line set cover. Also, my condensate hose will be run to a different location on another side of the garage. I will mount the condenser on the outside garage wall (not on a pad) and what's driving me crazy is there are tons of mini-split condenser wall mount racks (some in stainless at reasonable prices) on Amazon and HVAC supply places, but finding one suitable to mount to 16"OC studs 32" apart seems next to impossible so far. The strictly vertical brackets available in pairs don't have the necessary cross members to accommodate the condenser mounting feet of the 18k unit at 26.1" (663 mm) wide. I don't want to mount the rack at only 16" OC for a heavy condenser that is 35" wide! I'm really surprised I'm not finding a suitable rack. There are several I've found that go only to about 30.5" wide (including the one you link to).... WTF! What the hell am I supposed to do... go to a metal fabricator to make custom cross members?? Seems that mounting into studs at 32" wide would be a common need based on typical condenser sizes. Again, WTF? The only thing I wish you have covered in your otherwise great video was the electrical connection from the AC disconnect to the condenser. I've seen it in a couple of other videos but people have done it a little differently and I want to be sure I have it nailed before I start, as I'm doing my own electrical wiring from adding a 30A double pole breaker, running the wiring through conduit inside the garage, then out the wall directly into the AC disconnect switch. At that point I will only need a couple of feet of AC whip to the condenser. Wish me luck!
@DIYJIM
@DIYJIM Жыл бұрын
Hope it all turns out great you definitely seem to have a good plan. Glad my video helped you and thanks for watching
@francoisbernard3513
@francoisbernard3513 Жыл бұрын
Very well made video and easy to understand. Thanks for all the hard work to put this video together. Very helpful.
@DIYJIM
@DIYJIM Жыл бұрын
Thank you and thanks for leaving a comment and subbing if you did.
@chargermopar
@chargermopar 2 жыл бұрын
The real Mr Cool is Jim. As for me, I cannot afford those Mr Cool products. Instead I got hold of a used Daizuki 36,000 BTU system and soldered together copper lines. It has a noisy fan motor, but gets plenty cold and costs 25 dollars a month to operate. SInce I put the evaporator on the inside wall I had to be creative with the drain which goes to the kitchen sink. Like you I did not want any extra lines hanging around so I ran it through the attic and then down from the overhang, our walls are block and poured concrete. I did not feel safe running a black extension cord with 220 so I ran steel conduit and pulled 14 gauge wires from the condenser to the evaporator. 8 gauge from condensing unit to the fuse box. As always love the detail you give us!
@DIYJIM
@DIYJIM 2 жыл бұрын
Sounds like you have a nice setup. Thanks for watching my friend
@SoupPot
@SoupPot 2 жыл бұрын
Very informative. Thanks for helping us all be a little more self-reliant.
@DIYJIM
@DIYJIM 2 жыл бұрын
Welcome thanks for watching
@fattysgarage1754
@fattysgarage1754 Жыл бұрын
Great job Jim. Only issue is you used green wire for line 1 and black wire for ground . Please reverse this. Green is only allowed for ground never anything else except some odd traffic light situations. Black cannot be a ground. All things being equal it wont be an issue but anyone else ever works on this could get hurt. Also green wires are sometimes smaller because a ground wire can be undersized. Not sure if yours is. NEC 250.119 prohibits any green, green/yellow striped or bare wire from being used as hot. Easy fix.
@DIYJIM
@DIYJIM Жыл бұрын
Thank you for pointing this out I will check it out and change so know one gets hurt. Thanks again
@thefleaflop
@thefleaflop Жыл бұрын
Great job Jim.... I contacted Mr cool today looking for the video of removing the blower fan,. Turns out the only one available is a guy removing the blower MOTOR. He does a nice job, but not exactly what I wanted... Just trying to get the blower fan blade out to clean it on my 2400 DIY indoor unit.
@DIYJIM
@DIYJIM Жыл бұрын
Maybe I will try to make a video one of these days.
@ronaldwhite4551
@ronaldwhite4551 11 ай бұрын
Thank thank thank you. I have a situation where I need to run the lines to the right side of the evaporator.. I have been stressing out and some of the communications with customer service has been lacking. I feel more confident running the line to the right.
@DIYJIM
@DIYJIM 11 ай бұрын
Just bend the pipe slowly, use both hands. I’m sure it will turn out great.
@shakeysafari6203
@shakeysafari6203 8 ай бұрын
Great video! I too hate the excess line rolled up outside, as well as the condensate drain line (vs PVC). Thanks for the help. Giving it a go next week.
@DIYJIM
@DIYJIM 8 ай бұрын
Hope it turns out good for you. Thanks for watching
@kevin9c1
@kevin9c1 Жыл бұрын
The whole checking for leaks thing is a bit hopeless because the line fittings are O-ring based. The torque specs really just ensure you have bottomed the fitting (as opposed to still drawing it together). The threads don't seal anything and there's no flare connection that needs to seat or something. If you have a leak at a line set fitting, you are probably hosed, but at least you can stop and then probably deal with your vendor/Mr Cool for the next steps (as opposed to running the unit low on refrigerant).
@timshumbera654
@timshumbera654 6 ай бұрын
That's good to know.
@martinnegron8692
@martinnegron8692 Жыл бұрын
Jim, great video... truly helped! Keep going man, you have a gift!
@DIYJIM
@DIYJIM Жыл бұрын
Thanks, will do!
@alexander2685
@alexander2685 2 жыл бұрын
Jim sir all I can say your dad taught you well if I can remember everything my dad taught me I can do everything without paying anyone also watching your videos 😁😊what can you not do take care great video as allways.
@DIYJIM
@DIYJIM 2 жыл бұрын
I am not a very good mechanic. That’s what I’m not good at. Thanks again Alexander
@InFltSvc
@InFltSvc 2 жыл бұрын
That’s a big project you did there JIM. Great job!
@DIYJIM
@DIYJIM 2 жыл бұрын
Thank you hope you had a good weekend
@theblackwoods7055
@theblackwoods7055 Жыл бұрын
Thanks, you gave me the confidence to do my garage!!!
@DIYJIM
@DIYJIM Жыл бұрын
Your welcome thanks for watching
@algamingunboxing7354
@algamingunboxing7354 Жыл бұрын
Gracias, Buen Trabajo.🥰
@DIYJIM
@DIYJIM Жыл бұрын
Your welcome
@martinw3446
@martinw3446 Жыл бұрын
Great video Jim 👍
@DIYJIM
@DIYJIM Жыл бұрын
Thanks Martin
@kevin9c1
@kevin9c1 Жыл бұрын
My preferred method is to try to come up with an air handler/condenser location that is favorable to either a 25 or 16 (or multiples if longer) line set. Then, since your design is close, wait to place the condenser until you have hung the inside unit(s) and draped the line set down the house and over to the condenser area. Once that is roughed in, you can choose the final location for the condenser. For example, I am planning (my second install) a 2 zone system. One room requires about 16 feet and the other about 25 feet. I poured an oversize pad so that I had some room to slide the stand back and forth depending on which line set is really driving the condenser placement. We'll see how I did...
@hankjordan2602
@hankjordan2602 7 ай бұрын
Thanks for the information I was wondering if you could take the lines out the side of the inside unit instead just out the back.
@DIYJIM
@DIYJIM 7 ай бұрын
I think I did take it out the side. So I guess your answer is yes. 12:09
@brettc9763
@brettc9763 Жыл бұрын
Thank you for your video, It gave me a better understanding of the condensate line. But, notching the bottom of floor or ceiling joists is never legal. Stacking your holes vertically significantly weakens your joists as well. Generally, for non engineered lumber, it is legal to drill holes one third of the depth of the joist, in the outer third of length of the joist in the center third of the joist. Not sure here, but it makes sense that the holes should be six inches apart. Engineered beams have specific drilling specifications that can be looked up, last ones I worked with allowed only holes in center third and nowhere near one third of depth. If your job is going to be inspected, I highly recommend looking up where and what size holes are legal. Really expensive to replace joists and beams.
@DIYJIM
@DIYJIM Жыл бұрын
Thanks for the information. Thanks for watching
@brettc9763
@brettc9763 Жыл бұрын
@@DIYJIM I really like the idea of using landscape water pipe for the condensate lines. I am in the middle of converting my 2600 sq ft home into a duplex or ADU unit. Your video cleared up a lot for me. I talked to a HVAC contractor friend and when installing line sets through joists, he advised splitting the set and drilling two holes, I have taken a razor knife and easily split the out and in lines. I will be attempting to use one 1 3/4" and one 1 1/4" bits. I will have to measure twice to make sure my holes are perfectly straight but at 64, not my first Rodeo.
@kevin9c1
@kevin9c1 Жыл бұрын
You could have gotten your system with a 16 foot line set instead of 25. Ingrams will let you do that, for example.
@DIYJIM
@DIYJIM Жыл бұрын
Thanks for watching, I can not complain I just tried to make a nice video for the company they sent me the AC for free. Thanks for watching
@febeleven
@febeleven 2 жыл бұрын
You did a wonderful job. It looks clean the way you installed it. Did you say your unit was also for heat? I need my son in law to install one in my garage. Have a great weekend!
@DIYJIM
@DIYJIM 2 жыл бұрын
Yes it’s a heat pump. It will cool and make heat. Only makes heat good, if it is 20deg or warmer. I’m guessing I will be trying it this winter.
@febeleven
@febeleven 2 жыл бұрын
@@DIYJIM Thanks Jim!
@oldcaliforniakid
@oldcaliforniakid Жыл бұрын
Nice video! Can you tell me the measurement between the front and back holes in the feet of the condenser?
@DIYJIM
@DIYJIM Жыл бұрын
13 5/8 hope this helps
@oldcaliforniakid
@oldcaliforniakid Жыл бұрын
@@DIYJIM Thanks so much, Jim! It helps a lot!
@festerofest4374
@festerofest4374 Жыл бұрын
See page 22 of the installation manual for all the dimensional specs: mrcool.com/wp-content/dox_repo/mc-diy-4-es-im-um-en-01.pdf
@rich1807
@rich1807 Жыл бұрын
Nice no evacuation
@DIYJIM
@DIYJIM Жыл бұрын
Correct it comes ready to hook up. No need to use vacuum
@rich1807
@rich1807 Жыл бұрын
@@DIYJIM line set and evaporator are already in a vacuum?
@DIYJIM
@DIYJIM Жыл бұрын
@@rich1807 yes
@tf2694
@tf2694 Жыл бұрын
Great video thank you
@DIYJIM
@DIYJIM Жыл бұрын
Welcome thanks for watching
@dougclark787
@dougclark787 Жыл бұрын
Jim my question is u don't need to run a neturel wire? And how's the harman working
@DIYJIM
@DIYJIM Жыл бұрын
No neutral it’s 240 and Harmon still going good.
@jbabe3282
@jbabe3282 Жыл бұрын
Do u have a video on how to safely do the breaker 220 in the house?
@DIYJIM
@DIYJIM Жыл бұрын
Sorry I do not
@kevin9c1
@kevin9c1 Жыл бұрын
I don't think the wire gauge/amp table at the beginning is correct. The 18k unit should be a min of 12 gauge and a max of 10 gauge. 18k and up runs on 240V. For my single zone 18k I ran 12/2 and used a 20A breaker. For the 18k dual zone I am installing I elected to run 10/2 and use a 25A breaker, because of the second inside unit.
@festerofest4374
@festerofest4374 Жыл бұрын
In a different video on the 18k unit someone else said the same thing.... that 8 ga was too large....it should be 10 ga, but I don't understand why. I'm planning on a 30A double pole breaker and not sure if I should use 8 or 10 ga.
@kevin9c1
@kevin9c1 Жыл бұрын
@@festerofest4374 10 is sufficient. Don't need that 30A breaker either.
@festerofest4374
@festerofest4374 Жыл бұрын
@@kevin9c1 Thank you so much for the reply! The electrical part is the last part of the whole project I don't feel totally comfortable with. So I shouldn't need a 30A breaker? These are the specs from the install manual, if that helps confirm exactly what is needed: 208-230V, 60Hz, 1 Ph Min circuit ampacity 18 Max fuse (outdoor) 30 (MOP?) If you are able to confidently answer this I'd really appreciate it! What type of breaker is most suitable, the best possible for long life of the compressor and safety, even if it's a little overkill? I was reading that larger wire is helpful in reducing start-up load on the compressor, hence 8 ga, particularly since the manual states min 10 ga, 8 preferred. But I've read other comments with people saying no, don't go with 8 ga... use 10 ga. When following the suggestion of another video, 30A double pole seemed really easy for me to understand how to wire to the breaker.... two hot (one black, one red) and a ground. With this wiring it seemed really straightforward from the breaker to the AC disconnect switch, and then into the panel on the condenser with he same wiring plan. What should I be doing, to do it the best way? Thanks!
@kevin9c1
@kevin9c1 Жыл бұрын
@@festerofest4374 My manual for my 18k gen 4 two zone says 18 min and 25 max. Min 12 ga but 10 ga preferred. So for mine I did the biggest everything. 10 ga, and 25A breaker. A 30A could be unsafe and theoretically damage the equipment even if you used 8 ga. A 25 double pole is the same as a 30. White and black for the two hot legs. So use 10/2 cable. I am talking about the breaker in your panel. For the disconnect box I wouldn't even bother with a breaker unless you think your code requires it. I use a 10ga whip from the disconnect box to the condenser. It is stranded cable and is easy to connect.
@timshumbera654
@timshumbera654 6 ай бұрын
@@kevin9c1The breaker in your service panel is just there to protect the wire in your structure, not any equipment or device you hook to that circuit.
@jimbickel8538
@jimbickel8538 Жыл бұрын
Jim, Great info. Did you the power from your panel to the shut off or did you have an electrician do that? If you did it, please share the steps. Thanks.
@DIYJIM
@DIYJIM Жыл бұрын
I did but I’m not an electrician that’s why I did not share a lot about the electrical. Sorry
@markkeddis2709
@markkeddis2709 2 жыл бұрын
Man you make everything look easy. How does the Mr. Cool compare so far with the Mitsubishis you have? By the way-that Gorilla tape IS indeed the best. It’s like Frank’s Red Hot…I put that $#!t on everything haha.
@DIYJIM
@DIYJIM 2 жыл бұрын
Well the AC is in my garage so I can not do a very good comparison. Since I have not keep it on all the time. I will probably use it more for heat this winter.
@kathyern861
@kathyern861 Жыл бұрын
Hey DIY Jim - how you calculate the correct BTU for your mini-split system?
@DIYJIM
@DIYJIM Жыл бұрын
I would just give them a call or I think it says how much SQ FT each one is good for on their website. Just take your length times width of your room to figure out square footage.
@Brandonfixes
@Brandonfixes Жыл бұрын
What program do you use to edit videos?
@DIYJIM
@DIYJIM Жыл бұрын
iMovie on my Mac. You looking into starting your own channel? kzbin.info/www/bejne/qIqlfaugqKeqesU
@srairmand
@srairmand Жыл бұрын
Why do all videos about this skip the wiring part? You just suddenly see the wire all set up and ready.
@DIYJIM
@DIYJIM Жыл бұрын
Sorry because I’m not an electrician
@mariaa9728
@mariaa9728 Жыл бұрын
I installed a 18k but is not heating and sometimes comes a code PC 03
@DIYJIM
@DIYJIM Жыл бұрын
I would call the company hope you get it figured out
@daveyboy8907
@daveyboy8907 Жыл бұрын
How big does the slab need to be for this 36k?? Ordering mine soon.
@DIYJIM
@DIYJIM Жыл бұрын
Not sure how big the condenser unit is on the 36k? Sorry can not help
@robertsheward9336
@robertsheward9336 Жыл бұрын
I did mine 24"×48"
@daveyboy8907
@daveyboy8907 Жыл бұрын
@@robertsheward9336 thanks I poured one a few months back and bolted a stand to it since we have snow.Thanks for reply.
@brontoab1
@brontoab1 9 ай бұрын
KZbin, can you please stop returning sponsored videos. I don't care about videos that paid for by vendors.
@DIYJIM
@DIYJIM 9 ай бұрын
Thanks for watching still like my heat and AC in my garage. Thanks for commenting
@gsftom
@gsftom 2 жыл бұрын
Are u the 75th guy that got a mr cool free for doing a video?
@DIYJIM
@DIYJIM 2 жыл бұрын
I couldn’t tell you but it is a nice AC. Thanks for watching
@robertsheward9336
@robertsheward9336 Жыл бұрын
Dude, you really used a green wire for a line wire and a black wire for a ground?
@DIYJIM
@DIYJIM Жыл бұрын
Thanks for pointing this out. I think I said I was not an electrician. But I have changed it. Thanks for watching
@DIYJIM
@DIYJIM Жыл бұрын
I also took that part out of the video. I do not want anyone to get hurt. Thanks for pointing it out. Hope you have a good 4th.
@Shalmaneser1
@Shalmaneser1 Жыл бұрын
Up next: Jim does a 2 ton goodson split! :p
DIY Mini Split Install - All the Things Nobody Shows You
33:25
LRN2DIY
Рет қаралды 2,1 МЛН
MR COOL DIY 4TH Generation 18K BTU Garage Install
37:08
RAIDER WORLD
Рет қаралды 70 М.
Dad gives best memory keeper
01:00
Justin Flom
Рет қаралды 20 МЛН
Unveiling my winning secret to defeating Maxim!😎| Free Fire Official
00:14
Garena Free Fire Global
Рет қаралды 16 МЛН
Complete DIY Mini Split Installation | New Mr Cool 4th Gen Unit
18:43
Everyday Home Repairs
Рет қаралды 414 М.
How to Install 12V Split Air Conditioner?
25:54
Taddy Digest
Рет қаралды 105 М.
Step-by-Step Guide: Installing DIY Mini Split Dual Zone | Senville | Mr Cool
37:40
I Installed A Heat Pump In My Garage! (MRCOOL DIY Mini Split 3rd Gen)
11:46
Jason Explains Things
Рет қаралды 124 М.
Della Mini Split AC Installation Step By Step 2024 | Total Installation
32:01
MrCool DIY Ductless Mini Split Install
14:57
PatriotDIY
Рет қаралды 46 М.
DIY Central Air Install for $3300 (Including Tools!)
40:43
LRN2DIY
Рет қаралды 353 М.
How-To: MRCOOL DIY Mini Split Installation (Step by step) / Garage has A/C!
55:37
How-To Motorcycle Repair
Рет қаралды 711 М.
DIY Ductless Mini Split Install - MrCool Unit
9:44
April Wilkerson
Рет қаралды 1,7 МЛН