How To Install An AC disconnect - ALL WIRING!

  Рет қаралды 41,259

The Excellent Laborer

The Excellent Laborer

Күн бұрын

Non-Fusible A/C Disconnect amzlink.to/az0kGRpQKK9qa
In this video, I show how to install an AC disconnect. I include all of the wiring step by step. I show how to wire the breaker into panel box to power the AC disconnect. I also show how to wire the disconnect and whip for the HVAC unit. This AC disconnect is for a mini split. Enjoy!
My Favorite Tools And Supplies 👉 amzlink.to/az0KsA48iJTo2
Tools And Supplies Used In This Video👇
EATON DPU222RP Non-Fusible A/C Disconnect amzlink.to/az0kGRpQKK9qa
Klein Tools 32500 11-in-1 Screwdriver amzlink.to/az0NjyK5L0KZm
3/4-Inch Romex Connector amzlink.to/az0eI9cOfTOYI
3/4" wire staples amzlink.to/az0TfVQROer4E
More Helpful Related Videos👇
How To Install A MrCool DIY Ductless Mini Split YOURSELF! - FAST and EASY! • How To Install A MrCoo...
How To Wire A Garage - EASY Electrical Wiring Basics For Beginners (Workshop, bathroom, and more!) • How To Wire A Garage -...
🟢 Become a channel member:
/ @theexcellentlaborer
🔴 Subscribe to this DIY channel: kzbin.info...
🟡 Check out my Amazon store: amzlink.to/az0KsA48iJTo2 . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that helps support the channel at no extra cost to you)
Timestamps
Intro 00:00
Disconnect Overview 00:19
Preparing Disconnect 01:18
Disconnect Rough-In 02:31
Panel Box Wiring 05:37
Disconnect Wiring 11:15
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.

Пікірлер: 58
@busboy3943
@busboy3943 5 күн бұрын
Wow! Great video, well explained without all the jabbering that is on so many channels. And your fast-forwards are perfect. Very well done!!! Thank you.
@johnbrunzell
@johnbrunzell Ай бұрын
Excellent step by step. Nobody else has this content in this simple of terms. Thank you!
@ianmiddleton1877
@ianmiddleton1877 26 күн бұрын
Remodeling an old house I watch a lot of your content. Really appreciate the effort in your videos and they've helped me a bunch.
@vgoose50
@vgoose50 23 күн бұрын
Nice to see your attaching the ground first, It would of been good to mention that when connecting, just as good practice even thou the breaker is off. Thanks nice video.
@alex_klinger
@alex_klinger 3 ай бұрын
This video couldn’t have more perfect timing. Installing new mini split in garage soon and I’ve been looking for this information/techniques. Much appreciated and great job! 💪🏻
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
You are welcome! Good to hear. I hope it helps you. Let me know how it turns out!
@lucasnosal2987
@lucasnosal2987 6 күн бұрын
Your videos are great!! Keep it up!
@TheExcellentLaborer
@TheExcellentLaborer 6 күн бұрын
I’m glad you liked it. Thanks for watching!
@davidharrison3074
@davidharrison3074 3 ай бұрын
Great job Josh. Torque on breakers is important. So many don't do this simple procedure. Great to see every step and the importance of local codes. I have used a VEVOR Torque screwdriver for a while which is very handy. Again, such a wonderful video Josh. 🔨🔨👍🏻👍🏻
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
Thanks, David! Information stamped on the breaker is not very noticeable. It’s nice to know the torque specs are right on the side. Thanks for stopping by and watching my video! Take care, David!
@kennybutcher6307
@kennybutcher6307 Ай бұрын
the electrician that helped install my panel didn't torque ... He jammed the screws so tight that some of the copper was pinched almost in half. SO re terminated each breaker by cutting the pinched exposed wire he did and actually torqued it properly. That's annoying.
@davidharrison3074
@davidharrison3074 Ай бұрын
​@@kennybutcher6307it sounds like you did the right thing. It doesn't take much to take that little bit of time to torque them. Over tightening them can also cause issues down the road. Hopefully your project is safe and secure now.
@vince6829
@vince6829 3 ай бұрын
Nice job. Thanks for sharing your knowledge.
@Ticonderoga12
@Ticonderoga12 3 ай бұрын
Great vid bro, probably the best vid ive seen on how to do this
@salvadorcastillo1539
@salvadorcastillo1539 3 ай бұрын
Thanks for your videos, those videos help me a lot of....
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
I try to make the videos as helpful as possible. Thanks for watching!
@Tsikura
@Tsikura 3 ай бұрын
I like to put some duct seal around the cable connection before screwing on. Helps with reducing air and water entry.
@tomatexelon
@tomatexelon Ай бұрын
I had the same problem you did at 13:40 knocking out the metal inserts. It seemed like mine was tacked welded to good when they made the box and more was removed than I wanted. So I had to buy reducing washers like you did. I feel better now.
@renosgarage7451
@renosgarage7451 3 ай бұрын
Thanks bro imma use this same process to put a 240v plug on the side of my garage for an air compressor
@masonbeveridge
@masonbeveridge 3 ай бұрын
Thank you
@TB-ki1ux
@TB-ki1ux 3 ай бұрын
Quality content and insights once again, thank you sir
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
That is the goal of my channel. I appreciate you watching!
@TB-ki1ux
@TB-ki1ux 3 ай бұрын
@@TheExcellentLaborer You are succeeding at that goal. I appreciate your time and effort sharing your impressive knowledge and insights
@sfl6307
@sfl6307 3 ай бұрын
That was 👍🏻Thanks again!
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
You’re welcome. Thanks for watching!
@Eddy63
@Eddy63 3 ай бұрын
Nice job ... Thx
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
Thanks Eddy!
@Rob-lr4cj
@Rob-lr4cj 16 күн бұрын
Note that for minisplits, you can actually size your wire to the minimum circuit ampacity that's on the unit's info plate, not the maximum over current protection (breaker size). Probably not issue oversizing as long as your termination points are rated for that wire gauge, but you may not have to.
@djfury05
@djfury05 3 ай бұрын
I'd like to see a detailed guide on how to shorten the lineset down so all the excess is not coiled up. I've had a MrCool mini split for a couple years now that I installed start to finish including the AC disconnect and it's great minus the ugly lineset coiled up situation.
@taniksambo1969
@taniksambo1969 3 ай бұрын
do you apply for the permit fist before installing?
@rodoclimaarcondicionado9011
@rodoclimaarcondicionado9011 3 ай бұрын
Top de mas eu sou técnico de mini split ar condicionado no Brasil mas eu estou em Massachusetts
@everardozarco3869
@everardozarco3869 3 ай бұрын
The torque is definitely not 45 pounds.!! It's only 45 inch pounds.. Great video
@sfl6307
@sfl6307 3 ай бұрын
Thank you for educating us, as we have more money to spend with this economy being good after a pandemic, we can hire the professionals and at least have the knowledge as to what we are paying for and what needs to be done.
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
You are welcome. Thanks for watching!
@MaMa-qh4dy
@MaMa-qh4dy 3 ай бұрын
"Economy being good?" What planet are you living on??? Have you ever been to a grocery store or gas station lately??? All hanks to CLUELESS Joe!
@seamusmcguire376
@seamusmcguire376 2 ай бұрын
Hahahahaha
@fishlanding
@fishlanding 3 ай бұрын
the guy that put mine in put a surge protector on too to help protect the condenser...
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
That’s not a bad idea!
@fuegoman45
@fuegoman45 3 ай бұрын
Surge protectors are required (at least in California) on the main panel.
@jamesshannon88
@jamesshannon88 10 күн бұрын
Just curious...I just bought the 12k (120v) and I'm wondering if I'll need the outside disconnect still.
@Here12years
@Here12years Ай бұрын
How do you move an existing electrical disconnect from a chain link fence to the side of a brick house? The chain link fence is up to the brick, so it will only be about 2'
@jamess5872
@jamess5872 25 күн бұрын
Arlington MM10 mounting block would've been better for this install. It's just right right size for a siemens 60 amp disconnect
@anthony3953
@anthony3953 2 ай бұрын
What would’ve been nicer is a bushing in the back of the disconnect for a flush fit with no gap between the disconnect and wall instead of that Romex connector.
@juancardoza6069
@juancardoza6069 24 күн бұрын
No neutral needed for this wiring?
@realSamAndrew
@realSamAndrew 6 күн бұрын
I know the lugs are labeled with the inside as LINE and the outside as LOAD. But technically, it shouldn't matter if you reversed it. The pull piece just connects the two sides to each other, it doesn't care which is which or whether they are right or left, inside or outside, top or bottom. Correct?
@OneManLikeNoOneElse
@OneManLikeNoOneElse 3 ай бұрын
🆘Question, if I have a 150 amp meter box and put a 60 amp disconnect plus have a 50 amp disconnect going to my main panel and another 50 amp disconnect going to a sub panel, is that to much for my meter? Can I do a 40 amp disconnect for my sub panel or main??? Do I sound like I have no clue because I didn’t know about electrical but I hired a neighbor to upgrade my 100 amp meter to a 150 amp and he has two 50 amps coming off the meter with one for my main and one for my sub panel! It doesn’t seem right and no and then I hear a buzzing noise coming from my meter panel box!!! Please help because I still don’t have a disconnect for my outside condenser unit!🙏🏼🆘
@fuegoman45
@fuegoman45 3 ай бұрын
The total amps of all the breakers is irrelevant. If you have 150 amp service, then that’s how much you can use at any given time. Even if all the breakers add up to 200 amps. If you ever tried to use more than 150 your main would trip.
@jay_hubs_8955
@jay_hubs_8955 Ай бұрын
This video has now made it extremely hard for me to see reason to hire an electrician to install a disconnect for the mini split I want to install for our garage
@agoretoy
@agoretoy 28 күн бұрын
Nice work, however @ 5:07 it would be nice to put some silicon at mounting block/vinyl transition to prevent moisture/water entering behind vinyl and eventually damaging wall
@TheExcellentLaborer
@TheExcellentLaborer 28 күн бұрын
Thank you! A little silicone there definitely would not hurt anything. Thanks for your input!
@jamesborton9237
@jamesborton9237 3 ай бұрын
I would have used 3 wire, so I would have a red sheathed conductor.
@CoryBrian
@CoryBrian 3 ай бұрын
That's 45 inch pounds, if someone was wondering. And be careful not to confuse with foot pounds.
@theseattlegreen1871
@theseattlegreen1871 2 ай бұрын
Why did you decide to purchase a non fusible disconnect? Why not install a fusible disconnect?
@user-rl7ho5sf1n
@user-rl7ho5sf1n 28 күн бұрын
No reason to. The fuses would be redundant to the circuit breaker. Also they are extra expense and complexity. A fusible disconnect is roughly the same price as a non-fusible, but you have to buy fuses to make it work. Extra cost.
@wesleystaub5416
@wesleystaub5416 3 ай бұрын
The white wire you put black tape on should have had red tape on it
@fuegoman45
@fuegoman45 3 ай бұрын
Never seen that. I always see black tape to indicate the wire is hot.
@jamesborton9237
@jamesborton9237 3 ай бұрын
​@fuegoman45 another choice could be red or black heat shrink on your conductor to indicate a "hot" .
@Habibthehvacguy
@Habibthehvacguy Ай бұрын
Budddy I know you are trying to teach DIY to people but make sure you do it right , there are steps you are missing which cause lots of problem to you unit . Please read the manual before you do this kind of videos
How To Install A 60 Amp AC Disconnect
17:52
Skill Savvy DIY
Рет қаралды 11 М.
WHY DOES SHE HAVE A REWARD? #youtubecreatorawards
00:41
Levsob
Рет қаралды 28 МЛН
어른의 힘으로만 할 수 있는 버블티 마시는법
00:15
진영민yeongmin
Рет қаралды 5 МЛН
Miracle Doctor Saves Blind Girl ❤️
00:59
Alan Chikin Chow
Рет қаралды 26 МЛН
Dryer Receptacle Installation - 4 Prong Outlet Wiring
8:06
The Excellent Laborer
Рет қаралды 244 М.
Correcting 3 Mistakes On A 240V Outlet Install
8:48
Everyday Home Repairs
Рет қаралды 455 М.
How to wire 120V quick disconnect box for mrcool mini split unit
1:19
Shemsta LLC Electricial Repairs and installation
Рет қаралды 26 М.
How to Install an AC Disconnect
3:17
HVAC School
Рет қаралды 149 М.
How to Install a New Circuit Breaker
2:50
Family Handyman
Рет қаралды 954 М.
Complete DIY Mini Split Installation | New Mr Cool 4th Gen Unit
18:43
Everyday Home Repairs
Рет қаралды 198 М.
How To Vacuum Down a Mini Split with Analog Manifold Gauges
6:29
HVAC Mechanic
Рет қаралды 237 М.
flying fish! IN THE SEA II Holy sight #shortsviral #fish #seafood
0:12
#shorts
0:11
Khánh Ngọc Shorts
Рет қаралды 7 МЛН
Отказалась от золотой медали?🤯
0:34
Фильмы I Сериалы
Рет қаралды 12 МЛН
Шеф-повар со шваброй😦
0:33
FilmBytes
Рет қаралды 2,6 МЛН