How to Perform Power Factor Testing with Megger Delta 4000 Instrument

  Рет қаралды 9,236

Megger US

Megger US

Күн бұрын

Пікірлер: 11
@sMartiSingler
@sMartiSingler 2 ай бұрын
I loved the presentation. Especially the Q&A part. Congratulations!
@elctricalpower2061
@elctricalpower2061 3 жыл бұрын
Great Video and thanks a lot for explanation in details Sir.
@sMartiSingler
@sMartiSingler 2 ай бұрын
Whenever I measure C2, I necessarily need to use the blue cable on the bushing base flange, in the GST-gR configuration, with the red cable on the bushing power pin and applying 500 volts. If I don't do this, the DF and Capacitance values ​​are very high. But you advise using only two cables (without using the blue cable). I find this strange, because, naturally, the losses, added together, up to the reading return, through the green cable (ground) of the device, are always, obviously, very high (because of all the capacitances involved).
@sMartiSingler
@sMartiSingler 2 ай бұрын
I was forgetting to ask: in the past (with the NANSEN MEU-2500), we manually inverted the polarity to obtain an exact Ir reading (to calculate P in W). Does the Delta 400 currently still take TWO readings and take the average? Or does it read JUST ONE VALUE directly using a "Band Pass Filter"?
@sMartiSingler
@sMartiSingler 2 ай бұрын
( For capacitance reading, since there is a wide range of frequencies... ) Does the Delta 4000 have "TWO" Bridges? (... Wein and Schering? )
@sMartiSingler
@sMartiSingler 2 ай бұрын
At low frequencies, due to the polarization of the dielectric, it is natural that the dissipation factor is higher. Ok. But how do you know if this value, as read, is still within an acceptable range?
@sMartiSingler
@sMartiSingler 2 ай бұрын
The cellulose layer, in C2 of the bushing, causes a high power factor value. Is it because of THIS that, on the bushing plate, ONLY the capacitance of C2 appears? (Would the function of this cellulose be to "force the direct grounding of the capacitive tap, without depending on the grounding of C2" (while the cover of the capacitive tap remains closed)?
@sMartiSingler
@sMartiSingler 2 ай бұрын
The power factor is measured from the delay, in milliseconds, between Ic and Ir? ... OR (as in the past) the Active and Reactive Power values ​​are calculated from the values ​​of It and Ir, to then calculate the cosine value of phi ? ... (and consider THIS RESULT as the tangent of delta).
@anujdubey4367
@anujdubey4367 6 ай бұрын
What is the difference between frequency variation and no suppression?
@ImranAli-gq2kb
@ImranAli-gq2kb 2 жыл бұрын
Sir I need change 10 Delta screen Where I found this screen I need screen please help me guide me
@Python-bu9dc
@Python-bu9dc 3 жыл бұрын
كيف ذا طلعلي وعطيته لايك؟
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
Tan Delta Testing (DF or PF) Explained - Part 3 - UST and GST modes
22:18
Exploring Power Factor / Dissipation Factor Testing
46:36
Protec Equipment Resources
Рет қаралды 4,4 М.
Transformer Turns Ratio Test - Protec Equipment Resources
29:47
Protec Equipment Resources
Рет қаралды 33 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,2 МЛН
Flawless PCB design: RF rules of thumb - Part 1
15:45
Hans Rosenberg
Рет қаралды 100 М.
Hybrid Power Systems! | Real Life Power Armor (Part 4/6)
22:02
Hacksmith Industries
Рет қаралды 826 М.
Bushings C1C2 TechByte
16:49
National Training Center
Рет қаралды 424
Tan Delta Webianr for Beginners
1:34:58
Andrej Sepcic
Рет қаралды 9 М.