No video

How to Read Ohms on a Compressor

  Рет қаралды 89,196

Lennox Learning Solutions

Lennox Learning Solutions

Күн бұрын

Пікірлер: 82
@user-qv9cm3on7b
@user-qv9cm3on7b 11 ай бұрын
Hey I'm an HVAC I use your videos all the time to teach my class start run common thanks a lot
@olivetree633
@olivetree633 3 жыл бұрын
Thank you for this informative video. You explained it with details better than other videos I've watched before. I felt like I was in a class room listening to an instructor who cares about teaching his students. Awesome.
@jollyscaria1922
@jollyscaria1922 2 жыл бұрын
High estand medium comaon fater vstarting .highest and lowest comon facter runing. Medium and lowest comon facter comon . Comon. Expls Resistance bet ween 1.and2=50ohms.ighest Resistanc between 2 and3 30ohms .medium Resistace bet ween 1 and 3 =20 ohms .lowest
@nomis204
@nomis204 2 жыл бұрын
This is by far the clearest and most useful explanation on how to test a compressor that I have seen. Nice job, thanks.
@MrAgoniatis
@MrAgoniatis 3 жыл бұрын
Thank you for a plain and simple explanation for someone that has no experience in HVAC. GREAT JOB KEEP UP THOSE GREAT VIDEOS.!
@FlextheJuvat
@FlextheJuvat 3 жыл бұрын
This video did an excellent job explaining the relationship of those three pins. Doug has a real knack for teaching. Thanks for the video!
@cgtotty
@cgtotty 3 ай бұрын
Thank You, Sir ! A clear, concise, easy to understand video. Job well done !
@spiffiestsquid481
@spiffiestsquid481 Жыл бұрын
Haven't done it in awhile I've had an office job, needed a refresher. Thanks
@jeffreymaupin6398
@jeffreymaupin6398 2 жыл бұрын
Wonderful presentation! Nearly all residential homes have condensers clogged with dust, and compressors covered with dust. Hopefully more of us will make the effort to clean these.
@Mike-01234
@Mike-01234 Жыл бұрын
Actually, the evaporative coil is what gets clogged with dust more than the condenser coil. People put those highly restrictive filters on so dust is sucked in from the attic through leaks in the duct work goes into your evaporative coil. It's easy to clean the dust a I use one of those pumps with distilled water washes the dust right out.
@Mike-01234
@Mike-01234 Жыл бұрын
Thanks for the video I had an AC man tell me my compressor was dead I needed a new unit. I told him I wanted him to OHM test like you did suddenly he claimed his meter was broken. I asked him how he knew my compressor had failed he said it won't start I told him could be the capacitor. He said didn't have the part and left. I called another tech he came out I told him what this other guy said he did the ohm test, and my compressor was good the cap was bad replaced the cap and it worked. So many crooked AC guys here in Phoenix they know in the summer you do anything to get that AC turned back on.
@matthewlund5252
@matthewlund5252 11 ай бұрын
Awesome. This is a good video. Short and accurate.
@awatule
@awatule 2 ай бұрын
Good job homey
@robertwilliams6288
@robertwilliams6288 2 жыл бұрын
Thank you for drawing it out an explaining it easier to understand how to ohming out a compressor new hvacr student.
@stabgaming8158
@stabgaming8158 3 жыл бұрын
I'm just learning HVAC and this helped a lot
@jbourdier6824
@jbourdier6824 3 жыл бұрын
Your explanation was great, clear and easy to understand, keep up the good job.Thanks
@kckcmctcrc
@kckcmctcrc 2 жыл бұрын
Thank you! I heard a guy say the reading should be the same between the 3 points. Was thinking I had something wrong because one of my readings was a lot higher. This makes sense. Thanks again.
@robertcherry4971
@robertcherry4971 2 жыл бұрын
Will be the same on a three phase compressor . For example all three pins may be 3 ohms. The compressor depicted here was a single phase compressor and that is how the pins ohm out on a single phase.
@windturbineclimber5412
@windturbineclimber5412 4 жыл бұрын
Im a electrician studying to get into appliance repair. This video just clairfied a question I had. Thanks
@valourexonerated7046
@valourexonerated7046 4 жыл бұрын
An electrician earning twice as much as a 1ph appliance technician. Lol yeah you ok
@dledesma6675
@dledesma6675 Жыл бұрын
Thanks for taking the time, really helpful
@Tito_hvac
@Tito_hvac Жыл бұрын
Excellent video. Simple and clear 👌
@bonganiedwardmthethwa6455
@bonganiedwardmthethwa6455 Жыл бұрын
Thank you for a clear detailed video.
@obfuscated3090
@obfuscated3090 4 жыл бұрын
Good training video, simple and clearly explained. (I'm a retired aircraft mech and avionics tech but new to t-shooting my heat pump. )
@kevinbarker386
@kevinbarker386 5 жыл бұрын
Very good description of ohms values on a single phase compressor. 3 phase is equal.
@abibodlogistics
@abibodlogistics 4 жыл бұрын
Thanks so much for this wonderful video,it is so detailed and explanatory that even a lay Man can understand it.As a matter of fact you remind me of one of my Professors when I was in school years back,when he teaches you, it is like he opens your head and pour in the course.
@johnwhite1608
@johnwhite1608 2 жыл бұрын
great explanation made easy to understand
@PaulGloria-mm2tn
@PaulGloria-mm2tn Жыл бұрын
thank you sir .
@alfonsobenitez8574
@alfonsobenitez8574 2 жыл бұрын
Good job brother. Well explained.
@evancornelius9840
@evancornelius9840 2 жыл бұрын
Dude awesome video. Thanks for you help, you make a good teacher.
@mohamedsh4093
@mohamedsh4093 2 жыл бұрын
Amazing explanation brother please continue what you are doing.
@phatsacz20003
@phatsacz20003 5 ай бұрын
on point video
@nickalesroman3108
@nickalesroman3108 4 жыл бұрын
Very good video the chart you created made me understand so much better.
@sharifbyrd1354
@sharifbyrd1354 6 ай бұрын
Thank you
@nikolaosstavrou5327
@nikolaosstavrou5327 3 жыл бұрын
thank you sir for the info now I have to replace my compressor!
@brettbeougher295
@brettbeougher295 3 жыл бұрын
Great simple and understandable...thank you
@timothyjerry2455
@timothyjerry2455 3 жыл бұрын
Great breakdown. Thank you.
@jcmarentes5046
@jcmarentes5046 2 жыл бұрын
Very usefull and simple thanks
@jeffreykrawczuk4526
@jeffreykrawczuk4526 2 жыл бұрын
great lesson Thank you
@juanyepez3168
@juanyepez3168 3 жыл бұрын
Thanks for such great video
@PJ-ee5mc
@PJ-ee5mc Жыл бұрын
Great info. Thank you. I do have a quick question though: My heat pump's compressor reads as follows (at the unit itself): C+R = 1.0. C+S = 1.2 R+S= ONLY 1.4 when it seems that it should add up to 2.2 based your example. Does this mean I have a potential problem with my compressor?
@darthruiz8851
@darthruiz8851 Жыл бұрын
I got the same question
@marcdorizar5742
@marcdorizar5742 Жыл бұрын
very well explain sir.. thanks a lot.
@pitagoras1966
@pitagoras1966 2 жыл бұрын
excellent video, nice thank you!
@FoUoCoKYOUTUBE
@FoUoCoKYOUTUBE 2 жыл бұрын
good video
@babarfarid1495
@babarfarid1495 3 жыл бұрын
What should be running winding resestenc and starting winding resestenc of a ok refrigerator compressor
@jag317
@jag317 2 жыл бұрын
Kept very simple. Great job.
@saltrue1555
@saltrue1555 4 жыл бұрын
That was very very instructive thank you very much
@jmc6940
@jmc6940 12 күн бұрын
Have you ever seen high resistance on windings that were just over by a couple ohms? But when you add them up they are correct accross start and run?
@Ok-ci3lg
@Ok-ci3lg 4 жыл бұрын
This is best video. Thank you so much
@abrahamvaro5482
@abrahamvaro5482 4 жыл бұрын
Super very nice video thanks
@MrChipBryant
@MrChipBryant 5 жыл бұрын
Thank you Sir for sharing your knowledge!
4 жыл бұрын
This is great, thank you. Could you say how to determine if a compressor is THREE PHASE COMPRESSOR or single phase? Using a tester.
@fritzchirwa1783
@fritzchirwa1783 3 жыл бұрын
Great vid,thank u
@user-zi9ww5mt5s
@user-zi9ww5mt5s 7 ай бұрын
Great video! what readings will I get if the compressor is lock out (LRA).
@babarfarid1495
@babarfarid1495 3 жыл бұрын
How much pressure develop a good compressor
@SergioHernandez-yd7ip
@SergioHernandez-yd7ip Ай бұрын
It’s actually an open run winding. If you measure 0.L across any two points you are testing the winding that is not on your meter leads. Correct??
@johntomarai7675
@johntomarai7675 Жыл бұрын
Top one...🖒🖒🖒
@amystultz1608
@amystultz1608 Жыл бұрын
Ok. Let me ask if the meter says lo does that mean I can't use the compressor. By the way your presentation was very professional I just need to know if lo would be a bad report
@coryschritter5944
@coryschritter5944 4 жыл бұрын
Great vid
@elohorolokpa
@elohorolokpa 11 ай бұрын
Please, i need help here. My chest freezer gave me a shock. I tested the compressor and the relay with my multimeter and compressor is in good condition but my relay is bad. Could the bad relay really caused the shock from the freezer? Please, i need urgent response. Thanks
@dablackmike
@dablackmike 5 жыл бұрын
Love this!
@donmccloud1422
@donmccloud1422 5 ай бұрын
Very close? Is 34 ohms close enough to 32 ohms for a fridge compressor to be good?
@sepehrfadaei7564
@sepehrfadaei7564 3 ай бұрын
My refrigerator (Samsung RS277ACRS/XAA-0000) stopped working after a power outage. The ohm readings on the compressor are: C-S: 0.4 ohm C-R: 3.4 ohm I was wondering if such a low reading on the start winding is normal for this model. The Start Relay (thermistor, DA35-00135A) was not showing continuity (R = 1300 ohms), so I replaced it. The new one couldn't start the compressor either. When I test the new one, it also does not have continuity (R = 4000 ohms). I do no know if I got a bad start relay, or my compressor is bad, and the by pulling too much current burns the start relays. The overload protector has continuity, and seems to be fine.
@lats840
@lats840 2 жыл бұрын
Hello sifoo... As found.. C - S = 4.8 ohm C - R = 4.8 ohm R - S = 0.2 ohm Please advise...
@3niknicholson
@3niknicholson 4 жыл бұрын
Thanks, useful vid. The way you've drawn the pins C, S and R looks like my fridge compressor layout. Is it a standard convention to have the pins in this configuration?
@mobilecommunicationsnetwor5268
@mobilecommunicationsnetwor5268 4 жыл бұрын
Can you explain 240 V ? Is the ground through the chassis? Explain with happen with Start?
@Broskie-tm5jh
@Broskie-tm5jh Жыл бұрын
How about my lennox split ac compressor reading is good but not running even capacitor as well is good.tester show overload
@alfonsobenitez8574
@alfonsobenitez8574 2 жыл бұрын
The compressor could be cool down with water. What if you ohm it out and the reading show good. You turned on and the compressor overheat again and it shut off due to an thermal overload? Could it be that the high pressure switch could be bad? They are normally closed.
@BodyByBenSLC
@BodyByBenSLC 11 ай бұрын
Dose it have to add up to 5 ohms? If I test it and adds up to 1.2? What then?
@BulgarianOrphanHelp
@BulgarianOrphanHelp 4 жыл бұрын
What if I get a different but consistent ohm reading after different power cycles. For example I get 5 Ohms between all 3 measuring poles (S-C, C-R, R-S), power on, power off, read again and get 14.5 Ohms between all 3 measuring poles, power on, power off, and get 56 Ohms between all 3 measuring poles. Is the compressor broken? Should it always read the same resistance or can it vary as long as they always read the same value?
@baderfrdan447
@baderfrdan447 4 жыл бұрын
Does the decrease in the resistance value between the common terminal and the start terminal imply that the compressor is malfunctioning? Example, the resistance between the common & start is 1 while the resistance between the common & the run is 1.3 (resistance total between run & start is 2.3). Noting that the compressor needs a start capacitor to make it running. Without that start capacitor, the compressor cannot work. So, two questions are here: 1. Do these resistance values indicate an issue with the compressor? 2. Does this need of start capacitor to start the compressor indicate that there is an issue with the compressor? Thanks
@baderfrdan447
@baderfrdan447 4 жыл бұрын
but the resistance between C and S is lowest in the compressor. what do you think about this ? thanks..
@jacksonv1ll836
@jacksonv1ll836 3 жыл бұрын
is it normal that i could get a reading of something about 16ohms when i took the reading on the plug of the refrigerator?
@MrBullythecat
@MrBullythecat 3 жыл бұрын
Hello, I tested my compressor and all three readings from the pins were almost the same around 8.5 ohms, does that mean my compressor is bad?
@kefirstories7173
@kefirstories7173 3 жыл бұрын
Молодец! Спасибо!
@Ashraf-bu6ob
@Ashraf-bu6ob 3 жыл бұрын
Hello. My fridge compressor got a reading: 1) 7.5 ohm 2) 17.4 ohm 3) 24.6 ohm Is the compressor is good? Thank you..
@Sroor2023
@Sroor2023 Жыл бұрын
It’s too late but ,Yes it should be 😅
@kailash4069
@kailash4069 3 жыл бұрын
,sir ji Hindi language me bhi bnaiey na videos
@amayamarley7623
@amayamarley7623 3 жыл бұрын
😢 thanks
@SergioHernandez-yd7ip
@SergioHernandez-yd7ip Ай бұрын
It’s actually an open run winding. If you measure 0.L across any two points you are testing the winding that is not on your meter leads. Correct??
@bob_818_pedos_need_to_be_shott
@bob_818_pedos_need_to_be_shott 5 ай бұрын
Thank you sir
Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
11:06
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 24 МЛН
Throwing Swords From My Blue Cybertruck
00:32
Mini Katana
Рет қаралды 11 МЛН
Whoa
01:00
Justin Flom
Рет қаралды 54 МЛН
How to Find Start and Run Terminals
5:03
Lennox Learning Solutions
Рет қаралды 16 М.
Ohms vs. Continuity for HVAC techs
12:40
HVAC Service Mentor
Рет қаралды 104 М.
How to Test an Overheated Compressor (Diagnosis & Causes)
22:35
HVAC School
Рет қаралды 190 М.
Locked Compressors
20:13
HVAC School
Рет қаралды 113 М.
Failed Compressors - Don't JUST REPLACE IT
24:59
HVAC School
Рет қаралды 63 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 60 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 239 М.
How To Diagnose A BAD Compressor | HVAC Troubleshooting
9:46
Quality HVACR
Рет қаралды 187 М.
How to check the windings of a refrigeration compressor
4:23
grayfurnaceman
Рет қаралды 484 М.
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 24 МЛН