How To Run PVC Pipe Through Walls & Floor Joists - Plumbing Vent & Drain Slope

  Рет қаралды 26,012

Benjamin Sahlstrom

Benjamin Sahlstrom

Күн бұрын

Milwaukee Super Hawg: amzn.to/3rpyzGx
Big Hawg Carbide Bits: amzn.to/48ezES9
PVC Glue I Use: amzn.to/3PH3YxA
Primer I Use: amzn.to/3PGeLIg
In this video we discuss how to run rigid pipe through floor joists while making as few cuts as possible.
Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thanks for your support!
Blessings,
Ben

Пікірлер: 48
@JCWise-sf9ww
@JCWise-sf9ww 8 ай бұрын
Ben, your Videos are very educational about pluming, electrical wiring and heating/AC. So that's how you run PCV piping in the wall.
@pikeahontis1996
@pikeahontis1996 3 ай бұрын
Great job again. Your videos are always informative and easy to follow lalong. Keep up the good work!
@saltbeltupstateny4857
@saltbeltupstateny4857 9 ай бұрын
A trick we’ve used for years, with the approval of the homeowner, depending upon the exterior finish of the dwelling, Loosen a portion of siding, and drill a corresponding hole through the box beam framing . You’ll be able to slide any length you need ,with no joints…. It’s reall fast.
@BenjaminSahlstrom
@BenjaminSahlstrom 9 ай бұрын
Absolutely
@DontLookBehindYou1
@DontLookBehindYou1 3 ай бұрын
I've wanted to do that so many times
@kpmac2971
@kpmac2971 9 ай бұрын
Hey Ben, the printing on the PVC should be facing down, not up. That way the inspector can quickly confirm that the proper size and type of material had been used.
@user-cx4pw3tf7h
@user-cx4pw3tf7h 9 ай бұрын
Good inspector should be able to tell the pipe size by looking at it
@kpmac2971
@kpmac2971 9 ай бұрын
That’s definitely true. But not all inspectors are good inspectors. It’s not worth taking the chance. Better safe than sorry. There is little value In wasting time arguing with a code inspector-or educating one-when you can show your work.
@BenjaminSahlstrom
@BenjaminSahlstrom 9 ай бұрын
Interesting thought. Never encountered an inspector who requested that.
@gerryclark2063
@gerryclark2063 9 ай бұрын
Agree, and you can line up the printing and make it all face the same way for a 'good' look.
@FreeAmerican-mm2my
@FreeAmerican-mm2my 9 ай бұрын
Agreed. My inspector will fail you if it is not visible.
@zekenzy6486
@zekenzy6486 9 ай бұрын
Great Video. Thank you for sharing. Have a nice weekend
@watermanone7567
@watermanone7567 9 ай бұрын
Do you ever install a metal joist brace under a hole thru the joist for added strength. Some states require it. Thanks for a great video.
@jameshancock
@jameshancock 9 ай бұрын
A little heat helps pvc bend. Just don’t fold it. When it cools it will be thee same strength as original.
@klpittman1
@klpittman1 8 ай бұрын
On longer runs it's hard to bend 1.5 or 2 inch PVC and pull or push through a series of holes, especially when working alone. Run a rope through the pipe and tie something across the end of the pipe so you can pull from the end you're trying to guide through the next hole.
@TurboVisBits
@TurboVisBits 5 ай бұрын
just the tip i was looking for!
@jimyeats
@jimyeats 9 ай бұрын
Best answer; plan your house accordingly so that your DWV is either just going up through wall cavities or running parallel with floor joists (other than the occasional short little detour). I can't imagine in a new construction home trying to make long runs of rigid PVC perpendicular through a bunch of floor joists or through studs.
@andrewalexander9492
@andrewalexander9492 9 ай бұрын
You don't always have that luxury when you're handed the plans for the building.
@jimyeats
@jimyeats 9 ай бұрын
@@andrewalexander9492 Oh no, I'm not talking about you the tradesman, I'm talking about the designer and builder thinking about that well beforehand. That's the sign of a good team.
@andrewalexander9492
@andrewalexander9492 9 ай бұрын
@@jimyeats OK, gotcha. Yeah, it would be nice if the architects/designers etc. would think about that.
@miked19831988
@miked19831988 9 ай бұрын
what dou do when the run of pipe is longer than what the 1/4" per foot will allow in the material width
@DontLookBehindYou1
@DontLookBehindYou1 4 ай бұрын
Ohhhhh... Good question
@Zarathustra-H-
@Zarathustra-H- 2 ай бұрын
How about softening the PVC with a heat gun, bending it, and then straightening it once it is inserted?
@user-hb7nn7hm1q
@user-hb7nn7hm1q 3 ай бұрын
Did you take your vent pipe horizontally outside? If so, did you turn it up afterwards?
@jamescollins8148
@jamescollins8148 9 ай бұрын
PVC heater!
@donsmith4170
@donsmith4170 7 ай бұрын
if its a vent line then shouldn't you go higher with the PVC?>??
@disorganizedorg
@disorganizedorg 9 ай бұрын
Maybe fill the long lengths of PVC with something hot (sand is common, but maybe boiling water) to make it flexible enough to bend a bit more easily? Not sure if that's more work than using shorter pieces.
@austincox1239
@austincox1239 5 ай бұрын
Who is filling PVC with hot sand?
@gfy2979
@gfy2979 8 ай бұрын
In my home I avoid going through joists. Its much better to not do this and have some sort of dropped down ceiling. that should be the norm
@nhzxboi
@nhzxboi 9 ай бұрын
Drill holes too large and it makes for great mouse runs especially if the run leads to where the food is. That happened at my brother's house. Little devils ate through the hot water dish washer PEX(branched from PVC) and flooded his garage. Mice like certain kinds of plastic. Maybe fill the gaps with foam?
@BenjaminSahlstrom
@BenjaminSahlstrom 9 ай бұрын
Mice are terrible.
@DougsHomestead
@DougsHomestead 9 ай бұрын
I find it easiest to hire it out to someone like you😂😂😂😂😂😂😂
@gowenrv3762
@gowenrv3762 9 ай бұрын
I know there's probably no way to prevent it.... but it seems that you are losing wall integrity when you drill such large holes in the studs or joist. At least I've always thought so. Great Video...
@andrewalexander9492
@andrewalexander9492 9 ай бұрын
As far as the joists (Joists are the ones which support the floor) if you drill holes in the joists in accordance with the code (Benjamin, mentioned the guidelines) the hole really does not weaken the joist much. A joist is a beam, and the middle of a beam doesn't have much stress in it. The majority of the stress is concentrated in the top of the joist, and in the bottom. So drilling through the middle avoids the high stress areas.
@gowenrv3762
@gowenrv3762 9 ай бұрын
Thanks for the reply @@andrewalexander9492
@nolansmokes
@nolansmokes 8 ай бұрын
@@andrewalexander9492yeah and I believe it’s the top and bottom 2 inches that you can’t drill through
@adrianchavira5223
@adrianchavira5223 9 ай бұрын
If this was my house and I need to vent two or three places . Would rather go through the ceiling and have 3 o more vents than having to drill the whole house. Work smart not hard!!
@donaldshimkus539
@donaldshimkus539 8 ай бұрын
Or, get into attic space asap and connect them there and run one vent through roof (if possible).
@rsz90182
@rsz90182 6 ай бұрын
I don't like cutting up PVC like that into a million pieces. I am sure it will fail inspection.
@austincox1239
@austincox1239 5 ай бұрын
Why would it fail inspection?
@hawk1481
@hawk1481 9 ай бұрын
Who uses PVC anymore?
@MAGAMAN
@MAGAMAN 9 ай бұрын
Good builders. The same good builders that use copper instead of pex.
@FreeAmerican-mm2my
@FreeAmerican-mm2my 9 ай бұрын
My area uses PVC.
@andrewalexander9492
@andrewalexander9492 9 ай бұрын
Well, the alternative would be ABS, if it's allowed in your jurisdiction, and everything said in this video would apply to installing ABS drains and vents under the same circumstances. What was your point, exactly?
How To Drill Holes Through Floor Joists
12:58
Benjamin Sahlstrom
Рет қаралды 67 М.
Каха инструкция по шашлыку
01:00
К-Media
Рет қаралды 8 МЛН
How to bring sweets anywhere 😋🍰🍫
00:32
TooTool
Рет қаралды 39 МЛН
Plumbing Slope Rule and Why it is CRITICAL
10:08
Todays Task
Рет қаралды 83 М.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
Drilling Holes: Stud Frame Walls
5:44
Plumber-Tom
Рет қаралды 29 М.
Drainage Pipe Slope and Trench Depth Calculation
8:40
Everyday Home Repairs
Рет қаралды 155 М.
How to Vent Plumbing
15:38
Ask the Builder
Рет қаралды 1,3 МЛН
How To Stub Out PEX Plumbing for PEX-A & PEX-B
8:23
Fort Knox Co.
Рет қаралды 90 М.
How to undo a glued PVC fitting
12:06
PVC Tips and Tricks
Рет қаралды 2,8 МЛН
Leveling a Sloping Bedroom Floor
21:26
Wood U Make It
Рет қаралды 516 М.
Prohibited Fittings & Connections
17:04
Edward Logan
Рет қаралды 41 М.