How to Wire a Pentair SUPERFLO® VS Variable Speed Pump

  Рет қаралды 83,300

Swimming Pool Tips, Reviews & How To - SPL

Swimming Pool Tips, Reviews & How To - SPL

Күн бұрын

Пікірлер: 73
@MiklaDfar
@MiklaDfar Жыл бұрын
Excellent video. My only criticism would be to turn the wires around so that when you tighten the screw, the wire loop does not try to open.
@SPL
@SPL Жыл бұрын
Roger that. 👍
@TheLarryBrown
@TheLarryBrown 10 ай бұрын
@@SPL Really really odd to think of someone doing electrical work that does not know that and already practice it.
@DanielJavier-c5t
@DanielJavier-c5t 7 ай бұрын
Also replace wires in this case the insulation is in bad shape.
@lawoull.6581
@lawoull.6581 5 ай бұрын
Also,use an Acme 5x24 series with a transducing capacitor with a built-in temporal displacements..pls remember next time🎉.. happy 2025 brah..ty
@jasondimartino
@jasondimartino 2 ай бұрын
You are the man, perfect explanation. Thank you for sharing
@billybartley5486
@billybartley5486 4 жыл бұрын
Okay, for those that have Aqucal PoolPilot SWG this is what the tech at Aquacal said: Wire the VS pump just like SPL did in the video. The pump is designed to run 24/7, calibrate the % as required to keep chlorine level within guides. The SWG is designed to run 15 minutes out of every hour. Let's say you set it at 50% that means it's generating chlorine 7.5 minutes per hour. It will NOT affect cell wear. If the pump should shut off the SWG will shut down, it has to have water flow (hence the flow switch) to turn the cell on. He said to test chlorine initially closely to calibrate the % and let it run. And it works the same for most if not all VS pumps, meaning if they are wired like in this video. Some are designed with wifi, remote, etc. I hope this helps somebody with this issue, it works well for me!
@geterdunn2733
@geterdunn2733 8 ай бұрын
Thank you for posting this, very helpful.
@jonrasmussen4284
@jonrasmussen4284 7 жыл бұрын
Excellent, simple, clear and professional. Thank you!
@SPL
@SPL 7 жыл бұрын
Thanks!
@lawoull.6581
@lawoull.6581 5 ай бұрын
Awesome video 😮
@benyrizarry273
@benyrizarry273 3 жыл бұрын
Great vid thanks. Was wondering how to wire my pump and u made it super easy!!
@Stewada2010
@Stewada2010 6 жыл бұрын
Question I just installed this pump and my timer has my salt chlorinator and Heater on the same timer. Is it possible to wire the pump to he power input side of the time and then sync the timer for the pool pump and the timer my chlorinator and heater are on so that when my timer for my pool kicks of it doesn’t resent my pump timer. Does that make sense?
@meganmoss3646
@meganmoss3646 7 жыл бұрын
i just wanted to say thank you for the videos. i always look at your videos if i have any doubt in what i'm doing.
@SPL
@SPL 7 жыл бұрын
Thanks!
@ialien2077
@ialien2077 4 жыл бұрын
The Pentair rep. told me that it comes pre-wired to 220v, and that I'd have to re-connect the wires to the lower voltage; I have 120v. Interesting that both you and the manual say the pump automatically adjusts to whichever voltage it's connected to. I wonder if he misunderstood which model I was talking about. I just had it delivered, and it's the Superflo VS (342001).
@SPL
@SPL 4 жыл бұрын
I bet he just didn't hear you mention it was a Superflo VS. Probably thought you meant the regular Superflo single speed. It will self adjust. 👍
@EdgarMontiel-s3c
@EdgarMontiel-s3c 3 күн бұрын
I'm replacing a Pentair 342000 pump with a Pentair 342001. The old pump only had two black wires connected to it, with no ground and bounding wire. Does this sound right?
@SPL
@SPL 2 күн бұрын
It sounds like the installer previously cut some corners. Why not purchase a new wire whip with the correct wiring.
@lsohadi01
@lsohadi01 Жыл бұрын
Great video. Question ; can the pool timer be completely eliminated since the pump has its own timer ? If so how do wire the pump to the power from the breaker?
@SPL
@SPL Жыл бұрын
Yes, you would just wire it to a junction box with a GFCI attached to it.
@eduardomartel1530
@eduardomartel1530 4 ай бұрын
What about when you have 4 wires 2 lines ground and neutral? Just cut and tape the neutral?
@SPL
@SPL 4 ай бұрын
A bit odd. But I think that would be the correct solution.
@lostonlongisland6845
@lostonlongisland6845 6 жыл бұрын
since 2011 hardwired or cord connected pumps rated 110 or 220 volt must be gfci protected..Pentair recommends using their own breakers pa220gf for most installs
@tonyhellcat7273
@tonyhellcat7273 7 ай бұрын
Does anyone know the size of the hole / thread for the plastic elbow? 3/8” or 1/2”? Thank you!
@bluedrew
@bluedrew Жыл бұрын
Is the display/control panel reversible? Mine is upside down when facing the pump. Ground not connected!
@SPL
@SPL Жыл бұрын
That is weird. But yes, you should be able to turn it.
@bluedrew
@bluedrew Жыл бұрын
@@SPL So on the older, circa 2018 vs, it is not reversible. I tried. There is indent for the cable input. The cover only fits one way. Then I tried to reverse the inset display....turns out it only fits one way.
@jkutyna
@jkutyna 3 жыл бұрын
So how do you set this to use the intermatic timer for when to run your pump during the week? You just simply said that you remove that and keep it on at all times, assuming the user wants to let the pump itself set it's run cycle. I don't want that I want the intermatic to turn it on and off. How do you set the pump then to just run when it gets power and so forth like a normal pump should?
@SPL
@SPL 3 жыл бұрын
Just match the intermatic on-off trippers with the pump programming.
@MrDboydeluxe
@MrDboydeluxe 5 жыл бұрын
Do you happen to have a tip or trick to push the wiring through the elbow fitting? easy to pull out but putting old wiring back in is frustrating,
@SPL
@SPL 5 жыл бұрын
I know. There isn't much room. It depends. I sometimes pull them through one at a time. I have also bundled them together to get them in but it is a tight fit no matter what you try to do.
@WalterAplicano
@WalterAplicano 6 ай бұрын
What voltage do I connect to it?
@SPL
@SPL 6 ай бұрын
Doesn't matter. Works on both 120v or 240v
@MrDboydeluxe
@MrDboydeluxe 2 жыл бұрын
Can you wire a Pentair Intelliflo the exact same way into a T104M time clock? just take off the trippers and push lever to on? the Superflo VS are getting tougher to find at a reasonable price
@SPL
@SPL 2 жыл бұрын
Yes. You can do that.
@anabelfernandez
@anabelfernandez 4 жыл бұрын
Hi, thank you so much for posting these videos! You have saved me so much time and money as I am a new pool owner. I just finished installing this exact pump brand new and it ran great but when I was switching between modes it gave me error 1a. I was able to fix the issue by turning it on and off but later it happened again and I cannot get it to work anymore. The manual says to disassemble the pump and check impeller or mechanical seal. But it is brand new. I also noticed my heater will no longer power on but I don’t know if that’s related.Any idea what it could be?
@SPL
@SPL 4 жыл бұрын
Could be the breaker tripped.
@anabelfernandez
@anabelfernandez 4 жыл бұрын
@@SPL I actually checked the breaker and everything seemed fine there. I turned it off a couple of hours and everything is working now.
@chewiebaca8909
@chewiebaca8909 7 жыл бұрын
Like your channel ,I have a question when you backwash will it tear the cloth filter. Thank You
@SPL
@SPL 7 жыл бұрын
Backwashing wears out the grids faster in my opinion. They fill up with water from the inside out to push all the stuff off during backwashing.
@brianonthego
@brianonthego 6 жыл бұрын
Thank you.
@ShampooWow
@ShampooWow 7 жыл бұрын
Awesome video! I like it
@MrDboydeluxe
@MrDboydeluxe 7 жыл бұрын
This variable speed pump doesn't need any electrical upgrade? a standard Intermatic T104M and double pole circuit breaker is good enough?
@SPL
@SPL 7 жыл бұрын
Yes. No electrical upgrade needed.
@gamingtrading7119
@gamingtrading7119 5 жыл бұрын
What gauge is the wire I need to replace mine but no one says what wire we need
@SPL
@SPL 5 жыл бұрын
10-Gauge 3-Conductor Non-metallic Liquidtight A/C Whip
@beegee619
@beegee619 6 жыл бұрын
I have a single speed pump that is controlled by a timer. When the timer turns on, it also turns on the salt system. If I replace the pump with a variable speed pump and leave the old timer always on, is there any worry with the salt system always being on too?
@SPL
@SPL 6 жыл бұрын
Good question. You don't want the salt system on when the pump is off, that is for sure. I will have to check for my rep for you to see how you can do that with the Superflo VS. I know the Jandy 2.0 HP VS pumps has an AUX slot for a salt system to prevent that but not sure about this model. I will let you know.
@61johnab
@61johnab 6 жыл бұрын
I have the same setup with my pool. Very interested in your answer to this.
@SPL
@SPL 6 жыл бұрын
According to Pentair you cannot connect the VS Pump to the Intermatic Timer and also control when the Salt Cell turns on as it will be on if the timer is "on". Of course it is not good for the cell to be on while the pump is off. The only thing he suggested is to purchase the Sun Touch Automation which is their least expensive. With that you can put the pump on one relay and the salt system on another.Or purchase a seperate timer for the Salt System, but then you have to make sure it will turn on only when the pump is set to run. The only pump that can accommodate a salt system without automation is the Jandy 2.0 HP VS pumps. They have a AUX relay built right into the pump. I filmed a video on this feature. Pentair has no AUX relay in their VS pumps at the moment.
@SPL
@SPL 6 жыл бұрын
According to Pentair you cannot connect the VS Pump to the Intermatic Timer and also control when the Salt Cell turns on as it will be on if the timer is "on". Of course it is not good for the cell to be on while the pump is off. The only thing he suggested is to purchase the Sun Touch Automation which is their least expensive. With that you can put the pump on one relay and the salt system on another.Or purchase a seperate timer for the Salt System, but then you have to make sure it will turn on only when the pump is set to run. The only pump that can accommodate a salt system without automation is the Jandy 2.0 HP VS pumps. They have a AUX relay built right into the pump. I filmed a video on this feature. Pentair has no AUX relay in their VS pumps at the moment.
@beegee619
@beegee619 6 жыл бұрын
Swimming Pool Tips, Reviews & How To -MrDgvb1 thank you for looking into it! Will the flow valve on the aquarite system keep the salt system from turning on if there is no flow?
@ThanhLâmThánhNhạc
@ThanhLâmThánhNhạc 7 жыл бұрын
Hi, I had a Whisperflow and i'm replacing it with this Superflow VS. The Wisperflow wire has Green, Black, Blue and Blue wire. How should I connect it to the Superflow?? Thanks!!
@SPL
@SPL 7 жыл бұрын
Strange. You will have to call Pentair on Monday and ask them because I am not sure. 800-831-7133
@ThanhLâmThánhNhạc
@ThanhLâmThánhNhạc 7 жыл бұрын
I think it's 4 wires because the wires come from an Intermatic timer, with Green = ground, black = hot, and the 2 blues are from Circuit 1 and Circuit 2. I end up disconnect 1 blue from Circuit 2, and only connect the Green to green, Black and Blue from Circuit 1 to the L1 and L2 of the Superflow VS. Hopefully that's the right wiring.
@alejandropalazuelosleis.185
@alejandropalazuelosleis.185 7 жыл бұрын
Everything was ok on the wiring except always is better to replace it the old wires with new wires that making the pump working better professional installation. Alex Pool's.
@ctop1311
@ctop1311 7 жыл бұрын
i enjoy every video you post thank you ..... i think things are getting a little to technological in the pool business all you need is filtration & proper chemistry my company is the one that set in motion all these new pumps & regulations/suction grates? let me know if any of your customers absorb any responsibility thanks...dave in Connecticut
@stylz711
@stylz711 Жыл бұрын
I got two back wires and one red.
@SPL
@SPL Жыл бұрын
It's probably not wired up to code. Sometimes electricians use odd colored wires. I would assume the 2 black or hot but not sure.
@whitemok
@whitemok 5 жыл бұрын
David is no ka oi but he forgot his gloves. hehe...
@fastfreedom
@fastfreedom 6 жыл бұрын
I did everything but when I turned the breaker back on and turned on the timer, there was no power to the pump. I checked the wires on the back of the motor and the intermatic timer wires too. They seem tight and not blown or damaged. The intermatic timer is moving and I can see the gears moving so I think it's getting power. The lights on the pumps display will flash green a couple times every 3 or 4 seconds but wont stay on. The LCD display doesn't flash 1200 or come on at all. Only the green lights will flash for a half second and go off. I haven't used a volt tester yet. But it seams like the timer box is getting power just not the pump. Any suggestions
@SPL
@SPL 6 жыл бұрын
What was the issue with your old pump? did it burn out? And how old is your breaker box?
@ricomartinez8136
@ricomartinez8136 6 жыл бұрын
Not sure if it burned out. When I turned on the timer manually for the old pump, there was only silence. It didn't turn on. No humming or sound at all. So today I put in the new superflo vs. the breaker seams ok. House was built in 2006. I just bought a volt tester and tested the load and line on the timer. Both read 240. Then tested the back of the motor and it read 0. So I'm guessing the wires from the box to the pump are bad and I might have bought a new pump and motor for nothing because it's just the wiring. Or maybe the pump burned out and effected the wiring. Not sure. But the pump was old and this new VS should be better anyway.. Should I replace whip next maybe?
@SPL
@SPL 6 жыл бұрын
It's possible that is the cause of the old motor burning out - a VS pump is much better. Install a new Conduit - not very expensive. See if that does the trick.
@ricomartinez8136
@ricomartinez8136 6 жыл бұрын
Thanks sir. I've watched alot of your videos. They are by far the best. The camera angles, editing and explanation are top notch. Thanks so much for taking the time out to reply. I know you must be busy during the summer!!!
@SPL
@SPL 6 жыл бұрын
Sure thing - I am very busy, busy. Let me know if the new conduit did the trick.
@johnodell343
@johnodell343 5 жыл бұрын
Anyone ever had an error code 18?
Pump Impeller & Diffuser Issues, Pool Pump Not Priming Part 6
9:14
Swimming Pool Tips, Reviews & How To - SPL
Рет қаралды 397 М.
How To Wire a Pool Pump, Pool Pump Installation Part 1 of 2
4:52
Swimming Pool Tips, Reviews & How To - SPL
Рет қаралды 486 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 39 МЛН
HOW TO PROGRAM PENTAIR SUPERFLO!
6:08
Pool Tips for Dummies
Рет қаралды 34 М.
How to Install a Pentair SuperFlo VS Pump and or SuperFlo VS PowerEnd
21:32
Cleaning the nastiest piano I have EVER seen
11:47
The Piano Doctor
Рет қаралды 96 М.
How To Program A Variable Speed Pump Schedule
8:09
Swimming Pool Steve
Рет қаралды 68 М.
Pentair SuperFlo Variable Speed Pump Connected To EasyTouch Panel
6:55
John The Pool Expert
Рет қаралды 37 М.
How to Change Seals on a Pentair SuperFlo!
13:17
Hallmark Pool Supplies
Рет қаралды 45 М.
Single Speed Vs. Variable Speed Cost Comparison
17:28
Swimming Pool Steve
Рет қаралды 60 М.