How to wire multifunction 3 phase power meter and current transformers - NEMO (subtitles)

  Рет қаралды 30,625

AboutElectricity

AboutElectricity

5 жыл бұрын

Find out how to wire 3 phase power meter to measure current, voltage, power, power factor, frequency, energy, THD etc.
It is panel mounted multifunction meter but in similar way you can connect any other type of multifunction meters.
Like, subscribe and don't skip the ads :)
👋 FACEBOOK👋
*******************************
Subscribe our page to be up to date
/ aboutelectricity-29164...
⚡🛠️ THINGS YOU MAY NEED 🛠️⚡
*******************************
Phase monitoring relay : amzn.to/2AxAqM0
Contactors : amzn.to/2CTCYW9
32A fuse holders : amzn.to/2GRVd2z
Disclaimer:
I can't under any circumstances be held liable for any possible personal injury or material damage resulting from the use of this example.
Forward by Declan DP Music / declandp
Licensing Agreement 2.0 (READ)
www.declandp.in...
Finesse by Peyruis / peyruis
Creative Commons - Attribution 3.0 Unported - CC BY 3.0

Пікірлер: 20
@AboutElectricity
@AboutElectricity 5 жыл бұрын
What do you think about this video ?
@ChinaFriedPanda
@ChinaFriedPanda 2 жыл бұрын
Suprisingly helpful, thank you
@Elecnova
@Elecnova 3 жыл бұрын
it makes me have a clearer mind for that
@kevinbarry2294
@kevinbarry2294 4 жыл бұрын
Very good video.....great detail...
@abdullahbasher9295
@abdullahbasher9295 4 жыл бұрын
THANKS A LOT SO HELPFUL .
@hoxtonloft
@hoxtonloft 4 жыл бұрын
Great Video, super helpful
@anuruddhalogin
@anuruddhalogin 4 жыл бұрын
Useful !
@tabasumcarpentry5336
@tabasumcarpentry5336 5 жыл бұрын
GREAT VIDEO one question my running load is around 10 amps and the ct i installed is 100/5 so is it matter that the ct amp is close to the estimated load or inside the max amp range second every ct S1 terminals need to short/ grounded means the energy meters manufacturer not done this internally THANK U
@AboutElectricity
@AboutElectricity 5 жыл бұрын
1. As far as I remember 10% is the minimum.So if you have 100A CT installed and the load is 10A the CT is still within ist class.Less than 10A load = less accuracy. 2. No.You have to do it.
@tabasumcarpentry5336
@tabasumcarpentry5336 4 жыл бұрын
@@AboutElectricity Hi sir as u recommend to short the S1 terminals on the CT i did the same but when i check the energy meter manual they said S2 terminals need to short. so at first i did S1 terminals and put on power will it do any damage to the energy meter? second sir i installed the meter now on 30/5A CT and change the setting on the meter as well for the CT but when i compare the AMPS measurements between the energy meter and a clamp meter there is around 45 % difference the clamp meter is showing 1.2 amp on R PHASE and energy meter showing 0.6 amps. the CT is 30/5A but when i change the CT size in meter to 50 then the measurements between clamp meter and energy meter matches. energy meter model DIRIS A-20 Kindly give ur valuable suggestion which will clear the problem THANK U
@AboutElectricity
@AboutElectricity 4 жыл бұрын
@@tabasumcarpentry5336 ABID Abid follow socomec manual and earth S2.you will not damage the meter by earthing S1.It will only show 0A in this phase.Set the correct ct value in the meter (30).double check that CT are facing the same side(P1 to power supply).choose correct network from page 14 socomec manual an then program it (page 19).
@MAbid-zt7nm
@MAbid-zt7nm 4 жыл бұрын
@@AboutElectricity thankful to u sir. The cable is entering the CT from P1 side . The network i set is 4nbl. Three phase 4 wire non balance.
@AboutElectricity
@AboutElectricity 4 жыл бұрын
@@MAbid-zt7nm did you managed to solve the problem?
@uniquepowercorporation5662
@uniquepowercorporation5662 4 жыл бұрын
Gjb...👍
@paddykriton3475
@paddykriton3475 11 ай бұрын
Technical issue with video. There are two terminal "4"'s shown on the power meter in the video. The 2nd terminal 4 should be labelled "6"
@AboutElectricity
@AboutElectricity 11 ай бұрын
👍
@paddykriton3475
@paddykriton3475 11 ай бұрын
@@AboutElectricity the video is a very good video, just thought that terminal might cause a little confusion
@AboutElectricity
@AboutElectricity 11 ай бұрын
@@paddykriton3475 Thank you. Unfortunately I can't edit this video. I would have to delete it and repost it on yt again.
@xushenxin
@xushenxin 2 жыл бұрын
I don't understand why do you need a transformer in here?
@darcyrobinson
@darcyrobinson Жыл бұрын
Thanks, the “instructions” that come with it are a fucking joke
How to wire VFD. Altivar 312 three wire control.
4:58
AboutElectricity
Рет қаралды 34 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 604 М.
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 14 МЛН
Son ❤️ #shorts by Leisi Show
00:41
Leisi Show
Рет қаралды 10 МЛН
路飞太过分了,自己游泳。#海贼王#路飞
00:28
路飞与唐舞桐
Рет қаралды 43 МЛН
What is the Difference Between Single Phase and Three Phase???
23:11
Electrician U
Рет қаралды 576 М.
Connecting current transformers for 3 phase metering
28:57
Residual Electrical
Рет қаралды 38 М.
How to Wire an Electrical Panel - Square D
9:40
Battle of the Tools
Рет қаралды 3,3 МЛН
Three-Phase Power Explained
9:58
Raritan
Рет қаралды 1,3 МЛН
Configure Power Analyzator IME NEMO 96 HD
7:40
Scooter Simplicity
Рет қаралды 1,7 М.
Умный электрический помощник для штор
0:23
Склад дизайна
Рет қаралды 1,6 МЛН
Что делать если в телефон попала вода?
0:17
Лена Тропоцел
Рет қаралды 4,4 МЛН
Yanlışlıkla Telefonumu Parçaladım!😱
0:18
Safak Novruz
Рет қаралды 7 МЛН
Самые крутые школьные гаджеты
0:49