HVAC Condensate Safety Switch Training! 6 Types, Operation, Installation, Wiring, Testing!

  Рет қаралды 71,268

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

In this HVAC Training Video, I show 6 Types of HVAC Condensate Safety Switches, How They Work, How to Wire Them in, and Why They are Installed on Air Conditioning Systems! I show the
Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
Asurity/Diversitech Condensate Switches
www.asurityhva...
Asurity/Diversitech Condensate Pumps
www.asurityhva...
Asurity/Diversitech Condensate Pans
www.asurityhva...
Asurity/Diversitech Condensate Treatments
www.asurityhva...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• Air Conditioner CONDEN...
• Air Conditioner Conden...
• Does a Wall Mounted MI...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicet...
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicet...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtoo...
Refrigerant Charging Book and E-Book: www.acservicet...
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicet...
Our Newest Articles: www.acservicet...
Try our HVAC/R Quizzes! www.acservicet...
Our Other Resources: www.acservicet...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicet...
Our Tool List on Amazon: www.amazon.com...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtoo...
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.c...
Apple Podcasts: podcasts.apple...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #condensate #safety #switch #condensate #training #installation #testing #wiring #operation
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 82
@wayneschneyer8699
@wayneschneyer8699 2 жыл бұрын
Craig, Congratulations on having the absolute best training classes available. Your explanations are the best and the visuals are so beyond anything out there it’s amazing!! You embody the best methodology of training, explaining the theory and showing the reality of that topic. Absolutely the best. God Bless! Thank so much. ,
@lp1330
@lp1330 3 жыл бұрын
Break red if you have a digital stat and no delay in the condenser Breaking yello can cause rapid short cycling -- frying the contactor or making a scroll run backwards. Most digita stats will delay plus some go blank and alert the customer
@JM-gx7iv
@JM-gx7iv 2 жыл бұрын
And I'll just add that he's more than likely referring to ecobee or nest.. tstats that requires the a common. If it's a digital tstat thats ran off of batteries and not common.. break Y.
@firepelayo
@firepelayo 3 жыл бұрын
Craig, I can't say it enough man, the information you provided is second to none! Always clear and to the point. Nobody out there in the KZbin world is on your level, keep it coming😎
@luiselizalde6757
@luiselizalde6757 3 жыл бұрын
He is really a great teacher, despite of all the subscribers, he will get you back when you comment on his videos, we really appreciate all your effort that you do for all us, Thanks
@Silky_boi
@Silky_boi 3 жыл бұрын
You’re the man Craig! Thanks for all your help over the years.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity 3 жыл бұрын
I like all of those, except the hockey puck. It is very reliable, opens very early during a blockage. My only problems are there is no molex connector to remove for drying and drying takes too long if humidity is 90%+ like it is here all summer. One that I’ll never use again is an Aqua Guard AG-1250E. I found it burnt and melted in a plastic pan a month ago. Voltage still getting to contactor at heat pump, but no current flow. As soon as I went into the attic, I could smell burnt plastic. Very dangerous. The indoor coil had froze up and melted condensate bypassed the coil pan. Thanks for the great videos to keep all of us sharp.
@johnny.9879
@johnny.9879 3 ай бұрын
Had drained the lines and was still lit up. And still not working so after finding you video i took the switch apart and there was still water there. So soaked that part out with a towel and put back in, turned on ac and in a few minutes kicked on like normal! Thank you!!!
@johnny.9879
@johnny.9879 3 ай бұрын
Thank you do much for sharing this info. Have seen a few of your videos and helped me in my issues. I cleaned my drain line on the my ac unit but the red light still on. But will be adjusting it as you did, think that will be my problem. Also watched one on the capacitors you made. Great breakdowns!!! Thank you again!!!
@love2hvac
@love2hvac 3 жыл бұрын
I'm loving the lab set up! Your awesome! Keep up the great work!
@UltraHydrophobiccoat
@UltraHydrophobiccoat 3 жыл бұрын
It’s nice to see you here Ty!
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@christophersalazar7175
@christophersalazar7175 3 жыл бұрын
Even after being in your class I still watch your vids when I need help
@DB-zh3ti
@DB-zh3ti 2 жыл бұрын
Craig, your videos how you explain everything is easy to unserstand. Wishi there was something like this 40 years ago when I started in the field. The only thing I can suggest is that a little red or green dye in the water would have made it easier to see the water level.
@tntheatingandairllc
@tntheatingandairllc 3 жыл бұрын
Great video my friend please keep them coming 👍👍
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks for the visit
@karlschoen7297
@karlschoen7297 3 жыл бұрын
Great discussion about safety switches Always like watching the videos
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you like them!
@karlschoen7297
@karlschoen7297 3 жыл бұрын
@@acservicetechchannel always
@AA-hu9mh
@AA-hu9mh 2 жыл бұрын
The explanation is excellent. Keep up the good work and thank you for sharing your knowledge 👍
@ishalljr
@ishalljr 3 жыл бұрын
Great video per usual. Thanks.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@DavidHernandez-gt9bo
@DavidHernandez-gt9bo 3 жыл бұрын
This guy is good 👍… explains everything!
@denardprice1055
@denardprice1055 3 жыл бұрын
With the CS-2 type switch, you should drop it below the evaporator pan so that the blower can’t pull water back out and not allow it to trip when there’s a drain blockage Love your educational videos
@jimmysegovia2688
@jimmysegovia2688 3 жыл бұрын
awesome presentation Craig!!!!!! thank you for sharing!!!!.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you liked it!
@hornet224
@hornet224 Жыл бұрын
Nifty multiple float switch setup explained clearly. 🙂
@arkrainflood
@arkrainflood 3 жыл бұрын
my unit in the attic had an emergency pan of metal wherein the sides were folded upright from the bottom surface. the corners were supposed to be then sealed, but one was not. the drain tube got clogged and the condensate dripped into the pan and leaked out a corner. this was in july with high temperature and high humidity. the water puddled on top of the ceiling drywall and then leaked through a recessed light, several gallons! took an hour to diagnose the problems of the leak and the clog. and many hours to repair repaint the ceiling.
@mikew1778
@mikew1778 Жыл бұрын
Thank you for the great videos. Excellent job of presenting.
@nickdeliso7026
@nickdeliso7026 Жыл бұрын
Great video! I think I only have one in the pan. Not sure about in the unit.
@beachwave2
@beachwave2 Жыл бұрын
Excellent. Most complete video. Thanks.
@jamesreyna4252
@jamesreyna4252 3 жыл бұрын
Great video .
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@jamesreyna4252
@jamesreyna4252 3 жыл бұрын
@@acservicetechchannel just bought your ac service tech book and posters offline . Met you out in Clermont at the symposium. Thanks for all y’all do !
@ajscharper656
@ajscharper656 3 жыл бұрын
well done, instructive vid....
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@edilsonserafim4784
@edilsonserafim4784 3 жыл бұрын
Craig thank you for being you.
@ctorres441
@ctorres441 3 күн бұрын
Thanks Craig , is amazing the way than you explain it, just my question is, these examples are with devices 24 volts AC and serial connection is that right?
@rogerf3622
@rogerf3622 3 жыл бұрын
Great detail.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you think so!
@juanacosta2788
@juanacosta2788 2 ай бұрын
Great video
@eliasdiar3333
@eliasdiar3333 3 жыл бұрын
After a period of time, the sensors stop working due to dust and dirt, but if the sensors were electronic and did not enter water, it was better. Thank you.
@hashimshams9633
@hashimshams9633 3 жыл бұрын
Thank you, Thank you, Thank you sir
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
You are most welcome
@MrRene1968
@MrRene1968 3 жыл бұрын
awesome information
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad it was helpful!
@viper22304
@viper22304 2 ай бұрын
awesome video. thanks for sharing. how many safety switches do i one need?
@RonMurakami
@RonMurakami 2 жыл бұрын
Very well done video, thanks for posting.
@texasbullshit
@texasbullshit Жыл бұрын
Always appreciate your instructions. I have a question about the DiversiTech CS-1, this flow swithch is always turned red led on even thogh no water and no flow. is it defective switch? how to check with multi meter, Thank you
@Bebik22
@Bebik22 2 жыл бұрын
best video ever
@JoshuaAlenza
@JoshuaAlenza 3 жыл бұрын
Love your videos! Can you do one on zone systems and trouble shooting zoneboards and dampers please?
@The12stonesfan
@The12stonesfan Жыл бұрын
Hey Craig, so basically you wired the three in series because if at any point one of the three open it'll still shut off the outside condenser. I prefer to break red in my opninion, so it'll shut off everything
@sandywilson8169
@sandywilson8169 Жыл бұрын
Good inf0 & video... where ca I find one of the clear end pieces you have the SOS switch monitoring. and/or a piece of clear pvc pipe to insert into my straight3/4" pvc drain pipe ?
@KavinSBS
@KavinSBS 3 жыл бұрын
You are the man
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks so much!
@joemc111
@joemc111 Жыл бұрын
Nice class. My float is connected to the yellow. I am going to add an LED across the float so I know that it’s open. I think I am going to break the RED any comments about this?
@PBS-nm1uu
@PBS-nm1uu 3 жыл бұрын
another great video. thanks, still would like more trouble shooting videos.
@robindenbeste5472
@robindenbeste5472 3 жыл бұрын
Thank you.
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
You're welcome!
@tphvac87
@tphvac87 2 жыл бұрын
Very informative Craig, how bout doing a few mini split safety switches? I typically break R is there any benefits to breaking Y I figured by breaking R customer would know right away that nothing is working.
@MF-tm4qu
@MF-tm4qu Жыл бұрын
You left out the Rectorseal SS500EP Can you please make a video on how to wire a secondary drain pan Rectorseal SS500EP and also how to wire it with a primary drain SS1 FLOAT Switch in series with a Rectorseal SS500EP. WE Use them alot in West Texas. A training video would help for beginners.
@ryanf.7933
@ryanf.7933 Жыл бұрын
Thanks!
@professorhvac
@professorhvac 3 жыл бұрын
Great explanation! Space MC.)
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Glad you liked it!
@MegaIsok
@MegaIsok 3 жыл бұрын
Just had a commercial unit flood the room beneath (over the weekend) it and cave in the drop ceiling because the safety switch failed. The service company didn’t put treatment tablets in the condensation pan so scum and debris had trashed the safety switch.
@christophernogas5032
@christophernogas5032 3 жыл бұрын
I always keep a can of pan treat tablets in my service bag, this time of year I’ll keep 2 or 3 cans on my truck
@farshadfaridmehr7271
@farshadfaridmehr7271 2 жыл бұрын
AWESOME!
@Funboyy123
@Funboyy123 3 жыл бұрын
I am in Toronto, Ontario and I never see PVC used for condensate or traps being installed. It is always just plastic tubing on a barbed fitting running to a drain. It seems this is more of an American style of condensate? Also no hvac stores sell condensate trap in Toronto that I have seen. very confusing for me lol
@tychoa.1960
@tychoa.1960 2 жыл бұрын
You only need condensate traps where there is negative pressure. So if the evaporator is after the blower then you don't need a trap because the blower is pushing air out the drain.
@user-nv9np5hj5g
@user-nv9np5hj5g 10 ай бұрын
My Wet Switch tripped twice in two days, with no water in sight. The A/C also quit blowing cool air. The inside (and outside) fans both work but only blows regular air temp. Is it a coincidence that this happened the same time the Wet Switch tripped (first time in the six years we've been here)? (I changed the capacitor, but that didn't fix it.) Any suggestions? My main question is could a malfunctioning Wet Switch cause the air not to be cool? What if it wasn't wired correctly? Here's how its wired: green+black>blue (from transformer) / red>red (from transformer) / yellow>dark blue / white>capped off. (2015 Daiken system)
@fabiodarocha2842
@fabiodarocha2842 3 жыл бұрын
Craig. How do I add oil to a compressor? The system uses R22 refrigerant. I’m trying to see a video but so far none close to what I need to see. My compressor uses mineral oil. Any type of mineral oil will do it?
@hafeezdaikin2517
@hafeezdaikin2517 3 жыл бұрын
👍
@eastpark4864
@eastpark4864 Ай бұрын
I pulled the float out and let it hang outside. Every time the drain backed up, It was shutting down my air condition. Now if the drain gets plugged it drips on garage floor where I can see it. No more calls to HVAC tech and getting ripped off $$.
@beckerlegjames
@beckerlegjames 2 жыл бұрын
I had my float switch fail so the contractor would not pull in but the inside fan would run. How would I determine that in the future and how common is it for a float switch to fail?
@gepardhvacservice1882
@gepardhvacservice1882 Жыл бұрын
How to wire wet switch to the 90 procent furnace..?
@realestateservicessaleshea99
@realestateservicessaleshea99 3 жыл бұрын
🍺😐👍🏻
@christophernogas5032
@christophernogas5032 3 жыл бұрын
I hate the pucks, they’re way too sensitive
@nakiapringley5391
@nakiapringley5391 3 жыл бұрын
Great video
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Thanks for the visit
@stephwaylonwells3218
@stephwaylonwells3218 3 жыл бұрын
👍
Electrical Troubleshooting! Finding 8 Electrical Faults!
26:04
AC Service Tech LLC
Рет қаралды 190 М.
Air Conditioner Troubleshooting! Connecting, Measuring, Fixing, Disconnecting!
21:05
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 37 МЛН
A teacher captured the cutest moment at the nursery #shorts
00:33
Fabiosa Stories
Рет қаралды 63 МЛН
My Cheetos🍕PIZZA #cooking #shorts
00:43
BANKII
Рет қаралды 25 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 35 МЛН
Avoid HVAC Related WATER DAMAGE (wiring safety switches)
11:33
Jersey Mike HVAC
Рет қаралды 6 М.
Checking the R-410A Refrigerant Charge! What to Watch Out For!
42:39
AC Service Tech LLC
Рет қаралды 54 М.
Condensate Pump Installation - Don't Miss this CRITICAL Step!
4:36
How To Install Water Safety Switches
28:39
Alex Z
Рет қаралды 2,7 М.
How to Properly Pipe a Drain on a Fan Coil
6:50
HVAC School
Рет қаралды 253 М.
40 VACUUM PROCEDURE TIPS for HVAC Techs! Avoid Frustration and Save Time!
27:12
FINALLY installing HVAC in my SHOP!!
32:28
Quality HVACR
Рет қаралды 26 М.
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 37 МЛН