I went to two trade two years ago for commercial refrigeration & HVAC and worked a year of residential now I’m in cascade refrigeration and industrial hvac so your videos have been helping out!
@HVACKnowItAll2 жыл бұрын
I'm glad to help!
@joeramirez25234 жыл бұрын
In light commercial, and beginning to get in to bigger systems and more complex stuff. This and all the other content you upload really helps love the channel!
@HVACKnowItAll4 жыл бұрын
Thanks Joe!
@CreativeMaintenanceSolutions Жыл бұрын
ohhhhhh to keep the evaporator from icing up is one really good reason ;)
@CreativeMaintenanceSolutions Жыл бұрын
But the question is why? This video was perfect in explaining what is happening, but WHY? What the purpose of introducing a false load to the evaporator? Thanks ahead of time.
@l.crossjr5 ай бұрын
Found one leaking through regardless off the adjustment position. Any tips before condemning?
@randydemontigny741 Жыл бұрын
Loki smoke a sporlan valve. Is there a specific like size you would use I am looking for one for a 410-a 5ton system.
@siriusscepter Жыл бұрын
Question please, If the valve goes bad. Is it possible the compressor would overamp and possibly give symptoms of a lock rotor?
@HVACKnowItAll Жыл бұрын
Not likely no
@Bdpjev5 жыл бұрын
You never explained why does the evaporator coul need a false load on it. Can you explain
@HVACKnowItAll5 жыл бұрын
Low load conditions
@scottm35523 жыл бұрын
Do you adjust the valve under a low load?
@HVACKnowItAll3 жыл бұрын
Correct!
@shuaib89082 жыл бұрын
Wouldn’t using a EPR valve be better?
@HVACKnowItAll2 жыл бұрын
EPRs maintain a set pressure, hot gas bypass valves prevent the pressure from dripping lower than wanted only in low conditions, not at all times.
@CMono104 жыл бұрын
Why not just have a regulator on the suction line since this is an energy penalty?
@airmechanical71636 жыл бұрын
Good explanation.
@HVACKnowItAll6 жыл бұрын
Thank you!
@seanmcdermott4165 жыл бұрын
What brand of valve was that ?
@HVACKnowItAll5 жыл бұрын
Sporlan
@randydemontigny741 Жыл бұрын
@@HVACKnowItAllis there a specific size you you used? I’m looking for one for a 410-a 5 ton system
@zoidelux5 жыл бұрын
Is this the same as an EPR?
@HVACKnowItAll5 жыл бұрын
no, an epr piped into the suction only, it does not utilize hot gas to create a false load
@sunilvarmaleo6 жыл бұрын
well said ...thank you..
@HVACKnowItAll6 жыл бұрын
My pleasure!
@paradieshenne4 жыл бұрын
Hi, does it staticly bypass some coolant or does it dynamicly change?
@charlesb74184 жыл бұрын
Discharge gas from the compressor is diverted from or bypasses the condenser and goes straight to the evaporator
@paradieshenne4 жыл бұрын
@@charlesb7418 and how is it controlled? Do you set a constant threshold or is it regulated by temperature/pressure?
@charlesb74184 жыл бұрын
@@paradieshenne watch the video again, he explains exactly how it works