HVAC Pressure Testing a Refrigerant Line with Nitrogen!

  Рет қаралды 140,043

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

Пікірлер: 100
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is a link the Nitrogen Regulator amzn.to/2bXdR5f Here is a link to the Nitrogen Flow Meter amzn.to/2brvoBg Here is a link to the Air Acetylene Torch setup- amzn.to/2aQalsb Here is the Link for the Yellow Jacket Refrigerant Manifold Gauge Set used in the videos- amzn.to/2aenwTq Here is a link to Refrigerant hoses with valves used in the videos- amzn.to/2aBumVI Here is a link to the Digital Refrigerant Scale used in the videos- amzn.to/2b9oXYl ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
@daviddelamaterii5801
@daviddelamaterii5801 Жыл бұрын
Video description was very understandable and informative
@kevinblankenship2433
@kevinblankenship2433 11 ай бұрын
The yellow hose has a ball valve on it, right off the regulator. You can have both the red and blue manifold valves open, and throttle it at the ball valve on the yellow hose. Also, you could bring it up slowly by the screw on the nitrogen regulator. This helps, if you have digital gauges that are very sensitive.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 3 жыл бұрын
Glad to see you doing this at a meaningful pressure, I see many barely pressurizing @ well below realistic values, sloppy work.
@Honestandtruth007
@Honestandtruth007 8 ай бұрын
As Always Thank you Teacher Craig 🙏👍
@guillermotejeda692
@guillermotejeda692 2 жыл бұрын
My gauges having been equalizing the high side seems to be about 20 psi more each timeI pressurize, any idea why?
@Louisyongcool2328
@Louisyongcool2328 4 жыл бұрын
One question can i use dye and nitrogen together to test the unit?
@cameronstrong100
@cameronstrong100 2 жыл бұрын
I'm sorry, did you say both of the Schraders we're out while nitro pressure testing?
@Brittvanegas
@Brittvanegas 9 күн бұрын
Yes
@officialmultie
@officialmultie 3 жыл бұрын
Good stuff man
@marcolopez9476
@marcolopez9476 6 ай бұрын
Where can I buy and recharge nitrogen cylinder in Texas?
@ekie85
@ekie85 Жыл бұрын
Are you using dry nitrogen or nitrogen?
@dcrickerson7611
@dcrickerson7611 7 жыл бұрын
Another great video! Thank for all your time and effort in making these video's.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks a lot DC!
@monikarealtor2876
@monikarealtor2876 Жыл бұрын
Good morning My ac refrugrent line exploded under the house is it possible to perform nitrogen pressure test on already broken pipe. Please let me know
@APEXIII
@APEXIII 3 ай бұрын
The point of a pressure test is to see if you have leaks in the system. If you’re pipes have burst there is no point in doing the test
@abbe6305
@abbe6305 11 ай бұрын
when i braze in a new compressor, scroll copeland, i need to have nitrogen, its it correct that i put nitro on low side and blow out on the high side? Becuse the compressor have a rewerse seal on high side in compressor and can damage the seal?. correct? so its ok to flow nitrogen in to the compressor while braze?
@raindogs451
@raindogs451 Жыл бұрын
My only objection to brazing is that Stay Bright is almost always a superior connection; shear strength, tensile strength and bursting strength. Only in melting point (med gas) and sloppy connections is brazing worth a darn. Maybe dissimilar metals too. HVAC orthodoxy says "flux is evil" in spite of the fact it is used in some brazing too. Soldering is just a better connection in most applications.
@MdRizwan-by4hp
@MdRizwan-by4hp 4 жыл бұрын
Thank you sir 🙏
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
So nice of you
@paulkurilecz4209
@paulkurilecz4209 3 жыл бұрын
Is ten minutes at the test pressure with no pressure drop considered sufficient that only extremely small leaks exist? Is this best way to find very, very small leaks to put about 10 psig of refrigerant into the line set and evaporator and then pressure up with N2 to the test pressure? TIA
@angelzucchet8543
@angelzucchet8543 Жыл бұрын
Excelent thank you 😄
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Happy to help!
@Twoface0233
@Twoface0233 4 жыл бұрын
Why do you have to take the schrader cores out before brazing? And what exactly happens to the service valves if you don’t protect them?
@marconantel7735
@marconantel7735 4 жыл бұрын
They are pretty easily damaged from heat, orings and seals
@calledout4437
@calledout4437 Жыл бұрын
Hey thanks for the video. I'm getting ready to replace my compressor. What if I don't have nitrogen? Is there some other effective way to test? Or if I'm confident in my joints while I know it's not recommended, can I just skip the pressure test?
@kinetic1259
@kinetic1259 Жыл бұрын
I noticed in the installation guides for some new models don't require a nitrogen pressure test anymore (at least for warranty), only confirming that the piping and units hold a vacuum of -76 cmHg (­-0.1 MPa) for 15 minutes before releasing refrigerant into the system. Still a good idea... But not technically required for warranty.
@fastlife866
@fastlife866 7 жыл бұрын
i have a technical question.. I was on a job today. r22 two ton unit with txv. evap is clean, filters clean, good airflow, condenser is clean good airflow. my question is I have 1 degree subcooling and high superheat. aprox 80 psig lowside and 201 psig high side. suction line temperature was 75F. i have 14 degree split across both indoor unit and outdoor unit. pressures are steady no fluctuations. unit is 2006. acording to my chart it says to add refrigerant but my suction saturated temp is 50 degrees. my guess is a bad txv what do you think my issue is?
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Hey Brian, was it extremely hot and humid in the house possibly and there is that much heat in the refrigerant. What was the dry bulb outside?
@fastlife866
@fastlife866 7 жыл бұрын
acservicetech house was 79 inside, my outdoor dry was 84
@yonkromis7883
@yonkromis7883 6 жыл бұрын
@@fastlife866 tell me what the chart says or let the house cool down to the right temperature and test ir again
@fastlife866
@fastlife866 6 жыл бұрын
@@yonkromis7883 if i remember correctly i added refrigerant to bring the superheat down. Even though my pressures were higher then average the superheat n subcooling i got dialed in and it was working fine.
@yonkromis7883
@yonkromis7883 6 жыл бұрын
@@fastlife866 thank you for your timely response I figured that was the thing that you did
@geometric2194
@geometric2194 Жыл бұрын
Do you keep your Schrader valves out still when pressure testing?
@jayweiner977
@jayweiner977 Жыл бұрын
You can. If you have a shrader removal tool it’s best to use that. Also makes your vacuum faster.
@zekenzy6486
@zekenzy6486 7 жыл бұрын
great video. thanks you
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks ZE!
@80SWoods
@80SWoods Жыл бұрын
Do you have to use nitrogen to pressure test? I’m installing my own system and was hoping to use welding gas (argon/O2) since that’s what I have on hand. I “assume” the vacuum pump will pull anything all out anyhow when I do that step.
@A-bone
@A-bone Жыл бұрын
Don’t use argon
@DaleKlein
@DaleKlein Жыл бұрын
@@A-bone Why not? (beside the probably extra cost of CO2/Argon mix vs. N2)
@joes4407
@joes4407 5 жыл бұрын
If manual for Lg heat pump says to pressure test to 550psig but condenser has 450psig operating pressure labeled on unit, what would you recommend? Thank again.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
If you have a digital manifold you can pressure test to 450 and see any drop very quickly compared to a compound gauge. If it is an older unit then only pressure test to 200 or maybe 300psi. You don't want to cause a leak, thanks!
@khybersafi9137
@khybersafi9137 4 жыл бұрын
How do you flow nitrogen from one side to the other if the coil has a non-bleed TXV? Thanks.
@exclusive_148
@exclusive_148 3 жыл бұрын
Let nitro in through both sides. Then let it out
@jimbola77
@jimbola77 7 жыл бұрын
excellent video thank you for sharing!!!!!!
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks jimbola77!
@dougharsch9995
@dougharsch9995 6 жыл бұрын
What size nitrogen bottle and how much nitrogen is needed on a typical job for soldering lines and then pressure testing?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
We use a 60cf or 40cf tank. I carry 60cf tanks in the truck and I use maybe a 1/4 of a tank each install, thanks and I have the nitrogen regulators and nitrogen flow regs that I use linked at amazon.com/shop/acservicetech
@dougharsch9995
@dougharsch9995 6 жыл бұрын
@@acservicetechchannel Thanks
@baleDELgavilan713
@baleDELgavilan713 6 жыл бұрын
Didnyou recover the refrigerant into the compresor or into a vacuum?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Initially, when taking out the old unit, the compressor internal pressure relief blew when doing the pump down as it was very weak. I just shut the valves and recovered the rest. I wanted to reuse this unit ans a testing unit at my shop. Usually you will just recover everything out and not pump down unless you are reusing a unit, thanks.
@daryllneuburger4946
@daryllneuburger4946 7 жыл бұрын
I have recently been taught to slowly add thru the high side then slowly thru the low side I was told by adding to fast can cause the TXv to slam shut I personally have not had this happen but wondering your thoughts I have been replacing a few TXv s lately due to the installers adding the nitrogen to fast or that's what are senior tech says
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
That could possibly happen. It could also be the tech brazing the suction line for a long time without removing the bulb or an install brazed without nitrogen and the byproduct mixing with anti corrosives put in by the manufacturer. You should always add nitrogen into both the high and low sides at the same time. You can add it fairly quickly that way with no problem. When you say adding refrigerant into the liquid side, I am assuming that you are talking about breaking a vacuum with liquid refrigerant after doing something like a compressor changeout or weighing in refrigerant by weight per foot. Yes slowly add through the low side while on and best to use a kwik charge vaporizer to keep the compressor safe, thanks!
@daryllneuburger4946
@daryllneuburger4946 7 жыл бұрын
thanks for your responce the way you do it was the way i was taught but i try to never stop learning the way i was taught is not always the best lol
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks Daryll!
@FloridaMan7337
@FloridaMan7337 6 жыл бұрын
Can you use Dawn dish soap as the bubble leak detector?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
We try to stay away from all dish soaps now, including Dawn. Just use non corrosive bubble leak detector. It is cheap, works well, and won't corrode the pipe, thanks- If you are looking for the right kind, I have the Rectorseal version I use linked at amazon.com/shop/acservicetech thanks
@FloridaMan7337
@FloridaMan7337 6 жыл бұрын
What if I rinsed it off good with a neutralizer like water and vinegar? Also, does that Rectorseal work as a leak detector and braze work sealant?
@geoffrey5239
@geoffrey5239 3 жыл бұрын
Nice video and just what I was looking for in installing a split unit system. I note that you did not close off the nitrogen supply until the end. Would it not be better to shut off the nitrogen supply while you are waiting to see if the pressure drops in the system ?
@acservicetechchannel
@acservicetechchannel 3 жыл бұрын
Yes I could have, however, I had those handles shut and the pressure in the regulator was not much more but yes, I could have taken the pressure off at the tank reg, thanks!
@geoffrey5239
@geoffrey5239 3 жыл бұрын
I withdraw my comment - I did not appreciate that you had closed the manifold's connection to the Nitrogen cylinder while waiting to see if the pressure held !
@poryeyang1854
@poryeyang1854 7 жыл бұрын
i was wondering if you can do a review on the best leak detectors and which one picks up better..etc..and which one you prefer most.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thank you for letting me know what you would like to see!
@ddcws1
@ddcws1 5 жыл бұрын
If you find a system almost completely out of refrigerant then recover the remaining refrigerant, pressure test with nitrogen and find no leaks. Should you put system under vacuum?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Hey David, yes pressure test with a digital gauge set for more precise measurements over a shorter span. If it doesn't drop after 10 minutes then there is not a leak. Remember nitrogen will still fluctuate due to temperature but very little compared to air. It could have leaked through the valve cores or there is the possibility of someone releasing it on purpose. After you get done the job, make sure to put locking caps on the ports. This way you know people are not able to get into the system without the key. The standing vacuum test will also verify no leaks, thanks a lot David and Great to hear from you!
@MrSpartan117fan
@MrSpartan117fan 5 жыл бұрын
I build refrigeration units and the company asks for a 250 psi test for 20 minutes and nomatter what the guages will stay put for a few minutes then start dropping . I check every joint with soap and nothing . The system then holds vacuum no problem . Dont understand whats happening you have any insite?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
It is possible that the setup used for pressure testing is leaking or the bottle is hotter than the system which causes the pressure to lower.
@MrSpartan117fan
@MrSpartan117fan 5 жыл бұрын
@@acservicetechchannel I have tested my guages with soap and submerged the hoses in water and there are no leaks . If the nitogen is cool the pressure will drop when its in the system? I use a large nitrogen bottle that is around 5 feet tall in a space where the ambient temperature is around 24-25 C . Could what you said about the nitrogen be my problem?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Certainly, especially if its holding vacuum during a ten minute standing vacuum test and this same thing happens every time, thanks
@MrSpartan117fan
@MrSpartan117fan 5 жыл бұрын
@@acservicetechchannel Thank you very much for confirming with me !
@ashyurivillanueva6095
@ashyurivillanueva6095 4 жыл бұрын
SIR, GOOD DAY! WHY THE PRESSURE OF MY SUNCTION LINE IS 55PSI THEN ALL OF A SUDDEN ITS DROP IN 30PSI? BUT MY AMPERE READING IS STILL 14.4AMPS? PLEASE HELP! THANK YOU! 🙂
@ashyurivillanueva6095
@ashyurivillanueva6095 4 жыл бұрын
LG MODEL: TP-C808FLA1. 72,000 BTU. R22. 3PHASE. NORMAL AMPERE 14.0A MAX 18.5A
@JacobandAlaina
@JacobandAlaina 5 жыл бұрын
What size nitrogen tank did you use?
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
60 cubic foot tank thanks
@sergiodoordie319
@sergiodoordie319 6 жыл бұрын
Hey great video man so u did all this work without the valves on the service ports right ?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thats correct, I put the valve cores back in after breaking the vacuum with the refrigerant, thanks
@tommyteamer9037
@tommyteamer9037 Жыл бұрын
Amazing video on showing how to do a pressure test.
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 7 жыл бұрын
Great video thank you.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks Ron!
@wildman8601
@wildman8601 6 жыл бұрын
If the condenser has a filter already installed is it still smart to add another filter dryer in the attic ??
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Just use the one to avoid any excessive pressure drops, thanks
@wildman8601
@wildman8601 6 жыл бұрын
acservicetech ok figured but wanted to ask because you're really on point w your knowledge
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Glad to help Wild Man!
@Pretzel114
@Pretzel114 7 жыл бұрын
Thanks for the video Acservicetech. For R22 if no safe psig is given you only go to 150psig then what is a limit for r410 if there is no max psig listing on the unit? Thanks again.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Most R410A Evap coils are newer and usually have a max design pressure uless they were retrofitted from r-22 to r410a with a piston or txv change.If that is the case then I still wouldn't go much higher than 150, maybe 200 at the max. If the coil is newer within the last ten years or so and cooling only then maybe test up to 250-300, thanks Nick!
@Pretzel114
@Pretzel114 7 жыл бұрын
acservicetech Thanks for the reply acservicetech. Helps expand my knowledge a little more lol. take care
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Glad to help Nick!
@ergarzavala2330
@ergarzavala2330 6 жыл бұрын
Can you leave the gauges open when pressure testing
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
I wouldn't. I want as much control as possible that take out of play a possible leak in the nitrogen regulator or gauge set. Remember that when the handles are shut then the pressure is just going straight to the gauges but if the handles are open then it connects to the service hose and regulator, thanks
@ergarzavala2330
@ergarzavala2330 6 жыл бұрын
Thanks for the explanation
@طارقالمخبرالتقني
@طارقالمخبرالتقني 3 жыл бұрын
لماذا لاتخبرهو الخصائص الغاز الخطيرة السام ...والقابل للشتعال .....
@MrMagsimus
@MrMagsimus 9 ай бұрын
Thanks nice video
@julianomartinez6080
@julianomartinez6080 Жыл бұрын
Question for anyone: as you can see, the technician in the vid is using the refrigerant gas gauges for the process of injecting Nitrogen to 50 PSI first, and then up to 300 PSI into the system. However those are not Nitrogen gauges. They're rather gauges for the specific refrigerant gas of that air conditioner. The only valid Nitrogen gauges are the ones connected to the Nitrogen bottle. So when he's reading "50 or 300 PSI of Nitrogen" at the refrigerant gauges, he may not have that pressure at all. The question is: what's the actual pressure he should read at the refrigerant gauges for 50 and 300 PSI of Nitrogen, respectively, and why?
@kinetic1259
@kinetic1259 Жыл бұрын
As long as you purge your gauges and hoses with.... Wait for it... Nitrogen 😂 Beforehand, you're good to go, what you're talking about is mixing different refrigerants. Also, some refrigerants operate under different pressure ranges.
@whitewigglesworth
@whitewigglesworth 5 ай бұрын
50 psi is 50psi dude. Its literally the gas pressing on the walls of the container at a pressure of fifty pounds per sqaure inch. It doesnt matter what the gauges were meant to be used with. By the way the gauges are designed to work with nitrogen and alot of different refrigerants.
@throttlebottle5906
@throttlebottle5906 7 жыл бұрын
you could have gotten away with saying "pounds" vs psig.
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
I am a teacher, what can I say, ha ha, thanks!
@goru426
@goru426 5 жыл бұрын
Is it not dangerous for a person to release so much Nitrogen so close to himself? After all Nitrogen can displace oxygen from your lungs.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Nitrogen is roughly 80% of the air and this was outside so it was fine but it also very controlled as well. You want to make sure to not shoot the rubber grommet from the end as well, thanks!
Air Conditioner Troubleshooting! Connecting, Measuring, Fixing, Disconnecting!
21:05
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
REAL or FAKE? #beatbox #tiktok
01:03
BeatboxJCOP
Рет қаралды 18 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
How We Transformed This Loft with Amazing Cabrio Windows! (Before & After)
17:27
Build it with Rob loft conversion specialist
Рет қаралды 4,4 М.
HVAC 153 Nitrogen Pressure test with Analogue gauges
13:32
Love2HVAC with Ty Branaman
Рет қаралды 50 М.
How to Check AC Freon Level
16:41
Word of Advice TV
Рет қаралды 2,1 МЛН
Vacuuming, Weighing Refrigerant, Checking the Charge of an HVAC Unit!
20:53
AC Service Tech LLC
Рет қаралды 152 М.
HVAC Nitrogen Regulator Operation
6:18
Palomar College; ACR Technology
Рет қаралды 64 М.
HOW TO LEAK TEST AN AC SYSTEM WITH NITROGEN PRESSURE
6:38
Alex The Handyman
Рет қаралды 12 М.
How to Leak Test an AC With Nitrogen Pressure
8:00
HVAC School
Рет қаралды 245 М.
Mini-Split Heat Pump: Nitrogen Pressure Test
11:27
stuzman
Рет қаралды 200 М.
How to Line Isolation Test an AC System
9:45
HVAC School
Рет қаралды 40 М.
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН