Very very nice . People who share knowledge are the real teachers and we'll wishers
@zebralearnings3 ай бұрын
Thank you so much for your words
@solankibharat89637 ай бұрын
Good knowledge
@zebralearnings7 ай бұрын
Thanks
@juglalchaudhary261513 күн бұрын
nice video thanks sir
@ravindraperera20907 ай бұрын
Clear and easily understandable
@zebralearnings6 ай бұрын
Thank you
@meassavuth464918 күн бұрын
Thanks for your video ❤
@tahernabieh609622 күн бұрын
Nice
@MrRene1968Ай бұрын
Well explained, thank you.
@Helawedakama2 ай бұрын
Best❤ video
@zebralearnings2 ай бұрын
Thank you
@ChandanaPriyantha-pq3uv6 ай бұрын
It is a easy way to learn
@zebralearnings6 ай бұрын
Thank you 😊
@jonelverine47804 ай бұрын
Zebra Learning is being the best way to understand the HVAC. 1:37
@zebralearnings3 ай бұрын
Thank you so much
@srinivas93916 ай бұрын
Use full video 👍
@zebralearnings6 ай бұрын
Thank you 😊
@TanDreamMOVIES-uo1lf3 ай бұрын
Please 🙏 make a video on the brazing technique. I love you videos.
@zebralearnings3 ай бұрын
Coming soon!
@elnursafaraliyev66186 ай бұрын
Hi. How is a nitrogen leak test where installed electronic thermal valve is installed?
@alimandoser75015 ай бұрын
Make animation on how to lock refrigerant in AC outdoor unit for service
@rodolfofrancisco3 ай бұрын
What if the leak is in tubes inside walls where you don't have access to spray bubbles?
@gangalichakradhar17425 ай бұрын
When the expansion valve closed at the evaporator how nitrogen is weynt from suction line to discharge line.
@DurgaprasadRayudu-b8k6 ай бұрын
How to compressor side nitrogen gas going inside after any problem?
@whoIsV6 ай бұрын
My neightbor did the leak test and the servicemen used R32 gas to check as it was readily available to them. They filled it and kept it for 15 mins under pressure of 250 I think after that pressure didn't reduce so there is no leak according to him. Is that legit?
@mohammedshoaib87443 ай бұрын
Not at all
@jakubjakubowski94417 күн бұрын
Using R32 for leak detection kind of defeats the point, doesn't it? If there was a leak then we are leaking refrigerant.. But other than that sounds like valid confirmation for no leaks.
@techtalentofficial016 ай бұрын
👍
@CheeKengChua3 ай бұрын
If the nitrogen test was set at 300 psi and drop to 270 psi after two days, can it be considered leak?
@thisisyourcaptainspeaking22592 ай бұрын
That's very good. 10psi/hour is maximum allowable (this is not very good, IMO).
@CheeKengChua2 ай бұрын
@@thisisyourcaptainspeaking2259 sorry, so may I know 2 days drop 30psi is it consider leak? Or it is normal to drop a bit after 2 days?
@BUTLERENGLISH7 ай бұрын
Agr ye video kuch din phle aata to mai interview me pass ho jata😢😢😢 Muje pucha kii nitrogen hii kyu use krte hai, koi dusra gas kyu nhi use krte hai leak test ke liye or mai kuch bol nhi paya
@zebralearnings7 ай бұрын
☹️ Don't worry. In the next interview you will get selected.
@zebralearnings7 ай бұрын
I made this video for you.
@BUTLERENGLISH7 ай бұрын
@@zebralearnings Thank you so much Sir
@BUTLERENGLISH7 ай бұрын
@@zebralearnings I hope so.
@savailalp58107 ай бұрын
❤❤
@vigneshkumar986 ай бұрын
Kindly reply to the below comment pls.... Its important question....👇