Nitrogen Leak Test | How to do? | Animation |

  Рет қаралды 23,268

Zebra Learnings

Zebra Learnings

Күн бұрын

Пікірлер: 41
@vysakhcs1957
@vysakhcs1957 4 ай бұрын
Very very nice . People who share knowledge are the real teachers and we'll wishers
@zebralearnings
@zebralearnings 3 ай бұрын
Thank you so much for your words
@solankibharat8963
@solankibharat8963 7 ай бұрын
Good knowledge
@zebralearnings
@zebralearnings 7 ай бұрын
Thanks
@juglalchaudhary2615
@juglalchaudhary2615 13 күн бұрын
nice video thanks sir
@ravindraperera2090
@ravindraperera2090 7 ай бұрын
Clear and easily understandable
@zebralearnings
@zebralearnings 6 ай бұрын
Thank you
@meassavuth4649
@meassavuth4649 18 күн бұрын
Thanks for your video ❤
@tahernabieh6096
@tahernabieh6096 22 күн бұрын
Nice
@MrRene1968
@MrRene1968 Ай бұрын
Well explained, thank you.
@Helawedakama
@Helawedakama 2 ай бұрын
Best❤ video
@zebralearnings
@zebralearnings 2 ай бұрын
Thank you
@ChandanaPriyantha-pq3uv
@ChandanaPriyantha-pq3uv 6 ай бұрын
It is a easy way to learn
@zebralearnings
@zebralearnings 6 ай бұрын
Thank you 😊
@jonelverine4780
@jonelverine4780 4 ай бұрын
Zebra Learning is being the best way to understand the HVAC. 1:37
@zebralearnings
@zebralearnings 3 ай бұрын
Thank you so much
@srinivas9391
@srinivas9391 6 ай бұрын
Use full video 👍
@zebralearnings
@zebralearnings 6 ай бұрын
Thank you 😊
@TanDreamMOVIES-uo1lf
@TanDreamMOVIES-uo1lf 3 ай бұрын
Please 🙏 make a video on the brazing technique. I love you videos.
@zebralearnings
@zebralearnings 3 ай бұрын
Coming soon!
@elnursafaraliyev6618
@elnursafaraliyev6618 6 ай бұрын
Hi. How is a nitrogen leak test where installed electronic thermal valve is installed?
@alimandoser7501
@alimandoser7501 5 ай бұрын
Make animation on how to lock refrigerant in AC outdoor unit for service
@rodolfofrancisco
@rodolfofrancisco 3 ай бұрын
What if the leak is in tubes inside walls where you don't have access to spray bubbles?
@gangalichakradhar1742
@gangalichakradhar1742 5 ай бұрын
When the expansion valve closed at the evaporator how nitrogen is weynt from suction line to discharge line.
@DurgaprasadRayudu-b8k
@DurgaprasadRayudu-b8k 6 ай бұрын
How to compressor side nitrogen gas going inside after any problem?
@whoIsV
@whoIsV 6 ай бұрын
My neightbor did the leak test and the servicemen used R32 gas to check as it was readily available to them. They filled it and kept it for 15 mins under pressure of 250 I think after that pressure didn't reduce so there is no leak according to him. Is that legit?
@mohammedshoaib8744
@mohammedshoaib8744 3 ай бұрын
Not at all
@jakubjakubowski944
@jakubjakubowski944 17 күн бұрын
Using R32 for leak detection kind of defeats the point, doesn't it? If there was a leak then we are leaking refrigerant.. But other than that sounds like valid confirmation for no leaks.
@techtalentofficial01
@techtalentofficial01 6 ай бұрын
👍
@CheeKengChua
@CheeKengChua 3 ай бұрын
If the nitrogen test was set at 300 psi and drop to 270 psi after two days, can it be considered leak?
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 ай бұрын
That's very good. 10psi/hour is maximum allowable (this is not very good, IMO).
@CheeKengChua
@CheeKengChua 2 ай бұрын
@@thisisyourcaptainspeaking2259 sorry, so may I know 2 days drop 30psi is it consider leak? Or it is normal to drop a bit after 2 days?
@BUTLERENGLISH
@BUTLERENGLISH 7 ай бұрын
Agr ye video kuch din phle aata to mai interview me pass ho jata😢😢😢 Muje pucha kii nitrogen hii kyu use krte hai, koi dusra gas kyu nhi use krte hai leak test ke liye or mai kuch bol nhi paya
@zebralearnings
@zebralearnings 7 ай бұрын
☹️ Don't worry. In the next interview you will get selected.
@zebralearnings
@zebralearnings 7 ай бұрын
I made this video for you.
@BUTLERENGLISH
@BUTLERENGLISH 7 ай бұрын
@@zebralearnings Thank you so much Sir
@BUTLERENGLISH
@BUTLERENGLISH 7 ай бұрын
@@zebralearnings I hope so.
@savailalp5810
@savailalp5810 7 ай бұрын
❤❤
@vigneshkumar98
@vigneshkumar98 6 ай бұрын
Kindly reply to the below comment pls.... Its important question....👇
@zebralearnings
@zebralearnings 6 ай бұрын
Hi
@vigneshkumar98
@vigneshkumar98 6 ай бұрын
@@zebralearnings Hi there
Humidity Explained | Animation | #HVAC
6:07
Zebra Learnings
Рет қаралды 54 М.
How to Leak Test an AC With Nitrogen Pressure
8:00
HVAC School
Рет қаралды 244 М.
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
HVAC 153 Nitrogen Pressure test with Analogue gauges
13:32
Love2HVAC with Ty Branaman
Рет қаралды 50 М.
How to Find AC Leaks in Your Car (UV Dye)
13:30
ChrisFix
Рет қаралды 4,9 МЛН
HOW TO LEAK TEST AN AC SYSTEM WITH NITROGEN PRESSURE
6:38
Alex The Handyman
Рет қаралды 11 М.
A/C Leak Testing That Will Guarantee You Find It!
9:35
Royalty Auto Service
Рет қаралды 34 М.
HVAC Nitrogen Regulator Operation
6:18
Palomar College; ACR Technology
Рет қаралды 63 М.
How to Make a Powerful Mini Freezer - Portable Mini Air Conditioner up to -10ºC
10:07
The Liberty Engine Project
Рет қаралды 3,4 МЛН
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 159 М.
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН