Quick tip when doing all-thread, put a nut on both sides of the cut and then back the nut off of the cut ends. It will re-thread buggered ends every time.
@hkhsm3594 жыл бұрын
Nice job. Quality installation. Keep posting, I will be happy to see outside part installation.
@ductlessplushvac2 жыл бұрын
Dude check out our installs
@billionpod2 жыл бұрын
What about installing a Mitsubishi EZ-cassette in a finished room? I'd love to see THAT video.
@serolog Жыл бұрын
This was, actually, amazing
@RJMaker4 жыл бұрын
Well Done Britton and Jordan! Thanks for the video.
@MyBallzGotShocked9 ай бұрын
Nicely surprised at just how nice everything nicely turned out really nice.
@come_on_now2 жыл бұрын
The navac is awesome. Nylog is also AWESOME! For future, when a service tech needs to replace the flare, make the copper longer AND write torque specs... at indoor AND outdoor units. ALSO, at outdoor unit, write line sets length!! At the outdoor unit, write with a UV pen of SOME SORT! Not a sharpie! Needs to withstand UV
@786otto3 жыл бұрын
Looks great except those home depot hooks, Grainger has professional attachments for threaded rod.
@trfisher784 жыл бұрын
Actually, I actually learned something here actually...
@josephhathorn15642 жыл бұрын
Actually dude
@SB-vi9kg27 күн бұрын
Very informative...Thank you..
@ishaqmd.90265 ай бұрын
Very easy to follow video.
@robfleming62873 жыл бұрын
Put the nut on the all-thread first. Then when you remove the nut, it will clean up the cut threads.
@Aryan-bn3fl3 жыл бұрын
Good Installation
@JA-vy1gp11 күн бұрын
Great video
@inhocsigno91513 жыл бұрын
Loctite for the nuts and threaded rod, or double nut them? Seems they might come loose with vibration over time.
@raygamero2413 жыл бұрын
Thank you you are very helpful can you please do more HVAC videos of charging units Mini Splits Etc you're a smart guy thanks
@kamenpetrov6614 жыл бұрын
Nicely done very professional just one safety glasses
@ChrisHVAC4 жыл бұрын
Nice job! I wish our building code was as easy as yours is. We can't use tray cable outside so we use plastic coated MC We also have to strap up the cable, drain and lineset Then again you guys have all that hurricane code we don't have to deal with here
@cengeb4 жыл бұрын
It's not tray cable, it's outdoor rated sun resistant , when ya buy the real stuff for minisplit interconnections.
@raygamero2413 жыл бұрын
You're a smart guy thanks for the video can you make a video about charging mini split units multi-zone ones thanks
@jivancich Жыл бұрын
Damn nice tools and set up❤
@tjinytjiny66154 жыл бұрын
Excellent video..
@HVACS4 жыл бұрын
Thank you very much!
@rajlovinglife4 жыл бұрын
Good job if only you would have shown the outdoor compressor/condenser unit .....with Installing the indoor unit plate for final touches..........
@ssrrocks22 Жыл бұрын
I would recommend you use the correct hight ladder. OSHA would handyou a nice 500 to a 1000 dollar fine! Just FYI
@KentuckyReef4 жыл бұрын
They make 90degree “sammies” for 3/8” all thread. It would look a little more professional. JMO
@reluctantprophet4 жыл бұрын
Chris Durham 👍🏽 yes those eye bolts aren’t designed for lateral forces, I also would have added some wood cross bracing to keep my supports plumb
@CockyMike9113 жыл бұрын
When they blow in R30 on top of this set up.... who's gonna ever see it again? Find another reason to be critical of another man's work.... JMO
@CockyMike9113 жыл бұрын
This unit weighs a whopping 32 lbs... pretty sure it's gonna hold up just fine.
@KentuckyReef3 жыл бұрын
@@CockyMike911 ok speedy, was someone being critical or just letting someone know that the same company makes a different product that would be better suited for the application.. No that’s not a question.
@GreatMelancholy3 жыл бұрын
@@KentuckyReef Be more critical. Like the terminations should have spade crimps or at least be wrapped in the proper orientation.
@peterchaploutskiy25553 ай бұрын
Nicely done, acrually. Does anyone knows if drain hose has a check valve?
@ramytk14 жыл бұрын
Hey great video. Not sure if you’ve used these. There is a brand called Sammies. They make a screw that has a 3/8 threaded hole for the threaded rod. They are great to use in applications like that. They come in different styles. Again great video. It’s great to see people keeping care in the HVAC Industry. How do you like the Navac tool? Any cons to it?
@HVACS4 жыл бұрын
I will try to answer these in my Q/A video
@Kobe292613 жыл бұрын
Thank you!
@JDT7381262 жыл бұрын
the eye hooks are a great idea and far less than a L-bracket! What model cassette is that ? The videos say you need at least 16" to install so if that's only 12" wide that is a great option for the old homes in new england.
@JScott-wz2ug3 жыл бұрын
"Actually" a good video.
@jasonbeaver10613 жыл бұрын
Jesse from Breaking Bad gets a career in HVAC. Nice!
@yitzlebo123 жыл бұрын
Will this fit between 2x8 joists x 16” OC ? No TGI just regular wood joists ?
@paxlepham3 жыл бұрын
Nice work. And for 14 dislike, could please point out why you guy disliked?
@AA-zq1sx2 жыл бұрын
"This is not at all how this should be done and certainly not a “quality” installation as some have commented. Lines and drain should all be strapped secure. No cement on the drain connection at the unit!? Ever read the install manual? “Be sure to connect the drain hose connecting part using adhesive of polyvinyl chloride family to prevent leakage”. Wow. The thing is swinging free and wobbling back and forth it’s an insult to craftsmanship. The unit should be installed solid on rigid rod, if you can’t figure out how to do that you shouldn’t be installing. This poor customer. Not to mention who’s going to tell the dry wallers the exact dimension of the opening so they don’t drywall up to the edges of the unit. Then the grill won’t fit on and the drywall will have to be cut back. If it’s to be under insulation (especially blown cellulose) there should be plastic barrier covering unit to protect from dust (again, read install instructions if you’re new to this). It’s much better to install lines, drain and wiring in position, then cut the unit in after drywall is painted. Way cleaner and the customers unit isn’t exposed to all the construction dust. Units can easily be removed from below, they’re designed to be installed into finished ceiling. Yes this equipment lasts very well if it’s applied and installed correctly…which this unit is absolutely not. This is not at all how this should be done."
@andrewhallworth713222 күн бұрын
How would you access post completion for repair and maintenance
@cdubs17234 жыл бұрын
Nylog is for the mating flares, not the threads
@MikaelS19774 жыл бұрын
You are right but after hearing the podcast Bryan did with Refrigeration Technologies i have changed my mind. I use it on the flare, threads (for sealing) and betwean the nut and flare to reduce friction as to not galling. www.refrigtech.com/nylog-blue/
@danielg.95784 жыл бұрын
@@MikaelS1977 Never put anything on the flare or union face. It is a mechanical seal. Doesn't require any kind of sealant, you lubricate the threads to allow proper torque.
@MikaelS19774 жыл бұрын
@@danielg.9578 Yes in a perfect world :) if ther is any small voids it will help making a seal (yes a good flare dosent have any voids). Watch this AD and do as you wich :) kzbin.info/www/bejne/j5O8fpd8qLl8osk Greetings from Sweden
@patrickknowles58963 ай бұрын
Did the Mits ceiling cassette come pre-charged with nitrogen? It didn’t appear so as there was no release of pressurized gas…
@StanBenton3 жыл бұрын
Since the room was already gutted why didn’t you run the line set down the inside of the wall? Had that been my house I would have happily paid a little more for you to drill thru the concrete instead of having to look at that line running down the exterior of the house.
@ductlessplushvac2 жыл бұрын
Check out our installs “Ductless Plus HVAC”
@ductlessplushvac2 жыл бұрын
This dudes install is ugly as hell no zip ties on the wire and line-sets.
@jerryleblanc39992 жыл бұрын
Great videos. Hoping you can help. The condensate drain calls for a VP20 pipe with a 26 mm o.d. But 3/4” pvc is 26.7 mm o.d. Mitsubishi calls for using pvc cement. How do you make this connection?
@Michaelaharoni4 жыл бұрын
very well made video. I am planning on installing Mitsubishi 5 stations using a branch box. Are you available for consultation
@tonyabdalla3 жыл бұрын
I played the "actually" drinking came and I was trashed by minute 4...actually...
@antoniorangel46004 жыл бұрын
No isolators. Looks good
@hvacguy119 ай бұрын
Can you install these on an angled ceiling.
@jasongoertzen4 жыл бұрын
I hate to be this guy but how do you change this unit out or service it once it's hidden behind the sheetrock. Nice install though!
@capnclench37864 жыл бұрын
We are not allowed to install cassettes in anything other than dropped ceilings where I am. I was thinking the same thing
@joeshearer12474 жыл бұрын
I wonder this too
@paulgaras26064 жыл бұрын
The face plate leaves enough coverage for the drywall to be cut back enough for you to lower the unit for repairs if needed. You can use a “super socket” to take the nuts off. In commercial buildings with water source systems you have to drop units for repairs all the time. Truthfully, I’d rather pull a 30 lb cassette out of a drywall ceiling than a wshp out through a drop ceiling.
@leekazan5564 жыл бұрын
Well, I do HVAC in industrial spaces and if you buy a Fujitsu, it will probably last until you retire!
@AA-zq1sx2 жыл бұрын
Um... you can go into the attic to service or change it?
@tiernonator3 жыл бұрын
This is not at all how this should be done and certainly not a “quality” installation as some have commented. Lines and drain should all be strapped secure. No cement on the drain connection at the unit!? Ever read the install manual? “Be sure to connect the drain hose connecting part using adhesive of polyvinyl chloride family to prevent leakage”. Wow. The thing is swinging free and wobbling back and forth it’s an insult to craftsmanship. The unit should be installed solid on rigid rod, if you can’t figure out how to do that you shouldn’t be installing. This poor customer. Not to mention who’s going to tell the dry wallers the exact dimension of the opening so they don’t drywall up to the edges of the unit. Then the grill won’t fit on and the drywall will have to be cut back. If it’s to be under insulation (especially blown cellulose) there should be plastic barrier covering unit to protect from dust (again, read install instructions if you’re new to this). It’s much better to install lines, drain and wiring in position, then cut the unit in after drywall is painted. Way cleaner and the customers unit isn’t exposed to all the construction dust. Units can easily be removed from below, they’re designed to be installed into finished ceiling. Yes this equipment lasts very well if it’s applied and installed correctly…which this unit is absolutely not. This is not at all how this should be done.
@shenoyglobal2 жыл бұрын
What do you think of Hybrid Ductless VRF or Daiken VRC for a residential set up in Florida.. is Ducted or ductless way to go?
@RoastedHVAC4 жыл бұрын
Actually, that's a great job 😉
@mitchelld14324 жыл бұрын
I can't believe I actually looked at the comments to see if someone else actually noticed that.
@HVACS4 жыл бұрын
Thanks! 😃
@hvac-r9772 жыл бұрын
How to do the future services? Is it accessible later?
@jedeckert95256 ай бұрын
Some people just don’t care how their work looks.
@TheCablebill3 жыл бұрын
Does the drain line pitch up from the unit before it travels to the hole in the soffit? If so, would there be a problem with stagnant water during dormant periods?
@barberhvac34383 жыл бұрын
These units unusually come with an internal condensate pump
@LalithBalasubramanian Жыл бұрын
Can you install this unit on an angled ceiling or does it need to be flat at 0 degrees ?
@keenanwalker65973 жыл бұрын
I would have used side beam hangers for the threaded rod but whatever works I guess. Also the wire you used is 14-3 the ground doesn’t count as a wire.
@qomco2 жыл бұрын
Its sold as 14-4
@keenanwalker65972 жыл бұрын
@@qomco no it’s sold as 14-3 ground isn’t included in the number ground is there no matter what
@qomco2 жыл бұрын
@@keenanwalker6597 if you say so. But i install mini splits 5 days a week and its sold as 14 4
@dmac28903 жыл бұрын
How close to a Tv can you mount the inside unit? Mitsubishi says 3' Have you ever seen problems with this distance?
@timfisher773 жыл бұрын
nice,nice,nice,nice,NICE!
@5086nashua3 жыл бұрын
Nicely done. Does the drain line need to have pitch when it follows the line set?
@danbiss872 жыл бұрын
definitely
@hvac-r9772 жыл бұрын
From their AD they said there is a built in pump
@MyBallzGotShocked9 ай бұрын
The pitch looked pretty nice to me.
@FireAlert4 жыл бұрын
Nicely done but please turn down the music just a little.
@AA-zq1sx2 жыл бұрын
I vote to turn it up.... groovy beats!
@wwefan2000geo3 жыл бұрын
How do you measure where to put the eye hooks
@jepito293 жыл бұрын
Here there there here here there
@WheretheJones2 жыл бұрын
What does the "one way" mean? Is it different from other mini splits?
@AA-zq1sx2 жыл бұрын
Apparently it means that it blows only in one direction, or through one vent, as opposed to other square cassettes that have vents on all four sides blowing different directions into the room.
@WheretheJones2 жыл бұрын
@@AA-zq1sx ahhh. That makes sense. Thanks!
@AA-zq1sx2 жыл бұрын
@@WheretheJones It does direct the air up and down and side to side though, to create good circulation... but yah, only one side of the cassette (on the long axis) has venting. The other side sucks in the air.
@anthonylombardi33702 жыл бұрын
How do yes sheet rock the ceiling?
@briancarlisi22244 жыл бұрын
Nice job! You do better work than Bryan.
@HVACS4 жыл бұрын
I can hear you 😂
@josephtramutola5923 жыл бұрын
Don’t forget to Reem your pipe before you flare it
@hillbillymental2 жыл бұрын
The eye hooks are a little Busch league. Could have just used side Sammy's
@briancurtain36364 жыл бұрын
I thought it needed a communications cable. What type gauge wire is that for power?
@fhuber75073 жыл бұрын
He showed the cable. 2 wires for power, one for control and a ground. Look at 3:28 (+/- a bit)
@nwsvndr Жыл бұрын
Can these be used on a sloped ceiling? (What is the max slope?) Thanks
@stepside2839 Жыл бұрын
I watch another video and they said “No” because of drain line. They said the units were designed to be level.
@89brayden3 жыл бұрын
I have knee walls in my attic bedroom. Can these be put on a wall instead of a ceiling?
@xRedstreak3 жыл бұрын
They make mini splits purely for the wall, cassettes are just for the ceiling
@ductlessplushvac3 жыл бұрын
No you need 14.5” inches not 12”
@kentwood29143 жыл бұрын
Would always be nice to not skip steps...like putting the 2x4 on the other side to make up for truss width too wide for cassette...or did you. See, viewer left to make an assumption. Some degree of off angle is surely undesirable.
@captainkangaroo43012 жыл бұрын
What is the minimum vertical clearance required for this unit?
@aaronblair9500 Жыл бұрын
Great question
@4932gb4 жыл бұрын
You sound like Pinkman from breaking bad.
@publicmail24 жыл бұрын
Teflon is ok but has no bearing on seal in this case.
@sylvandaugert62033 жыл бұрын
In some places, it's actually against code to use Teflon on flare fittings. This is because you can easily overtighten as you have reduced the turning resistance of the threads. He compensated by using less torque, but our local gas inspector would have instantly locked the install it he had caught it.
@m.lewizz32973 жыл бұрын
the space above my ceiling are 12 in deep will this unit fit
@786otto3 жыл бұрын
Look at specks think this unit is 7 or 8" deep.
@ductlessplushvac3 жыл бұрын
Yes they work in 12” locations.
@gauravharmale1374 жыл бұрын
can we install cassette ac on 5 metre high ceiling
@gauravharmale1374 жыл бұрын
Reply please
@CockyMike9113 жыл бұрын
@@gauravharmale137 If It were me, I'd use a ducted unit (not a ceiling cassette) and a 3.5" x 14" ducts down the wall to place my registers at about 10' AFF. Depending on the size of the room, you could place a couple and achieve a very satisfactory result.
@josephhathorn15642 жыл бұрын
How many times can you say actually in eleven minutes and seventeen seconds
@soggybottomboys2792 Жыл бұрын
Yeah pvc glue no primer 😂
@codelyoko1996hp3 жыл бұрын
IPhone 11 Pro
@timjones1022 жыл бұрын
my dude u insulated the whole drain but never secured it to anything, what the hell are we doing here
@HandymanHobo Жыл бұрын
Actually 🤦♂️😆
@Mrhappy5553 жыл бұрын
These units are great till they stop working. Then the shit show starts. Remember products don’t last anymore.