In this video we go over thermostats that stay in delays and how to fix it. We also go over different types of shorts. Thanks for watching. Please like and subscribe!
Пікірлер: 44
@elcapitan13062 жыл бұрын
Hours of youtube failed me until i saw this video. Thank you.
@roguefab Жыл бұрын
This is such good info. Keep up the great content. You are helping us homeowners figure out the issues that some techs can't even find!
@ericcrevling37593 жыл бұрын
Man some people don’t have the “ KZbin “ thing down. But you sir need to keep making videos. Excellent content! I am new to the industry so this is all gold for me. Your videos are great. You present yourself like a KZbin pro and deliver the information in a way that us new guys can understand. Keep up the great work!
@HVACTechTips2 жыл бұрын
I appreciate that!
@esthersanchez25392 жыл бұрын
Thank you for explaining this in plain English. Legit the only helpful video on these thermostats on KZbin. Thanks brother
@GlennGrohmann Жыл бұрын
Got my sons system working coil was bad on out side unit. Thank you for the info it saved us!
@tymiller62362 жыл бұрын
Hey dude!...Thanks for this information!...I'm not an HVAC Tech. I am just renting a home that has this exact issue!...I have called for the service technician and i'll show them this video when they arrive!...Thanks Again!
@ashleylink80692 жыл бұрын
What did your problem end up being?
@HVACTechTips2 жыл бұрын
Yea I would like to know too. 😊
@gamingwithdcthetruth854 ай бұрын
Just ran into this problem today, i appreciate it.
@LabradorRichy5 ай бұрын
Thank you soooo very much brother, not all heroes wear capes
@filibertomarmolejo14822 жыл бұрын
Thank you!! You just saved me a call back @ the problem was out side low voltage wire grounded causing t stat to go delay..you helped me to solve the issue
@keemnar6852 Жыл бұрын
This saved me a tone of heartbreak! Exactly what he said it’s a Honeywell and everything!
@jericosha28422 жыл бұрын
For those watching this take note that a lot of smart thermostats, especially Nests, will do this without a blown fuse and might even report, "there's a problem with the Y wire" or something like that. enjoy your videos man, hope you are well
@HVACTechTips2 жыл бұрын
Great point! Thanks so much for watching and I’m glad you enjoy the content.
@FlowerSan Жыл бұрын
I have amazon thermostat which is based on Honeywell thermostat that act like you mentioned, So, I checked out side unit. I found the problem. Thank you.
@KTVARealtor346 ай бұрын
What was your issue? I’m trying to figure out mine but the contractor’s are good, but it still isn’t starting.
@MDKing-mz5dhАй бұрын
Thank you Spike from the Mario Bros movie! (the resemblance is uncanny for reals). But for real, appreciate you.
@hkhsm3593 жыл бұрын
Nice video. Great knowledge and explanation. Thanks for sharing your experience
@willster18632 жыл бұрын
Thank you for the great information!
@lahoucinelamlih25812 жыл бұрын
You're the man, thanks buddy
@tailzzzzzАй бұрын
Can you show a video of how to test and fix it? Steps with the tools, meter, etc... HVAC guy came out for tuneup, changed capacitor, and now I'm getting that flashing cool on.
@chrissipple1018 Жыл бұрын
If it's not blowing the Fues then I would think it's a voltage problem that's causing the thermostat to reset. The Fues is in the hot side of the transformer as you know so with out blowing the Fues I would check the voltage. Good video
@thecoolguy233 жыл бұрын
Yes man looking forward for videos with tips to find shorts!! 👍👍👍
@Scott-hb8pu3 жыл бұрын
I would love to see videos on multiple shorts!
@tomslick2058 Жыл бұрын
It will blink cool on if you lower to soon after it shuts off on its own. Usually around 5 minutes. You can turn off the cool switch off and on if you don't want to wait. But the delay has a purpose. Maybe pressure is to high in the compresure
@frankiec55702 жыл бұрын
What if you’re getting a very long, near hour, delay on both cool and heat?
@nothingness559 ай бұрын
My heat wont work. My thermostat is scrolling the set temp. The set temp numbers are going a million miles an hour. It only can be fixed if I set it to cool then back to heat. Then the heat comes back on ..itll do it every few days
@barbecuebob18363 ай бұрын
I have a situation where I have 3 zones/thermostats. Only when the bedroom thermostat is set to cool rabdomnly it calls for AC but the fan doesn’t come on and unless I catch it eventually will frost the unit. If I do not use the bedroom or if I turn it on only when I can confirm the fan comes on it works 100%. Any ideas?
@sknight03913 жыл бұрын
I've seen the T6's do that a lot when the drain line is clogged and the float switch is killing the power and then it will send the thermostat into a 5-minute delay. Some of the water manages to trickle out but when the unit comes back on and fills the trap and trips the switch again the thermostat goes into another 5 minute delay.
@unknown-qj7oh3 жыл бұрын
Great tip man thank you!
@jamesleroy27843 жыл бұрын
Had that happen on another Honeywell tstat . After replacing fried transformer, , got a call for cool and voltage dropped to 13v . Removed call and had 24v. Sure enough contactor was shorting out . I’ve replaced some shorted contactors blowing out fuses .weird sometimes . But been changing a lot lately. Homer brand
@andrewhemm9162 Жыл бұрын
Could really use some help. Have this Honeywell thermostat and I did have a broken wire out at the outdoor unit. Replaced signal wire the the contactor replaced contactor. Now it only will run the outdoor unit if the thermostat is bypassed. With the thermostat it only runs the fan. No blown fuses
@tonym69203 жыл бұрын
Thanks! 👍👍. Are you seeing this on any particular outdoor unit more than others?
@HVACTechTips3 жыл бұрын
No
@tomlitchfield88542 жыл бұрын
i have a outside unit with air handler in attic works fine but every now and then the thermostat calls for a/c compressor comes on but FAN fails to come on causing low side line to freeze up then i have to reset unit had a few codes Y1 relay , blower communication err and ID MTR err. i feel some how the fan is loosing its signal to come on just dont know where it should be getting it from pcm or thermostat. s
@rokashi21043 жыл бұрын
so i got a question .... contactor chattering ohm it reading 15 ... checked low voltage 26 ... idk what's next ecobee thermostat
@Diego2ThaBay2 жыл бұрын
you sir are the fawking Mannnnnn! thank you very much
@chrisdevine53283 жыл бұрын
Would love to see a extended short video
@Tiger_Gaming90952 жыл бұрын
I tried that didn't work because the temperature reading it's stuck on 74 only in the daytime I put it on 72° only in the night time it does work read the some temperature in the night time only on another thing is doing you feel like it's very cold and it feel like water tripping it feel like it with the the air feel like ok we put it on 72° debating you go to 75 sit point it doesn't work it doesn't go down the same temperature at all I think the something in the unit in calibrate the same level hot and cold temperature level is not right
@jeremyjenningsjjj2 жыл бұрын
the wires have to in the backing plate just right..and no corrosion on them
@johng99023 жыл бұрын
Outside unit I have wasn't turning on last month. Contactor was full of fried fire ants.