No video

What is Surge in Centrifugal Compressor

  Рет қаралды 2,269

HVACTIME

HVACTIME

Күн бұрын

Leave this video understand the concept of centrifugal surge and why it happens. This is a common condition chiller technician will face and need to know how to address.
Chiller Training at chilleracademy.com
Troubleshooting Guides at hvactime.shop
TruTech Tools Promo: HVACTIME

Пікірлер: 10
@enternaty
@enternaty Ай бұрын
Hello Holden, I'm a Centrifugal Heavy equipment technician with 30 years of experience and love looking at you video clips and explanations therein. So I strongly encourage you, to remain committed in your quest to educating our younger technicians who, are not aware of the serious issues and problems they can and will encounter on Centrifugal Chillers, be they the recognized and competitive Models like YORK, McQuay, Daikin, TRANE, CARRIER. Their are newer brands entering the market who have yet to prove their ability to run with the older Models that have been in the field for over 100 years like the old Model White Western House and Worthington etcetera. I liked the old R11's R12's which were phased out. Chillers that worked in a vacuum required a purge unit and the skilled technicians who understood their operations. Positive Pressure Chillers are great and have reduced maintenance cost however, their main principle operations remain the same and require experience operators to understand certain condition and logs. Ahh getting a bit excited here sorry. Anyway, I would like if you can present a video clip on Chiller Stall as well. This phenomenon is also a serious and destructive condition that occurs just before the surge and many younger Centrifugal Chiller operators seem oblivious to this condition as well. Thanks again for sharing your experiences. It is indeed helpful.
@HVACTIME
@HVACTIME 29 күн бұрын
Thank you, it's an honor to be able to teach this stuff. If you know anyone needing training let them know about chilleracademy.com
@deavonsanchez3084
@deavonsanchez3084 3 ай бұрын
Thanks for breaking it down in layman terms.
@symbionese2348
@symbionese2348 3 ай бұрын
A 1963 vintage 350 ton Tonrac experienced surging one time that made it sound and look like it was going to jump off the floor. The system operator was trying for a dual operation of steam and chilled water to use during the transitional seasons, but apparently the heat got into the chilled water and sent slugs of very warm water into the chiller tank, although the chilled water return temperature remained at about 50 deg. F. It was perplexing why adding heat like that to the evaporator side challenged the compressor so much, as the condenser was cool and clean. That machine had a rotor about a foot or more in diameter, judging from the case it was in. The operator never did that again. The chilled water system was retro-fitted into the buildings by a mediocre HVAC company known for overlooking important details.
@HVACTIME
@HVACTIME 3 ай бұрын
Learning chillers can be tough, so I created an accessible training that can go on-site with you! Finish your chiller course understanding chiller systems and terminology at your pace to advance your career! chilleracademy.com
@SuperVerdict
@SuperVerdict 3 ай бұрын
Great vid. Thanks for the info as always
@mallkomoha6823
@mallkomoha6823 3 ай бұрын
Thanks for sharing
@muazzamquamarhaque8828
@muazzamquamarhaque8828 3 ай бұрын
Please make a video on troubleshooting of yk çhiller (electrical/control ) section .and level transmitter calibration.
@muazzamquamarhaque8828
@muazzamquamarhaque8828 3 ай бұрын
Hi I am working on YORK OM Multi stage centrifugal chiller 5000Tr, Evaporator pressure - 35 psi, condenser pressure 117 psi,so compressor lift -82 psid.and machine is working fine. And u were saying lift should be around -60-80psid . So please explain is it ok or lift vary according to model of centrifugal compressor
@HVACTIME
@HVACTIME 3 ай бұрын
There will be variance. One of the benefits of multi stage is improved lift capacity. Trane CVH also run higher lift threshold for same reasons. That level of lift requires really good load and fine tuned water flow to operate smoothly. That is evidence of a well tuned system, good job!
What Stall is in Centrifugal Compressor
11:06
HVACTIME
Рет қаралды 2 М.
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 1,1 МЛН
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 958 М.
Trane Chiller Centrifugal Refrigeration Cycle
43:22
HVACTIME
Рет қаралды 52 М.
what are causes of surge
10:01
Mr Engineer
Рет қаралды 4,3 М.
What goes on inside a Mitsubishi branch controller?
13:03
VrfMadness
Рет қаралды 22 М.
IT'S JUST A DUCT DETECTOR
27:53
HVACR VIDEOS
Рет қаралды 38 М.
YK Surge Troubleshooting: Chiller Training
13:56
HVACTIME
Рет қаралды 1,6 М.
Scroll Compressor Exposed: Understanding Its Mechanical Magic
14:39
The Engineering Mindset
Рет қаралды 252 М.
Brazing Training for HVAC Technician
35:45
HVACTIME
Рет қаралды 75 М.
Surge l Surge In centrifugal Compressor l
13:26
Girish Shinde
Рет қаралды 6 М.
EEVblog #496 - What Is An FPGA?
37:44
EEVblog
Рет қаралды 762 М.
I Should’ve Known BETTER…| HVAC Install
13:05
Quality HVACR
Рет қаралды 295 М.