What Stall is in Centrifugal Compressor

  Рет қаралды 1,794

HVACTIME

HVACTIME

2 ай бұрын

Understand what stall is in a centrifugal compressor. I expalin the process of what a stall does to an centrifugal impeller and what conditions to look out for.
Chiller Training at chilleracademy.com
Troubleshooting Guides at hvactime.shop
TruTech Tools Promo: HVACTIME

Пікірлер: 15
@HVACTIME
@HVACTIME 2 ай бұрын
Learning chillers can be tough, so I created an accessible training that can go on-site with you! Finish your chiller course understanding chiller systems and terminology at your pace to advance your career! chilleracademy.com
@HCheatNcool
@HCheatNcool 17 күн бұрын
Love your stuff and all the work you’ve done for our industry. If I may make one humble request, it would be that you work on your pronunciation of the word prevalent. Pre-Va-Lent 😂
@keithto5990
@keithto5990 Ай бұрын
Very happy and lucky to see this teaching.
@JohnChuprun
@JohnChuprun Ай бұрын
A stall is usually a local event (not the full compressor), a full compressor stall is going to result in a surge - and this can be a cyclical event causing damage.
@brandondb2618
@brandondb2618 21 күн бұрын
We run a York. It’s been in service for about 10 years, it has thousands of stall counts through its service . I’ve never really been able to get a good answer as to if these are design to protect from surge or an actual problem, we do run them at low load at times just because of the design of the facility it’s necessary. But we’ve never had any issues or failures of the machine.
@espinozajc64
@espinozajc64 2 ай бұрын
Excellent
@matthewarndt7770
@matthewarndt7770 Ай бұрын
Psid of DT? 60psid is a big difference in temperature when talking about in example of 123?
@HVACTIME
@HVACTIME Ай бұрын
Correct, i am speaking in context of high pressure systems.
@Stevehevessy
@Stevehevessy Ай бұрын
Could non condensables cause a stall ?
@HVACTIME
@HVACTIME Ай бұрын
Yes
@mallkomoha6823
@mallkomoha6823 2 ай бұрын
Thanks sir, Please can you clarify one point. Surge occurs when pressure ratio is higher than the maximum pressure ratio. Here is maximum pressure ratio a parameter set by engineer on software monitoring tool or is it something else? Thanks
@adamhorn8414
@adamhorn8414 2 ай бұрын
It's a parameter capped by motor hp and impeller compression ratio at full load on motor. When the pressure gets higher downstream of the compressor than your compressor can produce at max it will flow backwards.
@kevinmithnick9993
@kevinmithnick9993 28 күн бұрын
surge: Like the elephant in the room
@forcebewhithyou94
@forcebewhithyou94 Ай бұрын
A video talking about technical,without number is empty prose, number, data, is tech.
What is Surge in Centrifugal Compressor
9:43
HVACTIME
Рет қаралды 1,7 М.
First 5 Steps to Troubleshoot Chillers
12:57
HVACTIME
Рет қаралды 3,6 М.
Slow motion boy #shorts by Tsuriki Show
00:14
Tsuriki Show
Рет қаралды 4,2 МЛН
孩子多的烦恼?#火影忍者 #家庭 #佐助
00:31
火影忍者一家
Рет қаралды 52 МЛН
Scroll Compressor Exposed: Understanding Its Mechanical Magic
14:39
The Engineering Mindset
Рет қаралды 242 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 48 М.
Trane sensor bind in step by step TechView
6:57
Robles
Рет қаралды 13 М.
Why does Discharge Superheat Matter?
12:27
HVACTIME
Рет қаралды 2,8 М.
What is VGD in Centrifugal Compressor
8:58
HVACTIME
Рет қаралды 1,4 М.
Centrifugal Pump Types
9:05
Laney Machine Tech
Рет қаралды 280 М.
Compressor Unloader - HVAC Online Training and Courses
11:37
Aircon Academy
Рет қаралды 141 М.
DX vs Flooded: Chiller Evaporator Types
10:12
HVACTIME
Рет қаралды 1,4 М.
Boeing Compressor Stall Training Video
4:48
Reed Skyllingstad
Рет қаралды 728 М.