HYBRID FREEZER GETS AN INTELLIGEN UPGRADE

  Рет қаралды 22,091

HVACR VIDEOS

HVACR VIDEOS

Күн бұрын

Пікірлер: 124
@alistairmackintosh9412
@alistairmackintosh9412 2 ай бұрын
"So it shouldn't be a big deal". Famous last words...
@ivoryjohnson4662
@ivoryjohnson4662 2 ай бұрын
Especially on a Friday
@cesaralonso5701
@cesaralonso5701 2 ай бұрын
I don’t work on hvac but I always watch from beginning to end . Very interesting and I learn a lot ! Keep up the great content!!!
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks for watching, I'm glad you like then
@achannelwithnopurpose1977
@achannelwithnopurpose1977 2 ай бұрын
I will say that this channel has inspired me to make videos of my own trade work in the fire alarm field. I’ve already made a video where I helped a tech troubleshoot why hornstrobes weren’t making any noise while the panel was in alarm.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
That's awesome, what is your channel name?
@johnstrh1
@johnstrh1 2 ай бұрын
"That traps way crooked" THEMS SOME FIGHTIN WORDS
@DanO181919
@DanO181919 2 ай бұрын
The guy that said that probably want be there on the next videos 😂
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol, but yes
@jamalchilds8485
@jamalchilds8485 2 ай бұрын
Why is a trap needed on the suction line?
@keenanwalker6597
@keenanwalker6597 2 ай бұрын
Intelligen is a game changer. It is my go to equipment now.
@garywelch1964
@garywelch1964 2 ай бұрын
I saw you reduced the suction line after the ptrap , well done. I cannot tell you how many time in nearly forty years I saw this done wrong.kudos to you for expertise!!!
@itsprimetime9865
@itsprimetime9865 2 ай бұрын
it is wrong he's not suppose to do that he should of went with 5/8 right from the coil
@garywelch1964
@garywelch1964 2 ай бұрын
@@itsprimetime9865 No by going 7/8 to 5/8 on a horizontal run there would be trapped oil in the evap.always come out of an evap with suction size to a trap and if necessary reduce at the top of the trap.
@itsprimetime9865
@itsprimetime9865 2 ай бұрын
@@garywelch1964 no
@CameronKettner
@CameronKettner 2 ай бұрын
It needs to be reduced after the 90 going down from the coil but before the 180 degree bend in the trap. The reducer after the trap is going to potentially cause issues with oil being stuck in it. Also if you reduce on a horizontal section of pipe then you cause oil to get stuck in the pipe / possibly evap before the reduction. Reducing it after the trap is definitely better than reducing it on the horizontal section after the coil, but reducing it on a vertical section before the trap would be best, as you would be increasing velocity through the trap helping the oil return. If you you reduce it after the trap you will reduce the velocity through the trap, possibly enough that you will not have oil return.
@kens.3729
@kens.3729 2 ай бұрын
Always Great to See a Business Owner willing to Spend their Dollars. 🤔👍
@jetegtmeier71
@jetegtmeier71 2 ай бұрын
a door sensor record might just be REAL useful when asking if the door was propped too long causing the freezer to warm up too much :)
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Good idea
@melvinlazear8068
@melvinlazear8068 2 ай бұрын
good job as always chris and it was smart of the customer to replace the equipment before it failed completely retired hvac tech in southeast missouri
@rdubinda239
@rdubinda239 2 ай бұрын
I absolutely LOVE the Intelligen equipment, it works SO good where I've installed it.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
That's cool
@jasonyeager9102
@jasonyeager9102 2 ай бұрын
Love the Intellgen line from Heatcraft. I still need to get down to Stone Mountain Georgia for the training so we can provide a better warranty for the customer.
@NorthernS0utherer
@NorthernS0utherer 2 ай бұрын
Im glad he said it my ocd was throwing flags
@jonleiend1381
@jonleiend1381 2 ай бұрын
Theses units are super easy to set up. Spends 15 minutes setting the date and time LOL :-)
@uzlonewolf
@uzlonewolf 2 ай бұрын
To be fair, he said easy, not quick 😂
@jonleiend1381
@jonleiend1381 2 ай бұрын
Could have you skipped setting the date and time manually and just sinked it with your tablet after you got connected?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol
@russellhltn1396
@russellhltn1396 2 ай бұрын
Efficiently is all well and good, but as they press harder for more, the systems are going to get more complex and it will cause problems. Look at all the complex stuff that's been put on cars: Computers to set the mixture, variable displacement oil pumps, fuel pump modules, complex battery management systems, etc. All to squeeze out an extra 1 MPG. And when they go bad, it gets expensive to fix.
@jeffreystinebiser7724
@jeffreystinebiser7724 2 ай бұрын
Always learn something watching you. I really enjoy and watching and learning from you
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks bud
@kat2641
@kat2641 2 ай бұрын
Extremely nice an neat install!!!
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks
@4davebert
@4davebert 2 ай бұрын
Love intelligen, we spec it for all our new builds.
@docdat3468
@docdat3468 2 ай бұрын
The Multisystem board would be great with a notification system to the guy in charge of the equipment that if something goes wrong they can call a tech out
@helmsajr
@helmsajr 2 ай бұрын
Nice work Chris Love the wifi hook up.
@vladlad8341
@vladlad8341 2 ай бұрын
Hey man I really appreciate the extra detail info on the new heat craft units operation and ways to make my work more efficient. I’m in Cincinnati and about to go through heat craft training. Looking forward to what I can improve on.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Good luck, I hear they put on a good class
@marcoferreira226
@marcoferreira226 2 ай бұрын
Nice work, Thanks for sharing tips at the end of the vid.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks for watching
@chrismarku
@chrismarku 2 ай бұрын
Great work, Chris. Onto the next 💪🏼
@johnwalker890
@johnwalker890 2 ай бұрын
Good job Chris........
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks bud
@fshn76
@fshn76 2 ай бұрын
I haven’t ran across an Intelligen system yet. I have a few Trenton units that use an EEV. I really like the EEV setup. From what i have read the Trenton digital controllers are designed and manufactured by KE2..
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I did not know that, interesting
@SAAJ6000
@SAAJ6000 2 ай бұрын
Lets hope you never have to change the defrost heaters with that evaporator install 😂
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
My thoughts exactly
@garypoplin4599
@garypoplin4599 2 ай бұрын
6:33 - You have the condensate drain heater connected to the defrost heater terminals. Would it not be better to connect to the fan circuit to prevent ice buildup in the drain during the call for refrigeration? Thanks for all your detailed video posts. 9:43 - Interesting. I would have expected a class C IP4 private network space (192.168.x.x) rather than a class B. I guess they’re anticipating a lot of devices connecting to each network (over sixty-five thousand hosts per subnet).
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I will discuss this on my livestream this evening 10/21/24 @ 5:PM (pacific) come on over and check it out kzbin.infoMOU3KyZBJr4
@Paul-IE-Repairs
@Paul-IE-Repairs 2 ай бұрын
Definitely work from the top down, that way you don't burn you self on the previous braze joint
@ZeroStatic
@ZeroStatic 2 ай бұрын
Thanks again Chris for another interesting and informative video ❤❤❤
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks for watching
@ZeroStatic
@ZeroStatic 2 ай бұрын
@@HVACRVIDEOS Always a pleasure to see you looking after your customers so well, good tradespeople are hard to find and you certainly seem to be more diligent than most. I am amazed that your customers are so tolerant and allow you to video your work. I wish I were closer to your location but I am in Australia on the other side of the planet. Maybe on my next trip to the USA, I might try and find some time to visit there and buy you some lunch.
@armandodeleon5047
@armandodeleon5047 2 ай бұрын
4:35😂😂😂😂😂BURNN BABY, man I do the same thing all the time🤣🤣
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol
@SproutyPottedPlant
@SproutyPottedPlant 2 ай бұрын
Ooh Heatcraft not Sporlan this time! What an awesome piece of equipment that Multisystem board 👍
@SilentServiceCode
@SilentServiceCode 2 ай бұрын
You are in DST until the first Sunday in November (PDT). If you'd set the locale and DST setting properly on your equipment, the time would work properly.
@ThePowerofElectricity
@ThePowerofElectricity 2 ай бұрын
"This video is brought to you by Heatcraft Refrigeration"? Wait wait wait. I think we go off on the wrong foot here...
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol
@mysticknight9711
@mysticknight9711 2 ай бұрын
3:42 -- safety glasses do not work when they are on top of your hat brim
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Uh oh
@DigitalIP
@DigitalIP 2 ай бұрын
is it possible to add like some kind of coating or a sleeve or something to help prevent rusting on certain pipes etc?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
You could
@SoullessProductions
@SoullessProductions 2 ай бұрын
Sporlan sit down. Heat craft taking this one.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol
@soeveth
@soeveth 2 ай бұрын
Doesnt the Day light Savings question in setup ask if your time zone uses it? for example I live in the central time zone but we dont use DLS where I live so I would say no. But you said that Cali does change its time so that should be a yes.
@Spencer1609751
@Spencer1609751 2 ай бұрын
Are they using stainless steel fasteners on the New Unit?
@skipsandvig8888
@skipsandvig8888 2 ай бұрын
What do you think about the smart defrost option? I’m skeptical.
@RETread-xh6fr
@RETread-xh6fr 2 ай бұрын
Safety goggles to protect the forehead? Nice! 😀
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol, yes
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 ай бұрын
What is the typical superheat with an EEV on a reefer unit. I know comfort cooling very well....but in all my years in this trade and the many reefer units I've worked on.....never touched one with an electronic expansion valve. I know the chillers i work on have typical ranges. Example air cooled chiller is typically 8-10° SH, centrifugal chillers run very low superheat from 0.5°- 5°. I got a kick out of how jazzed you were to see the data on your iPad. It's cool to see reefer equipment getting into the more modern available types of extracurricular controls. As a side note...I wonder if that card has the ability to except AI's....you could use some CT's and see if fans are running, compressor is running, heaters are running....etc etc. Analog Inputs give you the ability to see multiple modulating values.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
8-10 for medium temp 6-8 for low temp is where I aim with eev’s
@johnsullivan3909
@johnsullivan3909 2 ай бұрын
I noticed all copper drains is that code in Cal?
@CSXRailfan6588
@CSXRailfan6588 2 ай бұрын
Most installers would just put in the unit and not bother checking the transformer I see it all the time and the way I think of it it worked like that for years so I leave it because as soon as I change it to be right something will break
@Saatse1
@Saatse1 2 ай бұрын
Hi, is it possible to make this soldering job with induction heater?
@Nyarly_Relyeh
@Nyarly_Relyeh 2 ай бұрын
I wonder, why the door sensor is an option, but not a requed one?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I will discuss this on my livestream this evening 10/21/24 @ 5:PM (pacific) come on over and check it out kzbin.infoMOU3KyZBJr4
@Nyarly_Relyeh
@Nyarly_Relyeh 2 ай бұрын
@@HVACRVIDEOS I do feel pity - 5PM PST is 3:00 AM in my time zone, so I could not watch it live
@4davebert
@4davebert 2 ай бұрын
When you say they beat the hell out of the equipment, I think you may be at one of our locations 😂
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol, possibly
@JAMESR.-xo3tt
@JAMESR.-xo3tt 2 ай бұрын
I like the intelegen system but in my area KE2 is used a lot more
@RefrigerationDevil
@RefrigerationDevil 2 ай бұрын
Why 27 degrees lol 😂, they must really use that box
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
They keep partially defrosted chicken wings in the walk in so they can quickly cook them in the fryers.
@markusbaath3045
@markusbaath3045 2 ай бұрын
Why not use The new press cupling tools and press couplings
@EdwardOrozco12
@EdwardOrozco12 2 ай бұрын
Nice.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Nice
@Fluxkompressor
@Fluxkompressor 2 ай бұрын
Doesn't this condensing unit have a head pressure control valve? You said it does not need it if it has an EEV. Now I'm confused
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I could have misspoke but I’m pretty sure I said it doesn’t have a liquid line solenoid valve if it had an eev….. if I didn’t say that , that’s what I meant to say
@dunckeroo1987
@dunckeroo1987 2 ай бұрын
An open color door can waste lot of energy. Cool room curtain strips or an air curtain could be installed if cooler door needs to be open for extended lengths of time.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
You are absolutely right, it's a good idea to use a curtain to save energy if it needs to be open for a while but often times the customers don’t want them because the cooks ruin the curtains and they constantly have to replace them
@jorgegomez973
@jorgegomez973 2 ай бұрын
Hey Boss does this hybrid freezer uses condensing unit and evaporator for freezer?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Yes
@paulsilver1625
@paulsilver1625 2 ай бұрын
I really hate pump down cut out. So bad for the compressor.
@skipsandvig8888
@skipsandvig8888 2 ай бұрын
@@paulsilver1625 it’s a must with refrigeration equipment with a receiver. Imagine off cycle like ac….and there goes the liquid charge equalizing into the suction line. Very bad for compressors.
@ather1717
@ather1717 2 ай бұрын
Heat craft???
@JP-sd2cw
@JP-sd2cw 2 ай бұрын
cant you damage the system if you power it up under a deep vacuum?
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
I will discuss this on my livestream this evening 10/21/24 @ 5:PM (pacific) come on over and check it out kzbin.infoMOU3KyZBJr4
@JP-sd2cw
@JP-sd2cw 2 ай бұрын
@@HVACRVIDEOS I missed not sure if you answered this.
@dunckeroo1987
@dunckeroo1987 2 ай бұрын
I changed my car's AC to hydrocarbons for the refrigerant : works better and leaks less. It claims to be an azeotrope mixture of synthetic propane and butane.
@glennschlorf1285
@glennschlorf1285 2 ай бұрын
What could possibly go wrong
@itsprimetime9865
@itsprimetime9865 2 ай бұрын
that P trap is gonna cause you issues on the long run ... should of went with 5/8 from the coil
@yinggamer7762
@yinggamer7762 2 ай бұрын
I’m a p trap noobie, how will it cause issues / what is a p trap for?
@itsprimetime9865
@itsprimetime9865 2 ай бұрын
@@yinggamer7762 he shrunk 7/8 to 5/8 on the rise oil will have tendency to drop back down since vapor is light .. P trap or u bend is used when you have a height travel greater thenn ie: 5 ft Different line sizes call for higher or lower p trap uses
@skipsandvig8888
@skipsandvig8888 2 ай бұрын
Actually the connection size p trap and then reduce on the riser is the better method.
@itsprimetime9865
@itsprimetime9865 2 ай бұрын
@@skipsandvig8888 no ....
@yinggamer7762
@yinggamer7762 2 ай бұрын
@@itsprimetime9865 you only need it when the condenser is above the evaporator?
@scottgambers8013
@scottgambers8013 2 ай бұрын
Great job as always very informative. 1 question how come you still braze instead of using zoom lock
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Good question, personal preference, cost, sometimes it's just easier
@JustRickToday
@JustRickToday 2 ай бұрын
WHY DO YOU HAVE CAPS LOCK ON ALL THE TIME?!
@SproutyPottedPlant
@SproutyPottedPlant 2 ай бұрын
The reason is because he put caps lock on and typed! It’s easy to use and free. Some older computers even had a physical latching caps lock key!
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
It's stuck on my keyboard
@andrewcourtney443
@andrewcourtney443 2 ай бұрын
This video is brought to you by WHAT
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Lol
@GentianElezaj-d5w
@GentianElezaj-d5w 2 ай бұрын
just because it is 4 degrees below 32 F doesn't make it a freezer
@steveblake8766
@steveblake8766 2 ай бұрын
678 thumbs up
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Boom
@paulsilver1625
@paulsilver1625 2 ай бұрын
American electrics are amazingly backward. I think
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
How so?
@seagullsbtn
@seagullsbtn 2 ай бұрын
It didn't blow up
@BerryJoyko-u1m
@BerryJoyko-u1m 2 ай бұрын
Ok Thanks for not having that other intro and changing it. no diferent than the other new one you had. very annoying to hear the same thing over and over. not just your vids. everyone uses the same. actually really like your videos. always lern something new. detailed. show all the good stuff. hello from ON.
@HVACRVIDEOS
@HVACRVIDEOS 2 ай бұрын
Thanks bud
@DanielDavis1973
@DanielDavis1973 2 ай бұрын
The way I remember daylight savings is "S"ummer = "S"avings. Spring forward (lose an hour of sleep) - Fall back (Sleep longer). Winter is regular time, Summer is Daylight savings.
DINING AC NOT COOLING ( APPRENTICE SERIES )
40:53
HVACR VIDEOS
Рет қаралды 35 М.
THE ICE CREAM IS MELTED IN THE FREEZER
26:37
HVACR VIDEOS
Рет қаралды 33 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
Enceinte et en Bazard: Les Chroniques du Nettoyage ! 🚽✨
00:21
Two More French
Рет қаралды 42 МЛН
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
HURRY EVERY AC IS DOWN......
31:56
HVACR VIDEOS
Рет қаралды 347 М.
UMM OUR BEER WALK IN IS WARM
31:06
HVACR VIDEOS
Рет қаралды 23 М.
Day In The Life - Commercial HVAC Technician
27:30
HVAC For LIFE
Рет қаралды 6 М.
SOMEONE MESSED UP BIG TIME
28:20
HVACR VIDEOS
Рет қаралды 122 М.
How I built a Mechanical Calculator
34:51
What Will Makes
Рет қаралды 113 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН
THEY ALL SAID IT WAS THE AC LEAKING WATER
41:31
HVACR VIDEOS
Рет қаралды 55 М.
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!