I RAN A NUCLEAR REACTOR in Nucleares!

  Рет қаралды 12,661

Spike Viper

Spike Viper

6 ай бұрын

No game has ever stressed me so much with just buttons and knobs. Today, I alone will run an ENTIRE NUCLEAR REACTOR!
#gaming #nuclear #science
Join Valour: valour.gg/
Follow me on Twitch: / spikeviper
Follow me on Twitter: / spikeviperyt
Official Vooperian Merch: merch.spookvooper.com/
[ Supporters of Vooperia ]
NodeCraft: Fast & Reliable Game Servers
Use coupon code SPOOKVOOPER for 30% off your first server below
nodecraft.com/r/spookvooper

Пікірлер: 52
@BevinEG
@BevinEG 6 ай бұрын
Homer got fired, huh?
@luigirota7964
@luigirota7964 6 ай бұрын
Is another tipe of reactor control zone, this one is much spacious and complicated
@paul44ur
@paul44ur 6 ай бұрын
Yheah
@LavenThaRaven
@LavenThaRaven 6 ай бұрын
Just replaced by someone better if that's what we're going with XD
@ElderonAnalas
@ElderonAnalas 6 ай бұрын
well, when you start a new game to try again, remember to actually connect to the power grid. 1. open the tablet 2. click blue COM button on left 3. inform the city you're operational to connect to the grid 4. wait a couple hours in the game for them to start accepting your power.
@snipusmaximus
@snipusmaximus 6 ай бұрын
This this this this this this lol
@Feuergraf
@Feuergraf 5 ай бұрын
9:40 He said while looking at the turbine integrity flashing warning light :D
@nopegaming2117
@nopegaming2117 6 ай бұрын
Didt activate vaccum pump on condenser. And didnt use tablet to connect to grid, 2 things that could help, hehe
@DoYouLikeMyNameDude
@DoYouLikeMyNameDude 6 ай бұрын
Operating and maintaining steam power plants is literally my profession. (I have a couple short videos of a plant i visited on my channel) I'm making this comment before i watch anything. I am Canadian but we use PSI for most pressure readings and Celsius for temperature. I will assume this is a cold start of the plant and everything is off except maybe for critical cooling of the nuclear fuel. 1. Look at all of your heat exchangers and make sure there is water flow. The valves should be open and the circulation pumps should be on. the last thing you want is a safety popping and filling the whole room with steam because you forgot to check. 2. To bring the plant online you need to make sure that the there is no water in the steam lines so open up condensate drains on all of the cold(room temp) lines. Once steam enters there will be so much condensation it will overwhelm the condensate system. Once the lines are warm enough to start maintaining steam pressure without condensing immediately (20 PSI) you should be able to close the drains. 3. The turbines take hours to start up. They MUST be brought up to temp and speed slowly. Start the turbine barring (slowly rotates the turbine) system and heating. All turbines are different, it could be direct stem heating or indirect case heating. 4. Slowly bring the boiler online (use the nuclear fuel) with low fire/heat. That could be using only one burner out of 10 for a large boiler, or using one burner with a very little fuel going in, or using one fuel rod out of 50 you may have. 5. There are generally several different levels of steam pressure in the plant: 1200PSI, 600PSI, 160PSI, 60PSI, 5PSI to name some common ones. Once you get close (80% ish) to the operating pressure (highest pressure line of the system) start bringing steam-using equipment online from highest pressure to lowest. You want to heat up all of the equipment and make it operable without using more steam than you can generate and vice versa. 6. This is the the part that takes skill, experience, and knowing what you're doing. Everything is primed to be brought fully online. You must now balance the steam/pressure production with the consumption of the equipment as you ramp up all of the equipment. Bring the turbines and heat exchangers online by hand one at a time. Once the turbine generator is synced with the grid looking a the synchroscope put it into power generating mode and then full auto. Assuming everything went well you can put the boiler/steam generator on auto and the plant will run itself and you can relax.
@DoYouLikeMyNameDude
@DoYouLikeMyNameDude 6 ай бұрын
I have now watched the video. My recommendation is to hit the turbine trip on the panel and lower the control rods. Get that plant offline stat. That turbine is not safe to run. You only have 1 of 3 installed so you are unable switch over to a safe turbine and keep the plant operational. Keep the coolant system running. All of the pressures and temperatures will lower and alarms will go off but literally doesn't mean anything because that is the goal. If the turbine trip doesn't work then (OH MY GOD, panic) run down and shut of the INLET steam by hand. Make sure you lower the control rods first before leaving the control room. Repair the turbine and bring the plant online again. Random bits of knowledge that may or may not be applicable to the game: Condenser operation: A condenser that has to little coolant(condensate) could explode/melt and a condenser that has too much is not always an issue; it will just overflow or vent onto the ground or into tank, obviously not the best but better than too little. NCG purging: The vacuum pump is used to remove Non-Condensable Gases. Steam condenses into water, air will not condense. You want *only* water vapor in your steam lines. NCGs usually accumulate in the condenser. Having NCGs in condenser will lower its ability to condense steam into water. If you produce some steam at a VERY low pressure (1-10 PSI), run the pump, and have the condenser online, then air will migrate to the condenser and get removed from the steam system via the vacuum pump. Turn the pump off after purging the system. Turbine safety: Standard practice is to test the turbine trip of a turbine once before being put into operation. There are two types: manual and automatic. Test the manual by hitting the trip button, and test the automatic by safely over-speeding the turbine until it trips. If either fail, fix it before using the turbine. Rounds: Walk around the entire plant, get familiar with the locations, visually inspect the equipment. Leaks happen and you cant rely on instruments to catch it. Rounds are actually a huge deal in real power plants. Backup systems: When not in use make sure they are in automatic. If power goes out you won't get it back if your emergency generator is in manual mode instead of automatic. Steam pressure/temp: The most important thing to monitor is steam pressure. The temperature can go all over the place due to superheat. If the steam temperature is in the red THEN worry. To fix it reduce steam production, increase condenser flow, bring another turbine online, basically anything you can do to increase steam consumption or reduce production.
@michaelbauer4065
@michaelbauer4065 6 ай бұрын
The exam he's taking is the licensing exam to run the reactor.
@jhonshields4330
@jhonshields4330 6 ай бұрын
The condenser and steam generator circulates
@Dropbaud
@Dropbaud 6 ай бұрын
You opened up the generator valve to let it vent. all your coolant is boiling out of the system. Lol
@RadiantCorium
@RadiantCorium 6 ай бұрын
0:22 is incorrect. this game is not very realistic and has a lot of inaccuracies. i do not work in a nuclear power plant IRL, however i have spent a while now researching PWRs (the reactor type this game is apparantly using) and working on a close to 1:1 simulation of one.
@ThatJay283
@ThatJay283 6 ай бұрын
nucleares definitely is not a proper pressurized water reactor. the design is a weird one (according to the devs it's an experimental research reactor) but could still work in theory. of course it does not have nearly any of the safety systems modern reactors have, and gives WAYYY too much control to operators (with barely any automation), and would definitely be worse than Chernobyl's RBMK design in practice.
@RadiantCorium
@RadiantCorium 6 ай бұрын
@@ThatJay283 excluding safety systems, there is generally also still a bunch of systems missing
@delawarepilot
@delawarepilot 5 ай бұрын
You are generating megawatts of electricity in the parking lot.
@jhahn2835
@jhahn2835 6 ай бұрын
I remember watching you like 6-7 years ago good to see your still uploading
@25hawkeye
@25hawkeye 6 ай бұрын
Spike, although I am not a nuclear plant operator, I can teach you this game through multiplayer. I will also explain all the steps you did wrong so you can hopefully not blow up the reactor.
@TheSharpy1012
@TheSharpy1012 6 ай бұрын
ANSWER...The alarm you hear the whole time is due to: You didn't ask the city you were ready to give them power... (in your tablet, comms) Your turbines are being damaged (with alarm) as they are making power while your city doesn't want it yet A recent, In Depth Tutorial was uploaded to YT if your keen to watch? 😇✌️
@TheK0tYaRa
@TheK0tYaRa 6 ай бұрын
23:00 so that's the definition of human factor, huh
@Theoneandonly9038
@Theoneandonly9038 6 ай бұрын
Yeeeeees my lad
@Arakadass22
@Arakadass22 5 ай бұрын
bro you best!!!1
@jaxenkrebs3795
@jaxenkrebs3795 5 ай бұрын
You forgot to close the Release valve for the coolant. Remember it over heating a dumping new coolant.
@lisabrumley9629
@lisabrumley9629 9 күн бұрын
And you’re supposed pull a vacuum on the condenser
@sebbes333
@sebbes333 6 ай бұрын
20:25 Enable a 2'nd steam generator? I assume that should half the... pressure? steam? flow? whatever it is too much of? Also, disable nr 3 generator, because it is almost broken (22% integrity) and enable generator 1 (& 2) instead, then you can repair generator 3 when it is not running (assuming the game has a repairing mechanic?)
@SpikeViper
@SpikeViper 6 ай бұрын
You have to buy additional generators 😅
@pdub4825
@pdub4825 6 ай бұрын
This is so stressful
@opman9939
@opman9939 6 ай бұрын
The reason why your generator is probably at a low condition is because its overworked or because it has foreign substances in it (such as coolant) so there is 3 things you could do to fix it. A: figure out how to connect it to the grid B: allow less steam to pass through or C: allow more or less coolent to pass through (im not sure which would be necessary).
@MattsMadnessOfficial
@MattsMadnessOfficial 6 ай бұрын
What I find fun is to pull the rods out 100% then insert the core lmfao
@luigirota7964
@luigirota7964 6 ай бұрын
I hope you don’t do wrongs stuffs wit this reactor because is open and probably in this case I create a steam explosion 8:22 O no evacuate now o scram the reactor!! 12:42 deamet fortunately the emergency generator is automatic 18:00 another problem
@saladguide7596
@saladguide7596 6 ай бұрын
nice video
@anarmyofbeaker
@anarmyofbeaker 6 ай бұрын
You need to use your tablet on comms to contact the electric company to connect to the grid before you start making power
@jhonshields4330
@jhonshields4330 6 ай бұрын
The integrity may have dropped from the turbine because over pressure it is a little bit hard to explain
@25hawkeye
@25hawkeye 6 ай бұрын
nah, he forgot to connect it to the grid and it damaged the gens
@variegatus4674
@variegatus4674 6 ай бұрын
realistic physics mod when?
@Thatrandomguy76
@Thatrandomguy76 6 ай бұрын
bro you forget to turn upthe condeser
@fast-toast
@fast-toast 6 ай бұрын
Ive had this game for a while now.
@SnowGaming...
@SnowGaming... 6 ай бұрын
imagine if spikeviper
@SpikeViper
@SpikeViper 6 ай бұрын
imagine
@polybius223
@polybius223 6 ай бұрын
I think you left the one drain valve open 18:05
@SpikeViper
@SpikeViper 6 ай бұрын
good catch :)
@hatandtincup8971
@hatandtincup8971 6 ай бұрын
I beg of you: know when to use the S.C.R.A.M button and if they tell you don’t disconnect something DONT just find how to connect it it may be why the turbine broke but I am no expert
@belogaming3695
@belogaming3695 6 ай бұрын
Play more nucleares
@der_echte_dabuking4545
@der_echte_dabuking4545 4 ай бұрын
we can see you have no ideer what you doing. You have more damage of the Generator and other things at the first day then me in 3 ingame days😅..
@fingerknight2759
@fingerknight2759 6 ай бұрын
Is there -a- multiplayer function, Spike?
@SpikeViper
@SpikeViper 6 ай бұрын
Yes
@SnowGaming...
@SnowGaming... 6 ай бұрын
@@SpikeViper play it in stream (real)
@sodamnman7076
@sodamnman7076 6 ай бұрын
Third view
@thebananaking1656
@thebananaking1656 6 ай бұрын
Third
@fingerknight2759
@fingerknight2759 6 ай бұрын
Second (and a half)
@3RR0RNULL
@3RR0RNULL 6 ай бұрын
Fourth (or fifth if you count the reply.)
NUCLEAR MELTDOWN in Nucleares!
16:07
Spike Viper
Рет қаралды 14 М.
The Removed & Lost Easter Eggs of Portal 2
26:10
Ossy Flawol
Рет қаралды 137 М.
The Noodle Picture Secret 😱 #shorts
00:35
Mr DegrEE
Рет қаралды 30 МЛН
The day of the sea 🌊 🤣❤️ #demariki
00:22
Demariki
Рет қаралды 59 МЛН
Children deceived dad #comedy
00:19
yuzvikii_family
Рет қаралды 3,3 МЛН
I made sponges infinitely powerful
10:30
Element X
Рет қаралды 1 МЛН
SINKING THE TITANIC in Space Simulation Toolkit!
28:55
Spike Viper
Рет қаралды 18 М.
I Remastered Getting Over It
5:45
Adam314
Рет қаралды 21 М.
Nucleares - RESCUING a Meltdown
16:02
ShArPy1o1 Game's
Рет қаралды 6 М.
How I made a 3D Level in a 2D Game
24:28
Spu7Nix
Рет қаралды 3,3 МЛН
Nucleares: The Boron experiment
48:20
Gaming With The Hacketts
Рет қаралды 1,6 М.
NUCLEAR DAM MELTDOWN in The Powder Toy!
20:10
Spike Viper
Рет қаралды 305 М.
AI Learns to steal
17:23
Dingus Labs
Рет қаралды 322 М.
400 Years Flash Game Playthrough
18:06
Pivot Story Animator XX
Рет қаралды 292 М.
NUCLEARES: Let's meltdown a reactor!
30:03
Gaming With The Hacketts
Рет қаралды 19 М.
😱ЭТОГО ТЫ ТОЧНО НЕ ЗНАЛ О KinitoPET 2
11:26
Вилли
Рет қаралды 1,1 МЛН
skibidi toilet - season 24 (all episodes)
25:14
DaFuq!?Boom!
Рет қаралды 20 МЛН