I tried to install my own heating and cooling system Pt. #2

  Рет қаралды 5,528

Great Scott Homes

Great Scott Homes

Ай бұрын

During my DIY full gut 2 family remodel, I’m installing a fully ducted furnace and ac. In this part 2 video I tackle the main trunk line and connecting all the supplies / returns.
#diy #hvac #ductwork #renovation #remodel #property #multifamily

Пікірлер: 39
@Failure_Is_An_Option
@Failure_Is_An_Option Ай бұрын
We either have a conversation, or we listen to music. At no point are both going to occur at the same time.
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
Thank you for the feedback!
@GillyGomez
@GillyGomez 3 күн бұрын
good work man!!
@GreatScottHomes43
@GreatScottHomes43 3 күн бұрын
Appreciate it!
@MRobM100
@MRobM100 Ай бұрын
Really great videos man! I think you'll do quite well as a KZbinr - keep plugging along! Well done from 🇨🇦!
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
Thank you so much, truly means a lot.
@AnthonyHuntley-wv4zj
@AnthonyHuntley-wv4zj 28 күн бұрын
Once again making it look easy! We need an outtakes compilation lol
@GreatScottHomes43
@GreatScottHomes43 27 күн бұрын
ahah I’ll make it happen!
@parkerjohnson5420
@parkerjohnson5420 14 күн бұрын
Definitely looks professional..I’m a service technician and have seen some “professional” duct that didn’t look that good.
@GreatScottHomes43
@GreatScottHomes43 14 күн бұрын
I know exactly what your taking about ahah
@tonygunk7600
@tonygunk7600 4 күн бұрын
The line to the vents needs straightening too much restriction on airflow
@potentialhvac6074
@potentialhvac6074 21 күн бұрын
Looks Great! Definitely a some great craftsmanship. A few major flaws on the duct design and the way you attached the coil to the furnace. First off is the RA , not good to blank it off like that especially with AC involved. Next the way you attached the coil to the furnace would be better if you had made yourself one of those nice transitions. The supply looks pretty good, hopefully for your sake you did the numbers . Ductulaters help
@GreatScottHomes43
@GreatScottHomes43 21 күн бұрын
Thank you! Appreciate the input. You’re 100% correct the return size is below the minimum by one inch in both dimensions kinda keeping my fingers crossed on that one, but I don’t think it will matter. Per the installation instructions the coils permitted to mount straight to furnace with no transition but I did make a very small offset to help in that regard. I had some help with sizing and all supplies have dampers to be balanced later.
@jhippl
@jhippl Ай бұрын
music is so loud i can barely hear you, other than that you did a great job
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
Thank you for the feedback!
@toyotabeast527
@toyotabeast527 Ай бұрын
Awesome work! keep it up and your channel is going to blow up man! - Can i ask how you were able to determine what size unit / air handler you needed and what size and type ducts?
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
Thank you so much! There was never a formal manual j or anything done for this apartment it was just sq footage based. From what little knowledge I have you have to screw up pretty bad for a unit to be so over or under sized, that’s it problematic. As for duct sizing I would recommend watching another video specifically for it, not enough space in the comments for that topic, but as for individual supply ducts, for the most part are all slightly over sized with dampers so I can perfectly balance the system later. I did bounce a few things off an hvac friend which helped me sleep at night ahah. 80kbtu furnace and 2 ton ac.
@AaronPowellvox
@AaronPowellvox 27 күн бұрын
14” return isn’t very big. Not sure what your tunnage is. Hopefully with the one for the bonus room you’ll have enough return. Your work is excellent though. I’d hire you for sure!
@GreatScottHomes43
@GreatScottHomes43 27 күн бұрын
well I hope with the additional 8” we should be good. 2 ton ac, thank you so much!
@AaronPowellvox
@AaronPowellvox 27 күн бұрын
@@GreatScottHomes43 awesome. That sounds good. Be sure to check your fan speed on the furnace. It looks like that one probably maxes out at two tuns but it doesn’t hurt to read the manual. Again, great work on this system.
@octane4life683
@octane4life683 21 күн бұрын
Did you read the instructions dude? There's a big section in there about horizontal left and right installations about required transitions when evaporator width is larger than furnace. Be careful with putting ducts directly on to end caps, bad balance and static issues, velocity and static are not the same thing however they affect each other. Trunks lines you would want to come out of the sides of trunk, the 8" side.
@GreatScottHomes43
@GreatScottHomes43 21 күн бұрын
Appreciate the input, the coil’s installation instructions allow for no transition but as you saw I made a tiny one to help a little. Yeah, the supply on the very end was intentional. With that particular supply being significantly longer than all the others, I wanted to steal as much static pressure as possible to actually help balance later. I’m actually not to sure about the take offs on the smaller dimension of trunk, could you elaborate?
@jor4288
@jor4288 Ай бұрын
Please be careful! You are encouraging me to do my own ducting!
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
Nothing wrong with that! 🤙🏻
@jameswinkle
@jameswinkle Ай бұрын
What gauge (26?) galvanized sheets are you using and how much were they for looks like 4x8 stock?
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
3x8, 26g, for roughly 30 bucks
@Shermgoose
@Shermgoose 2 күн бұрын
no duct seal on the elbow's gores????????
@GreatScottHomes43
@GreatScottHomes43 2 күн бұрын
I went back and taped em’
@serlalonde8420
@serlalonde8420 27 күн бұрын
25 year hvac guy here. Does look good for not being a pro, but looks arent everything. you should NEVER blank off return of unit. they are sized that way for a reason. and then putting a 14" flex only is no good. not only will furnace sound like a freight train but it will screw up static pressure of ducting and likely shorten the life of the system. should have a 16" or better yet 18" and 24x30 return intake. not sure where youre located but here in La. with our high humidity, heat exchanger would rust prematurely and compressor would likely have a short and miserable life
@GreatScottHomes43
@GreatScottHomes43 27 күн бұрын
located in New England and there’s an additional 8 inch return for finished attic
@FlaminChicken231
@FlaminChicken231 Ай бұрын
oh boy...
@GreatScottHomes43
@GreatScottHomes43 Ай бұрын
🙃?
@stevesolt4036
@stevesolt4036 21 күн бұрын
Talking and music never works. Rather have no music at all.
@GreatScottHomes43
@GreatScottHomes43 21 күн бұрын
Thank you for the feedback
@mitchdenner9743
@mitchdenner9743 8 күн бұрын
I kinda like the music during the time-lapse . Other than in the intro , didn't see much music and talking going on. Watching you crossbreak with a paint scraper was interesting. I can't say I've ever seen it done that way.😆 I'll give you points for using metal for one, and neatness always counts. Even though there are design flaws, i bet it performs a lot better than some of the absolute garbage octopuses 🐙 I've seen in my day. Good job!
@emidiolopez1409
@emidiolopez1409 15 күн бұрын
Ngl it was an easy one but seems like you struggled a bit 😩 and let’s not talk about the duct sizing.
@GreatScottHomes43
@GreatScottHomes43 15 күн бұрын
I’d be very curious to see what your first experience with ductwork looked like, also I think we should talk duct sizing… let’s hear what you got.
@emidiolopez1409
@emidiolopez1409 15 күн бұрын
@@GreatScottHomes43 Too bad I can’t post videos or pictures here in the comments so I can show you how it’s done but not bad for your first time though
Air Conditioning isn't free... but we're close.
25:45
Tech Ingredients
Рет қаралды 1,1 МЛН
New Heating And Air Conditioning System Installation   -Start To Finish-
39:18
🤔Какой Орган самый длинный ? #shorts
00:42
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 12 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:26
CRAZY GREAPA
Рет қаралды 21 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 33 МЛН
HVAC Installation Team
16:05
AC Plus Heating & Cooling
Рет қаралды 10 М.
DIY R-39.3 Foam Board Installation For vaulted ceiling and flat roof
18:36
Great Scott Homes
Рет қаралды 1,1 М.
Cheap Geo Thermal Air Conditioning
14:57
Simple Tek
Рет қаралды 1,4 МЛН
I just can't work for angry customers. Had to quit this one!!
28:34
Bondo Built
Рет қаралды 5 МЛН
Flex vs. Rigid Metal AC Duct - My preference may surprise you!
11:52
How I Replaced a HVAC Split Heat Pump By MYSELF!!
13:13
Quality HVACR
Рет қаралды 134 М.
Plasterboard HACK | Every DIY'er Should Know
11:29
On The Trowel
Рет қаралды 519 М.
Stop the Smoke, Do THIS to Your Fire Pit
16:15
Fix This Build That
Рет қаралды 8 МЛН
Попадет ли ему вода в нос?🧐 #моястихия #swimming #юмор #fun
0:33
МОЯ СТИХИЯ | ПЛАВАНИЕ | МОСКВА
Рет қаралды 2,4 МЛН
Проверил, как вам?
1:00
Коннор
Рет қаралды 3 МЛН
На сколько опасна рыба меч?
0:40
Fact Fusion
Рет қаралды 2 МЛН
Reuse3♻️
0:25
Yoshipapa / よしパパ
Рет қаралды 11 МЛН
Small Act of Kindness is also a charity
1:00
PainCare _Trust
Рет қаралды 22 МЛН
Footballers Crazy Water Pool Challenge 🌊
0:27
Football Life
Рет қаралды 11 МЛН