Hi Lance hope your well. I've recently refurbished the hydraulic lift cylinder on my JD 2120 followed your 2130 video as they are the same style set up. Do you know the procedure for setting up the quadrant lift lower lever as there is a Access plug to gain entry with a screwdriver to adjust the clearance on the lift lower valves the top cover is now back on the tractor. Just need to know how you go about setting up that tapered rockshaft screw. Many thanks from the UK. 👍
@BundyBearsShed3 жыл бұрын
Adjust so there is around 10mm lever travel in position control. Screwing in makes it too loose and out (anti clockwise ) tightens it up.
@tricky69023 жыл бұрын
@@BundyBearsShed Nice one mate, thanks 👍
@PaulCTownsend Жыл бұрын
We call that anaerobic sealer.
@BundyBearsShed Жыл бұрын
Yes that is the correct technical term.
@martykath44272 жыл бұрын
Where's the float??
@BundyBearsShed2 жыл бұрын
They dont have one it is an overflow system and once the chamber has enough fuel it flows over a dam wall and run back to the fuel tank.
@martykath44272 жыл бұрын
@@BundyBearsShed Similar to some 3.5 hp Briggs and Stratton. Will have to ring you soon about Bare or Vapormatic multipower up grade parts for a MF 135