Injector Bypass Kits: How To Increase Flow & Reduce Rinse Time On Your Pressure Washing

  Рет қаралды 25,387

Powerwash.com

Powerwash.com

Күн бұрын

In this video, you'll watch injector bypass kits that can speed up your work. Your downstream injector valve will restrict your flow if you leave it in place while you rinse. Use an Injector Bypass Kit to increase your flow and dramatically reduce your rinse time. Buy the bypass kit here - www.powerwash.com/downstream-...
The downstream injection is a means of applying chemicals with the use of a pressure washer. It introduces chemicals into the system after the pump, so no chemical is running through the pressure washer pump itself.
For this demonstration, we're using an 8 GPM Deluxe Prowler: powerwash.com/shop/equipment/...
I’ll show you how to speed up your work on power washing to use a bypass injector kit.
The downstream injector works by maintaining a certain PSI on the pump side of the injector by means of an orifice installed into the injector body. The pressure washing industry rates injectors by the GPM of the pressure washing system.
In the test, we use a popular underrated downstream injector on the machine that you will see. This downstream injector rated 3 to 5 gallons per minute and it has 2.1 orifices on it. A lot of people use it for washing houses because it allows them to draw higher concentration into their line due to the amount of pressure that’s created inside of this downstream injector.
The problem is that the injector restricts water flow during the rinsing stage. Using a Bypass Injector Kit allows the flow to go around the downstream injector. This means when it turns on, it follows around the downstream injector and keeps ongoing. The Injector Bypass allows the water to flow with less restriction.
This injector is called a Bypass kit because you can close the ball valve and bypass the chemical injector when you don't need it. This allows you to quickly switch between cleaning with chemicals and cleaning with only water.
Chemical injector bypass kit allows full flow around the chemical injector for rinsing or surface cleaning. This Chemical Injector Bypass Kit runs like a regular downstream injector. It is called a Bypass kit because you can close the ball valve and bypass the chemical injector when you don't need it.
I hope you enjoy and learn something new from this injector bypass kits video. If you have any questions regarding this video and the tools that I have used then feel free to comment below.
To learn more about power washing equipment, check out Power Wash University's online courses:
Power Wash 101: www.powerwashu.com/more-about...
Power Wash 201: www.powerwashu.com/more-about...
House Washing 301: www.powerwashu.com/house-wash...
I also encourage you to subscribe to my powerwash.com channel to stay tuned for more updates.
Like, comment, and share this video.
You may also like some other videos:
Downstream Injector: How to Use a Super Downstream Injector for Pressure Washing
• How to Use a Super Dow...
Delux Super Soaker Downstream Injector | General Injector VS Super Soaker Injector
• Delux Super Soaker Dow...
Color Marking Surfactant: How To Use Dual Port Injector For Soft Wash
• Color Marking Surfacta...
How To Remove Rust Stains From Concrete
• How To Remove Rust Sta...
Rust Remover Plus - The Best Rust Remover
• Rust Remover Plus - Th...
Most Effective Way To Use Max Quat To Fight Covid-19
• Most Effective Way To ...
How To Clean Roof Safely
• Roof Washing: How To C...
Website 👉www.powerwash.com/
Get training 👉www.powerwashu.com/
Subscribe 👉 bit.ly/2RORVQF
Facebook 👉 / powerwashcom
Instagram 👉 / powerwash_com
#InjectorBypassKits #Powerwash #Pressurewash

Пікірлер: 47
@Powerwash
@Powerwash 3 жыл бұрын
*Buy the bypass kit here - **www.powerwash.com/downstream-injector-bypass-kit-assembled.html*
@stephenserven3748
@stephenserven3748 4 жыл бұрын
Wow thank you, bro, 3 videos and I have learned a lot of good stuff
@emandujano6777
@emandujano6777 4 жыл бұрын
Great video!!! Can't wait for more!
@littlespressurewashing
@littlespressurewashing 2 жыл бұрын
Great video buddy
@rickbest7361
@rickbest7361 3 жыл бұрын
Yes sir that all changes depending on a the tip selection
@mikerue2423
@mikerue2423 3 жыл бұрын
Thanks for the video. I would have liked to have seen the test done with high pressure tips and gauge so we could see the pressure increase with the bypass open both with the correct size injector (2.3 mm) and the 3 to 5 GPM (2.1mm) undersize injector.
@andreamanning2869
@andreamanning2869 2 жыл бұрын
That's cool. 😁
@igorverdes
@igorverdes 2 жыл бұрын
do you prefer this over the remote shut off? You can rinse faster with the bypass but you need to walk to the machine every time.
@littlespressurewashing
@littlespressurewashing 2 жыл бұрын
👍
@motoredline2910
@motoredline2910 4 жыл бұрын
Its is good to have. I don't think it is a needs for the equipments. Since machine is already producing +GPM than what it was mentioned. 😁😁
@nadzkie7313
@nadzkie7313 2 жыл бұрын
hello, how to reduce water from pressure while using injector to make more foam than water??
@slim439
@slim439 2 жыл бұрын
Why not move the injector to the "loop", then you'll have an unimpeded flow, thru the ball valve.
@MannyAguilarJr
@MannyAguilarJr Жыл бұрын
Easy to say from the future
@Nathan-wf1pr
@Nathan-wf1pr 3 жыл бұрын
Thanks for vid! I have similar machine. Say, is it ok to run the machine without any tips like you did in your water volume gpm test? (Does the pump need a certain amount of backpressure?) So can I rinse with a ball valve , without a wand and tip? Also, if you did have a wand and tip for your gpm test, would that have made a restriction to maybe make the test come out to 8 gpm instead of 9?
@Powerwash
@Powerwash 3 жыл бұрын
It doesn't hurt to run it without a tip. Tip size will effect the GPM and PSI. So it is important to use a nozzle chart to find the right size the achieve the desired PSI and rated GPM
@Nathan-wf1pr
@Nathan-wf1pr 3 жыл бұрын
@@Powerwash thanks for the fast reply! Have a good one. -nate
@Mobileblaster
@Mobileblaster 3 жыл бұрын
Wouldn't a quick connection do the same job just unclip the injector and clip the hose back in? Granted its not a quick a turning a valve but would be cheaper option?
@Powerwash
@Powerwash 3 жыл бұрын
Yes, it would but that time savings is the point of using the bypass
@Mobileblaster
@Mobileblaster 3 жыл бұрын
@@Powerwash yeah I was thinking only reason for leaving injection in was for speed. I've just got a water powered mixing stem well tap or 12v pump can go before the SH so all the pump is pumping is water to the T like unit that doesn't matter if 1gpm or 20gpm is flowing through it. Will mix perfectly all the time fully adjustable I've some more practicing to do with it but you guys over pond will love it am sure cheap ish well about the same as a softwash mixing system and it's SH safe also they sell 1 that's hydrofluoric safe 😊 perfect mixing small light and by looks of things very well made I will be doing a video about how it works fairly soon come on over next week or so 👌
@Powerwash
@Powerwash 3 жыл бұрын
@@Mobileblaster Sweet!!! I look forward to seeing the video.
@577buttfan
@577buttfan Жыл бұрын
Engine RPM also plays a roll in the gpm not being perfect. I need to get a bypass you guys still have them in stock.i also need a brass unloader block for mounting it?
@Powerwash
@Powerwash Жыл бұрын
Give us a call 1-800-433-2113. We got what you need
@577buttfan
@577buttfan Жыл бұрын
@@Powerwash Awesome thanks!!
@tjmars37
@tjmars37 4 жыл бұрын
How do we know the engine didn't slow down towards the end since it was running on fumes? I get the concept but not totally sold. Maybe try another video, injector first then followed by bypass?
@Powerwash
@Powerwash 4 жыл бұрын
Thanks for the comment. The engine speed did not change as you would have heard it changing speed in the video.
@igorverdes
@igorverdes 4 жыл бұрын
any difference if you remove the both from line?
@Powerwash
@Powerwash 4 жыл бұрын
I don't understand your question. Can you please rephrase it.
@igorverdes
@igorverdes 4 жыл бұрын
Powerwash.com if you remove the bypass and injector and connect the hose directly to pump, will it be more flow than 9 gallons per minute?
@Powerwash
@Powerwash 4 жыл бұрын
@@igorverdes Maybe a very very small amount. You would not be able to notice
@johtapia1
@johtapia1 Жыл бұрын
01:06 😂
@justinlopez4499
@justinlopez4499 2 жыл бұрын
There’s absolutely no noticeable difference that will save you any time, the bypass is only good for rinsing your down streamer if you have a shut off valve on it. I think it rinses itself anyways when not drawing chem but not 100% on that.
@Powerwash
@Powerwash 2 жыл бұрын
You most likely won't notice it. That is why we did the demonstration. But it does make a difference and will save time. Thought it may be small it will add up in the long run. If you find ways to continually make small improvements it will pay big benefits over time. This is one of those small improvements.
@brandonlambert8021
@brandonlambert8021 Жыл бұрын
It's basically a 10% increase in flow, how is that not a noticeable difference?
@freddiebebop
@freddiebebop Жыл бұрын
10% is 10% none the less. 10% adds up over time. I'd like to have 10% of a million dollars right now.
@HouseWashingRick
@HouseWashingRick 4 жыл бұрын
2.1 , is that 2 gallons of water to one gallon of bleach?? or 2 gallon of bleach to 1 gallon of water
@Powerwash
@Powerwash 4 жыл бұрын
2.1 is is the size of the downstream injector orifice. It has nothing to do with mix ratio.
@HouseWashingRick
@HouseWashingRick 4 жыл бұрын
@@Powerwash ok ty . why is it called 2.1 sir
@Powerwash
@Powerwash 4 жыл бұрын
@@HouseWashingRick because the hole that goes thru the down stream injector where the water flows thru is a 2.1 orifice per the manufacture, General Pump.
@HouseWashingRick
@HouseWashingRick 4 жыл бұрын
understand ty much
@r.a.m.productions1229
@r.a.m.productions1229 2 жыл бұрын
I have a question if anyone can answer. I'm not sure if I'm right, or severely math-challenged. I'm using straight 10% SH (No dilution) My machine is pulling 7:1 This means I'm spraying 1.25% SH? It's been a long day. If my mix is 50/50, I'm spraying .63% SH? We hope to be up & running within a month. Here in Central Florida.
@TheGravygun
@TheGravygun 4 жыл бұрын
3/4 or 1/2 gallon is not going to make a big difference the only time I shut the injector off as if I'm doing flatwork
@Powerwash
@Powerwash 4 жыл бұрын
Yes, it helps considerably with the surface cleaner as well.
@ktpowerwashing
@ktpowerwashing 4 жыл бұрын
Mike is Right, it makes a difference, 1/2 - 3/4 gallon doesnt sound like much but keep in mind that test was based on 1 minute. Take your average rinse time and then factor in the loss of flow. Great video Mike. Of course removing the injector for rinsing is the best method but it takes time to shut down, remove injector, and restart. I added a ball valve on my jump hose right before the hose reel. Pump, 8 foot Jump Hose, ball valve, injector, hose reel. Instead of switching to bypass, we close ball valve, remove injector, open valve and continue spraying. Kind of annoying though when u want to soap again. I feel like I get a lot more flow with it removed vs. bypass. Will do a similar test tomorrow to see. Thank u for the videos Mike. www.KtPowerWashing.com
@xtremepowerwashing1815
@xtremepowerwashing1815 4 жыл бұрын
@@ktpowerwashing the bypass works great. One thing you need to do is switch the location of the ball valve and the injector. This way you get a straight line of flow when rinsing or using a Surface Cleaner versus the water going around the loop in the bypass setup.
@ah-rr1lk
@ah-rr1lk 2 жыл бұрын
Incorrect. You will speed up cleaning time by about 9%. For every 10 hours you will get an hour saved. If you do 40 hours a week thats 4 hours. If you do 52 weeks of work in a year full time thats 208 hours. Which is 5.2 weeks of work. Damn near a month and a half you saved to be more productive. That's worth $100 to me
@brandonlambert8021
@brandonlambert8021 Жыл бұрын
@@ah-rr1lk All of these comments I'm reading and you're the first person that understands the math of it.
Color Marking Surfactant: How To Use Dual Port Injector For Soft Wash
14:31
Installing Bypass Injector And Why YOU Need One For Your Pressure Washer
8:34
King Of Pressure Washing
Рет қаралды 10 М.
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 41 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:25
CRAZY GREAPA
Рет қаралды 20 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
Pressure Washer Downstream Injector
15:44
Doug Rucker
Рет қаралды 2,3 М.
How to Use a Super Downstream Injector for Pressure Washing
7:40
Powerwash.com
Рет қаралды 205 М.
Downstream Injector Bypass. How and Why it works
15:58
Powerful Improvements
Рет қаралды 21 М.
DIY Automated Downstream Injector Box
39:59
Neptune Clean
Рет қаралды 19 М.
Draw test on new check valve injector
7:51
Powerful Improvements
Рет қаралды 13 М.
Pressure washer chemical injector problems
15:27
Brian Shumack the repair guy
Рет қаралды 64 М.
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 41 МЛН