Thanks for sending viewers to my pressure testing video of the push fit fitting 😉 I installed a kitchen tap for my sister a few weeks back, and noticed that the “plumbers” that installed it had used plastic pipe- with NO INSERTS! I was shocked, so decided to test out plastic pipe on the pressure test bucket, without the inserts. I pumped the bucket up to the maximum (over 50 BAR) and not much happened. I expected the fitting to pop right off the pipe, but it didn’t! Obviously the test was done with cold water and I am in no way suggesting that inserts are not used! I would imagine that if hot water was used, you could get very wet- very quickly due to the expansion and contraction. You have a great channel and some good subscribers, congratulations! Greetings from Darwen, Lancashire.
@bigclivedotcom5 жыл бұрын
I think most of the issues may be people forgetting to pop the inserts in or ramming rough ends through the O-rings and scratching them. I'm wondering how adversely the sudden hammer from washing machine solenoid valves will affect the joints.
@ultimatehandyman5 жыл бұрын
@@bigclivedotcom I would imagine that would have a huge effect on the fitting, especially if the house had high water pressure to begin with. It might not fail immediately, but after a few hundred wash cycles there is a good chance that the fitting will let go of the pipe. Thanks for the reply 😉
@mikefochtman71644 жыл бұрын
@@bigclivedotcom Here in the 'states' we use PEX with various fittings (I like 'SharkBite' which is a brand name that doesn't use inserts at all). I've always told myself that the 'give' in PEX piping probably absorbs the hammer shock better than copper. But maybe I'm just wishful thinking. My washing machine doesn't have any hammer arresters.
@keirstitt8277 Жыл бұрын
So long as it's held under good pressure I'm not sure it would be that bad with hot either - but not recommended. I had a leak in my shower which turned out to be a missing insert on the pipe from the valve to the outlet - obviously this bit of pipe is basically at atmospheric every time I turn the shower off. The cowboy who installed that shower has created a lot of problems over the years for me 🤦
@sziltner5 жыл бұрын
PEX, the absolute best! It will last longer than we will! No more worry about copper degrading and pin hole leaks. What a refreshing video change. Hopefully you have more plumbing projects. Electrical and plumbing, is there anything better? Well, maybe eating!
@a.h.22765 жыл бұрын
Agreed but please no eating. We already have too many mukbang videos on this shit hole of a platform.
@khaitomretro5 жыл бұрын
It'll be the rodents eating through the pipes you'll need to worry about.
@garyphillips79935 жыл бұрын
The pipe may outlast us and ultimately add to the plastic waste we're drowning in, but the rubber seals inside won't. They degrade and have a lifespan, depending on manufacturer, up to 20 years, many much less. It was reported many years ago that the pin holes appearing in copper pipes into houses was caused by a combination of impurities in the copper reacting when the cold water pipe was used as the main earth for the house. I know from bitter experience living in a 50's built house 😠
@wobblysauce5 жыл бұрын
+
@ShotgunpleaseNOW5 жыл бұрын
Yeah Pex is alright but copper will last a lot longer at least in Australia where we don’t have frost temperatures, besides pex lets diy dickheads to do their own plumbing then wonder why their house is flooding
@PhilipBallGarry3 жыл бұрын
I first used Speedfit (or similar) plastic pipe and fittings about 10 years ago. A neighbour came round to help me move a radiator in the bedroom onto an adjacent wall. He recommended plastic but I was a bit dubious - especially as the floorboards were going back down afterwards, then a new carpet and I was worried about how secure these new kids on the block would be in the long term. It certainly made the job easier though and we simply re-routed the existing pipework by drilling a 15mm hole in each joist and pushed the plastic pipe through. I even used plastic fittings for the final 90 degree elbows, but for the vertical feeds I did use copper. Or rather, I cut the existing copper pipe just beyond floor level. The ridiculously simple "push on" fittings couldn't be any good I thought - as I usually used solder ring fittings. But, the system was refilled, bled and there were no problems at all. I save a few hours overall. The only thing to remember is that you don't use plastic pipe or fittings within the first (or last) 1 metre from the boiler.
@-EC002-5 жыл бұрын
Under floor heating generally uses 16mm Pex-Al-Pex piping.Very reliable in my experience.
@jmonsted5 жыл бұрын
I love installing PEX, but the real question is how long it takes before it degrades and falls apart. Hopefully never, but...
@peterfitzpatrick70325 жыл бұрын
@@jmonsted pex-al-pex has an inner core of aluminium coated inside & outside with pex material, it also comes pre-insulated & when bent it maintains the angle of bend unlike plain pex... 😎👍☘
@jmonsted5 жыл бұрын
@@peterfitzpatrick7032 Yep, i used it for a couple of runs where i needed insulation (mostly the home runs from the distribution manifold back to the boiler). It's even nicer to work with, but at a quite significant cost. PEX alone is still a god-send compared to metal piping (especially the cast iron i replaced).
@rickhunt31835 жыл бұрын
Pex pipe tubing is the future. The key is making sure you have the proper connections or there will be leaks a few years later. The install is about 10 times faster than pvc. I haven't had any problems and don't expect any because I won't use cheaper connections and I always use tools that are made for commercial applications. When possible.
@howlingwolven5 жыл бұрын
@@jmonsted This is why Poly-B was banned.
@wimwiddershins5 жыл бұрын
I imagine the clever spring pivot thing allows the silicon stopper to find its own location on the outlet port. If it was a rigid hinge there's a chance the two would fail to align and water could ooze through. These things have a lot of thought & experience put into their design resulting in quite elegant solutions.
@bigclivedotcom5 жыл бұрын
That's probably it.
@CoolerQ5 жыл бұрын
@@bigclivedotcom My guess is that the spring mounting allows a vacuum in the plumbing to suck in air. Not sure why they'd want that.
@manolisgledsodakis8735 жыл бұрын
The stopper is silicone not silicon.
@agvulpine5 жыл бұрын
@@CoolerQ I estimate that the pivot type used exerts a stronger spring leverage against the sillycon seal. A fulcrum at the other end could allow weak forces against the lever to prove Archimedes was right.
@AngDavies5 жыл бұрын
@@CoolerQ These things are sometimes referred to as "pressure/vaccuum relief valves" so you're probably spot on, as the water empties out of the tank/ it cools something needs to replace what's gone out or the pressure is going to drop, and despite being much lower than the maximum expected positive pressure, tanks are in general gonna be much worse at withstanding negative pressure than positive ( positive pressure is stabilising, it wants to round out the tank. Negative pressure is destabilising - it's going to tend to amplify any asymmetry and buckle it inwards, causing additional strain on that area and leading to a sort of cascading failure). funnilly enough the negative pressure need not be limited to a vaccum - in the worse case the pressure can drop substantially below vaccuum pressure. Water is not a gas, it sticks to things and can "pull" as well as "push", in low pressure it will boil and reduce that somewhat, but not necessarily enough to keep the pressure above 0. This would however probably only apply to tanks on an upper floor, and would be a bit contrived, but even vaccuum could be dangerous enough. The negative pressure effect can be seen nicely with very tall trees, like redwoods - the tubes that carry the water are very smooth and there's nothing for the water to nucleate off to start boiling and thus the water can be put under the ~negative ten atmospheres of pressure required to pull water all the way to the top.
@DavidRead525 жыл бұрын
I have used plastic pipes for about 20 years and with everything it's all about the installation of the pipe there are three rules for plastic. 1. Be very clean and keep dust out. 2. Copper joints only use a wheel cutter and 3 KEEP EVERYTHING CLEAN. The failures I have seen is mostly about dust from building sites and the only other thing is people not pushing the fitting in far enough usually by not cutting on the marks. ALWAYS ALWAYS put inhibitors in your central heating as the Aav you showed will leak as it's the water pressure that makes the final seal and the smallest amount of dirt will make it leak. Finally the air vent you discribed as a wetting o ring would not be put on a sealed system and are for open vented systems. Love all your vids as I am from the "other side" as a heating engineer that dabels in electronics.
@DrCyberpunk19875 жыл бұрын
I was told by a friend who was a builder that he'd worked on systems done in plastic, it's very important to provide a lot of support for the pipework.
@EDWARDLOMBARDI-z8i10 ай бұрын
Thank you! Saved me the trouble of taking the device apart to make sure you could leave the cap loose all the time VS opening it periodically to "bleed" the air out like I do with my radiators!
@RobertRoberts3295 жыл бұрын
We had tons of pinholes in our nearly 40 year old copper pipes. We had the entire place repiped in PEX (cross linked polyethylene) and the plumber who did the work used steel ripped connections. So far so good.
@DisabilityExams5 жыл бұрын
Let us know in 40 years
@JGnLAU8OAWF65 жыл бұрын
@@DisabilityExams it is a lot cheaper than copper
@robinturner23005 жыл бұрын
I now use Hep2o PEX pipe and this has stainless steel inserts which grip inside the pipe and you can feel when they are seated if you twist them. Very reliable and much more frost proof than copper. Also easier to pull into place when replacing copper given the flexibility. They are known as shark bite fittings BTW not compression.
@HighestRank5 жыл бұрын
There was a huge bout around requiring ID in order to vote locally due to a disenfranchised barrier island population... yet the naturally-gerrymandered minority couldn’t even be considered as indigenous Americans because of their skin color which proved the fact that their entire history was less than prehistoric, and ergo. tiger’s stripes belong on a tiger... which impasse was solved post haste when, to address copper theft fatalities, ID became simultaneously-required for both international flight and exchange recycled metals for cash. So the same water which made them unite also broke them apart.
@daveayerstdavies5 жыл бұрын
Properly installed good quality copper pipe and fittings will last indefinitely. O-rings are not forever and will eventually fail in 20-60 years. Contractors love plastic, not because it's better or cheaper but because it takes a fraction of the time to install and requires far less skill.
@oguzhan0015 жыл бұрын
Totally agree. With a borrowed pvc pipe heater, I was able to install a new piping system that stretched from the main source & to the my house. Tho, I got professional help for rest of piping work lol.
@volvo095 жыл бұрын
Faster and easier wins. But for my stuff I still solder. I hope I'm wrong, but if o rings fail in vehicles and devices after years of heat cycles, I can imagine the same thing happening here in 20 - 40 years. The crimp copper fittings are even being used in AC installs. I'll stick to solder, and require it if I get work done that I don't DIY. My brother got a new boiler installed in his house and they used about 50 to 60 of those viega copper crimp fittings, sorta defeats the purpose of copper to me.
@bgregg555 жыл бұрын
Well...copper freezes & splits. copper sourced from china often has contamination which corrodes & springs leaks. copper is expensive. we never use copper anymore.
@johnpossum5565 жыл бұрын
Around here copper is code for all commercial and rental properties. IE: The government says its better.
@Conservator.5 жыл бұрын
volvo09 Lol I read AC as Alternating Current in stead of air conditioning.
@mickeyfilmer55515 жыл бұрын
As a retired marine engineer, I have always sworn by copper pipe, but seeing this has given me food for thought. Very interesting video (as always). Keep up the good works.
@idiotstupid59045 жыл бұрын
it's very easy to use and there are different makes, but have used the jg speedfit stuff, (available at screwfix in the uk) it is as simple as, cut pipe, use insert, insert into joint, that's it , only thing i have against it, it's more plastic in the world also am a bit against using it for mains/drinking water but that's just me
@HighestRank5 жыл бұрын
As a sailor you without question have sworn, though the presence of copper pipe was only coincidentally “by” only due to frequency of curses in a large variety of locales. That’s the engineering part: a rule of thumb everywhere there’s water.
@HighestRank5 жыл бұрын
idiot stupid our Sharkbite system is also questionable for water, made of a supposedly leadfree brass alloy, but who really knows?
@bigrattila55 жыл бұрын
I have been using those style of push-to-connect for about 10 years now and haven't had any issue. I have been doing FIRST FRC Robotics for 10 years now and the Pneumatics uses those connects for 1/4" polyurethane tubes. The fittings we use are Parker W68PLP-4-2, 364PLP-4, and W369PLP-4-2 and the pressure reaches 125 psi. I have never seen one fail and we reuse these fittings every year. Needless to say, they are excellent push-to-connect that is easy to install and removal is just as easy.
@christastic1005 жыл бұрын
Really interesting to see inside the auto air vent . Fitted them but never tried to open it up. Believe the insert without external o rings are Used when plastic is used on brass/copper compression fittings with an olive . Used lots of John Guest pipe and fittings and found it good. Nice to use copper when on show though.
@AndrewWorkshop4 жыл бұрын
I always crimp my pex connections but this system looks great if you only have a few connections to make. In Canada Sharkbite fittings are the most popular. Always wondered how those auto vents worked, I can hear them vent if air gets into the system, I have them at the highest point in house. The only time my system seems to vent is between pressure changes. Great video. Also there are a few types of pex pipe, the standard stuff lets a small amount of oxygen into the lines, not a big deal for potable water use. Then there are types used for heating that do not let oxygen get into the heating loop, using the standard stuff in a heating system could cause the boiler guts to corrode over time.
@bondubasher5 жыл бұрын
Had the very same in my house since around 2003 and haven't had an issue with it yet. I think if you observe the points you already made about protection of the O rings (no burrs etc) then it's fairly robust system. Great vids Clive, keep em coming...
@RobertBeck-pp2ru Жыл бұрын
It is when the float drops that the valve opens. It will drop if air is trapped at the top of the cup, displacing the water. As the air is expelled, the cup fully fills with water again and the float will rise, closing off the air escape route. No more knock in the heat register. Yea!! Also, real plumbers use copper pipe and lead free solder to build water lines. Love this channel!
@fillg5 жыл бұрын
Thanks for the air vent explanation. I've always wondered how they could let the air out but not spray water constantly.
@xxwookey2 жыл бұрын
I've been using plastic plumbing since 1994. Hep2O in the early days and mostly JG speedfit in recent times as it's more widely available. Not had any issues with failures. I do still like a bit of copper sometimes, e.g. for very high temperature stuff like solar thermal, but plastic is so much easier most of the time. It's funny to see someone in 2019 who's never tried it before.
@karthik_raju3 жыл бұрын
10:36 in case of a clogged up valve one could take the top nipple screw cap off and push down on the valve by sticking a thin screwdriver through the bleeder hole. That way you have a quick fix with out having to depressurize the whole system
@trevorsmith18595 жыл бұрын
I did my central heating system using Hep2o plastic pipe fittings about three years ago and have had no problems and it is safe to use anti corrosion chemicals in the water. The inner blue layer in the pipe is as you say an air barrier.
@twocvbloke5 жыл бұрын
That vent kind of reminds me in a way of a carburettor bowl, but working to let the air out rather than the fuel in...
@OZCamperTravels5 жыл бұрын
...or a toilet cistern backwards?
@wobblysauce5 жыл бұрын
both use the same principle.
@stevecummins3243 жыл бұрын
Very like a bucket steam condensate trap still in use from early 1800s. Except they keep gas in and let liquid out. Just different lever arrangement for float and valve
@charlesburow81203 жыл бұрын
Just thinking the same thing.
@Robert_Wolf5 жыл бұрын
Ive used poly plum for the past 10 years. completely rebuilt the water system in my old bungalow. central heating, main the lot. very reliable. easy to do. I used copper to present to the radiators and poly plum feeding them. Good good stuff when used properly
@HighestRank5 жыл бұрын
Robert Wolf main the oars.
@Brusselpicker5 жыл бұрын
Worked in the business for years, maintaining many MOD sites, copper all the way. In my experience, plastic compression fitting will give in at random times, as an example of 500 new accommodation spaces built , there were at least 100 failures of push fits within the first year, the rate of failure of soldered copper? 0, none. Plastic is a cheap, easy and less skilful way of piping up, once you use a push fit and remove the o ring from the copper it's useless and will inevitably fail.
@Brusselpicker5 жыл бұрын
Just to add, the push fittings were always used by outside contractors to keep their bids cheap as they were not required to maintain the new buildings, they don't care about the long term. Us maintenance guys always used copper knowing we wouldn't need to "re re-fix" a repair. We spent literally thousands of man hours "maintaining" these new systems to get them to work properly. If I had any choice I would always start with soldered copper, followed by compression fit copper, any poly pipe with push fit would be the last choice in my own personal property.
@Brusselpicker5 жыл бұрын
Ferrules are mandatory when installing poly pipe on any MOD site, just sayin. You can avoid pinholes by cleaning flux off and actually bothering to flush pipework out only no one seems to want to pay for that so you get pinholes. Only outlets that require flushing are "little use" outlets and those need to be flushed whether they are copper or not according to l8 regulations. Oh and water fountains can't be used anyway, l8 legislation again. Oh and the 70s you say, how modern, part of my work includes a 12th century priory, the most modern buildings, apart from refurbishment of new build (12 accommodation blocks built by the lowest bidder that started cracking up within a year) were the sixties, with quite a large number dating back to WW2 or further, we never had or have as much trouble with the copper as with poly, just never have. The poly though lol, one split joint caused £100,000 worth of damage and resulted in three floors of the building that was 18 months old being stripped back to bare frame and being rebuilt.
@NvTwist3 жыл бұрын
Genius solution. The pressure differential will hold the two surfaces together sealing the system, as air accumulates inside the float drops down its tilting the valve surface enough so air begins escaping & closes again as the float rises. It takes far less effort to tilt the two apart than it would to pull the two surfaces apart squarely. Great design.
@crackedemerald49305 жыл бұрын
Electricity, Hidraulics, same thing, both involve angry magical beings, angry pixies and unyielding nymphs respectively
@teamdrummond6915 Жыл бұрын
Good one!
@martinnewbery30324 жыл бұрын
Go for it Clive. We've had had problems with old copper pin hole leeks. Called plumber in to replace all incoming mains water pipe work. Have now got lots of pipe and fittings as seen in video. good job!!! Keep the vids. coming Clive.
@bigclivedotcom4 жыл бұрын
I ended up replacing the main incoming cold water line with plastic.
@lawsonjones22855 жыл бұрын
It's also worth noting the air valve will allow air to be drawn into the system when it's being drained down and helps avoid vacuum locks
@thomasbland64285 жыл бұрын
lawson jones I’ve known installations that had a connection where they would connect a compressed air source to blow out any remaining liquid when draining the system. These were systems in cabins that were only used infrequently during the freezing season so were drained to prevent pipe bursts. Having a way to block air venting was important to force the air to exit where desired.
@millomweb5 жыл бұрын
@@thomasbland6428 When I decommissioned my old heating system, I sucked the water out with a wet n dry vacuum cleaner.
@Stigstigster5 жыл бұрын
I run a training workshop for apprentice plumbers and whilst we use a lot of copper we also do some of the work with pushfit and plastic. I have long ago settled on John Guest Speedfit for a couple of reasons. They are demountable without tools and reusable, which saves us money. Just as importantly they are incredibly reliable. I have the same set of JG fittings on our pressure tester all year and despite being mounted, pressure tested often to 10 atmospheres and then demounted numerous times a day every day, I have never had one of these fail. I always use copper and soldered end feed when given the choice but where plastic is specified I use JG because of these experiences with the product. I have a lot of confidence in them. I have no relationship with the company other than I use their products. Highly recommended id plastic plumbing is what you need.
@bigclivedotcom5 жыл бұрын
That's reassuring to hear.
@maesto5 жыл бұрын
Here in germany pex is basically the new standard. Though in the non diy market usually its pressed fittings which are smaller and thought of more reliable. Works with Copper as well.
@Morbazan1255 жыл бұрын
Worked with this exact type of pipe and fittings and can say from experience it does not like ice at all, it’s used a lot on static caravans and even with insulation can still burst the pipe or blow the fittings apart, also had many occasions where the pipe had blown out of the fittings even though the water pressure wasn’t too high.
@hiredgun71865 жыл бұрын
we use a system like this , french made, transair piping for compressed air , its extruded aluminum and has a WP of 236 psi but tested to twice that
@MichaelOfRohan3 жыл бұрын
Hey thats pretty good. Id imagine oilers really work wall across those aluminum lines
@Mr.Eldric5 жыл бұрын
Ive used the pushfit stuff. Its fine as long as pushed in properly and make sure the cut end has no sharp edges or the o ring is pushed out of place. I used it when i worked in property maintenance. It was ‘hep’ but is just the same as the b&q stuff. Quick and easy
@RandomInternetDog5 жыл бұрын
We used air eliminators on pumps running liquids with high amounts of dissolved gas. Different design, basically just a metal ball that floats. Constant PITA.
@davidb52555 жыл бұрын
I've used plastic piping in both my parents house and my own with great success. I've used it on HW and CH in both 15 and 22mm, the only thing you have to use copper for in CH is the first metre from the boiler. It's great stuff because it's so easy to make connections in confined spaces, the pipe can be bent so you can feed it through tight gaps such as joists or around obsticles. It's also impact resistant, won't freeze and split like copper and has better thermal insulation even without lagging. I've mostly used the Hepworth Hep2O brand which I have found to be very robust, professional and reliable. Their original fittings had the grab ring after the O-ring seal so there was no danger of scratches from the grab ring compromising the seal. This fittings could be taken apart but you had to unscrew them. Their new stuff is more like the Speedfit with the grab ring before the O-ring. That said I have demounted and remade without any issues. The Hep2O fittings need a plastic tool to press a pair of recessed pins in to release the grab ring which is perminently trapped in the fitting so no issues with it dropping out like you had. Also no danger of accidentally releasing the grab ring. That was actually the only time I've had a failure (well my dad actually), he thinks he may have knocked the Speedfit release ring and it came apart. The pipe as you said is multi layered with the dark layer acting as a gas barrier for CH systems. It's great stuff, go for it, you'll love it. That said I also quite like doing copper solder joints and bending, and managed to do some really quite impressive multiple bends, in different axes, on some 28mm gravity feed piping.
@PatrickLeeUS5 жыл бұрын
Have faith in the speed fit, but what I didn't tell you when I recommended it earlier is that you absolutely must install a water hammer arrestor in the system. Otherwise the water hammer over the years will have a tendency to overly stress the o rings causing failure.
@bigclivedotcom5 жыл бұрын
I was wondering what effect water hammer would have. Especially with a washing machine that uses solenoid valves.
@IncertusetNescio5 жыл бұрын
@@bigclivedotcom Machinery like that makes me wonder why the heck they don't have a built-in water hammer arrestor/preventing device built in knowing full well that it's a device that does it. Doubly so knowing how cost optimized some of the other parts in there are. Or heck, just use a slower closing valve. Maybe use a pressure bypass valve for pressure spikes when the valve closes that lets enough water through into the machine to clip the spike down below plumbing-stressing levels.
@l3p35 жыл бұрын
I did not know that problem exists. I am used to open and close faucets in a rapid manner to save time. If you work with power transistors, a quick switch time is a good thing. But the pipework of where I live is metal, I think.
@michaelfisher96715 жыл бұрын
Isn’t water hammer caused at least in part by the lack of give in water and copper? If so and if as BC says this piping has some ability to stretch (which is why it can survive freezing) then it may not hammer.
@PatrickLeeUS5 жыл бұрын
@@michaelfisher9671 unfortunately it still hammers, albeit to a lesser extent. However, it still has enough force to blow an o ring.
@AlexanderWright15 жыл бұрын
I've extensively used push fit fittings in my house. Mostly JG speedfit, but other makes as well. When you are placing pipes under the floor, it is much more convenient than copper when threading through holes in joists. The push fit fittings also remove the problem of setting fire to your house when soldering in confined spaces. I've made joints in places that I've not been able to see to make the joint.
@HighestRank5 жыл бұрын
Alexander Wright I’ve soldered joints in a wall where both the joists and gypsum board turned black due to indirect heat from the torch flame. Just put some flux on the surrounding surfaces in the worst cases. Smokes some but it won’t burn.
@joedugas94625 жыл бұрын
Plastic pipe is cross-linked poly-ethylene. Proper ways of connecting it is using "crimp" style fittings or expanding ring fittings (Wirsbo) or "quick and easy" method. Push fit fittings such as "shark-bite" or O-ring fittings should be considered temporary methods. PEX piping will out-last copper if using proper joining methods. Copper is not better.
@ChurchOfTheHolyMho5 жыл бұрын
After 2 different plumbers used PEX (and one used a SharkBite connector) - I became a fan. Note: My parents had some PEX installed, and theirs had an unpleasant taste. My PEX does not. Seems to be easier to use than PVC/CPVC.
@grrarg93195 жыл бұрын
Unless you're talking about its ability to kill off MRSA, in which case COPPER FTW!! :D
@ethanpowell81635 жыл бұрын
It will also lower water pressure, due to friction in the joints, due to the ID of the joint being significantly small... I feel bad for the lady we might have to do a repipe for. Her water pressure is so low the valve on her kitchen faucet doesn't want to stay open, due to it using pressure to stay open.
@CrimeVid5 жыл бұрын
Joe Dugas Hollyhocks ! these fittings last extremely well, just use the mf’s own fittings and you’re good, I have never seen “crimp”style fittings in the UK.
@ursodermatt88095 жыл бұрын
those "plasticky plumbing things" have only been around for a limited time. so you cannot make a statement that they are outlasting copper.
@alexpmK35 жыл бұрын
I have used this plastic push fit stuff quite a bit. I had my doubts for sure at first, but after a few tests i was pleasantly surprised that it works !!
@HighestRank5 жыл бұрын
Alexpmgr8 K3 after only three tries, it no longer blew itself off the ends of the pipe.
@Moshealthtips5 жыл бұрын
but i like the schematics.its the most valuable thing your channel offers, i look forward to learning from them
@LordClunk5 жыл бұрын
I used to work for a company called Wavin. We did a push fit system called Hep2o. It was one of our most popular systems, so I guess it works. I know Wavin testing was quite thorough. When I first started there I was quite surprised how much plumbing supplies went out. 60 to 70 trucks a day when I left. Makes you realise how many houses are being built every day.
@alidavemason44172 жыл бұрын
Great video as always Clive. Did you know that on the plastic pipe fitting, if you continue to unscrew it past the the resistance point the whole thing disassembles. This makes it easier to remove the pipe insert instead of using pliers. Cheers Dave
@victorrowley74945 жыл бұрын
Hi Clive, I was watching your video on bottle air vents, and a couple of things came to mind. Like you, I've always sworn by copper as compared to the new untested plastic pipes. But two winters ago, they had some prolonged periods of below freezing weather in wales. And as my son and his wife have a wooden holiday chalet in wales, when they made their first visit after the winter, and they turned the water back on, there were at least ten different bursts in the pipework. But when I went with them to do the repairs, we found that half of the chalet (I'm guessing it must have been an extension built on the original), was piped for both hot and cold water with plastic pipe of the type you were describing. And whereas the sections of copper in all other areas of the chalet have ruptured, there wasn't one leak, nor forced joint, nor split in any of the plastic system. So maybe, plastic is the way to go. And one more thing, if I'm not boring you; your pinholes in your copper pipe. A thought that struck me, was that I've always cleaned the ends of the pipes with wire-wool. I assume you're familiar with this stuff. And whereas it doesn't leave significant grooves or scoring, tiny little fragments of the iron strands can and do flake off. Could those pin-holes have been caused by such little fragments floating down the pipe and then settling? And over time, some kind of dissimilar metal electrolytic reaction has eaten its way through. Anyway, these are just my thoughts, and I thought it was about time I thanked you for your instructional videos; keep up the good work.
@juliogonzo27185 жыл бұрын
I used to live in an apartment with underground parking. There was a hose bib in my stall, I washed my car a few times before I realized the water changed to hot in the winter. Oopse :)
@throttlebottle59065 жыл бұрын
lmao, now that is funny....
@Tryin2FlyII5 жыл бұрын
Hi Clive interesting video -Here in the US we have something very similar to those fittings they are called "Shark Bites" (I think) and like you I am from the "old" school copper era (I am 55) and I had to do some plumbing repair awhile ago when I seen them and thought the same thing as you did "no way --this will leak like a sieve" but I tried them anyway and was blown away how easy and simple they were to install and use AND what would have easily taken me a 1/2 day to re-plumb my bathroom using copper- having to solder and make sure the length is spot on, clean and every little thing else that has to be perfect when using copper so it doesn't leak was finished just over an hours time! I could not believe it' That was 5yrs ago and still not one problem with that type of hook up I wont use anything else now if I have plumbing work to do it is just that easy and simple to use for BOTH Copper AND Plastic pipe
@terry9876545 жыл бұрын
the thing with plastic pipes is what will it be like in 20 years will i have to replace it again? copper might be harder to install but at least it is tried and tested so you know it will out last us
@macemoneta5 жыл бұрын
I had a plastic water main supply. It lasted 40 years, and then cracked under the front lawn. The plumber said they don't use that anymore, and replaced it with a single length (65 feet) of copper from a large diameter coil, pulling it through from the basement.
@simontay48515 жыл бұрын
Did you have water gushing out of the lawn.
@manolisgledsodakis8735 жыл бұрын
But the whole point is that Clive's copper pipe did NOT last - it was perforated. Here in Greece we have used plastic pipe since the time of the Romans. (Well, almost.)
@macemoneta5 жыл бұрын
@@simontay4851 Yes, that was our clue. 😂
@macemoneta5 жыл бұрын
@@manolisgledsodakis873 That was likely an improperly installed /damaged pipe. Copper also has the advantage of being antimicrobial, but it is more expensive than plastic.
@apollorobb5 жыл бұрын
PEX =cross linked polyethylene We use it exclusively in the US for new home manufacture. Its been around a long time. Ours uses mainly brass barb fittings and a ring that crimps onto the tube to hold it.Those push in fittings are commonly known as Shark bite fittings .
@LaylaSpellwind5 жыл бұрын
Not sure why I watch this. Perhaps it's just nice to hear a fellow Scotsman talk. Thanks for the video, Clive.
@HomelabExtreme5 жыл бұрын
This fitting system reminds me of pneumatic fittings, they work the same way (except for the twisting part), and they don't use any o-rings just metal fittings and 6mm pvc pipe, and they are usually spec'ed for 8-20bar (115-290 psi) and doesn't leak any air. They exploit the pressure to hold the pipe in place, the higher the pressure, the harder the fittings grip the pvc pipe. I have tested these pneumatic fittings up to 50 bar (725 psi) and they kept working (although a little scary at these pressures) And they are super easy to work with, just snip the pipe with scissors and plug them into the fittings. and disassembly is just as easy, very nice system! Wouldn't doubt the reliability for low pressure water when they work so reliably for high pressure air.
@QlueDuPlessis5 жыл бұрын
Hmmm. We got a plastic piping called "polycopper". It's a pinkish/red direct replacement for copper. It also uses the same brass ring ferrules.
@johnpossum5565 жыл бұрын
They call it copper because they know copper is better and this way they can mark up the plastic and charge copper-like prices for it.
@ColtaineCrows5 жыл бұрын
You can use the ferrule system for plastic too, just use a brass or copper insert in the pipe. I don't generally recommend that solution, but if done properly it works alright.
@happycola015 жыл бұрын
I’m currently in training to be a Plumber in Germany, the Company I’m working in uses these plastic pipes quite frequently and rarely has problems with them leaking. However you are required to use the versions of fitting that you press shut and not the ones you have when you install them in places where you don’t have access to them later. We use the ones you have primarily for temporary installations but they are quite well suited for high pressures (we testes them up to 12 atmospheres and they held tight.
@philliplopez87455 жыл бұрын
The popular American brand is " shark bite " expensive but worth while for repair work or joining dissimilar materials .
@carpespasm5 жыл бұрын
And they're not technically rated for air pressure, but I've seen them successfully hold a 190PSI/13bar for years just dandy.
@HighestRank5 жыл бұрын
Sharkbite* worthwhile *
@philliplopez87455 жыл бұрын
@@HighestRank auto correct
@Smidge2045 жыл бұрын
Any air that gathers in the chamber will be at the same pressure as the water, and since the float doesn't weigh much, the hinge point is located to give maximum leverage to open the port. Air will leak through the tiniest hole so it doesn't need much anyway. The barrier PEX (which stands for PolyEthylene cross-linked) is for gas diffusion. The plastic is actually permeable to oxygen, so to keep oxygen from getting in and dissolving in the water (which promotes corrosion) they add the barrier layer which is not permeable but also not as strong. Those push fittings are amazing, by the way. Almost magic. I've used them in my own home and one repair has been in service for several years now on the HOT water pipe with no issues!
@rimmersbryggeri5 жыл бұрын
Your old pipe was cavitated beause of shoddy installation. When you don't deburr the ends properly that can happen because of turbulence caused by the burrs.
@ferrumignis5 жыл бұрын
Could you describe what kind shoddy installation can cause random pin holes through corrosion? How would cavitation occur in the middle of a run of pipe?
@rimmersbryggeri5 жыл бұрын
@@ferrumignis There are videos here on youtube explaining it much better than I could.
@rimmersbryggeri5 жыл бұрын
@@ferrumignis I think it's about the burrs creating condensation nuclei and when the bubbles burst they cause a sonic boom which create microscopic cavities in the pipe which are then eroded by the flow. Does that sound sufficiently like a 12yearold explaining something the heard about on lunch break?
@Mark1024MAK5 жыл бұрын
Yes Clive. I’ve used Speedfit plastic fittings and pipe to add an extra valve to a heating system (the original suffered from gravity self circulation so even when the heating was not on, the radiators on the first floor would still get hot). This was after we had two extra radiators installed by plumbers and I saw them use the Speedfit plastic fittings and pipes (they were not the cause of the circulation problem, that existed beforehand). They loved this Speedfit system. So much quicker and less messing about. They did use copper pipe where the pipes were exposed as they ran along the skirting boards. All this was over 20 years ago now. Have since moved house (a much newer house), and although no major problems, have had to tighten some of the compression fittings due to small leakages (all copper pipework as far as I can see). But I keep some Speedfit plastic fittings, the straight joins, in case I ever need to carry out a quick repair.
@JL-rx6hl5 жыл бұрын
Hi Clive, I have used pushfit for years and never had a problem with it. The other good thing about plastic pipes is, as they come in coils you can have a long run with no joins and it can be run through joists etc just like a cable(ok a thick cable)
@robinwells88795 жыл бұрын
I think it is fine and I used it on my current house but in retrospect I would only use it for long unjointed underfloor runs because I did have issues with some connectors whereas I never had issues with past copper systems I have installed. Brilliant for quick emergency repairs. For sheer craft beauty though really it is hard to beat well executed copper system. I can also confirm that I have encountered copper pipe with linear extrusion contamination defects that have then leaked very soon after fitting
@Orxenhorf5 жыл бұрын
Those things last until the o-ring inside degrades and wears out. So, you have no idea how long they'll last, because you have no idea if the manufacturer decided to cut expenses and use cheaper material, or they used good stuff that would last as long as the pipes.
@artyomhunter3105 жыл бұрын
You can be sure that it was made with quality materials if it’s a WRATS approved product as they are the regulatory body that tests the product and if it meets their standards for a product to be sold with the WRATS label on it. Most manufacturers exprcssely recommend you use WRATS approved fittings on there product because of the guaranteed quality of the product. The O-rings will be fine for a long time if used on new plumbing but not as long on old plumbing. it will depend upon the amount of crap that running around the system but even in really dirty old systems the O-rings should outlast your emersion heater and hot water storage cylinders by many years. They should last longer on the cold water pipes as that water isn’t left to stagnate for long as it’s always used. They will also last longer in areas with softer water as a pose to in areas with hard water. The lime scale tends to build up around the O-rings and degrade them over time. The WRATS products do cost more than non approved products but your paying for the quality and longevity of the product. In my own opinion I think that the whole push fit plastic plumbing system is a better system than the copper one even the push fit copper systems. Even if the O-ring did perish or become unusable I do believe you can buy replacement O-rings instead of replacing the fitting.
@arcadeuk5 жыл бұрын
You get a 50 year warranty on the JG Speedfit fittings Clive is showing in this video.
@ferrumignis5 жыл бұрын
That's the main reason I don't really trust the plastic piping. The pipe itself seems very reliable, but o-ring seals invariably degrade over time.
@blower15 жыл бұрын
@@arcadeuk Lol - might as well be a 100,000 year warranty. Come 50 years time you think that company will still be around and not been bought out and changed name half a dozen times? A warranty much beyond 10 years on anything don't mean jack shit.
@arcadeuk5 жыл бұрын
@@blower1 Why so much unwarranted hostility to JG Speedfit? They (John Guest, a British company) have already been around for nearly 60 years. They've managed to avoid changing their name half a dozen times so far .......
@dglcomputers14985 жыл бұрын
We use connectors like this for the caravans at work, me being adept at unscrewing the connectors when I need a water hook up (generally for the jet wash) But I will categorically say that they most definitely do split when they freeze, something that we found out last year when we had a couple of sudden cold snaps, caused absolute havoc!
@isoguy.5 жыл бұрын
Glad to see you opted for the GF kitemarked version. Beware of chinese clones, short mouldings, poor o rings and doggy steel clips that rust tend to make them fail often. My Dad did his bathroom using cheap chinese clones, they failed after 3 months, and completely flooded his house overnight. He had to rip up all the newly laid floors upstairs, completely redecorate the whole house while our family moved out for 6 weeks. The insurance refused to pay out as the fittings were not up to code and were not fitted by a professional plumber. For the sake of using kitemarked parts he paid out £1000s and then had to have all the piping and fittings replaced. Beware of Chinese clones.
@bigclivedotcom5 жыл бұрын
I'd never use a cheap copy in a situation like this.
@quattrohead5 жыл бұрын
Clive, your copper pipe developed pin holes because of iron in the water. We use PEX and PVC pipes here in the USA now. Pex uses either "Sharkbite" fittings similar to your's or Brass or plastic couplers with stainless steel crimp rings. PVC is usually glued. I had used PEX and sharkbite fittings to run a pipe out to the garden with a tap on the end. Unfortunately I forgot to drain the pipe for the winter and the water froze. All it did was push the PEX out of the sharkbite and left deep scores on the pipe LOL. All I did was cut an inch off the pipe and pushed it back in.
@bodinski1005 жыл бұрын
use plastic everyday, maybe 2 leaks in last 10 years...make sure pipe is clipped to joists etc well
@rogertycholiz22183 жыл бұрын
Bod Cole - Installed ten compression fitting shutoffs on copper pipe for 40 years with no leaks.
@willcaro10385 жыл бұрын
Hi Clive, I first used plastic (Bartol Acorn) around 25 years ago. And it's even better now. I wouldn't pull either plastic or copper out of a fitting with the intention of putting the same pipe end and insert back. If you need to disconnect you can unscrew the 'nut' completely to take out pipe. and all fittings as one without rink of damaging pipe and o rings on the grab ring. Hope this is helpful. Great videos, Will
@michaelpage83375 жыл бұрын
We used push fit fittings for compressed air at the factory and found them reliable
@andyxox41682 жыл бұрын
Well they’re normally rated at 6 bar so you’re pushing your luck … and a failure on a large compressed air system can have nasty consequences!
@eideticex5 жыл бұрын
Have used a bit of each type of pipe and fitting. I prefer those o-ring push fit connectors over crimped, glued, soldered or compression fit joints. The reason comes down to how the joint is formed and supported. The o-rings help mechanically isolate the intentionally damaged section of pipe from the rest of the system. The main thing to watch out for with PEX and PVC however is to make sure that pipe is anchored to the building with the appropriate anchors for the type your using. Water hammer becomes a more significant issue with plastic pipes than copper but is easy to mitigate with a consistent anchoring system.
@davet67455 жыл бұрын
PEX means polyethylene cross-linked
@veleriphon2 жыл бұрын
And it's fantastic.
@ThingsWhichArentWork5 жыл бұрын
I've been using PEX tubiing and JG speedfit connectors for the compressed air setup in my shed for over a decade. 8 bar pressure and there's never been a leak. The central heating system in my house is the same, but at much lower pressure. It's good stuff... just a shame that it's not a pretty as copper. Cheers!!
@HighestRank5 жыл бұрын
Jim Conner all you need is a mouse.🛡
@crimsonhalo135 жыл бұрын
♫ Zu klein, Zu groß, Every size will fit this hose, Ram it in, Tighten up, Turn it out, Bratwurst im dein sauerkraut!♫ *sets fire to pyrotechnic angel wings* ... see? Rammstein songs are half plumbing.
@WineScrounger5 жыл бұрын
Crimson Halo 🤣
@boblewis55583 жыл бұрын
And there I thought Rammstein music was just for the USAF airbase!?
@christopherguy12175 жыл бұрын
I used PEX pipes with brass inserts and copper crimp rings to fit it together. After 20 years I haven't had any problems and my well water has lots of impurities. The only downside is the crimping tool is $50 or more and you can't use it in tight places. The upside is you can run one uninterrupted line from a manifold at the water supply to each fitting and never worry about leaks in the walls and as a bonus you don't get pressure drops from water to other fittings such as washer, toilet, etc.
@scottyoung33545 жыл бұрын
Bee using the JG speedfit for years now, never had a problem and found it more reliable than copper.
@responderman5 жыл бұрын
As an emergency plumber I rely on these fittings quite a lot to get me out of problems when a leak occurs. In the past that used to take me awhile even with compression fittings to get everything lined up and prepared but with these fittings I can replace the section of pipe within 2 or 3 minutes. Like yourself it took me a while to get to trust them but once you do you never look back. Incidentally it's worth mentioning that the only failed fitting was when there wasn't enough space to push the pipes together so I pulled the pipe towards me to create the gap, however not pushing the fitting together straight pushed out the O ring. They are rather ugly and I tend to use them out of sight. You can also get a similar fitting in copper, but they will not come apart.
@thomasharper90875 жыл бұрын
yes but plastic pipe connectors are much MUCH bigger compared to soldered copper joints
@gelu885 жыл бұрын
The ones he's using is massive. I prefer the "sharkbite" brand ones which are quite a bit more compact. Expensive though.
@edcooper23965 жыл бұрын
and a lot more restrictive with those inserts installed!
@simontay48515 жыл бұрын
And any copper off-cuts are fully recyclable. plastic pipe probably isn't. Hot water might soften/melt plastic pipe. Soldered copper looks nicer. Lots of advantages to copper.
@ComandanteJ5 жыл бұрын
@@simontay4851 Almost all plastics are very easily recyclable. Piping plastics are not your "cheap chinese toy" variety, heat is not a problem, and if REALLY hot water is expected, there are plastic pipes that are engineered to resist temperatures well over 100 ºC . Soldered copper does looks nicer... but who cares? It's inside a freaking wall. The only advantages of copper are that it tends to be cheaper overall because good plastic joints are expensive, and space, copper is a lot more compact.
@donkmeister5 жыл бұрын
@@simontay4851 On the hot water aspect, boiler installations require copper for the first metre away from the boiler for this very reason - who wants a melty-saggy pipe? Copper also requires fewer clips to avoid it sagging and straining against the fittings. Like you I prefer soldered end-feed copper, plastic O-ring based systems (I favour Hep2O if I must use one) are really quick and easy though, especially for amateurs. I don't think plastic is approved for domestic gas either - I know my gas main is plastic right up to the boundary line, then iron to the meter, then soldered copper from the meter to the appliances.
@countzero11365 жыл бұрын
I don't get to do much plumbing other than the occasional DIY job around the house, but I have to say that I've found plastic pipe and fittings to be extremely reliable. PEX pipe in particular is extremely good and resistant to almost everything you can throw at it. The only downside is stuff like earth bonding when you have a mix of plastic and copper pipes running around
@koffibanan30995 жыл бұрын
If you can, you should take a look at the spirotech deaerator that are getting very common here in Belgium. They seem a bit more advanced and mysterious. I also watch the ultimate handyman, like his accent! :)
@ultimatehandyman5 жыл бұрын
You either love, or hate the accent- I have plenty of haters! Thanks for watching the videos and commenting ;-)
@koffibanan30995 жыл бұрын
@@ultimatehandyman Haha! The accent is naturally not the only reason I watch your informative, honest and well put together videos :) I do it to impress friend and enemy with 'my' knowledge about tools and DIY'ing :D Finished quite a few projects that have benefitted greatly from your advice. So thanks a lot for all your effort!!
@ultimatehandyman5 жыл бұрын
I'm glad that the videos help ;-) When I get a comment from someone like you, it always reassures me that there are good people on KZbin 👍 Thanks again for watching, and commenting 😉
@Brian-cr6rb5 жыл бұрын
I love those things!
@treed59535 жыл бұрын
@@ultimatehandyman That tears it, now I'm intrigued about the accent
@mavos12115 жыл бұрын
Clive I have used speedfit for many years with no problems other than my own stupidity! ( forgetting to put the insert in ) I have test rig equipment that I have taken Apart and then re jigged different configurations many many times and it’s sealed up tight every time. I like copper but it’s hard to ignore and very convenient.
@HighestRank5 жыл бұрын
mavos1211 copper hard to ignore, well that’s only if you’re running thieves’ blood in your veins.
@lostjohnny90005 жыл бұрын
Is there a medical version to prevent liquid seepage?
@bulwinkle5 жыл бұрын
Yes, it is called an elastic band.
@lostjohnny90005 жыл бұрын
@@bulwinkle Thanks. Do I make it into a ball before inserting it?
@bulwinkle5 жыл бұрын
@@lostjohnny9000 or loop it tightly around the outside.
@lostjohnny90005 жыл бұрын
@@bulwinkle My friend says his bum hole is an 'inny' not an 'outy'.
@bulwinkle5 жыл бұрын
@@lostjohnny9000 ah!
@sooty6555 жыл бұрын
JGSpeedfit and similar systems have been used for heating and domestic water on narrowboats for many years - work well and don't give any problems
@HighestRank5 жыл бұрын
sooty655 vs. one mousey boi.
@ColtaineCrows5 жыл бұрын
In Norway we use "pipe in pipe" systems now. Basically a corrugated pipe is installed with a plastic water line inside it going back to a main water cabinet. Essentially the plumbing industry is doing the same thing as the electricians here. So if you have a leak it'll leak back to the water cabinet which should be installed in a water safe room and spill out on the floor there instead of all over your house. That is if your leak is in the walls. Anything on the outside is still liable to cause damage, but that's why you're also required to install water sensors and an electric shut off valve system under the kitchen furniture etc. Just like you're required to install a temperature sensor shut off thingy over the stove (Which sucks btw, never work like they should and are pointless for induction stove tops IMO!) www.johnguest.com/speedfit/product/pipe/pipe-in-pipe/ It's a nice system IMO. It looks like the pipe you're showing here is one half of the John Guest pipe-in-pipe system. EDIT: Basically it means you have one run of water to the kitchen faucet, one run to the dishwasher, one run to the toilet, one run to the shower and so on. So it does require some more pipes to be installed, but it's really good for preventing water damage.
@edcooper23965 жыл бұрын
How do you ensure you always have a clear and continuous fall of the pipes to the water cabinet, often they have to be run horizontally over quite long distances. Most homes in the UK have central heating with radiators, there's no way you're going to run a flow and return to every radiator?
@sigurdhovden49615 жыл бұрын
@@edcooper2396 the outer pipe is sealed at the end so it will fill until the water returns to the cabinet and heating and cooling is sadly exempt from the requirement of the replacement and "water damage safe" rules
@HighestRank5 жыл бұрын
Sounds for a great place to get a drink- for roaches.
@TurboTel685 жыл бұрын
Many many years ago one of the manufacturers of plastic plumbing products had a go at producing a hot water cylinder to replace the copper ones, anyway after a while these tanks became wet on the outside, the manufacturers claimed it was condensation even though they were correctly lagged. It later became apparent after some dramatic failures that the plastic was actually crazing and leaking! For me, plastic pipe has its place, I like it for long continuous runs under floors avoiding the need for joins, also unlike copper pipe it doesn’t rot when it contact with a concrete floor, although I’m still not keen in seeing it on hot water and heating systems as I have flashbacks of those hot water cylinders!
@DoRC5 жыл бұрын
The technical term for that olive is a ferrule.
@TheChipmunk20085 жыл бұрын
No, olive is the correct technical term on this side of the atlantic.
@DoRC5 жыл бұрын
@@TheChipmunk2008 oh. I've heard ppl in the states call it an olive as well. Didn't know it was the official term there.
@TheChipmunk20085 жыл бұрын
@@DoRC indeed, two countries separated by a common language is often scarily true. It's even worse with many other words
@davidgreen50995 жыл бұрын
@@TheChipmunk2008 olive
@tommyymmottommy5 жыл бұрын
Use it daily in my line of work (plumber). But not the quick fittings, we use the multi layer pipes but with press fittings pressed with hydraulic press machine.
@RIXRADvidz5 жыл бұрын
Expanding Horizons!! non-electrical tear-downs. the mind boggles, the opportunities myriad, a whole new Universe is opening up. it was the siphon pump on the bubble blower wasn't it. yeah, me too.
@antonina1115 жыл бұрын
For installation in my own home I'd recommend stainless steel pipe, more expensive yes but if you're going to keep living in the house for +20 years definitely worth it (or maybe aluminum core PE-X pipe with a compression sleeve system (like from the company "Rehau")). Stainless steel also being a nice selling point if you do want to sell the house. To the bottle air vent, the cap on it is supposed to be screwed shut at all times and only meant to be unscrewed when you want to vent the pipe. They will leak eventually and depending on where it's installed will cause damage by the time you notice it's defective (seen this too many times.) Source - plumber from Germany
@andyxox41682 жыл бұрын
Stainless … 😂😂😂 bet that’s a dream to work with!
@HeathenGeek5 жыл бұрын
One of the nice things about plastic is it tastes nice when the mice eat it.
@pekkasaarinen29025 жыл бұрын
You tasted it with the mice or after they've eaten it? If it's after then it could be just mouse pee giving the nice taste..
@crackedemerald49305 жыл бұрын
I'm confused, do the _mice_ taste better or do they _like_ it better?
@bigclivedotcom5 жыл бұрын
You'd think the plastic drainage pipes would have been eaten by rats and mice if the plastic was desirable.
@Mark1024MAK5 жыл бұрын
bigclivedotcom - in my experience of mice and rats “eating” PVC, plastic and rubber cable, it’s generally to make a route past an obstruction, or because (in the case of mice) because they are “nesting”.
@HighestRank5 жыл бұрын
They would either like the texture or some flavor which has soaked into the resin, and if both, could chew every bit of it just for the sheer hellofit. Tooth wear is minimal and coincidental, not a goal but an instinct which became necessarily habitual.
@timb70855 жыл бұрын
Interesting video. The PEX ia fairly common in the US now - in my older house which is all copper, some recent repairs to leaking copper pipes has been done with PEX and one line specifically feeds the laundry (washer) which is used frequently and there has been no issues - it's great stuff and easy to work with compared to copper. That bottle air vent looks neat - need one of those for my heating system - it's a water loop from an oil furnace and needs routine "bleeding". Thanks as always for great videos!
@EitriBrokkr5 жыл бұрын
I have never seen a rubber seal last more than 25 years without developing a slight leak, on anything ever. Just saying
@brendanrandle5 жыл бұрын
the o-rings around the base of the injectors in my car built in 1984 are still holding up just fine, pretty sure they've seen more abuse than the ones in this video ever will
@EitriBrokkr5 жыл бұрын
@Dave Micolichek valve cover gaskets develop leaks, oil pan gaskets develop leaks, and if you read the fine print, most of today's "quick" plumbing products, like every pex product I've ever seen, says right on the package, rated for 25 years
@EitriBrokkr5 жыл бұрын
@@brendanrandle first off, your intake is usually under vacuum so you wouldn't know even if they were, secondly there is zero pressure there, if anything considering the vacuum, it's negative pressure
@brendanrandle5 жыл бұрын
@@EitriBrokkrthe top o-rings don't leak either and they're the only thing between 40-45psi(gauge) fuel and atmospheric pressure
@brendanrandle5 жыл бұрын
may not be rubber though
@littledanmcnamara18405 жыл бұрын
Reminds me of conversations I'd have with my grandad, he was a plumber all his life. I never had a clue what he was talking about back then. Would love to see more of these videos
@HighestRank5 жыл бұрын
Little Daniel McNamara this that these those. Most men are plumbers their entire lives🏣⛲️, suffer testosterone.
@SebBrosig5 жыл бұрын
we replaced lots of plastic with copper... because of mice nibbling heating pipes.
@idiotstupid59045 жыл бұрын
get a cat?
@HighestRank5 жыл бұрын
idiot stupid cats can’t get behind cabinets and go everywhere, stupid idiot.
@accountshanahan5 жыл бұрын
Have used JG speedfit for years, works really well and so simple to install compared to copper
@Richardincancale5 жыл бұрын
Known in Scotland as a ‘snifter’ valve. Same word for a wee dram...
@BoB4jjjjs5 жыл бұрын
They are brilliant for quick repairs, just make sure the fitting itself is protected from frost as they can expand with ice if frozen and burst. I have seen the pipe itself burst, but it has to freeze solid. Use it and you will not have any problems for at least 10 years, though I have seen it in for decades without any problems at all. If you use it foe central heating you will have very little loss from the plastic pipe between radiators. Very simple to protect against frost with a small bit of copper pipe on the return to the boiler and a pipe star to bring on the boiler to give a few degrees of heat before turning off the boiler again. Have to say though, if you have oil or propane to make sure you have enough to keep system going, it will not use a lot, but in bad frost it can be surprising. I have used these fittings without any problems. Fit and forget, but just make sure the fitting itself is not exposed to hard frost.
@HighestRank5 жыл бұрын
It’s the same concept as a compression fitting, which I have seen shove their pipes out after a light freeze, and as such I do suspect your assumption to be correct.
@zx8401ztv5 жыл бұрын
I distrust plastic as well, i cant see plastic lasting like the copper pipes in your house. I live in a house from 1948, all but one copper pipe is original, 71 year old copper pipes.
@dgedi785 жыл бұрын
Same I trust copper, traditional brazing and mechanical junctions are made to last.
@stewartmcdonald41215 жыл бұрын
Im in 50 yo copper piped house. no problems.
@junits155 жыл бұрын
Agreed I don’t trust these o-ring seals to last.
@chrisluke77865 жыл бұрын
Even slightly acidic water causes pitting in copper pipes, with the system often not making it to even 10 years. I much rather have a home-run manifold PEX system. With that you only have worry about leaks at the manifold and endpoint with no junctions to leak.
@jason-ge5nr5 жыл бұрын
I redid my house in pex 5 years ago. It was pex-b, and I used the stainless steel crimp rings. Our push to connect fittings dont have the collet to tighten which is kinda neat. The pex is cross linked polyethylene. Which is something to do with the chemistry of the tube.
@geoffpriestley70015 жыл бұрын
Dont use the push on fittings on chrome pipe it wont grip
@6581punk5 жыл бұрын
Copper is softer I guess.
@WineScrounger5 жыл бұрын
6581punk yes- chrome is really very hard, they use it for lining gun barrels. The teeth won’t touch it.
@Stigstigster5 жыл бұрын
Where you have to use them on chrome pipe you can carefully file/flake away the chrome plating and then use the pushfit as normal. I've had to do it a few times over the years and works just fine. Just don't be too aggressive with the file as you need to keep the pipe unmarked. The same goes for soldering that kind of pipe.
@HighestRank5 жыл бұрын
Maybe this space is the place to apply steel wool.
@Sylvan_dB5 жыл бұрын
A few years ago I replaced a bit of plumbing with pex tubing in a very accessible area. I've gained confidence thru observation. Now doing full repipe with pex. Slowly. :) It will be nice to get all (or nearly all) of my plumbing to be pex. Currently I have mostly galvanized steel (with some segments nearly closed off with rust and calcium buildup), some copper, some polybutylene and increasing amounts of pex.
@namespacetoosmall5 жыл бұрын
Yeah, the plastic will last, it will be around for 10,000 years. XD
@wannabetechnician74515 жыл бұрын
longer than the nuclear waste is radioactive
@EitriBrokkr5 жыл бұрын
It will be brittle, broken and cracked, and the orings will have dry rotted and split years before, but it will still be around...
5 жыл бұрын
10,000 years is a long time for a water leak
@lacossanostra5 жыл бұрын
never heard of plastic eating microbes ?? clearly not so your fair mongering doesn't hold
@punker4Real5 жыл бұрын
photo degrades
@roberthorwat67475 жыл бұрын
Using push fit in older houses with imperial pipes can be interesting. Half inch is no problem. It's practically identical to 15mm and modern compression or push fit fittings work just fine. Next size up is 3/4" though and if you bugger about with those you need a couple of three quarter to 22mm reducers and some 22mm pipe. Inelegant but functional
@MrGoatflakes5 жыл бұрын
"no electronics whatsoever" nonsense, electricity is a sort of water, they taught me that at the technical college!
@pyromen3215 жыл бұрын
I didn’t know magic pixies could swim
@HighestRank5 жыл бұрын
pyromen321 angry* pixies can swim, though it’s those unyielding nymphs which are found in pipes.
@HighestRank5 жыл бұрын
MrGoatflakes they said that water flows, is stored in tank circuits, both run in currents but nothing so similar as being a ‘sort of water’, unless you attended Hogwarts.
@stewartcaldwell52995 жыл бұрын
Clive, I've refit about half my (old) house with pex. I use Sharkbite brand fittings (US). Never have had a molecule of leakage. Well, you know what I mean. I used red tubing for hot water, blue for cold, and orange for the boiler (especially made for heating systems. Even gases can't pass through the orange). So easy !! Also insulates better than copper.
@BedsitBob4 жыл бұрын
"playing with something that can flood your house out." Stop bragging.
@srowley855 жыл бұрын
The first place I saw compression fittings like the one you showed was for gas fittings. All you had to do was make sure the Teflon tubing end was clean and right angle, and then press the tubing in until it bottomed out. It could withstand at least 150 psi of nitrogen. I’ve since helped install a water heater using fittings of this type with copper tubing, and everything has been trouble free. It’s a hell of a lot easier than sweating pipes!