Looks good though I would have tried to run the cable below pebble dash level so it blends in more
@thecableguyuk Жыл бұрын
The gas box was preventing me from doing that, otherwise I would of. Thanks for your comment 👍🏼
@r3co0 Жыл бұрын
@The Cable Guy you could easily have dropped the cable after the gas and hid it under the rough cast trim on the bulk of the wall.
@williamyates2794 Жыл бұрын
Looks an eyesore
@stevehurrell Жыл бұрын
Electricians and plumbers always take quickest / easiest route from A to B
@Matr1xOne1 Жыл бұрын
Great job, but if it were my house would be kindly asking to rerun that cable around gas box and below dash
@saphaelectrical Жыл бұрын
Kenya's not yet big on EVs but from you and Artisan electric I've learnt a lot to give me base knowledge on this. In preparation for the time the kenyan market will embrace EVs
@ef7480 Жыл бұрын
Be careful what tech you embrace.They aint that green or economical but fair comment..
@saphaelectrical Жыл бұрын
@@ef7480 sure
@CastleKnight7 Жыл бұрын
@@ef7480They are when connected to solar.
@helix5779 Жыл бұрын
@@ef7480 how so?
@markrainford1219 Жыл бұрын
EV costing more to run than ICE at present. Plus production is more polluting and energy consuming than ICE cars. The list goes on.@@helix5779
@thomasjiggins9286 Жыл бұрын
Great job ,only concern to me is if I was a paying customer I would of insisted the cable was routed under the unmarked rendering in cream.and run along the brick work . End result big black cable not seen on cream wall. But other than that great install.
@JBSONLINE11 ай бұрын
The install was great. You guys need to relax, I’m sure if he could make it better he would. I personally found his work amazing and would defo hire him. He knows his stuff so stop hating on him.
@MMD-z6z9 ай бұрын
nah, black cable is an eye sore on white background... Could have used white cable if he didnt want to run cable under the pebble dash/brick line...sorry but its Poor workmanship
@kobirelf978 ай бұрын
@@MMD-z6zIt's not poor workmanship if the customer is happy with it that's all that matters
@andyskinner54207 ай бұрын
er, we're not hating the guy BUT as an an electrical contractor he should have paid more attention to the cable run location!
@Proxima04 Жыл бұрын
Thanks for taking the time to make this video, as someone about to have one installed by my electrician, it’s good to have something like this as a heads up. 👍
@scottreynolds8917 Жыл бұрын
What did you do with the load management CT???
@spawnterror10 ай бұрын
Probably nothing.
@MrMWRMWR5 ай бұрын
I had the same question as there's measurement for charger and separate grid (+ any PV and battery) to provide input to the MyEnergi app. Wireless vs cable layout needs planning. Surely, if many Zappis previously installed, this is a critical topic to at least mention.
@andyskinner54207 ай бұрын
agree with the other comments re cable run... should be positioned along the lower brickline plus I'd have used a piece of white conduit to bring it up the wall vertically
@johnelbro1279 ай бұрын
Great neat job well done. 👍👍👍
@lewisb.3242 Жыл бұрын
Only thing I’d suggest is disconnecting the flat cable from the front portion of the charger while you’re installing it so it’s not dangling from the connections just to save anything getting broken. Looks a good job though.
@arjansingh4971 Жыл бұрын
No CT clamp on the main tails??
@danhailat10 ай бұрын
Nice clean work.
@Micha4354-h8k3 ай бұрын
Great job finally i understand thanks bro 👊
@Geordie_Peter Жыл бұрын
Hi, did you provide a Part P installation Certificate to the customer to satisfy Building control?
@93lornamae11 ай бұрын
Do yiu not out a CT on the tails going into the EV CU?
@MrTubeman007 Жыл бұрын
Why didn't you run the armoured below the dash render, it would have tucked under there nicely, instead they have a long black washing line right across the white wall.
@thecableguyuk Жыл бұрын
If you watch the whole video you will see that the gas box was there so it couldn't work 👍🏼
@MrBatchy12316 сағат бұрын
good job where are you based?
@legendhero996 ай бұрын
Hi, How come you put a fly lead on the banjo at both ends? I thought you only needed it at one end as the armour is earthed from the one banjo as it is continuous? Tks
@mattsan708 ай бұрын
No PEN fault protection needed? TNCS earthing bonded to N
@suhailwajid50403 ай бұрын
EV charger installed skillfully.
@oliverrice88699 ай бұрын
That looks really tidy.. I’m having an ev charger fitted in the coming weeks. I hope they do as nice a job as this.
@pikricky Жыл бұрын
Good video once again,would it not have been possible to run the cable round the red brick so it was under the rendering and less visible or was the gas box too close to the wall for you to feed the cable behind it cable
@thecableguyuk Жыл бұрын
The gas box was preventing me from doing that, otherwise I would of. Thanks for your comment 👍🏼
@mattsidebottom76036 ай бұрын
Im having one fitted soon. I dont want it to go to the old consumer unit cos it means pulling up floors. Is it straight forward to fit a seperate consumer unit if the main fuse is easy to access?
@ChrismalkinukАй бұрын
How much would this install cost? Cost of the unit? How much to fit the unit?
@trickydicky90 Жыл бұрын
Nice job, if I live in a first floor flat, own the leasehold and own the car port below, can one of these run from my flat consumer box to the car port?
@tcv8543 ай бұрын
If the EV charger has a built in RCD and the cable supplying it was armoured, would you need to have an upstream RCD in the new external consumer unit?
@TheGunnersman932 ай бұрын
Doesn’t need to no
@mtbosvaldas Жыл бұрын
Hi. what size cable sq? Thanks
@combok66010 ай бұрын
I have same question.. What's size cable please?
@Browneyedbrummy Жыл бұрын
Hi mate Nice set uo there ! Is your rcbo double too switch the neutral or single pole ? Ive been told its now part of the regs too supply the zappi with and rcd/rcbo protected circuit that switches both live and neutral conductors! Even though the zappi has built on type a and pen fault its not compliant as the built in rcd is on a circuit board
@richardwalsh58824 ай бұрын
That has always been the requirement that the RCD must interrupt all live conductors.
@bullhurley-uv8ys Жыл бұрын
Nice job, how about putting the cable in some white 25mm conduit? Would of blended in like a dream.
@munafmufc01 Жыл бұрын
Nice job. What about the ethernet cable and ct clamp ? Why is it missing?
@bsesin Жыл бұрын
@@munafmufc01 missing for what reason ??
@ms.electrical Жыл бұрын
Why would you choose not to install the ct clamp that comes with the unit 🤷♂️ even if its just to future proof it for if they want to use solar features ect later on or incase you got the maximum demand wrong or demand changes if they get new or additional high load appliances
@mradam4430 Жыл бұрын
Brill, thank you. Still your favourite EV charger?
@Stirtp33Ай бұрын
What’s best to use Ultra EV 6mm 3 core with cat 5 or 6mm 3 core swa ?
@johnmcfadden7418 Жыл бұрын
Good Job geez. I have not installed one yet but I do agree I would have tied in under the wall covering if there was enough cable? that is the only reason not to have done so unless there is another reason but apart from that very neat and nice to see. what benefit to the client is the anti tamper device does it trip the breaker?
@thecableguyuk Жыл бұрын
I can't remember if I mentioned it but If you notice on the video there is a gas box on the front face of the property that is the the reason for having to go this high. Usually I would run the cable below the dpc for a more eye pleasing finish.
@thirurajah1 Жыл бұрын
What thickness wire you are using from consumer box to charger?
@thecableguyuk Жыл бұрын
6mm
@smokin999uk Жыл бұрын
Im guessing given i only have a 63 amp mains cutout fuse AND my electric is looped with my neighbour, its a no-go with regards to get an EV point unless im willing to dig up driveways?? 😢
@Adam-Electrical Жыл бұрын
Not necessarily You could always make use of the dynamic load management and install CT clamps round the mains tails and set charger to 60Amps
@angusmackenzie59259 ай бұрын
Why not use a white cable to blend in with the house 🤔
@mohamedsiadabdille7631 Жыл бұрын
Nice job, mate really I appreciate very much your time also you try to film and do job same time is not easy your own understand that as well but all good
@javadchohan8 ай бұрын
what is the tamper fit pcb for ?
@laatu1234Ай бұрын
Typically the cable to the charger is ran in an aluminium pipe. It makes the cabling abjt better protected.
@Margap Жыл бұрын
What happens when there is no Internet? Can you charge your car with zapping?
@johnbower3 күн бұрын
Instead of going around the corner of the house it would have been a lot neater and out of the way if you installed the charger on the wall near the gas supply box, It looks as if a six metre charging cable would have easily reached from there to where the car would be parked.
@stevelambert6689 Жыл бұрын
I guess the level you used has "sealed for life" batteries. 😀😁😂 work's first time every time.
@tommyoxnard9100 Жыл бұрын
It looks a lot easier to fit than the other types on the market. Quick question, do you need to fit the CT clamps with this make of EV charger? I need guidance in selecting a good, reliable make. Thanks.
@thecableguyuk Жыл бұрын
Hi, you are recommended to yes but you can also install them without and change the settings in the EV charger.
@colin5064 Жыл бұрын
That cable routing will cause a stain to appear on that white dashed wall, l give it 18 month at most
@M0PAX9 ай бұрын
Just watched a video from sota on KZbin and myenergy won’t except a warranty claim unless the charger is protected by a DP RCD
@kopynd110 ай бұрын
all the vids seem to show you the easy installations on new build, nothing showing homes built 60/ 100 yrs ago with the meter inside at the back of the house,and the consumer inside at the front in door bottom of the staircase which is about 15 mtrs away from the meter feed entry point
@bsesin Жыл бұрын
isnt that a camera tripod against the van ?
@thecableguyuk Жыл бұрын
It's the laser tripod, a Dewalt one I use a lot. This is all filmed on my phone!
@bsesin Жыл бұрын
@@thecableguyuk ah ok , wonder if you can get an adaptor for a phone holder for that .. maybe
@tonywebb99094 ай бұрын
Electrically sound job, but as others have said not not got 1st class looks! I always wire back to the main CCU, and use the CT clamp to control the current. Just have to lift a few floor boards and charge for two more hours. And where is the external isolator? Any equipment over 3Kw requires a double pole isolator within 1.5meters. This is the problem when people learn to do things parrot fashion and not read the wiring regs. None of this is a dig at you, you seem to enjoy your work and thats great.
@russvhill2 Жыл бұрын
Still waiting for the follow-up video showing installation of white trunking to cover up the amateur placement of that black cable. You might get more customers if they see you're prepared to make good a poor decision.
@honisoitquimalypense131610 ай бұрын
Must be difficult being perfect in everything you do. I dont know how you do it.
@Bawa-jee0072 ай бұрын
Share your details I need charger as well
@Max-cz8by Жыл бұрын
You say you’ve fitted loads of Zappi’s? Have you done the EV qualification? *No use of the CT for load limiting? *RCBO is single pole - type AC (should be double pole - type A) It’s good to have a base knowledge of the regulations on EV
@thecableguyuk Жыл бұрын
Hi Max, Yes I have and so has everyone that works for us. The CT clamp is not mandatory in all installations if you speak to myenergi direct, if you also read the installing guide on the CT clamp online you will find this information. This is also the exact consumer unit that BG populate designed for EV charging supplies. Thanks for your comment however, it's helps others who may have the same questions. 👍🏼
@Max-cz8by Жыл бұрын
Apologies, I didn’t mean to come across overly critical. I know the CT clamp isn’t mandatory and you can negate it’s use through calculating maximum demand. As a Myenergi authorised installer we tend to fit the CT’s as a matter of convenience and best practice. It’s worrying that BG are providing EV CU’s with type AC RCBO’s though! I’m sure you are aware that is a major no no?! You’re right though, it’s valuable to raise these things if it helps others.
@efixx Жыл бұрын
@@thecableguyuk The BG boards we’ve reviewed for EV have a double pole RCB0. You’ve used the single pole version CUCRB40. Part number for DP is CUCRB40DPA 13:48
@thecableguyuk Жыл бұрын
@@efixx I've contacted them about this, your not wrong.
@geraldelwood9660 Жыл бұрын
@@efixx Do you have any idea why a double pole RCBO is mandatory ? can't be anything to do with Open PEN; as the isolator for that is a triple pole anyway.
@tonyforward6342 ай бұрын
Wouldn’t be happy with a black cable on white render though!
@tommyjakobsen5504 Жыл бұрын
are you autosized to do that.. are you exucated to do this. otherwise this is NOT leagal to do buy you self.
@ef7480 Жыл бұрын
Just an obsevation. You fitted the anti tamper PCB but didn't explain what it does. Nice job all the same.
@newlinerealboi3434 Жыл бұрын
It’s to make an old stock charger compliant with the new regs.
@drpantastic1969 Жыл бұрын
Whats that bush infront of the consumer unit should we be concerned?👀🥦
@rychuu24 Жыл бұрын
Good job but the cable on that high is not acceptable.
@Adam-Electrical Жыл бұрын
No DP RCBO and its a type AC 😮
@thecableguyuk Жыл бұрын
Got changed, that's how it came from bg. Wasn't until we checked before we realised 👍🏼
@pete98715 Жыл бұрын
oh man, i can't stand seeing cables along walls like that.
@niallchurch26798 ай бұрын
I agree with others cable could be better installed!
@JohnDundee-el2ro10 ай бұрын
Hi pal sorry but I just think the cable clipped surface round the wall is an eye soar and I would not have allowed that at my house just pity you could not hide it under the ground then down from main and up to zappi this is not to say you are not good at your job it's just that cable install round the white wall
@RichardABW Жыл бұрын
Sure it all worked fine but that cable would make me find someone else for the next job. And as the customer I’d probably find myself re-running the cable myself!
@albancibaj Жыл бұрын
Why? What’s wrong with the cabling. Looks pretty neat to me..
@RichardABW Жыл бұрын
@@albancibaj Sure it's neat, but I can see a lot of it. I want to minimise the amount of cable I can see! My radiator pipes were chased in when they had to be redone for the same reason.
@albancibaj Жыл бұрын
@@RichardABW Yeah I sort of agree. I think it should have been installed a bit lower because it’s too visible for the house.
@honisoitquimalypense131610 ай бұрын
@RichardABW so you'd get someone else because of the cabling, even though the job is neat ..... yeah that makes sense, risk someone you don't know potentially doing a worse job, instead of just saying when discussing the job you'd like the cable running below the render 🤔.
@RichardABW10 ай бұрын
As I said, I'd probably just re-do myself. With trades I find often things like this are mentioned before hand and then get forgotten anyway.@@honisoitquimalypense1316
@kobirelf97 Жыл бұрын
Who did well but that cable could have gone a lot lower it looks horrible like that
@thecableguyuk Жыл бұрын
If you watch the video fully you will listen to the reason why is was run at this height. The gas box was restricting it
@stocksretreat123 Жыл бұрын
Tardy install. That cable looks a right mess. Run it to the lower level. Just lazy, or what.
@honisoitquimalypense131610 ай бұрын
Let's see your work?
@01theloneranger Жыл бұрын
I would not be happy at all.....Black cable on a white wall? No. Use white cable or fit to the brick below.
@thecableguyuk Жыл бұрын
Hi Rodger,, I totally agree with you. This was the specification of the job when we took it on so we completed it as we were asked in the way we were asked. Thanks for your comment.
@01theloneranger Жыл бұрын
@@thecableguyuk Sorry.....Your customer is at fault. They have no idea of aesthetics do they?
@leelipinski46674 ай бұрын
@@01thelonerangerCustomer is always right. He did as he was paid to do.
@polomint466 ай бұрын
Crap installation. Assume the customer paid the see the supply cable?
@andrewstafford-jones4291 Жыл бұрын
The cable routing is a disaster - it should be removed and installed at the pebbledash juncture. I would be ashamed if it looked looked like that.
@andrewstafford-jones4291 Жыл бұрын
Totally agree - this is disgraceful install, we see this all to often when the spark's "don't give a sh*it" about the install.
@dereklee8080 Жыл бұрын
Omg, if he attached that black cable to my house as he has done in this video he would not be getting paid until he reinstalled the cable in a more discreet location and then filled in all the holes in that house wall and repainted it, what a shoddy lazy arse job
@honisoitquimalypense131610 ай бұрын
How do you know he's not had a discussion with the house owner beforehand about where the cable is going? Everyone is quick to judge other people for their work. You sound like someone who would be a nightmare to do a job for.
@KenSmithKPSELECTRICAL Жыл бұрын
Part of being a good electrician is an ability to hide cable's, not the best install I've ever seen.
@LeeThompson-m8v5 ай бұрын
Full of dealer just trying to get consumer to accept low ball offers
@MrVoytek10007 ай бұрын
Black cable on the wall, not acceptable.
@christophermo13 Жыл бұрын
Mate. That black cable across white wall doesn’t look great. Why wouldn’t you run it lower just under render level?
@MaraxYTube Жыл бұрын
is it ok to buy 22kw version but still charge 7kw output? Just to be future proof?
@richardwalsh58824 ай бұрын
Yes it is - but you will only be able to use one of the CT inputs as the others are reserved for L2 and L3.
@samgreenfield65095 ай бұрын
What size cores have you used to feed the RCD from the cupboard?