I have never seen these questions pop up in any of my industrial electrician/ instrumentation job interviews, except for how to measure 4-20mA and what is a TC, RTD. This is some pretty advanced stuff. The ones Ive always been asked are: 1.Explain 0-10V and 4-20mA and pros and cons. 2. What are the color of the leads of a Thermocouple? Which one is + and --? 3. Do you pour water into acid, or acid into water? 4. How do you terminate a shielded cable. Which side of the cable do you ground? 5. What does 3-15 mean? 6. Do you know what zero and span means? 7. How do ultrasonic sensor work? Theres a couple others that always come up. Theyre pretty basic.
@InstrumentCalibration Жыл бұрын
Hello Thanks for your valuable feedback on this video
@MR-nl8xr Жыл бұрын
Good Comment. Do you have the answers for those questions?
@InstrumentCalibration Жыл бұрын
We do@@MR-nl8xr
@imayleakount9610 Жыл бұрын
What other questions can you think of that would probably come up. Any videos/literature that someone who has been out of the field for a while could use to brush up on instrumentation basics? Thanks
@InstrumentCalibration Жыл бұрын
Hi @@imayleakount9610 We have made a decent chunk of videos on HART, CONTROL VALVES, and basic instrumentation interviews. Kindly check those :)
@RaviKumar-ex9ne8 ай бұрын
Very useful video
@InstrumentCalibration8 ай бұрын
Glad you liked it
@sihlemlangeni192911 ай бұрын
Thank you very much. The Q&A is simple to understand and on point . This has helped me a lot .
@InstrumentCalibration11 ай бұрын
Thank you. I really appreciate your comment
@rodrigabtonio22033 ай бұрын
exelent, GOD BLESS
@sulusk267 Жыл бұрын
It’s good one
@InstrumentCalibration Жыл бұрын
Thank you
@mr.omprakashbarure498111 ай бұрын
Excellent❤
@InstrumentCalibration11 ай бұрын
Thank you
@faisalmalik7408 Жыл бұрын
exilent 👍
@InstrumentCalibration Жыл бұрын
Awesome
@gugulothuvenkateswarlu6814 Жыл бұрын
Exallent
@InstrumentCalibration Жыл бұрын
Glad you liked it
@rakeshrajak7655 Жыл бұрын
Thank you sir Very nice
@InstrumentCalibration Жыл бұрын
Thanks Rajesh for watching this video
@charanmvg64338 ай бұрын
transmitter mounting for steam service .picture equlising valave position check once.
@SlimaneAutomation7 ай бұрын
Thanks for the information
@harikumarhari88827 ай бұрын
good😍
@InstrumentCalibration7 ай бұрын
Thanks!!
@albarslane8599 Жыл бұрын
It's very good explication but there are many information at once sow if you dont mind i have a proposition what if you did mini vidéos ans focos on evry part at once thankyou
@InstrumentCalibration Жыл бұрын
Hello Alb We have created series of video too. Please see below links. 1. kzbin.info/www/bejne/ap3FfH-rd5KWiNU 2. kzbin.info/www/bejne/ap3FfH-rd5KWiNU
@alpeshpatel7111 Жыл бұрын
NicE
@InstrumentCalibration Жыл бұрын
Thank you
@RaviKumar-fs4cp10 ай бұрын
Thank you
@InstrumentCalibration10 ай бұрын
you are welcome
@muscatmama6 ай бұрын
Fantastic
@sundaramnarayanan137511 ай бұрын
add questions on Cold Junction compensation?
@eggxecution3 ай бұрын
nice
@kirankumargadwal4678 Жыл бұрын
Thank you, almost all important questions are covered. Please do more videos on interview QA
@InstrumentCalibration Жыл бұрын
Hello Kiran Thanks for your comment. I will post more videos on interview questions and answers in future.
@asingwirebonus3479 Жыл бұрын
Thank you for the video. Help me send me a video on analog scaling in PLCs
@InstrumentCalibration Жыл бұрын
We will send it shortly
@KiranKumar-hk3zk Жыл бұрын
Please make a clear video of AI AO DI DO signal connections from field to dcs
@InstrumentCalibration Жыл бұрын
Hello Kiran I will make clear video on this topic soon.
@OmkarRatre-i3j4 ай бұрын
Supper
@okaforignatiaus345 Жыл бұрын
Good day, pls I need a video on CALIBRATING TRANSMITTERS USING HART COMMUNICATOR
@InstrumentCalibration Жыл бұрын
Hi Please check the HART videos on our channel, we have videos on the requested topic Let me know if you want us to provide the link in the comment section
@MR-nl8xr Жыл бұрын
Diagrams 5:24 and 5:37 are backwards, if you are showing them in "gravity" fashion.
@nuhbellos37947 ай бұрын
Does anyone have any insight into what the physical field evaluation and written evaluation would entail for an E&I Apprentice position? I passed the EEI MASS test and have these coming up. Thanks
@Reeshichohan11 ай бұрын
Sr i am instrument technician can u tell.me which course i do for furture carrier growth.
@InstrumentCalibration11 ай бұрын
Hello Beats Have you done engineering in Instrumentation and Control?
@Reeshichohan11 ай бұрын
@@InstrumentCalibration sr I complete.diploma.electeonics and communication and 2 years exp.in instrument and 5+years exp.in electronic
@johnpeter645111 ай бұрын
Can u explain about working of by pass valves
@InstrumentCalibration10 ай бұрын
Hi Thanks for the comment. Our tech team is working on this content
@rkmohapatro9 ай бұрын
this video is vwry helpful for interview
@InstrumentCalibration9 ай бұрын
Thank you
@abdessamedghettas7167 Жыл бұрын
Thanks
@InstrumentCalibration Жыл бұрын
Appreciate the feedback
@jabinantony1284Ай бұрын
😍
@ShaikhAlam-e4k2 ай бұрын
Not Seedback but Seeback effect, you bet!
@sadanalasaran83355 ай бұрын
VIDEO is super nice explain but video is high
@heatherquick40957 ай бұрын
Commissioning a DPT is wrong , for some meters this procedure would destroy them straight away.
@jackfeak23647 ай бұрын
I agree. I would think bypass closure would be last. If you open the HP side first with the bypass closed the transmitter would see a very large pressure differential. Example: if the transmitter was taken out of service or replaced on a 450lb steam flow system and you opened the HP side the DPT would see a 450 lb differential. Often times steam flow transmitters are calibrated 0 to 100 inches of water using orface plates so damage could be a real possibility.
@karoly3653 ай бұрын
@@jackfeak2364The steps mentioned in the video is first open EQ and then only HP. Then why do say it is the opposite.
@AlwellNwogu Жыл бұрын
I'm interested in learning about instrumentation and control What is the easiest way to learn instrumentation
@InstrumentCalibration Жыл бұрын
Hello Alwell You can start with our videos. If you watch all our video, you will definitely get some basic knowledge about I & C.
@Practical.instrumentation Жыл бұрын
Search Practical Instrumentation Channel
@theomnyakeni42887 ай бұрын
Why are we using 4-20mA and not 0-20mA?
@georgemoholo1928 ай бұрын
I need psychometric test
@sushildurafe9037 Жыл бұрын
Why HP & LP tapping is done at 45 degree in process line for FIT Where K type TC is mostly used Explain transfer of signal from DCS to control valve How to calibrate interface level transmitter. What is actually marshalling cabinet
@InstrumentCalibration Жыл бұрын
HP & LP Tapping is done at 45 degree in process line to avoid any entrapped gases & to avoid any pipe dirt particles in pipe lines Type K is commonly used in nuclear applications because of its relative radiation hardness. DCS sends 4-20mA signal to I/P converter. I/P converter converts 4-20mA signal into 3-15 psi signal. Then 3-15 psi signal goes to control valve to control the flow. I have made one video on Interface Level Measurement. Please see below link. kzbin.info/www/bejne/kGq2Y6Cdi7JmfLc The marshalling cabinet acts as an interface between the system cabinet and field junction boxes. The main cables are laid from the field junction boxes to the marshalling cabinet. The prefab cables from the system cabinet IO cards are also terminated in the marshalling cabinet.
@sushildurafe9037 Жыл бұрын
@@InstrumentCalibration Guided wave radar type interface level transmitter calibration, what will be zero and 100? Working principle of ESDV and types?
@sushildurafe9037 Жыл бұрын
@@InstrumentCalibration When FIT is showing zero what will be position of FCV fully open or close.