Intellitouch Control Panel, Walk-thru, demo

  Рет қаралды 41,506

Swimming Pool Tips, Reviews & How To - SPL

Swimming Pool Tips, Reviews & How To - SPL

Күн бұрын

WEBSITE: www.swimmingpoo...
KZbin Video Index -- A list of all of my videos: poolmandave.blo...
Related Videos:
Jandy Valve Actuator not turning, valve failure: • Pool Valve Actuator Fa...
Aqualink RS by Zodiac, walk thru and demo: • Aqualink RS by Zodiac,...
NOTES:
This video shows you a quick Demo of the Pentair IntelliTouch Control Panel. If you are thinking about investing in an automated system, watch this video to see how it works.
If you own this panel already, I show you some basics in operating the panel
Mrdgvb1 Social Media Links:
Google +: plus.google.co...
Blogger: poolmandave.blo...
Facebook: www.facebook.c...

Пікірлер: 34
@teacherlynn671
@teacherlynn671 5 жыл бұрын
Thank you again but just for edification and the possibility to help someone else I want to tell you what happened. As stated before my Intelliflow pump would not shut off. I have an older i5 Pentair control system. You had recommend checking the relay which after checking closely had both supply and load voltage under one screw so it was bypassing the relay. So one screw on one side with two wires underneath and one screw on the other side of the relay with two wires underneath because it is 220 Volts. Basically, it had the same effect as putting supply and load under a wire nut. On Off and On, I had heard the relay click so I knew the relay was working, but the pump would not shut off. The problem I had was it had been installed by a previous owner and had worked for at least 18 years like this so I was leary to change wiring but when I saw a schematic I knew I was right.. I had worked on the inside control panel and deleted some unnecessary programming and that started the problem. I wired the relay correctly and it is working fine. On and off manually and when controlled by timer or indoor panel Originally, I had CLEANER in the Main Screen and another CLEANER in Features and when I deleted it the trouble began. I believe the pump was being controlled NOT by the relay but from the programming which is bad wiring. Even though it was wrong it worked like that for 18 years. My wife gave me an earful and told me not to touch anything but with your help we got through. Thank you again. Flowers and chocolates and all is good here and thanks again.
@the.trollgubbe2642
@the.trollgubbe2642 2 жыл бұрын
I have the same, o get error retrieving data,
@SPL
@SPL 2 жыл бұрын
Check the antenna and maybe give Pentair a call.
@the.trollgubbe2642
@the.trollgubbe2642 2 жыл бұрын
@@SPL mine is wired , but I will call Pentair, thanks for the tip
@nawaration7925
@nawaration7925 Жыл бұрын
Can you connect that control panel to the pentair phone app?
@SPL
@SPL Жыл бұрын
Not without their wifi upgrade kit.
@octavianoguzman3640
@octavianoguzman3640 2 жыл бұрын
I just got my first pool ever, so this was very helpful. Can you somehow control this via a a mobile application?
@SPL
@SPL 2 жыл бұрын
Only with an upgrade kit. Somewhere around $500-$600
@octavianoguzman3640
@octavianoguzman3640 2 жыл бұрын
@@SPL Thank you for the reply! My pool came without a remote, so I have to control everything through the actual control panel. My pool guy said to just buy the remote, but hard to know which one will work on it and now that I am learning it wont come with a feature to control it remotely via mobile app, I kind of feel like just swapping out the entire thing. When you say an upgrade kit, do you mean the entire system?
@miston6055
@miston6055 Жыл бұрын
I have a question, what do I do if my spa mode isn’t turning the actuator to cut off the pool suction? The actuators work okay manually - Thanks in advance
@SPL
@SPL Жыл бұрын
Could be a bad actuator. I would replace it.
@mfender8938
@mfender8938 6 жыл бұрын
How do you drain your pool using your control panel box
@DerrickConti
@DerrickConti 10 жыл бұрын
You might wanna change that temp sensor
@teacherlynn671
@teacherlynn671 5 жыл бұрын
Also I have a Pentair 520164 Version 1050 and I wonder if it is bad where do I find one?
@TheMillionaireMindset
@TheMillionaireMindset 4 жыл бұрын
Can the inside touch panel adjust the valves, for instance all day my pool pump runs, and delivers 1/2 of the water back into the spa and 1/2 of the water back into the pool, so the waterfall is a trickle. If I go outside to the main panel and put it into service or timeout mode I can press the valves button twice and then it changes the output to be 100% the spa and the waterfall is full force. Can the inside panel control those valves too? I have the same setup you are showing in this video.
@SPL
@SPL 4 жыл бұрын
Yes, you can add a spillway program and this will put the return valve into full spa mode giving you 100% return to the spa and the spillway. I would shorten the daily program and add a 4-6 hour spillway program in the afternoon/evening to give you that nice waterfall effect. Look in the program for spillway
@kyled1201
@kyled1201 3 жыл бұрын
Is there a way to program auto mode and over-ride the remote without the remote after having lost the remote? It seems the auto mode changed on its own, I don't know why. It was running in spa-fill mode, now it's running in spa drain mode while in auto.
@SPL
@SPL 3 жыл бұрын
Could just be the switch on the valve actuator got flipped.
@kyled1201
@kyled1201 3 жыл бұрын
@@SPL Thanks for the reply.. Its actually that the control box is showing drain mode. But I'll just reverse the actuator and that will solve it. So I'm not the only technician who doesn't know how to over ride the remote? Lol
@TheMillionaireMindset
@TheMillionaireMindset 4 жыл бұрын
What if my pool has multicolored lights? How do you control and change the lights with that same system?
@SPL
@SPL 4 жыл бұрын
If you have Pentair LED lights you should see that appear in the menu if they were wired to the outside board.
@TheMillionaireMindset
@TheMillionaireMindset 4 жыл бұрын
Swimming Pool Tips, Reviews & How To - SPL it just has the Lights option inside on the digital menu. When I go into lights, there’s an option to “sync” and some colors change briefly, but haven’t been able to get it to be “customized.
@FreedomPoolServices
@FreedomPoolServices 4 жыл бұрын
how di i get to cool down mode?
@teacherlynn671
@teacherlynn671 5 жыл бұрын
My indoor panel is supposed to shut off at 5PM and the light goes off but the pump does not shut off. I do not know if it is the Pentair Intellitouch Control Panel inside the house is bad or could it be something else? Any ideas? Everything starts correctly at 11AM but it does not shut down at 5PM even though the light inside next to POOL goes out.
@SPL
@SPL 5 жыл бұрын
I would try resetting the breaker on the outdoor panel. Turn all power off for 30 seconds and then back on. Then if it still does this it is probably a bad relay on the panel. Not a major issue.
@teacherlynn671
@teacherlynn671 5 жыл бұрын
@@SPL Thank you but how do I find the relay? I really appreciate your time and I am looking at your videos on cleaning the pool tiles---again…lol
@teacherlynn671
@teacherlynn671 5 жыл бұрын
@@SPL Thanks but it is not the relay. Do you have any other ideas?
@mrhatman6584
@mrhatman6584 10 жыл бұрын
hello again I have a compool automated system that will not shut off. when time comes to shut off a "delay" starts blinking and I have to turn off manually. Any ideas why this is happening? Thx
@SPL
@SPL 10 жыл бұрын
There is a delay programmed in when the spa is being used and then you turn it back to pool mode to allow the heater to shut down properly. I think it is like a 1 1/2 minute delay. Is that what you are referring about?
@mrhatman6584
@mrhatman6584 10 жыл бұрын
Swimming Pool Tips, Reviews & How To -MrDgvb1 No its the normal run time. The pool keeps running and does not shut down. When time comes to shut down. Keeps going and that delay light starts blinking.
@teacherlynn671
@teacherlynn671 5 жыл бұрын
James I now have the same problem and what did you find out?
@highschoolknifefight4610
@highschoolknifefight4610 7 жыл бұрын
Why does the panel say "POOL ERROR?" I noticed yours does in the video
@SPL
@SPL 7 жыл бұрын
If I remember correctly that error is for a bad temp sensor in the heater. Sometimes the panel just needs to be reset to clear it. Reset the panel by pushing the "Reset" button and then follow that by hitting the number "5" button.
EasyTouch® Pool and Spa Control Programming Schedule, Cleaner, Pump RPM, Salt
8:31
Swimming Pool Tips, Reviews & How To - SPL
Рет қаралды 131 М.
Pentair EasyTouch Panel Overview (Basic + Advanced Features) Outside
18:29
Throwing Swords From My Blue Cybertruck
00:32
Mini Katana
Рет қаралды 11 МЛН
Pentair IntelliValve™
1:47
Pentair
Рет қаралды 17 М.
Should I Get an Automation System for My Pool?
5:56
River Pools
Рет қаралды 36 М.
Coneccion de IntelliCenter de Pentair
11:33
Geo Vasquez
Рет қаралды 11 М.
Pentair Intelliflo pumps, Programing and features
17:01
Swimming Pool Science
Рет қаралды 496 М.
EasyTouch® Pool and Spa Control Outdoor Panel Overview
2:56
Swimming Pool Tips, Reviews & How To - SPL
Рет қаралды 180 М.
SWIMMING POOL PLUMBING SYSTEMS | (800) 766 5259 | ePoolscapes.com
8:57
TheMichaelChaffee
Рет қаралды 759 М.
How to install an Intelliflo pump on to a intellitouch system
3:59
Craig Wooster
Рет қаралды 25 М.
How to turn on the heater with a Pentair EasyTouch
2:11
Technical Pool Repair
Рет қаралды 121 М.
How Many Hours Should You Run Your Pool Pump?
5:29
Swimming Pool Steve
Рет қаралды 51 М.