First use to mainly familiarize myself with set up and confirm timing. Sweet little scope and transducer with easy set up. Get one while you can #automotive #oscilloscope
Пікірлер: 10
@johnnysprocketz2 ай бұрын
Fantastic video dude! Those two channel scopes are sold out, seems as though the quality is above contempt. Impressed with the low cost high quality set up. Subscribed.
@jessemackenzie65162 ай бұрын
Just a heads up. When using the rulers you need the 720 deg rulers . If you move the ruller then hit the gear on the bottom right you can cycle through the rulers . One of them shows piston direction over all 4 cycles of 720
@manelishi132 ай бұрын
My man! I have been trying to find the 720! I saw them on a video set to 720 on the hscope but was unable to find how on the fly. Truly appreciate this, that's what it's all about!
@danielkenkama57012 ай бұрын
The HS502 has fair number of reviews done. Was really waiting on someone to do reviews on the HS512 see it's use in action. Really appreciate you breaking the ice (for me at least)... thanks again.
@manelishi132 ай бұрын
The 502 has half the input voltage of the 512, which in automotive is usually a good thing. One drawback seems to be on very low level signals. I am going to do a video today of an amp clamp that reads in mv. The 512 performs excellent with a transducer where 1 volt = 1psi. Where it might lose ground to the 502 is where 1mv =1amp. If this is the case I'd still prefer the extra protection of the 512 and use a hantek that has a 5 volt max for low level signals . Either way, I'd stick with the hscope software, the more I use it the more I like it
@danielkenkama57012 ай бұрын
@@manelishi13 oh really? I need to see that video... i got the impression the 502 and 512 were the same after watching the reviews on the 512, but I am a newbie when it comes to oscilloscopes and diagnostics with scopes and I'm sure your comparison video will be a big help for me. Thanks man.
@murauderАй бұрын
@@danielkenkama5701 the 502 has an input range selection of 16v, 8v, 4v, 1.6v where as the 512 has an input range selection of 32v, 16v, 8v, 3.3v. So they are sacrificing low range readings for higher range readings. Beyond that they are the same. I believe it is down to a different sensor package for each unit but everything else is the same.
@DJ-tn7vj2 ай бұрын
Thanks for the video. I have the same tools that you have and they work great.the pressure transducer is my go to and really was surprised how well it works
@manelishi132 ай бұрын
Your videos are one of the reasons I went with the hs502/512 and HScope. You make some good ones! Thank You!
@glenforehand2 ай бұрын
DJ I’m going to have to try this transducer bro. I have the snapon only. Where should I get it from bro?