Dangerous Electric Work Earthing Connection With the Busbar।Electric Work with Expert Electric Men

  Рет қаралды 176,185

Learn Pass Earn Professional

Learn Pass Earn Professional

Күн бұрын

Пікірлер: 58
@anothaparson
@anothaparson 3 ай бұрын
4 years later this piece of wood is still going... Excellent work!
@learnpassearnprofessional7467
@learnpassearnprofessional7467 2 ай бұрын
Thank you so much for your comments. Please share our videos to your friends and family. Like us support us for more.
@samuelkatherinediozarago7692
@samuelkatherinediozarago7692 3 жыл бұрын
For people who ask or want to know why this is ULTRA dangerous,here is your answer: Besides from Connections etc 1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance.. 2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black..
@elec3xn8tw0rx9
@elec3xn8tw0rx9 3 жыл бұрын
My mind and intuition whispers that this type of work requires a technically equipped professional who does the job. Reading, watching and educating yourself about earthing regulations in an hour will tell you so.
@avfczoff
@avfczoff 3 ай бұрын
How confident would you be going ahead & installing an earth rod? How do you know exactly where it can be installed? Surely asking National Grid to carry out a cat scan is the only way to be safe & confirm it’s an appropriate place for a rod to be installed?
@learnpassearnprofessional7467
@learnpassearnprofessional7467 2 ай бұрын
Thank you so much for your comments. Please share our videos to your friends and family. Like us support us for more.
@Blooppenheimer
@Blooppenheimer 2 жыл бұрын
4:12 mistake !: don't cut and use longer copper wire to increase the touching surface between wire anr the copper rod.
@learnpassearnprofessional7467
@learnpassearnprofessional7467 2 жыл бұрын
Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.
@Blooppenheimer
@Blooppenheimer 2 жыл бұрын
@@learnpassearnprofessional7467 i call every people in Turkiye right now to watch this video buddy. Hold tight
@KezzWelbrn
@KezzWelbrn 10 ай бұрын
its perfect to us the electricians.........
@learnpassearnprofessional7467
@learnpassearnprofessional7467 10 ай бұрын
Thank you
@mohammedwashimakram4513
@mohammedwashimakram4513 Жыл бұрын
Electric room to earth menhole how many meter fixed?
@learnpassearnprofessional7467
@learnpassearnprofessional7467 Жыл бұрын
Thank you
@ajaysharma9939
@ajaysharma9939 3 жыл бұрын
Hi, can I make the pipe earthing near my plastic water tank ? Will it be safe? Please reply
@Radhapzr
@Radhapzr 3 жыл бұрын
These guys do not know the basic theory of earthing in Electrical work.
@bobybehroozi5878
@bobybehroozi5878 10 ай бұрын
You should put this covered cable inside the anti-humid tube ( Foroplast tube.
@learnpassearnprofessional7467
@learnpassearnprofessional7467 7 ай бұрын
Thank you
@negrodjxijangelo6450
@negrodjxijangelo6450 4 жыл бұрын
how is this wrong, drive the rod in the ground connect the wire to main panel. seems simple
@ololmia226
@ololmia226 3 жыл бұрын
ধন্যবাদ
@stevenlawhon3695
@stevenlawhon3695 4 жыл бұрын
Rods are wrong diameter 5/8 or 3/4 needed. cable too small 6awg-2awg
@gulzarkhan8860
@gulzarkhan8860 4 жыл бұрын
This guy is not a Electrician.
@yahyakambi1191
@yahyakambi1191 4 жыл бұрын
May I please know why these earthing is wrong and dangerous.
@BarryBollox.
@BarryBollox. 4 жыл бұрын
This
@samuelkatherinediozarago7692
@samuelkatherinediozarago7692 3 жыл бұрын
@@BarryBollox. For people who ask or want to know why this is ULTRA dangerous,here is your answer: Besides from Connections etc 1-They do use only a single rod. For redundancy and safety as well as MOST importantly to Lower the resistance,you need 3 or 4 rods connected with each other.Also Dry soil =Higher resistance Wet=Less resistance.. 2-Not tested with earth resistance meter means it is a Good as a stake in ground which may not work at all!...You place 3 rods,connect resistance meter to them and test to see if it reads the guideline ohm/resistance. Else,this is just silly rod in the ground when someone is zapped and turned charcoal black...
@new-techengineering1684
@new-techengineering1684 2 жыл бұрын
@@samuelkatherinediozarago7692 thank you
@josephrobi6806
@josephrobi6806 Ай бұрын
5:53 ​​⁠@@samuelkatherinediozarago7692 copper😊The more rods the better myself I put two viper rods 6 feet apart 😊copper rod
@Presso99
@Presso99 Жыл бұрын
Misleading video, one rod is definitely not meeting the standards, minimum 2. When i started watching this video, i would expect them to measure the earth resistance using the earth resistance meter, if it meets 10 ohms and below, it is acceptable, of course the best is 5 ohms and below, the lower the better. If it doesn't meet, what is the next course of actions? This video doesn't show all these steps and recommendations such as how to improve the resistance by using GEM, copper mat and etc. One more thing, the ground wire clamping looks so flimsy, if someone dig the soil and accidentally pull the wire, the ground wire is slip through the grip. It is waste of time watching this.
@learnpassearnprofessional7467
@learnpassearnprofessional7467 Жыл бұрын
Thank you
@Selct.1238
@Selct.1238 4 жыл бұрын
how much deep in the earth muss the electrode conductor? thanks mate
@learnpassearnprofessional7467
@learnpassearnprofessional7467 4 жыл бұрын
Thanks dear for your comments. Please share our video to your friends and country. Like us comment us and subscribe us
@jimmykadaviparambil9622
@jimmykadaviparambil9622 4 жыл бұрын
Very bad connection , chance to loose anytime between rode and wire
@JamisKool
@JamisKool 4 жыл бұрын
This is terrible ! Extremely poor work with no understanding of electrical engineering standards.
@BarryBollox.
@BarryBollox. 4 жыл бұрын
Please explain.
@influxelectricalsolution7600
@influxelectricalsolution7600 3 жыл бұрын
🤭🙄🙄🙄cap and jacket are in proper way but not earthing
@cederbergfitness9797
@cederbergfitness9797 4 жыл бұрын
the green tape makes all that crap work much better ,how about using an electrician with experience
@dishantgauswami4808
@dishantgauswami4808 4 жыл бұрын
Ye konse engineer he electric to nai lag rahe
@kathiroliconnect3849
@kathiroliconnect3849 Жыл бұрын
Copper rod earth
@learnpassearnprofessional7467
@learnpassearnprofessional7467 Жыл бұрын
Thank you for your comments. Please share our videos to your friends and country. Like us, support us and subscribe to my channel.
@nuraddeenibrahim4039
@nuraddeenibrahim4039 3 жыл бұрын
Please add english subtitle
@learnpassearnprofessional7467
@learnpassearnprofessional7467 3 жыл бұрын
Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.
@SanmartinElectricidad-Obras
@SanmartinElectricidad-Obras 4 жыл бұрын
you need more tools...
@learnpassearnprofessional7467
@learnpassearnprofessional7467 4 жыл бұрын
Thank you so much for your comments. Please share our videos to your friends and country. Like us, comment us and subscribe to our channel.
@benjiedingding7226
@benjiedingding7226 2 жыл бұрын
Shuhada,, maskara,, siokol,,, Mafi mukh.
@learnpassearnprofessional7467
@learnpassearnprofessional7467 2 жыл бұрын
Thank you for your comments. Please share our videos to your friends and family and country. Like us, support us and dont forget to subscribe our channel.
@tahirriaz7780
@tahirriaz7780 3 жыл бұрын
Totally wrong
@learnpassearnprofessional7467
@learnpassearnprofessional7467 3 жыл бұрын
Thank you for your comments. Please share our videos to your friends and family. Like us, comments on our videos and subscribe our channel.
@dipueducation1490
@dipueducation1490 4 жыл бұрын
This is not a right method.
@BarryBollox.
@BarryBollox. 4 жыл бұрын
Please Explain
@piotrpiersa5459
@piotrpiersa5459 Жыл бұрын
it is not good job.
@learnpassearnprofessional7467
@learnpassearnprofessional7467 Жыл бұрын
Thank you
@piotrpiersa5459
@piotrpiersa5459 Жыл бұрын
@@learnpassearnprofessional7467 Look at my video, connect the earth electrode underground with a flat bar, not a cable.kzbin.info/www/bejne/aKXUiZynpM6EsJosi=Nw_muE2qu6W8lOVB
@mathewmm2193
@mathewmm2193 4 жыл бұрын
Unprofessional
@BarryBollox.
@BarryBollox. 4 жыл бұрын
Please explain
@chriscs9080
@chriscs9080 3 жыл бұрын
This is very professional . You just missed the point where he says it's a barbeque .
Маусымашар-2023 / Гала-концерт / АТУ қоштасу
1:27:35
Jaidarman OFFICIAL / JCI
Рет қаралды 390 М.
Jaidarman TOP / Жоғары лига-2023 / Жекпе-жек 1-ТУР / 1-топ
1:30:54
HOW TO PREFORM EARTH RESISTANCE TEST
14:36
rictor rictor
Рет қаралды 272 М.
Maintenance Free Earthing VS (Old) Conventional Earthing
5:13
Axis Electricals
Рет қаралды 26 М.
Stages of home grounding installation to avoid electrocution
5:22
Benbaslec12
Рет қаралды 1,3 МЛН
waste oil heating stove mini 3 in 1 ! Millions of people do not know this knowledge
15:19
Creative inventions LMTN
Рет қаралды 4,7 МЛН
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,6 МЛН