ive thought about this before it would be much better future proofing doing this, even with the old method with feeds at the light, you can send the neutral to the switch via 3 core, its so good it works both ways haha 💡 great video
@retrozmachine11897 күн бұрын
Taking the neutral to the switch in this way if you arrange things so the neutral is between the permanent live and switched wires would also address continually glowing or blinking lights when the switch is off too (capacitive coupling)
@lunavx10 күн бұрын
Why haven't they made a ceiling rose with wago holders instead of those brass screws yet...
@GaryHall-he2ff8 күн бұрын
Spoke to Wago development engineer at installer show earlier in the year. He tried to get a Wago ceiling rose off the ground. He needed a partner and none of the big accessory names were interested due to the high end cost of the product. I pointed out that it would be an installer choice and a balance between cost and labour time. Another aspect is that as you get older and wear bifocals you are looking through the wrong part of the lens when wiring ceiling fittings and a Wago fitting would help with this.
@billdoodson42328 күн бұрын
I think that if you wanted lever type Wagos, even the smallest 221's would be too big. Although I totally agree with you, they'd be so much better, I really hate ceiling roses. These days I try to fit Quickwire connectors of some type when doing ceiling lights.
@lunavx8 күн бұрын
@@billdoodson4232 I tend to do loop in loop out in a wago box and bring a tail out to the rose now
@billdoodson42327 күн бұрын
@@lunavx Yes, did that last week, but used one of those Quickfix JB's, I like the way they hold in the 221 Wago's, better than the actual Wago boxes.
@kevinlawes5916 күн бұрын
@@lunavx No flys on us 2! 😉👍🏻👍🏻
@scottneilson74289 күн бұрын
Hi, great video, very clear. In your demo, perhaps for clarity, you have omitted the looping twin and cpc to the next room/zone. Let's assume this would have been in the switch, looping from switch to switch. That's the way I would do it and I like the concept of the 3c and cpc to the light fitting. The only downside is where the circuit might be 2 way, and it can start to get a bit busy at the switch, a deeper box defo gonna help.
@TonySmall-w3c10 күн бұрын
Superb, everything you do is presented so clearly, thank you
@GSHElectrical10 күн бұрын
@@TonySmall-w3c thanks for the positive comment
@daves402610 күн бұрын
Really nice explanation thanks
@Wiltshire-observerКүн бұрын
Having the permanent live and neutral with earth at the light switch, is great if you want to install wall lights. I did this in a new build property, albeit the walls were all stud walls.
@steve1121110 күн бұрын
Did this on a rewire recently, but did it the other way round, did the old method and just had a 3core and cpc down to the switch...
@GSHElectrical10 күн бұрын
Nice
@tomc55010 күн бұрын
Done that as well, allows for smart control in switch with deep back box as well but never thought of this. Obvious when think about it, appreciated, thank you.
@barrydoherty6368 күн бұрын
Great video, well done.
@GSHElectrical8 күн бұрын
Thank you very much!
@idriselmi41018 күн бұрын
Cheers gary
@GSHElectrical8 күн бұрын
Thanks
@Bari_Khan_CEng_CMarEng9 күн бұрын
Garry what the hell! Why are we now not doubling over the conductors for a ceiling rose? After all the times you've advocated for it!
@NaeemKhan-kc9bx8 күн бұрын
Great video
@GSHElectrical8 күн бұрын
Thanks!
@shanebyrne640410 күн бұрын
Great idea
@richardskinner20807 күн бұрын
What's the purpose of trying to "deneutralise" black? Definitely seems more logical to use it as neutral to me. Having live (albeit switched) on a black cable only seems to bring more risk of confusion.
@alfredbatchelor19548 күн бұрын
For give me, but didn’t we have a ring circuit originally, before we joined EU. Where you had a live and neutral loop? Is this not a case of the EU got it wrong because the U.K. was years ahead of Europe, but had adopted a lower standard because of ONORM’s!
@sabudjed113511 күн бұрын
Thanks
@GSHElectrical10 күн бұрын
No problem
@barrygray969311 күн бұрын
Clever
@andysims490610 күн бұрын
Just a word of warning. Although you have done it the correct way. Its not uncommon to see other people use the black for neutral and not the grey. I was on a job the other day done by a so called NIC professional house basher and he had used the black on smoke alarms for the neutral. The point is .if in doubt always check and test
@GSHElectrical10 күн бұрын
Thanks for your thoughts and experiences
@samoldman577610 күн бұрын
Nothing wrong with black as neutral. As long as its sleeved either end you can use what you want (just not an earthing conductor)
@johnadams197610 күн бұрын
wish my house had been wired like this!!! I've swapped 3 switches over to NSPanelPro devices.... running the neutral was a pain!!!
@rafique4704 күн бұрын
What is advantage of using two plate circuit
@mralan65211 күн бұрын
Hi, what is the wire stripper you are using instead of the knife? Thanks
@rayc150310 күн бұрын
Google 'automatic twin and earth wire stripper'. There are plenty of different variants, same tool just branded differently.
@shamrockshore630810 күн бұрын
Why not just use t+e plus a single brown for either the feed or switchwire?
@SparkyMarky-s8b8 күн бұрын
Lovely idea and something i would do in my own home. However, while we are wasting money, why not bring all cables to a central point? Then you can choose what's live, neutral or switched. Future proofing is a great idea, but few customers value it over cost, and while you are morally doing the right thing, you have lost out to the quote using suface trunking and pendulum fittings.
@simonmac42918 күн бұрын
While you are at it you could make them all 4mm* and terminate them in a giant patch panel like a CAT5 install. /S (You never know someone might want to install a projector from a ceiling rose in the future)
@alexkemp616511 күн бұрын
Good idea but might get a bit cramped with downlight circuits
@LeeWelch-n8l7 күн бұрын
Firsly, the customer must agree, unless it is a new build, especially if there is extra costs for doing this.
@MrFiver111110 күн бұрын
The cheekiest way would be to remove the CPC sleeve for a brown or grey sleeve and use that as the switching line and the insulated brown as the permanent live, but thats very illegal 😅
@fjspicer110 күн бұрын
I know that this is only a demo but that plastic box needs to be 25mm deep. I always install round plastic conduit and 25 mm deep metal boxes for flush light switches
@andysims490610 күн бұрын
Totally agree. That’s the way I would do it ,but if the chase is not to deep I would use oval conduit
@simonmac42918 күн бұрын
Does anyone make a twin brown + blue cable? (Though ideally a brown / brown with white trace and blue, with the trace to aid in installation)
@stevenhopkins292510 күн бұрын
the problem is that the DIYers are back to messing up the colours again. Loop in is exactly the same issues but saves all those extra connections at the switch.
@darrenpodger72948 күн бұрын
Where does 3 core connect in consumer unit
@ases500410 сағат бұрын
Twin and Earth from the consumer unit to the first switch in the circuit, then 3 core from switch to ceiling rose.
@stuartandrews43449 күн бұрын
Was taught this method 40 years ago to use 3 core +E cable by a brilliant instructor at college.
@GrahamCottrell-t5s7 күн бұрын
Why not wire it in 3 plate and just run a 3 core down to the switch
@wayneself731910 күн бұрын
Dam you are only just doing this........
@colinsmith62802 күн бұрын
this is a old idea revived it still in place on old house's not modernised
@gadgetman3610 күн бұрын
If the video is over 3 minutes long it should be horizontal, not vertical. This is neither a short, nor a long form video. I'm sorry but I'm not watching it.
@MS-Patriot210 күн бұрын
We’re gutted.
@barrygroves204610 күн бұрын
😂 Bet they are worried now your not watching.
@sean89n10 күн бұрын
Lol
@peterandrewwilson97610 күн бұрын
It simulates a short-arse student watching from behind two tall students; viewing the lecturer from between their heads.
@ases500410 сағат бұрын
You probably spent longer constructing and editing a comment saying you're not watching the video than watching it 😂
@octymocty13210 күн бұрын
And this is why you jave accidents though we were harmonised obvsioly not. And obvious its been doen to confuse ever one again as in my feild brown and gry is live and blk is neutrall . Just trying to make it easy for no elec iddiots to say theyer electrical
@keoghrichard198810 күн бұрын
It’s actually common practice NOT to use the black as a neutral to reduce confusion, as black is now a colour used for Line conductor