Lighting Circuit - New Build Method with a Twist

  Рет қаралды 16,662

GSH Electrical

GSH Electrical

Күн бұрын

Пікірлер: 63
@nialbuckley5785
@nialbuckley5785 10 күн бұрын
ive thought about this before it would be much better future proofing doing this, even with the old method with feeds at the light, you can send the neutral to the switch via 3 core, its so good it works both ways haha 💡 great video
@retrozmachine1189
@retrozmachine1189 7 күн бұрын
Taking the neutral to the switch in this way if you arrange things so the neutral is between the permanent live and switched wires would also address continually glowing or blinking lights when the switch is off too (capacitive coupling)
@lunavx
@lunavx 10 күн бұрын
Why haven't they made a ceiling rose with wago holders instead of those brass screws yet...
@GaryHall-he2ff
@GaryHall-he2ff 8 күн бұрын
Spoke to Wago development engineer at installer show earlier in the year. He tried to get a Wago ceiling rose off the ground. He needed a partner and none of the big accessory names were interested due to the high end cost of the product. I pointed out that it would be an installer choice and a balance between cost and labour time. Another aspect is that as you get older and wear bifocals you are looking through the wrong part of the lens when wiring ceiling fittings and a Wago fitting would help with this.
@billdoodson4232
@billdoodson4232 8 күн бұрын
I think that if you wanted lever type Wagos, even the smallest 221's would be too big. Although I totally agree with you, they'd be so much better, I really hate ceiling roses. These days I try to fit Quickwire connectors of some type when doing ceiling lights.
@lunavx
@lunavx 8 күн бұрын
@@billdoodson4232 I tend to do loop in loop out in a wago box and bring a tail out to the rose now
@billdoodson4232
@billdoodson4232 7 күн бұрын
@@lunavx Yes, did that last week, but used one of those Quickfix JB's, I like the way they hold in the 221 Wago's, better than the actual Wago boxes.
@kevinlawes591
@kevinlawes591 6 күн бұрын
@@lunavx No flys on us 2! 😉👍🏻👍🏻
@scottneilson7428
@scottneilson7428 9 күн бұрын
Hi, great video, very clear. In your demo, perhaps for clarity, you have omitted the looping twin and cpc to the next room/zone. Let's assume this would have been in the switch, looping from switch to switch. That's the way I would do it and I like the concept of the 3c and cpc to the light fitting. The only downside is where the circuit might be 2 way, and it can start to get a bit busy at the switch, a deeper box defo gonna help.
@TonySmall-w3c
@TonySmall-w3c 10 күн бұрын
Superb, everything you do is presented so clearly, thank you
@GSHElectrical
@GSHElectrical 10 күн бұрын
@@TonySmall-w3c thanks for the positive comment
@daves4026
@daves4026 10 күн бұрын
Really nice explanation thanks
@Wiltshire-observer
@Wiltshire-observer Күн бұрын
Having the permanent live and neutral with earth at the light switch, is great if you want to install wall lights. I did this in a new build property, albeit the walls were all stud walls.
@steve11211
@steve11211 10 күн бұрын
Did this on a rewire recently, but did it the other way round, did the old method and just had a 3core and cpc down to the switch...
@GSHElectrical
@GSHElectrical 10 күн бұрын
Nice
@tomc550
@tomc550 10 күн бұрын
Done that as well, allows for smart control in switch with deep back box as well but never thought of this. Obvious when think about it, appreciated, thank you.
@barrydoherty636
@barrydoherty636 8 күн бұрын
Great video, well done.
@GSHElectrical
@GSHElectrical 8 күн бұрын
Thank you very much!
@idriselmi4101
@idriselmi4101 8 күн бұрын
Cheers gary
@GSHElectrical
@GSHElectrical 8 күн бұрын
Thanks
@Bari_Khan_CEng_CMarEng
@Bari_Khan_CEng_CMarEng 9 күн бұрын
Garry what the hell! Why are we now not doubling over the conductors for a ceiling rose? After all the times you've advocated for it!
@NaeemKhan-kc9bx
@NaeemKhan-kc9bx 8 күн бұрын
Great video
@GSHElectrical
@GSHElectrical 8 күн бұрын
Thanks!
@shanebyrne6404
@shanebyrne6404 10 күн бұрын
Great idea
@richardskinner2080
@richardskinner2080 7 күн бұрын
What's the purpose of trying to "deneutralise" black? Definitely seems more logical to use it as neutral to me. Having live (albeit switched) on a black cable only seems to bring more risk of confusion.
@alfredbatchelor1954
@alfredbatchelor1954 8 күн бұрын
For give me, but didn’t we have a ring circuit originally, before we joined EU. Where you had a live and neutral loop? Is this not a case of the EU got it wrong because the U.K. was years ahead of Europe, but had adopted a lower standard because of ONORM’s!
@sabudjed1135
@sabudjed1135 11 күн бұрын
Thanks
@GSHElectrical
@GSHElectrical 10 күн бұрын
No problem
@barrygray9693
@barrygray9693 11 күн бұрын
Clever
@andysims4906
@andysims4906 10 күн бұрын
Just a word of warning. Although you have done it the correct way. Its not uncommon to see other people use the black for neutral and not the grey. I was on a job the other day done by a so called NIC professional house basher and he had used the black on smoke alarms for the neutral. The point is .if in doubt always check and test
@GSHElectrical
@GSHElectrical 10 күн бұрын
Thanks for your thoughts and experiences
@samoldman5776
@samoldman5776 10 күн бұрын
Nothing wrong with black as neutral. As long as its sleeved either end you can use what you want (just not an earthing conductor)
@johnadams1976
@johnadams1976 10 күн бұрын
wish my house had been wired like this!!! I've swapped 3 switches over to NSPanelPro devices.... running the neutral was a pain!!!
@rafique470
@rafique470 4 күн бұрын
What is advantage of using two plate circuit
@mralan652
@mralan652 11 күн бұрын
Hi, what is the wire stripper you are using instead of the knife? Thanks
@rayc1503
@rayc1503 10 күн бұрын
Google 'automatic twin and earth wire stripper'. There are plenty of different variants, same tool just branded differently.
@shamrockshore6308
@shamrockshore6308 10 күн бұрын
Why not just use t+e plus a single brown for either the feed or switchwire?
@SparkyMarky-s8b
@SparkyMarky-s8b 8 күн бұрын
Lovely idea and something i would do in my own home. However, while we are wasting money, why not bring all cables to a central point? Then you can choose what's live, neutral or switched. Future proofing is a great idea, but few customers value it over cost, and while you are morally doing the right thing, you have lost out to the quote using suface trunking and pendulum fittings.
@simonmac4291
@simonmac4291 8 күн бұрын
While you are at it you could make them all 4mm* and terminate them in a giant patch panel like a CAT5 install. /S (You never know someone might want to install a projector from a ceiling rose in the future)
@alexkemp6165
@alexkemp6165 11 күн бұрын
Good idea but might get a bit cramped with downlight circuits
@LeeWelch-n8l
@LeeWelch-n8l 7 күн бұрын
Firsly, the customer must agree, unless it is a new build, especially if there is extra costs for doing this.
@MrFiver1111
@MrFiver1111 10 күн бұрын
The cheekiest way would be to remove the CPC sleeve for a brown or grey sleeve and use that as the switching line and the insulated brown as the permanent live, but thats very illegal 😅
@fjspicer1
@fjspicer1 10 күн бұрын
I know that this is only a demo but that plastic box needs to be 25mm deep. I always install round plastic conduit and 25 mm deep metal boxes for flush light switches
@andysims4906
@andysims4906 10 күн бұрын
Totally agree. That’s the way I would do it ,but if the chase is not to deep I would use oval conduit
@simonmac4291
@simonmac4291 8 күн бұрын
Does anyone make a twin brown + blue cable? (Though ideally a brown / brown with white trace and blue, with the trace to aid in installation)
@stevenhopkins2925
@stevenhopkins2925 10 күн бұрын
the problem is that the DIYers are back to messing up the colours again. Loop in is exactly the same issues but saves all those extra connections at the switch.
@darrenpodger7294
@darrenpodger7294 8 күн бұрын
Where does 3 core connect in consumer unit
@ases5004
@ases5004 10 сағат бұрын
Twin and Earth from the consumer unit to the first switch in the circuit, then 3 core from switch to ceiling rose.
@stuartandrews4344
@stuartandrews4344 9 күн бұрын
Was taught this method 40 years ago to use 3 core +E cable by a brilliant instructor at college.
@GrahamCottrell-t5s
@GrahamCottrell-t5s 7 күн бұрын
Why not wire it in 3 plate and just run a 3 core down to the switch
@wayneself7319
@wayneself7319 10 күн бұрын
Dam you are only just doing this........
@colinsmith6280
@colinsmith6280 2 күн бұрын
this is a old idea revived it still in place on old house's not modernised
@gadgetman36
@gadgetman36 10 күн бұрын
If the video is over 3 minutes long it should be horizontal, not vertical. This is neither a short, nor a long form video. I'm sorry but I'm not watching it.
@MS-Patriot2
@MS-Patriot2 10 күн бұрын
We’re gutted.
@barrygroves2046
@barrygroves2046 10 күн бұрын
😂 Bet they are worried now your not watching.
@sean89n
@sean89n 10 күн бұрын
Lol
@peterandrewwilson976
@peterandrewwilson976 10 күн бұрын
It simulates a short-arse student watching from behind two tall students; viewing the lecturer from between their heads.
@ases5004
@ases5004 10 сағат бұрын
You probably spent longer constructing and editing a comment saying you're not watching the video than watching it 😂
@octymocty132
@octymocty132 10 күн бұрын
And this is why you jave accidents though we were harmonised obvsioly not. And obvious its been doen to confuse ever one again as in my feild brown and gry is live and blk is neutrall . Just trying to make it easy for no elec iddiots to say theyer electrical
@keoghrichard1988
@keoghrichard1988 10 күн бұрын
It’s actually common practice NOT to use the black as a neutral to reduce confusion, as black is now a colour used for Line conductor
@GSHElectrical
@GSHElectrical 10 күн бұрын
Nice comment… thanks
@jeremykemp3782
@jeremykemp3782 8 күн бұрын
Great idea
How Lighting Circuits Were Wired - Old Cable Colours Explained
4:53
GSH Electrical
Рет қаралды 1,7 М.
10 Mistakes EVERYONE Makes When Doing DIY Electrics!💥
11:56
Artisan Electrics
Рет қаралды 226 М.
Players push long pins through a cardboard box attempting to pop the balloon!
00:31
Lazy days…
00:24
Anwar Jibawi
Рет қаралды 6 МЛН
FOREVER BUNNY
00:14
Natan por Aí
Рет қаралды 32 МЛН
BIGGEST DIY Mistakes Joining Cables
8:52
The Diligent DIYer
Рет қаралды 309 М.
The Worst DIY Solar Install I’ve Ever Seen! 😨
9:37
Artisan Electrics
Рет қаралды 54 М.
Glanding a 630A 3 phase supply | REC09
25:46
Residual Electrical
Рет қаралды 110 М.
5 Biggest DIY Mistakes Wiring a Socket
6:02
The Diligent DIYer
Рет қаралды 817 М.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Рет қаралды 615 М.
HOW TO PATCH UP A CHASE
11:22
On The Trowel
Рет қаралды 55 М.
Players push long pins through a cardboard box attempting to pop the balloon!
00:31