Low Oil Troubleshoot RTAA Chiller

  Рет қаралды 14,149

HVACTIME

HVACTIME

Күн бұрын

Walking hvac technician through a low oil troubleshoot of a Trane RTAA air cooled chiller.
Get 8% off at TruTech Tools with promo HVACTIME
www.trutechtools.com/?ApplyPr...
Get tech support, training, and the Tech Blog at hvactimetx.com
You can contact me at Hvactimetx@gmail.com
Support my COFFEE problem through,
venmo.com/code?user_id=316085...
Zelle @ Hvactimetx@gmail.com

Пікірлер: 49
@dfwhvac
@dfwhvac Жыл бұрын
I’ve been in the field for 10 years , the last 5 working on chillers air and water cooled comfort cooling and process and boilers. You’re my favorite chiller related channel and really appreciate the time you put into your videos . I have gone through the process of creating and editing a few videos myself , so I know how much time and effort and it takes . Just wanted to say I appreciate the time you put into these while already having a home life and a full time job , all the intention to spread knowledge within our field
@wata_laf
@wata_laf 5 күн бұрын
Favorite chiller channel! Holden just knows sooooo much. Thank u for these videos
@ryanmalin
@ryanmalin Жыл бұрын
pretty neat trick with the sight glass to find the oil level! Thanks for sharing
@codyalexander9470
@codyalexander9470 Жыл бұрын
I have absolutely no clue what yall are taking about but it's pretty interesting.
@Arzdnej
@Arzdnej Жыл бұрын
Those Trane chillers... Always expecting surprise from it. The first time I got touch with one was when I had no idea that there's an oil cooler integrated with condenser 😂 And taking infrared camera for service too, because of this oil separator and compressor having no sight glass 😅
@HVAC-prochiller
@HVAC-prochiller Жыл бұрын
My friend. I bought transparent hoses on Aliexpress 5 years ago. Re-equipped in the hydraulic press. I have a supply of such hoses. With them I go to Chiller. But I still don't understand Trane's designers. In total, you need to cut three or two glasses into the oil separator. RTAA is the best model for me. and the 22nd refrigerant is the best refrigerant for high evaporation temperatures.
@b.d.1409
@b.d.1409 Жыл бұрын
You a sharp fella!
@OramWerd
@OramWerd Жыл бұрын
Very smart idea with the sight glass on the hoses. I will for sure be using that in the future when in a pinch.
@jweschler
@jweschler Жыл бұрын
That’s actually in the IOM in the back under the maintenance section.
@mrbyamile6973
@mrbyamile6973 2 ай бұрын
They mak a nice tall 8 or 10" tall sight glass that's similar with 1/4" flair fittings on it that make it easier to identify the level. I used one once, unfortunately it wasn't mine so I'm typically using the method he shows with the little sight glass.
@thesilentonevictor
@thesilentonevictor Жыл бұрын
Good catch on this tricky one
@rodgraff1782
@rodgraff1782 Жыл бұрын
I’ve worked on this model before. Did the oil level thing. Wish they would have put in two sight glasses, one at the low limit and one at the high. Would be less of a PITA. Did you find out why the level was low, and where the oil went? On the unit we had, one circuit was flat on delivery, and two compressor processor boards were bad.
@jamesfitzsimmons381
@jamesfitzsimmons381 Жыл бұрын
You’re one smart guy
@jameshendry9906
@jameshendry9906 Жыл бұрын
My teacher used you approach video for school last night lol. Thanks for the knowledge you are passing on.
@HVACTIME
@HVACTIME Жыл бұрын
What school you go to?
@jameshendry9906
@jameshendry9906 Жыл бұрын
It is call AACP. Association of Air Conditions Professionals. It a 4 year program and we were going over chillers and the different type.
@RSBot2jar
@RSBot2jar Жыл бұрын
Interesting video!
@jasonjohnsonHVAC
@jasonjohnsonHVAC Жыл бұрын
A few months ago i bought a Hikmicro Pocket2 thermal camera....it is pretty dang nice and has good resolution. I also have the Flir One Pro which is also pretty decent...but i like the Hikmicro over the Flir
@REFEREEMOUSE
@REFEREEMOUSE Жыл бұрын
Nice catch. My question is about the oil. There are no oil leaks and things of that nature since you didn’t say it. Do you think the oil is trapped in the evap, it had to go somewhere? I heard you say you changed the compressor.
@TimTakacs
@TimTakacs 2 ай бұрын
I worked for Trane and their RTAA - RTAC units. I've found the oil filter to be culprit very often. Oil would be moved out of the compressor into the Cond. Barrel. Replace the the oil filter and dryer and this problem will disappear.
@sterlingarcher46
@sterlingarcher46 Жыл бұрын
The whole temperature difference i didn't quite grasp because I'm not used to this type of oil management, I'm gonna watch again and try and do some research. Bitzer has an integrated oil separator which seems to work pretty well .
@TheMarinac1
@TheMarinac1 9 ай бұрын
We use transparent hoses and works very well.
@Amorbellum
@Amorbellum 7 күн бұрын
Where do you get transparent hoses!!!??
@JOSERization
@JOSERization Жыл бұрын
Where can we get one of those sight glasses on your hoses ?
@user-dx4bp8rf1l
@user-dx4bp8rf1l 4 ай бұрын
Cómo quisiera saber hablar inglés para seguir de cerca las clases de este excelente maestro
@a.bminhas6381
@a.bminhas6381 Жыл бұрын
Sir kindly make a video of how the system pump down the trane chiller RTAC
@mallkomoha6823
@mallkomoha6823 2 ай бұрын
Please can send link for that side glass?
@abduljabar1757
@abduljabar1757 Жыл бұрын
Pls explain high motor temp 2
@JaromKizhakkanudan
@JaromKizhakkanudan 6 ай бұрын
Please replay any body. My chiller RTAH211, alaram circuit shutdown has occurred.?
@isaacsanchez3966
@isaacsanchez3966 Жыл бұрын
Love your videos they are a big help. How can anyone get a hold of you
@HVACTIME
@HVACTIME Жыл бұрын
I offer tech support at my website at hvactimetx.com/techsupport You can email techsupport@hvactimetx.com
@HVAC-prochiller
@HVAC-prochiller Жыл бұрын
👍👍👍
@Eighty8Fitter
@Eighty8Fitter 2 ай бұрын
Is it weird that I can pick out the CGAM in the background? 😆
@keithbyrnes5989
@keithbyrnes5989 Жыл бұрын
Where did the oil go? Is it traped in the system somewhere or leak out?
@HVACTIME
@HVACTIME Жыл бұрын
This circuit has had several repairs due to leaks and other component failures including a compressor change out within the last year. Our estimation is that during the duration of all of these events it led to the oil level getting too low in the system.
@kehindefatai3830
@kehindefatai3830 3 ай бұрын
Pls when checking the oil level will the unit will still be on or off
@HVACTIME
@HVACTIME 3 ай бұрын
It has to be off.
@rm20235
@rm20235 Ай бұрын
So where did the oil go? Oil loss over the years of checking the level and random repairs?
@HVACTIME
@HVACTIME Ай бұрын
And a compressor replacement. New compressor was shipped dry but additional oil was never added. Old compressor took a large quantity of oil with it.
@rm20235
@rm20235 Ай бұрын
@@HVACTIME that’ll do it!
@robshuey6881
@robshuey6881 6 ай бұрын
Was the chiller low on oil, or was it trapped in the evaporator?
@HVACTIME
@HVACTIME 6 ай бұрын
To verify it wasn't trapped. We were able to get the circuit to fully stage and run for a few days. Even after adding oil we made a return trip to ensure that the levels did not increase.
@jordanpatin2736
@jordanpatin2736 Жыл бұрын
Where did the oil go though? Does it mean there's a leak?
@HVACTIME
@HVACTIME Жыл бұрын
This circuit has had several repairs due to leaks and other component failures including a compressor change out within the last year. Our estimation is that during the duration of all of these events it led to the oil level getting too low in the system.
@jordanpatin2736
@jordanpatin2736 Жыл бұрын
@@HVACTIME ok thank you!
@rajanvishwakarma8171
@rajanvishwakarma8171 11 ай бұрын
Rtad 125 Low superhit alarm how to fix sir
@rajanvishwakarma8171
@rajanvishwakarma8171 11 ай бұрын
Gas suction pressure 50 r134
@HEFTYLEFTY303
@HEFTYLEFTY303 Жыл бұрын
Just a thought I carry A clear hose for those checks
@HVACTIME
@HVACTIME Жыл бұрын
We do too, the one we had on site failed at the connector so had to swop over.
RTAA 400 ton chiller Piston Replacement
13:12
John Hoyer
Рет қаралды 60 М.
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 14 МЛН
МАМА И STANDOFF 2 😳 !FAKE GUN! #shorts
00:34
INNA SERG
Рет қаралды 4,4 МЛН
Пробую самое сладкое вещество во Вселенной
00:41
Khó thế mà cũng làm được || How did the police do that? #shorts
01:00
Trane RTAC Leak Repair + Oil Filter Part 1
19:57
DFW HVAC
Рет қаралды 11 М.
Trane chiller EXV  installation
4:25
HVAC Tips&Tricks
Рет қаралды 7 М.
Tiny Part caused BIG chiller problem
8:08
HVACTIME
Рет қаралды 13 М.
Trane sensor bind in step by step TechView
6:57
Robles
Рет қаралды 13 М.
First 5 Steps to Troubleshoot Chillers
12:57
HVACTIME
Рет қаралды 3,2 М.
Trane Chiller Rtac 300 Ton Complete review! Air cooled chiller! Hvac System hindi/urdu
9:39
HVAC INFORMATION & KNOWLEDGE SHARING
Рет қаралды 17 М.
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 14 МЛН