Making a Proper Split-bolt Connection. Aka-Bugs

  Рет қаралды 69,842

Craig Michaud- Electrical Instructor

Craig Michaud- Electrical Instructor

Күн бұрын

In this video I show how to make a proper split-bolt connection. This is known as Bugging the wire. It is important to remember that not everyone does it the same. You can use this connection for Copper and Aluminum. I show how to make a #2 bug splice and a 4/0 bug splice with two different type of bugs.
Dont forget to email sparkyinstructor@gmail.com and ask to be on my Newsletter list!!
Thanks for watching!

Пікірлер: 106
@RB-xv4si
@RB-xv4si 5 жыл бұрын
Nice splices. Reminds me how labor intensive bugging is. I used IPCs (insulation piercing connectors) a lot when I was doing solar and tapping onto the mains. They save a lot of time because you don’t have to strip the wire...and when you’re done tightening the bolt, you don’t need to wrap it with any splicing tape. Quite an awesome connector.
@teardowniscool
@teardowniscool 3 жыл бұрын
Excellent job as always Craig !
@eldorado96
@eldorado96 3 жыл бұрын
I didn't mind the Channelocks so much, but I was real concerned about using the stiffness of the wire to provide the resistance for tightening. The wire got bent over and then re-straightened. I would never introduce that kind of strain and potential fatigue at a splice location like that. If you must use Channelocks, use two of them to grip both components of the split bolt instead, or one Channelock to grip the body and a proper wrench for the nut.
@mathman0101
@mathman0101 3 жыл бұрын
Seriously brilliant and well explained Craig.
@kyled3044
@kyled3044 3 жыл бұрын
I see two issues with your parallel connection on the first split bolt. #1- when tightening the bolt, you should use a backing wrench, you can see when it started to get tight it started bending the wire, which you then straightened causing undue stress. Not a huge deal but integrity of the wire is key. #2- You stated a "waterproof connection" using the rubber tape, however you did not use rubber tape in between the 2 wires so there is no seal to keep water from entering at the bottom in between the 2 wires. Placing rubber tape in between the 2 wires and the wrapping that around both wires twice before wrapping the lug would prevent water intrusion.
@gianniforte100
@gianniforte100 2 жыл бұрын
Hundred electricians analogy is sooo true. I've worked with hundreds, each time you work with a new one ,especially a new company, you will be being re schooled on everything from walking to twisting wire nuts. Wether your a master or apprentice. For a service I use antioxidant and buy 3 rolls of both tapes and try to use most of it. Depends alot on how awkward/dangerous of a position I am in on the ladder and how tired my arm is getting honestly lol atleast half roll of thick rubber and try for full roll of regular tape which I try to get real rubber hi quality for as well. I was taught full roll of each but over the years realizing that is over kill but seriously that stuff is going to be blowing around in the wind and all kinds of weather for who knows how long. It's worth the 30 bucks in tape and a little extra time for piece of mind...to me.
@danielhoughtelling9721
@danielhoughtelling9721 2 жыл бұрын
There is an industry standard. 1. Use antioxidant/deox to keep the conductors from plating due to electrolysis. 2. Use a wrenches and a hammer to insure the conductors compress fully. 3. Use camber tape to protect the tape from the bolt. 4. Wrap with rubber. 5. Wrap with a high quality electrical tape. If you want a fast connection, use Polaris pre-insulated connectors. There aren't hundreds of ways to do it. There are only two. The right war or the HACK way.
@miltonnegron65
@miltonnegron65 3 жыл бұрын
Excellent video !!!
@jeromebarrett8016
@jeromebarrett8016 4 жыл бұрын
Thanks for sharing this with me, I've only done one so far . I am a electrician helper so I did as I was instructed by a licensed electrician and it turned out bad . I've never seen him use that rubber tape, glad to see how to use it. God Bless You.
@commercialelectrician133
@commercialelectrician133 3 жыл бұрын
Great video very informative
@arthurharrison1345
@arthurharrison1345 2 жыл бұрын
Thanks for a great video.
@buffmin
@buffmin 4 жыл бұрын
I can tell that you are a probably a really good instructor. Nice job! Thanks.
@mahdavimail
@mahdavimail 4 жыл бұрын
Thanks for video . Awsome👍
@jasonparkinson7621
@jasonparkinson7621 5 жыл бұрын
Informative, thanks.
@STUFFDO-je9cl
@STUFFDO-je9cl 4 жыл бұрын
This is gold. Thank you so much for sharing your knowledge.
@Dennis-cy4wv
@Dennis-cy4wv 4 жыл бұрын
In the small company I was employed at, we put a layer of electrical tape on first, then our rubber/putty tape, then finish with electrical tape. This allows us to reuse our split bolts if need be. Getting the tape of isn't to difficult when no rubber is stretched around the threads.
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 4 жыл бұрын
That is a great point!! It is always nice to hear how others do it!! So many different ways of doing the same job in electrical. Depending on what state or country. Thanks for sharing the tip!! CM
@JH-ms3ny
@JH-ms3ny 4 жыл бұрын
This is how I was taught, except the first layer of electrical tapes goes on sticky side out, so if you ever have to service it, there won’t be any sticky residue from heat.
@garbo8962
@garbo8962 Жыл бұрын
Like to have a dollar every time I had to reuse a bug that had rubber taped melted onto it. We used garnished Cambridge take first then scotch 33 tape and UT was usually easy to reuse bugs.
@adammorgan9304
@adammorgan9304 Жыл бұрын
We used the varnish tape or Cambric tape. Whatever you wanna call it. Then 33 then the rubber tape then 33 again
@ronbonick4265
@ronbonick4265 Жыл бұрын
Thanks Bro even the simple stuff I learned me something new
@howtodoelectrical200
@howtodoelectrical200 3 жыл бұрын
Very nice bro I appreciate you sharing
@howardb1922
@howardb1922 Жыл бұрын
Aplus presentation. Thanks
@otm646
@otm646 4 жыл бұрын
Reaching for the channel locks really hurt. Use the properly sized wrench, or an adjustable wrench if you have to. Never channel locks.
@yousuckathomerepair7301
@yousuckathomerepair7301 3 жыл бұрын
Can I use these to splice the 100 amp aluminum wires going from the outside service panel to the inside panel of a trailer? The splice will be inside the 200 amp service box outside. Just need to extend the aluminum wire to reach a breaker because the bottom lugs got seized up for some reason.
@Alfredoh212
@Alfredoh212 5 жыл бұрын
Thanks man
@SLi-pr8vv
@SLi-pr8vv 2 жыл бұрын
yes. helped me. next step I need to buy the bugs and the rubber.
@blakeywsr59
@blakeywsr59 Жыл бұрын
Awesome, thank you.
@rickdeboi3407
@rickdeboi3407 5 жыл бұрын
Thank you for sharing that Craig!
@Ninjaguides
@Ninjaguides 5 жыл бұрын
Nice job
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 5 жыл бұрын
Thank you for watching!!! CM
@paulgiza3018
@paulgiza3018 Жыл бұрын
Thank you good job
@alejandrovelasco9573
@alejandrovelasco9573 5 жыл бұрын
Nice informative video Sir. I have a suggestion. I think it is better to demonstrate it to simulate an actual work scenario.Like Your on a ladder wearing your PPE.
@wizard3z868
@wizard3z868 3 жыл бұрын
the only he was missing was his sunglasses and i didnt see any sun?🤷‍♀️😜
@robertmayan4342
@robertmayan4342 5 жыл бұрын
Great job !
@stargazer8085
@stargazer8085 5 жыл бұрын
excellent
@jrr2016
@jrr2016 3 жыл бұрын
Can I use ring connectors crimped to each wire and then attach them with a bolt an nut instead? e.g., if you need to connect three or more wires together it is harder with a split bolt. Thanks for the video!
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 6 ай бұрын
Thanks COOP ...
@edwinaragon4878
@edwinaragon4878 3 жыл бұрын
Can this also be used to extend 6 gauge ground wire? I have a ground bond wire in side my walls going to my gas water heater that is coming from a ground rod. I want to install windows and this wire is in the way so I want to reroute the wire
@nelsondog100
@nelsondog100 4 жыл бұрын
Is that actually rubber tape or is it self-fusing silicone tape?
@WiliamBennettwildarbennett
@WiliamBennettwildarbennett 3 жыл бұрын
Yes these are great connections, but would ask that you demonstrate properly torqued tightening. I personally have to go back and retighten connectors. And then properly TORQUED them. Also I have to say that "BURNDY" LINE TAP S are a more expensive option But you don't have the time and labor involved. But I will say that I will be a subscriper and follow you. Thx for your info.
@hydrocrab74
@hydrocrab74 5 жыл бұрын
He has very Good info.
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 5 жыл бұрын
Thank you for watching!! CM
@johnkulpowich5260
@johnkulpowich5260 3 жыл бұрын
If you can't make up a bug find another profession
@TheHamadanners
@TheHamadanners 5 жыл бұрын
Awsome
@mnleber
@mnleber 4 жыл бұрын
If Im not mistaken the rubber (3M) high voltage tape calls for the sticky side out while wrapping and finishing up with the regular approved electrical tape
@eyeveedeath
@eyeveedeath 3 жыл бұрын
Thank you! Industrial mechanic here cringing with the thought of servicing this guys work in a peckerhead. Not a fan of his stripping practices either. I learned to score, break with 9s, and pull. Not whittling like it's a boy scout project.
@danielhoughtelling9721
@danielhoughtelling9721 2 жыл бұрын
@@eyeveedeath Its called pencil stripping. It's a common practice for aluminum. If you accidentally score some of the aluminum strands they can actually break off and cause a premature failure of the connection. Copper is much tougher. I use a tool that strips the jacket with out damaging the stranded wire.
@mnleber
@mnleber 4 жыл бұрын
Anti Oxidant? How do you keep moisture from leaking into joint between legs? Is your tape(s) UL or equivalent approved?
@KSMike1
@KSMike1 4 жыл бұрын
I need to splice 3 legs of #6-2/G NMB for a daisy chained, 2-outlet 50A welder circuit (so the first outlet box will have 1) a leg coming in from the panel, 2) a leg out to the second outlet, and 3) pigtails for the first receptacle). I assume there won’t be enough room in a 2-gang box for a 50A 6-50R receptacle AND the taped split bolts. What’s the proper way to arrange this - a separate box screwed to the side of the receptacle box, one for the receptacle and the other for all the splices? Or...?
@KSMike1
@KSMike1 4 жыл бұрын
Tom Garbo thanks for the reply. I actually just finished this up recently. For me the answer was to use Garvin masonry boxes with plaster ears welded on. This was the only solution I could find for a steel 2-gang box and still be 3-1/2” deep. Then I used Polaris Black IPL4-3A connectors instead of split bolts. Although tight, this made it possible to get everything into one box. Thanks again.
@Neil-ym8vy
@Neil-ym8vy 3 жыл бұрын
I have never used a split bolt bug or seen a JM Electrician use one in a panel or wireway. I usually see electricians use polaris taps which are not of the split bolt type usually in handholes and large junction boxes.
@TonyWadkins
@TonyWadkins 4 жыл бұрын
I wonder why the first bug's design uses a chunk of galvanized steel washer in between the two aluminum conductors. It seems natural that the two aluminum conductors should mash together for lower resistance? Just guessing that maybe the intermediate steel washer is somewhat concave so the strands of aluminum don't go haywire when compressed ? I have some of those and never really had much opportunity to use them. I'll have to dig em up and see what that washer looks like.
@Yielar1
@Yielar1 4 жыл бұрын
Because it's also rated for copper & aluminum connections and acts as a separation
@LibertyDIY
@LibertyDIY Жыл бұрын
I just found one that failed and it looks like it would not have failed so badly if they had not been separated.
@javiersalas7670
@javiersalas7670 2 жыл бұрын
Could you explain megging a motor or wire? 1k ohms to ground etc...thank you
@B5Blue1968
@B5Blue1968 5 жыл бұрын
Could you use the first split bolt that you used on the 2/0 wire for the inline splice with the 4/0 providing it would accept the 4/0?
@pepeman3099
@pepeman3099 4 жыл бұрын
Yes
@DJTrapillac
@DJTrapillac 2 жыл бұрын
Did u try it ?
@oscar27ization
@oscar27ization 5 жыл бұрын
U should demonstrate that live
@javiersalas7670
@javiersalas7670 2 жыл бұрын
Also all the components of a typical bucket. 480v, motor starter, OLs, control transformer etc...thank you
@christheother9088
@christheother9088 3 жыл бұрын
Years ago I was painting a house around the service wires and noticed splices that had electrical tape. Just electrical tape, none of that rubber tape. Half ass job, you could see many gaps in the wrap, obviously it was done just good enough so they looked taped from the ground. I verified the poor job when my forearm brushed against one of them ( yes, very bad judgment on my part). Thank god I was on an aluminum ladder so I could learn my lesson properly.
@billgalvin4297
@billgalvin4297 4 жыл бұрын
Don't split bolts need to be torqued to manufacturer specs? 2020 NEC seems to focus on this.
@johnkulpowich5260
@johnkulpowich5260 4 жыл бұрын
Every thing is tork. Switches meters breakers panels lugs. Bugs
@johnramirez5181
@johnramirez5181 Жыл бұрын
What's the brand for the second bug?
@nelsondog100
@nelsondog100 4 жыл бұрын
Doesn’t the galvanized connector corrode the aluminum wire over time?
@denniscurless904
@denniscurless904 4 жыл бұрын
No. In the high voltage industry the bronze connectors or aluminum connectors we use is coated with a non reactive covering. It is not zinc such as a galvanizing.
@benphartine
@benphartine 3 жыл бұрын
Your method works only when the wires are coming from different directions as in the second segment of this video. With your first example you didn’t make any attempt to waterproof between the two wires. Simply putting a small piece of that rubber tape on the wires where the insulation of each touches may have helped to make the connection water tight. You made an excellent video on how to wrap the nut and bare wires with those two types of tape but when water follows those wires in your first example and via capillary action, gets drawn up to the connection, under the tape, it will not dry out and only serve to cause trouble. 😳
@brysir
@brysir 4 жыл бұрын
Si can i use those bugs to extend my main electrical wire I need to move my breaker box some one can answer please
@benphartine
@benphartine 3 жыл бұрын
Check with your power company. They will be able to schedule the power being disconnected before the work is done and reconnected after it is finished. They also handle most of what is on their side of the meter and you are responsible for whatever is on your side of the meter.
@dahlia172
@dahlia172 3 жыл бұрын
Does this need to be done inside a junction box?
@glennreynolds962
@glennreynolds962 3 жыл бұрын
Normally a J box or trought unless it is at a service entrance head. Then it is in mid air.
@bh20jacob68
@bh20jacob68 Жыл бұрын
Can you barrier that 4/0 bug
@cobrakai2872
@cobrakai2872 5 жыл бұрын
Is grease required for Al wire? I did this (as a homeowner with permit) and greased all of the connections. I need to go back and rubberize the splices to thicken them as you showed. Thanks
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 5 жыл бұрын
No you just have to use the correct Bugs. CM
@benphartine
@benphartine 3 жыл бұрын
Check out this video on Noalox... kzbin.info/www/bejne/eGGYfahtnZqHn8k
@blockisle9
@blockisle9 3 жыл бұрын
I have always used Cambric tape first, then rubber then 33+
@JJMECC
@JJMECC 3 жыл бұрын
3m has a vid using the Resin tape💪
@blockisle9
@blockisle9 3 жыл бұрын
@@JJMECC found it. I’ve been doing it this way for 40 years. kzbin.info/www/bejne/b6XWqWmfopykpMk
@JJMECC
@JJMECC 3 жыл бұрын
@@blockisle9 Only 30+yrs for me LOL..
@blockisle9
@blockisle9 3 жыл бұрын
@@JJMECC LOL, The trade has changed a lot since then and Not necessarily for the better. The big box stores and device manufacturers have been doing a lot of lobbying and a lot of things required now are catered to the homeowners to make it easy for them.
@Iamorcy
@Iamorcy 4 жыл бұрын
Hodor??
@patrickbrumm4120
@patrickbrumm4120 8 ай бұрын
reminds me of wrapping my handlebars on my ten speed
@1trucxhondamov589
@1trucxhondamov589 4 жыл бұрын
Can I splice 3 service drop cables with that split-bolt bug? Get video by the way! 👍😃😷
@1hhenry
@1hhenry 4 жыл бұрын
If using Aluminum wire should I use an Aluminum bug or split-bolt and is it ok to a copper split bolt with Aluminum wire? Thanks!
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 4 жыл бұрын
As long as the bug is rated for copper. CM
@Redandranger
@Redandranger 3 жыл бұрын
Now let's do this with 6 #6 wires sticking out of a junction box.
@WiliamBennettwildarbennett
@WiliamBennettwildarbennett 3 жыл бұрын
Or 2- 350mcm
@javiersalas7670
@javiersalas7670 2 жыл бұрын
We know split bolts as kerneys
@davidwilke113
@davidwilke113 10 ай бұрын
Watching this made me want to go buy a crimp tool
@Sparky-it4gx
@Sparky-it4gx 4 жыл бұрын
To make it easier on the next guy that has to cut off the splice back wrap the connection with electrical tape before you put on the rubber tape. Makes it much easier to cut it off. Would have liked to see you cut the splice in half so people could see the thickness of the rubber tape, and that it was 2x the thickness of the cable insulation.
@mnleber
@mnleber 4 жыл бұрын
Doug Johansen I think that is one reason calls for tape to be wrapped on sticky side out.
@KayakMike
@KayakMike 2 жыл бұрын
I absolutely hate using butt connectors. Can this technique be used on 6awg wiring for a trolling motor? It would make life so much simpler. I don't see anyone in the boating world using this technique for their motors - but it just seems so much more simple than crimping butt connectors. If there's any reason you think this application wouldn't work for a trolling motor and 6awg please let me know. Other than aesthetics. I could care less how ugly it is and all my wiring is through the kayak, it would never get in the way.
@emil_llantigua1191
@emil_llantigua1191 4 жыл бұрын
whats the name of the second bolt?
@johnkulpowich5260
@johnkulpowich5260 4 жыл бұрын
Dead nuts
@michaeldove339
@michaeldove339 2 жыл бұрын
Parallel Groove Connector/ Gutter Taps/ In-Line Splice. Many names...depends on manufacturer
@emil_llantigua1191
@emil_llantigua1191 2 жыл бұрын
@@michaeldove339 thanks
@Order-in-Chaos
@Order-in-Chaos 4 жыл бұрын
... Or you can use a Polaris tap which is MUCH easier and safer but obviously more money.
@JH-ms3ny
@JH-ms3ny 4 жыл бұрын
Definitely the way to go, assuming the shop actually buys them for you.
@techmetal2292
@techmetal2292 3 жыл бұрын
And will way outlast this
@tcarable
@tcarable 2 жыл бұрын
Why no de ox
@crossmanbluev6049
@crossmanbluev6049 4 жыл бұрын
I didn’t lubricate the wire ,?
@aspensulphate
@aspensulphate Жыл бұрын
You didn't? Well, maybe you should.
@brandoncole6358
@brandoncole6358 4 жыл бұрын
This is wrong u use cambric tape wrapped backwards, the rubber tape, then supper 33 or another high grade vinyl tape
@techmetal2292
@techmetal2292 3 жыл бұрын
This doesn’t seem like it would hold up in a outdoor location. The temperatures alone would cause the adhesive on the tape to release and loosen up
@simplytrolling6869
@simplytrolling6869 2 жыл бұрын
Been working in the utility industry for a power company for 15 yrs and I must say that the tape as protection for anyone is complete nonsense.
Wire Nuts - Split Bolts - Splicing Wire
40:56
Right On With Jon Crane
Рет қаралды 38 М.
Split bolt connections, Electricians Need to Know, John Shook
7:04
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
Mama vs Son vs Daddy 😭🤣
00:13
DADDYSON SHOW
Рет қаралды 48 МЛН
НРАВИТСЯ ЭТОТ ФОРМАТ??
00:37
МЯТНАЯ ФАНТА
Рет қаралды 8 МЛН
Grounding and Bonding
8:01
schulerruler
Рет қаралды 666 М.
Wire Pulling Half Hitching Prep
6:07
Craig Michaud- Electrical Instructor
Рет қаралды 112 М.
How to make a 200 amp Weatherhead
16:29
Craig Michaud- Electrical Instructor
Рет қаралды 61 М.
Making a Leather 3 Legged Camp Stool
16:37
Odin's Wolf Survival
Рет қаралды 3,7 М.
Advice to a New Electrical Apprentice or thinking about a Trade!!
8:49
Craig Michaud- Electrical Instructor
Рет қаралды 6 М.
Why Neutrals & Grounds are Connected in a Main Panel
20:13
Benjamin Sahlstrom
Рет қаралды 1,5 МЛН
Что делать если забыл ОЧКИ??? #моястихия #swimming #юмор #fun
0:23
МОЯ СТИХИЯ | ПЛАВАНИЕ | МОСКВА
Рет қаралды 5 МЛН
BYD U8 танковый разворот
1:00
YOUR NEW AUTO
Рет қаралды 2,4 МЛН
How Can parents love their children equally? #shorts
0:38
mountainlion5
Рет қаралды 11 МЛН