I do most of my own repairs and I have fixed NG dryer valve. The electrical circuit that controls the burner valve is brilliant and involves a flame sensor, igniter, and three solenoid coils. The igniter is the key to the coils becoming energized. Before it becomes glowing hot, it acts as a resister. Once it is glowing, its resistance drops and allows the coils to receive the current they need to energize.
@theodoretepaske87555 жыл бұрын
Another symptom of a bad solenoid is the igniter will come on and go off without the gas coming on. It may take a while for that symptom to display itself. In my case it took three burner cycles for it to happen. At least they’re easy to replace.
@geeveeme4 жыл бұрын
that has to be the cleanest 7 year old dryer ever !
@vvince28552 жыл бұрын
What is the resistance for a good set of coils
@tcharles81726 жыл бұрын
How do you determine when it's time to change the Dryer Drum Support Roller?
@reciclagemcondutoresinfrat97416 жыл бұрын
Is normal yellow flame? I use LP. Thanks!
@AlmostReady5042 жыл бұрын
Doesn't the thermal fuse do a similar thing?
@vlberryg6 жыл бұрын
I change in mine the selenoids and the flame sensor, still have the same problem. any ideas?
@eekcoffeebeanz6 жыл бұрын
After replacing thermostats & thermistor etc I've concluded it's the cellenoids....I'm done taking mine apart to install new parts. I just cut a hole for access.ha!
@clintonjackson47976 жыл бұрын
If the flame comes on for 30 seconds and goes out and will not flame up again . The small coil on the gas valve is bad.
@luongsor17106 жыл бұрын
Thank you,it very helpful. Save me alot$$$$$. God bless you and you family
@bajapantis227 жыл бұрын
Will testing with wet clothes. Make it turn off faster?
@punker4Real7 жыл бұрын
It's call planed repairs or replacement HUGE SCAM! if you ask me