Measuring & Adjusting Furnace Gas Pressure X2

  Рет қаралды 73,608

HVAC School

HVAC School

Күн бұрын

Пікірлер: 39
@billj4859
@billj4859 6 жыл бұрын
Show this video to Testo so they make a version of the 510i where you can display both readings individually and the differential reading at the same time. Couldn't be that tough to have port 1, port 2, and differential displayed in the app.
@LuisRamirez-ge6xu
@LuisRamirez-ge6xu Ай бұрын
Thank You for your videos always showing good practices and information 👍
@1948Noam
@1948Noam 2 жыл бұрын
Thanks once again Bryan as your videos are worth their weight in gold especially for up and coming techs!
@michaelnerio1826
@michaelnerio1826 2 жыл бұрын
Good stuff... Thank you, Sir!
@staticpressurenerd5182
@staticpressurenerd5182 5 жыл бұрын
Great video! At some point Jim Bergmann might comment on this and discuss clocking the meter and setting your high fire manifold pressure anywhere from 3.2-3.8”wc depending on orifice size, elevation, and combustion analysis readings 🤓 I’m sure he has a video on this somewhere.
@YouTubeCommunists
@YouTubeCommunists 3 жыл бұрын
ORB @ 5:58 ,The spirits in the ether are concerned with these gas adjustments..lol
@rzh3443
@rzh3443 Жыл бұрын
I assume the input pressure is somewhat controlled by the utility and their pressure diaphragm at the meter so you would only want to reduce the input at valve if too high? My Rheem two stage furnace has a White Rogers valve which requires a 5/16 sleeve to cover the adjustment tube on the valve and which then connects to an adapter and hose to the manometer. It has a similar port for input measurement , but no means to adjust it ; further it’s not called for adjustment in the Furnace Manual. Thanks for the video!
@munawarsoomro8958
@munawarsoomro8958 5 жыл бұрын
Hi, awesome videos. For split system, where did 1.9 on first stage come from?
@Boojyman
@Boojyman 2 жыл бұрын
Thanks
@JoseGuerrero-sj5ie
@JoseGuerrero-sj5ie 5 жыл бұрын
Sr another great video thank for the tips
@dilboteabaggins
@dilboteabaggins 6 жыл бұрын
Screw In to INcrease. Works with most valves with a diaphragm and spring
@timmyshrall9456
@timmyshrall9456 3 жыл бұрын
Who was the pipe dope master
@petesingh292
@petesingh292 5 жыл бұрын
I enjoyed your video but what's the pressure for low Fire ? Plz reply
@superiorcomfortheatingairl3373
@superiorcomfortheatingairl3373 6 жыл бұрын
You should of demonstrated the Carrier 3 stage furnace with throttle gas valve. I had to replace the valve and adjust the pressure for propane, that wasn’t enjoyable.
@mychoclabwinston
@mychoclabwinston 5 жыл бұрын
Never buy a carrier, are you not talking about a modulating furnace? Not 3 stages, modulating are garbage, all manufactures have had issues
@dtdarby
@dtdarby 6 жыл бұрын
Good vid.
@TheLeahmsmith
@TheLeahmsmith 2 жыл бұрын
What about the other type of gas valve that doesn't use the 3/8, it takes a much smaller hex which I think is 3/32 and you use a tube that goes over the manifold test port? I lost my hex bit and clicked on this video to see what exact size cuz I need to order another one
@bobrub
@bobrub 6 жыл бұрын
Good video but ........ in Matt's example he switched the 2 locations of the High/Low adjustment ports. At 5:30 he adjusts high pressure at the left port and at 6:19 he says the same left port is the low pressure adjustment port. 2ndly, the incoming gas pressure port is checked (label spec. calls for 7 iwc max - 5 iwc min) , yet no mention at all about high/low SUPPLY pressure after that. Not sure, but I think MQ app was showing supply pressure around 7.9 - 8.1 iwc if that's what line 810 is in the app. That is 1 iwc more than max spec of 7. Is that a problem. What is the solution? 3rdly, isn't the incoming supply pressure check dependent on all the other gas appliances usage. Like if a gas dryer, a instantaneous gas water heater, gas oven and a gas fireplace all were firing simultaneously, doesn't that pull down the supply pressure at the furnace inlet?
@jeffb8437
@jeffb8437 6 жыл бұрын
If supply is to high you turn down at the meters regulator. It is a good idea to check supply with other appliances running to make sure your gas line is sized right and doesn’t fall below minimum input. If supply is to high it can ruin your valve. The gas valves max and the furnace rating may not be the same but always go with what’s on the furnace tag
@saghirahmad9634
@saghirahmad9634 5 жыл бұрын
thanks sir
@kidalwys
@kidalwys 6 жыл бұрын
I always put the cap back on and see what the pressure is. I’ve noticed gas pressure goes up a little bit when you put it on.
@FB-gm6el
@FB-gm6el 3 жыл бұрын
beginner question, but: what are the long term results if pressures are allowed to run too high? general overheating of the furnace/exhaust? and how about if the pressures run too low?
@Jon-hx7pe
@Jon-hx7pe 3 жыл бұрын
if it's over-fired you can get bad combustion (high co), premature hxt failure and overheating.
@MindKontrolleProject
@MindKontrolleProject 3 жыл бұрын
What would cause the outlet/manifold gas pressure change over time?
@charlesmalinoski6325
@charlesmalinoski6325 6 жыл бұрын
Question What size torx driver was he using on the Goodman, with the Honeywell Gas Valve ? Thanks !!
@hangngoaigiare
@hangngoaigiare 4 жыл бұрын
So you don’t perform combustion in conjunction with adjust gas pressure?
@5822huron
@5822huron 4 жыл бұрын
No.. combustion is for C02 output. All you need to measure is Temp Rise. W.C in each stage and observe the flame 🔥
@joeshearer1247
@joeshearer1247 6 жыл бұрын
Service valve tool works perfect too
@joeshearer1247
@joeshearer1247 6 жыл бұрын
Edit that's what he was using too
@realgagne2956
@realgagne2956 4 жыл бұрын
1st. video doesn't show how to adjust INLET pressure to make sure it's right. How would you do that?
@efco24
@efco24 4 жыл бұрын
That depends. If it's a few inches high or low, call your gas company and have them adjust it at the meter. If it's 0 inches, pay your bill! Other than making sure your piping is skookum, there's nothing you should be doing to adjust input pressure.
@whit6282
@whit6282 4 жыл бұрын
Can’t you just install a regulator from the line coming in
@unabridgeddick6645
@unabridgeddick6645 4 ай бұрын
It's a 0.125 thread, in case you'd rather spend $7 rather than a lot more because Yellow Jacket or Fieldpiece resells it to you.
@SuperKingcobra33
@SuperKingcobra33 6 жыл бұрын
The nameplate shows 10" WC for LP, that seems pretty high, I wonder what the flame color and CO is with that setting?
@hangngoaigiare
@hangngoaigiare 4 жыл бұрын
Sure need a conjunction combustion analysis
@djsarro1940
@djsarro1940 2 жыл бұрын
what about lp
@bshx01
@bshx01 3 жыл бұрын
How long did you wait before making adjustments.(I was told 15min) Ex if it’s 3.8 and I’m at 1.7 how long should I wait before adjusting? Cause sometimes I adjust it and it barely goes up. I honestly be too scared to raise the pressure, scares it blow up on me 😅
@ilovenythismuchilovenewyor5801
@ilovenythismuchilovenewyor5801 2 жыл бұрын
Ira alot easier than we think ... just have to not over think. study up and be confident w knowledge of what to do.
@Oscarbm1234
@Oscarbm1234 6 жыл бұрын
I’ve never worked on a furnace. Smh
Service Call | How To Diagnose A Bad Gas Valve
10:41
HVAC Tech Tips
Рет қаралды 148 М.
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
Manifold Gas Pressure
10:59
Monroe Community College Digital Production
Рет қаралды 113 М.
Measuring & setting Gas Pressure using a manometer
11:01
Mechanical Hub
Рет қаралды 93 М.
Using a Digital Manometer to Set Furnace Natural Gas Pressure
15:11
Furnace Gas Valve Operation and Testing! 2 Stage and 3 Stage!
9:48
AC Service Tech LLC
Рет қаралды 46 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 254 М.
Prevent this Common Manometer Mistake
3:57
HVAC School
Рет қаралды 57 М.
Gas Furnace Not Heating Typical Lennox Problems
18:54
HVACR Survival
Рет қаралды 45 М.
The Real Operation of a PRESSURE SWITCH in a GAS FURNACE Heater! Also Testing!
13:37
Adjusting Gas Pressure on a Standard and Gemini Furnace Valve
6:51