How to Check Manifold and Inlet Pressure on a Gas Furnace - Tips on How to Maintenance a Gas Furnace

  Рет қаралды 13,423

HVAC Tech Knowledgy

HVAC Tech Knowledgy

Күн бұрын

Пікірлер: 33
@jasonbrand9812
@jasonbrand9812 Ай бұрын
Thanks bro, just bought the same fieldpiece manometer
@MegaLuisvelasco
@MegaLuisvelasco 7 ай бұрын
Excelent video and right to the point, thank you
@sarahchanel7820
@sarahchanel7820 3 жыл бұрын
Good work brother
@HVACTechKnowledgy
@HVACTechKnowledgy 3 жыл бұрын
Thanks alot!
@qzorn4440
@qzorn4440 Жыл бұрын
A most excellent video. Thanks.
@HVACTechKnowledgy
@HVACTechKnowledgy Жыл бұрын
No prob! Thanks for watching
@l.a.m7645
@l.a.m7645 6 ай бұрын
What size brass barb fittings did you use?
@roberts1159
@roberts1159 3 жыл бұрын
Do you always do a inlet and outlet pressure test during a maintenance or just if the flame pattern does not look right ? What if you don’t have a pressure regulator on the inlet side of the gas valve ? Thanks for sharing.
@HVACTechKnowledgy
@HVACTechKnowledgy 3 жыл бұрын
No I don't always check gas pressures. I'll usually check if the flame sounds weak or aggressive or if my temp rise is off. Also you still want to check the inlet pressure whether there's are regulator or not.
@Talentman18
@Talentman18 2 ай бұрын
Should I get the wireless monometer? Or the SDMN6?
@HVACTechKnowledgy
@HVACTechKnowledgy 2 ай бұрын
Wireless all day for me! Although I'm beginning to see the benefits of not having to sync to Bluetooth every time I want to use an instrument
@Talentman18
@Talentman18 2 ай бұрын
@@HVACTechKnowledgy for aA/C season I will stick with the wireless. And for heating season I will stick with the instruments.
@iReP809
@iReP809 10 ай бұрын
Where can I get a manifold just like that one ? The 3rd burner and the end of the manifold is letting out too much of a flame and it’s burning the inside of my furnace. Any suggestions !?
@HVACTechKnowledgy
@HVACTechKnowledgy 10 ай бұрын
Hey usually I'm all for DIY repairs its one of the reasons I started this channel but Honestly if you don't have the proper equipment to test a combustion Appliance IE combustion analyzer menometers temp probes Id probably just try to call out someone who does as you don't want to be doing experimental repairs on something that literally contains a active fire inside of your house.
@amplifiedrecoil9639
@amplifiedrecoil9639 Ай бұрын
How do you change the pressure though if it wasn't reading perfect?
@butlerstouchHVAC
@butlerstouchHVAC Жыл бұрын
when do you usually check the gas pressure? what would make you use these tools to adjust the pressure
@bernardocisneros4402
@bernardocisneros4402 Ай бұрын
You definitely want to check it when replacing the valve, and when having problems and you think it's related to gas pressure.
@danielantoniodiaz3564
@danielantoniodiaz3564 11 ай бұрын
If you have a high inlet gas pressure and the out is at the rated 3.5" w.c., can this cause incomplete combustion?
@HVACTechKnowledgy
@HVACTechKnowledgy 11 ай бұрын
If the inlet pressure is high enough to defeat the gas valve regulator and affect the manifold pressure then yes
@threestans9096
@threestans9096 14 күн бұрын
@@HVACTechKnowledgybut he says it is AT that… failed regulator, leaking more that can’t be measured?
@mark.r8900
@mark.r8900 2 жыл бұрын
Hi, I have a lennox mid efficiency single stage gas furnace. The manifold on rating plate is 3.5"wc. But I am only getting 1.7"wc. I adjusted to 3.5"wc according to the rating plate. But the furnace overheats and my temperature rise is out of specification. The furnace also intermittently short cycles. Can this be a bad gas valve? Thank you.
@HVACTechKnowledgy
@HVACTechKnowledgy 2 жыл бұрын
What type of manometer are you using? If it's digital did you zero it out before checking? Did you check with another instrument? Also what caused you to check the gas pressure in the first place?
@bernardocisneros4402
@bernardocisneros4402 Ай бұрын
No, it's NOT a bad gas valve. I think the last person to adjust it, addressed the sympton and not the cause. That valve should be set to 3.5 not 1.7 WC. You're underfiring at 1.7. The cause is going to be airflow, so you want to look in ducting for any obstructions and take out blower fan to clean it. When they get dirty, their airflow decreases exponentially. First clean the blower fan, and if that doesn't fix it, check all ductwork for obstructions. Especially the flue. If you already fixed it, please let us know what fixed it. I'm sure it will help someone in the future.
@beefing313
@beefing313 8 ай бұрын
👍🏾👍🏾👍🏾
@JULZ_RULZ
@JULZ_RULZ Ай бұрын
My husband is an HVAC installer and he noticed in our brand new HEIL 4 ton a faint smell of gas near the manifold on shut down. It dissipates as soon as he opens the front panel. Majority of stuff I read say it's normal for a faint smell until gas completely dissipates but I thought I would ask anyway. Our last unit died after 22 yrs...it was a Carrier. Is this a new "green/high efficiency" issue?🫤 Thanks😊
@BrianSpell-k6c
@BrianSpell-k6c 10 ай бұрын
Do you need to use a manometer?
@cilopez155
@cilopez155 10 ай бұрын
Yes
@thomasbutler-k6c
@thomasbutler-k6c Жыл бұрын
Why does this system have a preliminary external regulator? Thanks!
@HVACTechKnowledgy
@HVACTechKnowledgy Жыл бұрын
Because the inlet gas pressure is too high of a pressure for the gas valve to meter properly so it needs to be stepped down around 7 to 10 in of water column before the gas valve steps it down to 3.5 in.
@richbredsten349
@richbredsten349 5 ай бұрын
@@HVACTechKnowledgy is it 2 pounds of pressure on the inlet side of regulator?
@bernardocisneros4402
@bernardocisneros4402 Ай бұрын
@@richbredsten349 I don't know what the pressure is before the stand-alone regulator but the pressure before the regulator in the valve is about 8 inches of Water Column which equals about one-third of a PSI
@frankkoppen7281
@frankkoppen7281 11 ай бұрын
2 years ago , but is this lp -or- ng
@HVACTechKnowledgy
@HVACTechKnowledgy 11 ай бұрын
Natural Gas
Measuring & Adjusting Furnace Gas Pressure X2
12:28
HVAC School
Рет қаралды 71 М.
Manifold Gas Pressure
10:59
Monroe Community College Digital Production
Рет қаралды 112 М.
I thought one thing and the truth is something else 😂
00:34
عائلة ابو رعد Abo Raad family
Рет қаралды 7 МЛН
Players push long pins through a cardboard box attempting to pop the balloon!
00:31
БУ, ИСПУГАЛСЯ?? #shorts
00:22
Паша Осадчий
Рет қаралды 2,9 МЛН
How To Clean Furnace Burners
15:20
Word of Advice TV
Рет қаралды 402 М.
Yearly Maintenance And Service On A Gas Furnace For Beginners!
20:41
Jeff’s HVAC Adventures
Рет қаралды 4,6 М.
Natural Gas to Propane Conversion on a Furnace from Start to Finish!
26:12
AC Service Tech LLC
Рет қаралды 283 М.
Service Call | How To Diagnose A Bad Gas Valve
10:41
HVAC Tech Tips
Рет қаралды 131 М.
If You're Not TESTING, How Do You KNOW?!?!
13:00
Quality HVACR
Рет қаралды 26 М.
Locating Natural Gas Leaks Using High And Low Pressure Tests!
16:30
Jeff’s HVAC Adventures
Рет қаралды 2 М.
I thought one thing and the truth is something else 😂
00:34
عائلة ابو رعد Abo Raad family
Рет қаралды 7 МЛН