This morning, this is the best explanation available on KZbin in my humble opinion. Thank you
@SiteReader Жыл бұрын
He gets right to the point and gives you all the information you need, straight up with no BS. I wasted an hour watching two other ones that didn't show half what he shows.
@petergilbert1445 жыл бұрын
As always great job Bill. I am in my 4th class with him and he not only can teach and lay a ton of information on you, but make a long class fun, exciting, and a place you look forward to being in. This is the kind of guy you want as your technician that has more brains than a much senior tech. Edit: today I become an alumni of the program.
@KavinSBS3 жыл бұрын
the best video I have ever seen about explaining the gas valve and how to adjust it,
@freddesjardins7399 Жыл бұрын
Excellent instructions complete and very concise from a to z 👍
@aundraydavid48213 жыл бұрын
Almost 4 years I've been outta school bill, still helping me out! Miss being in the Roc
@henripedro47605 жыл бұрын
Excellent informative video. The man really presented the information in a very professional way. Thank you.
@DONALD19515 жыл бұрын
Gas companies are also responsible for the meter. Homeowner is responsible for everything after the meter outlet. Some services don’t have a regulator. If it is a low pressure service. Very good video.
@Feather-Frame5 жыл бұрын
Very informative video. I learned a lot. Surprised this video is this old with only a couple comments!
@kevincopley7783 Жыл бұрын
Thank you so much for this video. You’ve saved me a ton of headaches!
@sirvayr4 жыл бұрын
I was wondering about this. Saved me money on buying a digital fofr something I will never use again.
@bigd8354 жыл бұрын
Fantastic video. Took all the voodoo out of the furnace set up. Thank you !!
@chrismaddox154 жыл бұрын
Great info..... thanks for such a great video!
@jefferydickinson31293 жыл бұрын
Very good video great presentation
@rasheed45854 жыл бұрын
Explained professionally
@tbi11612 жыл бұрын
Well done teaching, thank you
@miguelmorales61483 жыл бұрын
Very good video, so professional good explanations
@CVDUSA Жыл бұрын
very good
@justincomer73024 жыл бұрын
That’s a very basic way to set gas pressure. That 3.5 rating on the furnace is in perfect conditions at an exact altitude with the exact size orfice.. Just because you set a furnace at 3.5” WC does not mean you getting a safe combustion or complete combustion. A combustion analyzer is the only proper way to determine your getting the correct fuel to air ratio. Adjusting the gas pressure up or down while watching the combustion readings to make sure your at the right oxygen and CO content within the furnace. So you may end up with 3.2” or 3.8” and orfices may need to be replaced to achieve this. So if your adjusting gas pressure with out doing a combustion analysis then your just guessing and could be leaving an unsafe condition.
@brianmutascio83254 жыл бұрын
Why is it, that equipment mfg don't supply the O2 & CO content on the furnace spec data plate, along with the "W.C data....
@boby1153 жыл бұрын
@@brianmutascio8325 , you are correct. The manufacturer's info plate will supply you with minimum and maximum Inlet pressures, specific manifold pressure & temperature rise ranges. Oxygen, CO2, CO and moisture content can be analyzed. Analyzing the products of combustion is a good practice, so we can verify the unit is in range but using it to adjust gas pressure and determining the fixed orifice sizes should be left to the OEM not the installer. Just an FYI, a lot of things can affect combustion analyzation ( quality of gas, combustion air quality, humidity , Venturi adjustment, gas pressure and yes improper orifice sizing, but someone would have to make a mistake for that to happen). Anytime a gas Appliance is put into service, always follow manufacturers instructions,GAMA ( Gas Appliance Manufacturers Association) requirements & the National Gas Fuel Codes. Hope some of this helps and you all please stay safe out there.
@tgamirov3 жыл бұрын
Excellent video, thanks
@KavinSBS3 жыл бұрын
The best way to explain
@mikefox23793 жыл бұрын
I checked pressures on a the newer valve with the small allen key screws. I actually removed the screw and put it back as tight as it was (to the best of my knowledge) Is this going to cause an issue? I just heard you say to NOT remove the screw and just turn it a full turn.
@billrimmer55964 жыл бұрын
Excellent job!!
@bobbyz77363 жыл бұрын
The furnace shown in the example shows a union before the gas valve. Shouldn't the union be placed after the gas valve?
@stevebockiaro38322 жыл бұрын
How do you adjust the inlet gas to the valve if it’s to low or high?
@eegg69542 жыл бұрын
On a high pressure service, the outside pressure regulator can be adjusted, but this is the job of the utility. On a low pressure service, the utility should be contacted after you have checked the sizing and loss of your supply piping run for your connected load.
@donnierobertson30884 жыл бұрын
Great job and video like always
@enzoamore91734 жыл бұрын
What causes condensation in flue pipe on natural gas boiler?
@hkhalil7183 жыл бұрын
what size of the fitting ? you said 1/4 in, right?
@daveo.54793 жыл бұрын
great video!
@c_farther52085 жыл бұрын
I used to go to that college, smart people there. Anyway, is there a reason I get a high pitched squeal when it is running? Seems like it only does that when it is super cold outside.
@christopherpaul29385 жыл бұрын
great video
@luisvillegas44123 жыл бұрын
Very good vidio 👋
@williambuck56527 жыл бұрын
YOUR VIDEO IS VERY GOOD!!!
@enzoamore91734 жыл бұрын
The barb fitting only goes on hand tight when taking manifold gas pressure?
@Pauladigms4 жыл бұрын
correct
@lancerudy99344 жыл бұрын
What would happen if you lowered the gas pressure to the out put side of regulator.?
@eegg69542 жыл бұрын
The flame lowers and the boiler is down fired, putting out less heating BTU... The mixture air/fuel ratio may also be affected and should be adjusted using the proper analyzer if desired. The firing rate should not be modified unless approved by the burner manufacturer.
@vicmazza17562 жыл бұрын
No look at actual meter ... Plus and minus ports on meter ...using the meter??????