Medium Off Grid system part way through installation.

  Рет қаралды 7,234

Ben Stanton

Ben Stanton

Күн бұрын

Пікірлер: 25
@offroadtracks7682
@offroadtracks7682 4 ай бұрын
The cable loops are a great idea, wish that was more of a thing 👍🏻
@benstanton
@benstanton 4 ай бұрын
Thanks - my little secret is that loops are easier to manage during install than straight cables 😁
@ben99873
@ben99873 2 ай бұрын
Appreciate the clean install. Nice
@mwhelan53
@mwhelan53 26 күн бұрын
Nice wee system Ben.
@davidpatrick1813
@davidpatrick1813 4 ай бұрын
Nice clean install. Make solar conduit so wires can be easily replaced.
@benstanton
@benstanton 4 ай бұрын
Yes, that's the plan
@paulgreenhalgh4790
@paulgreenhalgh4790 25 күн бұрын
Combination remote off is a good idea but I'm not wild about the emergency switch location! I would have put it well away and maybe just inside the door.
@benstanton
@benstanton 25 күн бұрын
@@paulgreenhalgh4790 yes fair enough. It was more of an easy “off” button for an aging customer rather than an emergency kill switch.. 😂 “in case of fire stretch your hand through the burning inferno and press this little red melted button..!” 😂 You point is duly noted! 👍
@petersamios5409
@petersamios5409 4 ай бұрын
Very good explanation. A couple of comments - you may add some ventilation to Cerbo Gx box - at least some pass through as electronics can get hot. 2nd, I'd keep the data cables in their own pipes and not co-mingle them with power. I know can bus is quite resilient, but emf can still cause issues.
@benstanton
@benstanton 4 ай бұрын
Yeah - I agree … BUT… there are pros and cons to your first point. . . Pros (as you stated: cooling) - but this is a small system so not a lot of work being done by the GX. Cons of ventilation… rodents and insects. Your second point is valid. It seems like UTP handles most of the data losses and the victron comms appears to handle the occasional dropout of data… appreciate the comment ! You are obviously aware of these issues. For larger systems these things would become more important!
@petersamios5409
@petersamios5409 4 ай бұрын
@@benstanton thanks for your reply. To add to my first point - maybe a screen of some sort on either side - this should block out the insect/rodent problem.
@martijnheeroma5492
@martijnheeroma5492 4 ай бұрын
nice cable management
@benstanton
@benstanton 4 ай бұрын
Thanks - I try but don't always succeed... Each time I do another install I try to make it t tiny bit better than the last one.
@Electronzap
@Electronzap 3 ай бұрын
Very nice setup.
@benstanton
@benstanton 2 ай бұрын
Thanks! I try to do a little better each time - but sometimes time, tools and gear hinder me!
@lsd885
@lsd885 2 ай бұрын
I do not see any fuses on the out of the Solar control or anywhere
@shankabriawan5308
@shankabriawan5308 2 ай бұрын
Hey ben iv got two lite5/4 in parrele in the battery details on my victron system it shows total ah capacity it jumps from 194 to 100 then staying on 100 is this normal? Or what would cause this thanks.
@Joelwilly57
@Joelwilly57 2 ай бұрын
Does the muiltiplus do power limiting?
@benstanton
@benstanton 2 ай бұрын
Short answer, yes… but only when AC in is connected.
@curmudgeinnak
@curmudgeinnak 4 ай бұрын
What is the standby consumption of that unit? I never find ones that are what they claim.
@martijnheeroma5492
@martijnheeroma5492 4 ай бұрын
11w idle
@curmudgeinnak
@curmudgeinnak 4 ай бұрын
@@martijnheeroma5492 well if that is true that is a heck of a lot better than my system which i know is Meh.
@benstanton
@benstanton 4 ай бұрын
Yes, as martijn says the manual says 11 watts but in reality they can fluctuate between that and 20 watts for this unit.. Bear in mind that the standby current is VERY difficult to measure: a clamp meter is constantly trying to calculate the RMS amongst the sinewave mess, a hall effect sensor and even shunts (used by BMS units) are notorious for measuring harmonics and so all you are really left with is the testing done by a manufacturer OR test it yourself on a small Lithium battery by leaving it on for a few days on standby and measure the voltage change as the cells go from completely charged to around 2% SOC where the voltages "drops off the cliff"... Then divide the known w/h of the battery by time and you have "actual" standby current... but no-one is seriously going to do this for a normal install, if your design is that close to the wire you've spent too much time on design where that cost could be better spent on a slightly larger battery... 🧐
@martijnheeroma5492
@martijnheeroma5492 4 ай бұрын
@@benstanton I measure my AC and DC loads with shunts/BMV712 in the DC line, VenusOS running on a Raspberry, reading into HomeAssistant on a Odroid N2+ with mqtt
@benstanton
@benstanton 2 ай бұрын
@@martijnheeroma5492 sweet! sounds like you've got some cool stuff going on!
UNO!
00:18
БРУНО
Рет қаралды 4,5 МЛН
Amazing 48V Van life electrical system!
24:03
the JaYoe Nation
Рет қаралды 33 М.
Victron + LiTime 48v off-grid
14:50
Brad Cagle
Рет қаралды 17 М.
EASY CHEAP STRONG DIY 3KW Solar Ground Mount
23:41
DIY Volts
Рет қаралды 33 М.
How Does Off Grid Solar Work - Explained with Diagrams
8:06
Cleversolarpower by Nick
Рет қаралды 46 М.
EG4 3,000W All-In-One Inverter - Beginner Friendly Solar Setup!
12:35
SolarEdge PV home system setup!
15:44
Oval Renewables
Рет қаралды 15 М.
5600 watt grid tied solar system with limiting inverters
14:48
BertsFordFactory
Рет қаралды 100 М.
Solar String Voltage Made Easy! How many solar panels can you safely connect?
14:11
DIY Solar Power with Will Prowse
Рет қаралды 146 М.
Understanding the Victron Products
20:41
The Off-Grid Shop
Рет қаралды 55 М.