I have an audit coming in a few weeks and this is soooo useful compared to other heat pumps videos. You're a life save. Thanks!
@MEPAcademy2 жыл бұрын
You're Welcome. Good luck on your audit.
@YT-BARBARIAN5 ай бұрын
@@MEPAcademyyou've got sub just because what you're doing you're doing it good
@wiynwiyn Жыл бұрын
So educational. Thank you very much. Excellent resources toward my architectural licensure. Subscribed.
@MEPAcademy Жыл бұрын
Glad it was helpful! Thanks for watching. Good luck on your Test.
@JustinWeiss-c5g2 ай бұрын
very well illustrated and great walk-through. thanks!
@MEPAcademy2 ай бұрын
Thanks for watching.
@marcus6216 Жыл бұрын
Thank you for your video! However, I would like to ask why both inlet and outlet of the boiler are connected to the same pipe? I guess it is the chilled water return pipe, right? I feel confused for the connection...
@MEPAcademy Жыл бұрын
The boiler is used for the tempering of the water, and this is the standard method of connecting to the condenser water piping. There is no chilled water, this is the condenser water piping that is kept within a certain temperature range and the boiler only adds heat if the loop temperature drops below the set point.
@worldofInsightfulthings Жыл бұрын
Very well done!
@MEPAcademy Жыл бұрын
Thank you very much!
@LHMOM.8610 Жыл бұрын
Thanks so much! Best explanation of this system on the internet.
@MEPAcademy Жыл бұрын
Glad it was helpful! Thanks for watching.
@mukulmustikar2920 Жыл бұрын
can we not use both AC and water heater together?
@MEPAcademy Жыл бұрын
Yes, they make heat recovery heat pumps that can be used to heat domestic water.
@mimoubougou776210 ай бұрын
The coil is the same?
@MEPAcademy10 ай бұрын
The inside coils are similar, while the outdoor coil is different on a water-cooled unit because of the need to exchange heat between two fluids, instead of a fluid and air.
@mohamedmaroof72102 жыл бұрын
very useful
@MEPAcademy2 жыл бұрын
Glad you think so!
@bruceboucher21342 жыл бұрын
Brilliant just have to adjust for Imperial and Metric operation😂
@MEPAcademy2 жыл бұрын
We plan to include more metric values in future videos. it only makes sense since most of the world is already using metric values.Thanks
@hussainDilawer-zz9sd16 күн бұрын
YOU MISSED A WHOLE POINT , IF THE PIPE LOOP SHOULD BE OPEN OR CLOSED ? AS PER YOUR PRESENTATION ITS SHOWS OPEN
@MEPAcademy15 күн бұрын
Both system types are shown. There is a closed loop used in a Water Source Heat Pump system using a Fluid Cooler, and an open loop in a Ground Source Heat Pump application using ground water. Using a closed loop with a fluid Cooler protects the heat exchanger.