RC Slab Design EC2 - Worked example - Shear and deflection checks

  Рет қаралды 87,560

Mike Bather

Mike Bather

Күн бұрын

Пікірлер: 46
@mikebather
@mikebather 7 жыл бұрын
Hi Hon Tin Chin, Vrdc1 & Vrdc2 are two different methods of finding the resistance of the RC slab and they can be used at any position along the length of the slab. In this example, I have used the formulae to find the resistance of the slab adjacent to the support. I hope that this helps, Mike
@ahmedhossam5604
@ahmedhossam5604 4 жыл бұрын
If we were doing the shear check for a flat slab, do we just use the reaction in the columns like you did here or it depends on whether it’s an edge, internal or corner column. I have been looking for an example all over the internet but couldn’t find anything tackling this point in particular.
@pacorandom1584
@pacorandom1584 9 жыл бұрын
Great video, really good explanation could you do a two-way slab or flat slab video?
@abduadam3404
@abduadam3404 4 жыл бұрын
Very helpful ,could you do detailing drawing!Thanks Mike.
@rbt123246
@rbt123246 8 жыл бұрын
Is there a mistake in the Vrdc2 calculation?
@mikebather
@mikebather 8 жыл бұрын
Hi Robert, Thanks for the comment. Unfortunately there is a mistake in the arithmetic and the answer is actually 124.9kN. Please see the ERRATUM above. Mike
@rbt123246
@rbt123246 8 жыл бұрын
+Mike Bather Thanks for that Mike. I was using your very helpful videos to design a similar slab so that clarifies that discrepancy.
@py_tok5589
@py_tok5589 2 жыл бұрын
@@mikebather yes, 124.9 kN right answer
@shazrinyusof7454
@shazrinyusof7454 10 жыл бұрын
very well explained, Sir. and very helpful. i really hope that you will upload a video on t-beams, Sir. Your explanations are crystal clear :)
@王黎-z1d
@王黎-z1d 5 жыл бұрын
why the Vradc2 is 69.4kN?I got different results
@mikebather
@mikebather 5 жыл бұрын
Hi, Thanks for the comment. Unfortunately there is a mistake in the arithmetic and the answer is actually 124.9kN. Please see the ERRATUM above. Mike
@anjikuiyalams6417
@anjikuiyalams6417 4 жыл бұрын
Hi Mike, lovely video....clear and concise.......is the reaction/shear force value suppose to be 18.125kn?? And not 17.3kn?
@andrewmorley1225
@andrewmorley1225 10 жыл бұрын
Brilliant video, you teach it so much better than what I was taught.
@qasimmuhammad6986
@qasimmuhammad6986 9 жыл бұрын
Hi Mike, its very noble of you to deliver these short lectures on youtube. In a skew deck slab usually one gets bigger shear values in obtuse corners. Is this ok if we increase the the size of the main reinforcement locally or add some vertical bars locally (links or bent up bars ) ? We have minimum shear reinforcement for the beams in EC2. Is there a concept of minimum shear reinforcement for slab with reference to high shear in skew slabs. Thanks
@mousa11b2
@mousa11b2 7 жыл бұрын
from where did you get this table? is it from the ACI CODE?
@engineermistructe3768
@engineermistructe3768 10 жыл бұрын
very clear - well explained- excellent
@mikebather
@mikebather 10 жыл бұрын
Hi S Fara, thanks for taking the time to let me know.
@alaninkarachi
@alaninkarachi 9 жыл бұрын
Excellent. Could have done with KZbin back when I went to Uni....:)
@hontinchin5229
@hontinchin5229 7 жыл бұрын
Hi sir, may I know where is Vrdc1 & Vrdc2 located?
@wdalrawi88
@wdalrawi88 10 жыл бұрын
Very clear and helpfull, what if the designed shear is greater than the resistant oncrete capacity how the procedures will be and also for the span/effective depth ratio >30
@mikebather
@mikebather 10 жыл бұрын
Almost all slabs are designed so that their shear resistance is greater than the design shear forces applied to them. When the design shear forces exceed the resistance, most engineers redesign the slab as it is a relatively unusual and expensive business increasing the shear resistance of a simply supported slab. Using large span to effective depth ratios is really outside the focus of this little video. You would need to check out the actual stresses in the reinforcement and then in some circumstances, EC2 permits larger span to depth ratios.
@venodjamo
@venodjamo 8 жыл бұрын
hi Mike. Thank you for your videos, very useful. But what is the next step if my deflection is not ok, as in my actual span/depth ratio is greater then my allowable span/depth ratio?
@mikebather
@mikebather 8 жыл бұрын
Hi Kapalesa Katjomuise, unfortunately there is not much you can do. Increase the depth or decrease the span are the simplest things to do. If these are not possible then you could consider increasing the steel reinforcement. Many engineers begin their calcs with the span/depth check to prevent this. I hope this helps.
@venodjamo
@venodjamo 8 жыл бұрын
it does help, thank you very much Mike.
@jamesbeckson8817
@jamesbeckson8817 6 жыл бұрын
Hi @Mike can you do one similar worked example for two way slab? Or is there already in your channel? I did not find it. Hope to see it soon. Thanks
@mikebather
@mikebather 6 жыл бұрын
Hi James Beckson, thanks for the suggestion. I have not done a video (for 2 way spanning slabs) yet, but hope to do so one day, Mike
@jamesbeckson8817
@jamesbeckson8817 6 жыл бұрын
Thanks for the response Mike.. Hope to see more videos in future. They are really helpful.
@MrPabodha
@MrPabodha 7 жыл бұрын
Hi Mike, Thanks for the great video. Btw, is there any thumb rule for determining the lap length for main and curtailment r/f? Thank you
@mikebather
@mikebather 7 жыл бұрын
Hi Pabodha Kannangara, thanks for the comments. For small scale work, laps of 40 d (d is bar diameter) were commonly used with the old British Standards. This figure could still be used with the Eurocodes but for larger jobs really an RC detailer would be able to calculate lap lengths more accurately using EC2 and this could lead to a more sustainable design (i.e. less material used). I hope that this helps, Mike
@MrPabodha
@MrPabodha 7 жыл бұрын
Tks Mike. I got it.
@GriffithGrey
@GriffithGrey 10 жыл бұрын
Hi, how would you design a T-beam for short-term and long-term deflection?
@mikebather
@mikebather 10 жыл бұрын
Hi GriffithGrey, Sorry but I have no plans for dealing with T beams in the very near future. These videos are just a little bit of support for our first year students, Mike
@ronow7682
@ronow7682 10 жыл бұрын
very good explanation. Do you have any video about precast concrete design?
@mikebather
@mikebather 10 жыл бұрын
Hi Bernard, sorry but no video at present, although it is part of the course that I teach at the University. So, if I ever get some spare time one day...
@sanjayvairsadas6955
@sanjayvairsadas6955 9 жыл бұрын
Is there any tutorial for continuous slab design
@MrSteefn
@MrSteefn 10 жыл бұрын
thank you .Really appreciate your help.
@Baelon903
@Baelon903 8 жыл бұрын
how did u come with the curtailment of H8
@mikebather
@mikebather 8 жыл бұрын
Hi John Lee Baelon, I think that you are referring to the curtailment of the H12 mid-span reinforcement. The bending moment that these bars are designed to resist only exists at the mid-span of the slab. This bending moment decreases to zero at the supports and so the bending reinforcement here (at the supports) can be greatly reduced. I have used some old guidance from the UK, however this should be appropriate for anywhere really as concrete is concrete. "50% of the mid-span bars can be stopped short of the support at a certain distance from the centre line of the supporting wall (i.e. within 0.08 x span)".The final dimensioning of reinforcement is generally done by a detailer - who has detailed knowledge of this kind of thing. I hope that this helps, Mike
@gigia37
@gigia37 10 жыл бұрын
hello, could you make a video of how to design a two way concrete slab?
@mikebather
@mikebather 10 жыл бұрын
Hi, my current plans are to do some more analysis videos with frames and beams. Thanks for your suggestion. I may get around to two way slab design in the future but please don't wait for this as it may be quite a while.
@beckzhu
@beckzhu 4 жыл бұрын
Please do a two way slab deflection check. Thanks.
@samjames2031
@samjames2031 6 ай бұрын
still my goat
@sujathajayathilaka2993
@sujathajayathilaka2993 4 жыл бұрын
thank you sir.
@mer19887
@mer19887 7 жыл бұрын
Wow awesome
@wdalrawi88
@wdalrawi88 10 жыл бұрын
Very clear and helpfull, what if the designed shear is greater than the resistant oncrete capacity how the procedures will be and also for the span/effective depth ratio >30
@mikebather
@mikebather 10 жыл бұрын
Hi, if the applied shear force exceeds the resistance of the concrete, it is best to start again with a larger beam. Not sure what you mean about the span/d ratio.
RC Slab Design EC2 - Worked example - Bending reinforcement
14:57
Mike Bather
Рет қаралды 179 М.
Creative Justice at the Checkout: Bananas and Eggs Showdown #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 34 МЛН
Twin Telepathy Challenge!
00:23
Stokes Twins
Рет қаралды 137 МЛН
Deadpool family by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 5 МЛН
Basics of Structural Design Load Calculations | One-Way Vs Two-Way Slab
8:01
The Structural World
Рет қаралды 148 М.
RC Beam Design EC2 - Worked example - main reinforcement
14:47
Mike Bather
Рет қаралды 196 М.
Punching Shear
15:18
Pádraig Sweeney
Рет қаралды 46 М.
Design and Construction of Slabs-on-Ground - Applying ACI 318
18:30
American Concrete Institute
Рет қаралды 19 М.
RC Beam Design EC2 - Worked example - design shear reinforcement
13:24
RCD:- One way slab design / design of a one way RC slab.
17:52
Suliman Khan Academy
Рет қаралды 329 М.
Slab Design Accordance with Eurocode 2
28:20
ANIS AZMI
Рет қаралды 25 М.
Pad Foundation Design | Punching shear check Part 2.
10:53
Structural Engineer Calcs
Рет қаралды 21 М.
RC Beam Design EC2 - Worked example - minimum shear reinforcement
12:29
Deflection of Beam and Slab | Eurocode 2 | 8 Steps to Check
14:42
Shefden Academy
Рет қаралды 6 М.
Creative Justice at the Checkout: Bananas and Eggs Showdown #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 34 МЛН