NAVIEN COMBI BOILER GAS LINE INSTALLED VIEGA MEGAPRESS

  Рет қаралды 9,174

Chuck Barron

Chuck Barron

Күн бұрын

Пікірлер: 91
@floydalbright1214
@floydalbright1214 5 жыл бұрын
Love it Chuck ,you don't leave anything out (fight with a pipe wrench and fall off of bucket). It's a real world out there.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
pissed i missed the shot.....could of been classic
@floydalbright1214
@floydalbright1214 5 жыл бұрын
@@ChuckBarron maybe so someone doesn't cut into a gas pipe thinking it's a water pipe.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
never thought of that....its a long shot but anything is possible. we all know old galv pipe is dark grey for sure. but still possible....just like black pipe may be a heat line...always trace out your pipes apprentices...ha
@patricksimone1238
@patricksimone1238 5 жыл бұрын
Hey chuck finally used mine last week,I will never turn a pipe again lol that thing was a dream bro,and fittings are worth the money because it’s saves you so much money in time
@ChuckBarron
@ChuckBarron 5 жыл бұрын
you are not kidding. its the dream.
@angiemoses130
@angiemoses130 5 жыл бұрын
Spending the next 2 weeks with my daughter. Merry Christmas to yall.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Awesome! Enjoy and Merry Christmas.
@mikev.1034
@mikev.1034 4 жыл бұрын
I really enjoy watching you work while I sit here & drink my coffee in these early mornings. 👍
@ChuckBarron
@ChuckBarron 4 жыл бұрын
Morning! Lol.
@anthonys.5653
@anthonys.5653 5 жыл бұрын
Nice work Chuck!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Thanks Anthony.
@hercorock123
@hercorock123 5 жыл бұрын
Yes Palermo’s was one acct we used a lot Norwood branch and Clifton. When first started out went to there Fairview branch which was the first.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
ok nice.
@BeulahRWalker
@BeulahRWalker 5 жыл бұрын
What’s up I’m studying for My Rigging Midterm Next Week. So glad this Video pop up 💦💧
@ChuckBarron
@ChuckBarron 5 жыл бұрын
hit the books....and good luck
@J-Colt
@J-Colt 5 жыл бұрын
Nice work Chuck! I've been watching vids on HE boilers last few weeks. I love the technology but since most parts inside units need to be ordered when they go bad I'm not sure I would own one. I'm sure before long it won't be as much an issue as now. Thanks for sharing!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
its like a rocket....so complicated. I really need to get to school on these naviens. its coming some day.
@georgefolgers8731
@georgefolgers8731 5 жыл бұрын
Difference between glavernized versus black pipe for gas supply line -- Please help,, As older type of buildings had galvanized in larger diameter for drainage, such as 1 1/2 & above,, Additionally occasionally,, galvanized supply lines , for toilet supply lines , in four story walk ups. Was always steered towards black pipe, is there a code difference, or why the preference. We have Always used Pipe Dope. Second question,, went to viega megapress seminar, and they stated only 5 year warranty on their fittings.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
We must use galv outside here because of salt air. I just use it everywhere. my choice. we can use black iron inside too.
@itas0r
@itas0r 5 жыл бұрын
Those Navien combi units have an automatic feeder right? It looks like you have both a regular feeder AND the automatic feeder hooked up? Is that required?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
yes both....you need one on unit and one on loop.
@hercorock123
@hercorock123 5 жыл бұрын
Love the Navien combos they remind of the Celtics made by hydrotherm back in the early 80s I used to put in.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Yes I like them too..I use to work on palormo's back in the day. I may of spelled it wrong.
@armandomadrigal9793
@armandomadrigal9793 5 жыл бұрын
Cb, im lovin that mega press. Thats going to be my next toy
@ChuckBarron
@ChuckBarron 5 жыл бұрын
game changer for sure.
@snigie
@snigie 5 жыл бұрын
We have a Teflon tape (we call it ptfe) the regular type isn’t allowed on gas, but a thicker type called one wrap it is allowed. That’s in the U.K. anyway
@ChuckBarron
@ChuckBarron 5 жыл бұрын
ok cool.....thanks snigie
@zakkmon123
@zakkmon123 5 жыл бұрын
Here in the states any product used has to be a reference standard per the International plumbing code or unified plumbing code. Depending on the state and code and amendments it adopts.
@ernestrhoades5147
@ernestrhoades5147 5 жыл бұрын
I really love that nice hole repair behind you, looks like your polishing a real turd there.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
ya that patch is coming in old chimney. they should of patched before hand. No the place is turning out nice..heater room gets budget cuts...lol
@MoneyMarcMes
@MoneyMarcMes 5 жыл бұрын
So what is the difference in durability using standard black gas pipe vs Galvanized?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Nothing...Its purely my choice only because I use it outside which is code here. I only stock galv..which is just easier for me for the interior jobs which black iron can be used.
@hercorock123
@hercorock123 5 жыл бұрын
Nice work
@ChuckBarron
@ChuckBarron 5 жыл бұрын
thanks jeff
@keithjackman1
@keithjackman1 5 жыл бұрын
HI CB , Great vid , MERRY CHRISTMAS …… ps what gas pressures do you work with ?? .
@ChuckBarron
@ChuckBarron 5 жыл бұрын
its 2psi here at the fixtures....high pressure at the meter...entire area being changed from low to high pressure........town by town.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Merry Christmas to you also.
@hercorock123
@hercorock123 5 жыл бұрын
Mega lock is my best friend !!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Mega baby.
@roberttownsend9139
@roberttownsend9139 5 жыл бұрын
Why didn’t you use copper going to the expansion tank. Instead you used galvanized pipe that can rust ?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I have always used iron pipe for strength. Never had a problem. I even used black iron pipe in the past.
@isidrorenteria4415
@isidrorenteria4415 5 жыл бұрын
Can you twist your mega fittings ones they pressed?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Isidro, No you can not.
@patricksimone1238
@patricksimone1238 5 жыл бұрын
Chuck you’re taking a beating on this one lol
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I missed the shot....i need a helmet...
@anthonysloan4129
@anthonysloan4129 5 жыл бұрын
Merry Christmas CB!!!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Merry Christmas to you also.....
@alexstoles1339
@alexstoles1339 5 жыл бұрын
Good job cb.. theres more than 1 way to skin a cat. Lol. Merry Christmas to the Barron Family
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Thanks Alex....Merry Christmas to you and your also.
@sambeyer1249
@sambeyer1249 5 жыл бұрын
That so very true
@ChuckBarron
@ChuckBarron 5 жыл бұрын
thank you sam
@andyajitsingh9127
@andyajitsingh9127 5 жыл бұрын
So much easier if you use a level instead of using just your eye ? Just saying. Why didn’t you extend the gas pipe to the kindorf and you would have been able to strap the pipe to the kindorf ? A little poor planning Chuck ?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Well Andy now that you mention a level I just purchased 3 for me and the crew. What is a Kindorf? Poor plan or a change of plans its all down hill from here. Thanks Andy.
@floydalbright1214
@floydalbright1214 5 жыл бұрын
Black pipe for gas only , no galvanized allowed , Wisconsin..
@alfredvogl4052
@alfredvogl4052 5 жыл бұрын
Are you sure? Galvanized allowed national gas code. Galvanized becoming the prefered. In some areas galvanized only no black . I am not saying you are wrong many areas have there own codes. Galvanized is actually better than black. I believe areas like jersey shore are galvanized. The utility company by me only uses galvanized for there installs like meters.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
interesting how different states are with their codes.
@patricksimone1238
@patricksimone1238 5 жыл бұрын
Do the marks like on my pvc all the time with a sharpie,a 70 year old plumber told me that
@ChuckBarron
@ChuckBarron 5 жыл бұрын
oh for sure....love the old time tricks
@throttlebottle5906
@throttlebottle5906 5 жыл бұрын
or pencil if you want it to easily wipe away
@patricksimone1238
@patricksimone1238 5 жыл бұрын
throttle bottle just use a little primer and it takes it off
@bernard.biomultinet
@bernard.biomultinet 5 жыл бұрын
Je te souhaite de bonne fêtes de fin d'année
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Happy New Year to you also....thank god for google....ha
@zakkmon123
@zakkmon123 5 жыл бұрын
How was the drop test? 👍🏻
@ChuckBarron
@ChuckBarron 5 жыл бұрын
drop test?
@zakkmon123
@zakkmon123 5 жыл бұрын
Pressure test, System holds pressure with no acceptable drop for the required 15 minutes, but loses pressure at about 1lb/hour. It use to be done by the gas purveyor but now by the plumbing or gas contractor. Here down in south Florida.
@zakkmon123
@zakkmon123 5 жыл бұрын
By water column test basically...
@zakkmon123
@zakkmon123 5 жыл бұрын
Great videos by the way it’s good to see , even the most experienced plumbers. Especially different states ✌🏻. Keep it up!!!
@ChuckBarron
@ChuckBarron 5 жыл бұрын
oh the air test....my bad..yes line was tested and passed. thanks z
@jamesgillies3710
@jamesgillies3710 5 жыл бұрын
Mega press Pro press nice options.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Mega baby!
@kylemierau6367
@kylemierau6367 5 жыл бұрын
my area is mandatory Teflon, must be yellow/gas approved (or orange which is industrial grade rarely see it, for refineries mostly) 3 wraps around with an approved pipe dope as a contractor with a gas license (utility guys just use dope, fall under their own codes). if you are using 1/2" wide tape on a 2" threaded joint u gotta overlap the tape on the threads spiraling up to get that proper spread, most guys will just got get 3/4 or 1" wide rolls. see some guys try and cheat and use pink tape or white tape, they can call you out on it and make you redo the whole gas line. I will say with propress you don't have to deal with Teflon but the mega press gas products aren't in my area quite just yet just started getting propress readily available for copper, and the machines are still quite a bit to high priced for my blood.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
good stuff...interesting how different area's have different codes....thanks kyle
@786otto
@786otto 5 жыл бұрын
Seems like everyone is using sqwizi thingi fittings those days.
@ChuckBarron
@ChuckBarron 5 жыл бұрын
yes sir otto. pro press is nice.
@joshmcfate9687
@joshmcfate9687 5 жыл бұрын
It’ll work!!!! Ay what happens if you use water pro press fittings on gas? 🤙😎🏄
@ChuckBarron
@ChuckBarron 5 жыл бұрын
lol......my favorite line. it will drip....lol
@JamesBrown-db9pk
@JamesBrown-db9pk 5 жыл бұрын
ole chucky- u dont need so much pipe dope thats low press dude whers c2 and 3 they need on the job traing
@ChuckBarron
@ChuckBarron 5 жыл бұрын
school and dr. appointment on this day.....easy on the dope cb
@harrymay5511
@harrymay5511 5 жыл бұрын
Yellow tape only But I don't use it .
@ChuckBarron
@ChuckBarron 5 жыл бұрын
Nice...Harry..
@harrymay5511
@harrymay5511 5 жыл бұрын
Start tape one thread back .
@ChuckBarron
@ChuckBarron 5 жыл бұрын
roger that...thanks harry
@edulpre
@edulpre 5 жыл бұрын
you could of put your tee horizontal instead of vertical and had your dirt pocket coming off the branch and this way your valve and union and tee would of all been on the same horizontal and not in the way of the expansion tank and tanless
@itas0r
@itas0r 5 жыл бұрын
His method is better because any debris goes straight down into the drip/dirt leg. With the tee horizontal, debris would probably go right over the opening to the drip/dirt leg, no?
@ChuckBarron
@ChuckBarron 5 жыл бұрын
I really should of roughed in higher...next time.
@sambeyer1249
@sambeyer1249 5 жыл бұрын
In ga it will not pass code horizontally it must be installed vertically
@throttlebottle5906
@throttlebottle5906 5 жыл бұрын
the gas flow must make a 90-degree change of direction with dripleg underneath and never go straight across, because any debris or condensation can blow past it the other way
@JP-ce8ix
@JP-ce8ix 3 жыл бұрын
Everyone falls off their bucket every now and then.
Never Use Copper For A Navien Condensate Drain
27:15
Chuck Barron
Рет қаралды 22 М.
Navien NFC-175 combi Boiler Retrofit #1
10:31
Canuck Mechanical
Рет қаралды 91 М.
didn't manage to catch the ball #tiktok
00:19
Анастасия Тарасова
Рет қаралды 34 МЛН
Help Me Celebrate! 😍🙏
00:35
Alan Chikin Chow
Рет қаралды 90 МЛН
Synyptas 4 | Арамызда бір сатқын бар ! | 4 Bolim
17:24
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 23 МЛН
ASPE 2022 - Viega Pressing Demo
3:40
Mechanical Hub
Рет қаралды 9 М.
3 Ways to Plumb for Gas with Master Plumber Eric Aune
10:50
Matt Risinger
Рет қаралды 38 М.
VIEGA MEGAPRESS GAS INSTALLATION
19:30
Chuck Barron
Рет қаралды 31 М.
Navien NCB 240 Water Heater Annual Cleaning - Water Heaters Now
16:14
Water Heaters Now
Рет қаралды 97 М.
Everything About Viega MegaPressG Ball Valves
2:27
Viega LLC
Рет қаралды 2,5 М.
Converting a Navien NPE unit from natural gas to propane
30:26
That Tankless Guy
Рет қаралды 19 М.
B&G Recirculating pump added to Navien NCB 240 Combi Boiler
25:39
Chuck Barron
Рет қаралды 20 М.
ELECTRIC COMBI BOILER INSTALLATION (Not Easy)
28:32
plumberparts
Рет қаралды 29 М.
Navien NFC-175 Combi-Boiler Retrofit #4
20:22
Canuck Mechanical
Рет қаралды 12 М.
mega press gas line .
2:20
Rusty Valerio
Рет қаралды 625
didn't manage to catch the ball #tiktok
00:19
Анастасия Тарасова
Рет қаралды 34 МЛН