I just want to say that your videos in combination with a couple well worded articles have really taken me from being intimidated and confused by the primary/secondary terminology to properly understanding how these modulating boilers are designed to work. Thank you so much.
@unclemaple Жыл бұрын
Awesome job. Love the details and the light at the end Excellent craftsman skills !! Be very proud of your skills. Blessings
@aaddvvnnttrr5317 Жыл бұрын
as someone who just got into the mechanical world i love watching your videos and they have given me huge inspiration to do things a bit better then the rest.
@paulsmith2931 Жыл бұрын
Quality job that, I’m a uk heating engineer, so interesting to see how engineers do it in other countries, good to see you still solder, like me old school, not press, why did you have to spray up the isolating valve handles, we buy them off the shelf here already colour coded.
@Lorencem Жыл бұрын
Thing of beauty! A work of art!
@johnsiegfried8249 Жыл бұрын
Wow beautiful work
@jjlad5037 Жыл бұрын
Super nice layout!!!
@jezzaandrews19402 жыл бұрын
work of art as usual👍
@jorgegaleano65737 ай бұрын
Congratulations clean job.. if the owner is very visual they will be very happy.
@christopherwilson26062 жыл бұрын
Bat signal- how gangster! I'm sure they're enjoying the extra living space, especially in a laundry room.
@canuckmechanical64902 жыл бұрын
Indeed it was alot of fun
@petem62912 жыл бұрын
James you raised the bar just a little higher on this one
@HPL5P2 жыл бұрын
Sweet! The bat signal should be tied to the zone controller and illuminates with a call for heat. Run 24 volt LED.
@britdavis Жыл бұрын
Another amazing build. Got a part name for that brass ball valve with the pressure ports? Nice touch and I'd like to pick up a pair but have not yet found them.
@canuckmechanical6490 Жыл бұрын
Calefacto makes Them
@jorgegaleano65737 ай бұрын
Question? Why you didn’t use the feeder hydrologic inlet in the tank 1/2”
@dillpickle13085 ай бұрын
Great job on the work. I really enjoy seeing your final product. Do these systems tend to be more underfloor heating or radiator style heating?
@canuckmechanical64905 ай бұрын
@@dillpickle1308 mostly baseboard heat
@braideng8069 Жыл бұрын
Is Hydronic heating a big thing in canda?
@markhoffman2 жыл бұрын
P.S. I still think you should be painting the plywood white or light grey, instead of black. It’s light reflection will brighten up the laundry room and the client will enjoy that.
@jasdeepsinghhundal64442 жыл бұрын
can you show how did you do the venting?
@BeeBombard2 жыл бұрын
Can you do a video on an aprilair 600 humidifier install? From start to finish?
@eulaliorodriguez532510 ай бұрын
Thank you for sharing this information.
@rafaelandreano Жыл бұрын
What books or course would you recommend to someone that is willing to learn about boilers. I’m an Hvac installer
@markhoffman2 жыл бұрын
How are you controlling the boiler efficiency without the outdoor reset installed?
@wjgavin935 Жыл бұрын
i have a 175 nfc. saw video that bipassed ato feed and used a heat exchanger. is that a good application? does anyone have a plumbing diagram for that application? thanx Gavin Grand Junction colorado.
@keeganaxtell2312 жыл бұрын
great job man way to go above and beyond. How long would you say you have been installing boilers for?
@canuckmechanical64902 жыл бұрын
First job I did was a boiler so about 20 years or so
@dunkdamonk Жыл бұрын
dude i like the mercury Temp probes, but they scare me too much. seen enough of em break off when the homeowners start piling stuff around the boiler or solar thermal tanks
@JesseWeekes-mx8bv Жыл бұрын
Doi really need the Navien clean installed
@dunkdamonk Жыл бұрын
if you have cast iron pipe or radiators, then yes you should to protect your boiler. if you got a cast iron boiler, then its prolly okay. but for anything high efficiency you want the magnetite separator to protect the fancy and delicate HE boilers and their Heat Exchangers and surplus of sensors that dont work well when gummed up with sludgey magnetite
@williesinaijetti4461 Жыл бұрын
Excellent...
@chulampimable5 ай бұрын
I enjoy your videos and think your installations are excellent. However, I have a constructive comment regarding your use of the term "reverse return." I've noticed you mention it a few times. In a manifold piping distribution system, a reverse return isn't necessary a : " reverse return or first fed/last return " regardless of the supply and return placement on the manifold. This is because the loops can have different lengths, causing water to take the path of least resistance. This is why factory built manifolds ( uponor) typically have balancing devices on the return side to adjust the flow through each loop. I can assure you my friend you can not call that a reverse return piping system/layout.
@canuckmechanical64904 ай бұрын
@@chulampimable you a 100 percent correct ….thanks for the thoughts I appreciate it