"A man who works with his hands is a laborer. A man who works with his hands and brain is a craftsman. A man who works with his hands, brain and heart is an artist." I had to wipe a tear when you revealed the results. Truly a work of art.
@canuckmechanical6490 Жыл бұрын
Kind words and thankyou very much
@gabrielcoutino7277Ай бұрын
Beautiful , this is not just ‘s work it’s art
@The_headwaters_of_the_Yadkin10 ай бұрын
I found this video when I was designing my replacement system about a year ago. You do great work and inspired me to do a super-neat six zone install.
@matthockman3 ай бұрын
Beautiful. Thank you for the walkthrough. Love the personal touch with the memorial at the end. It shows you genuinely care about your customer and your work. This is the pinnacle of craftsmanship.
@TraderStig Жыл бұрын
Wow! That's some nice work with the pride to back it up.
@kingjulian4014 Жыл бұрын
Cuz this the cleanest boiler job and I am a HVAC company nice work.
@issacrobertson Жыл бұрын
You're something else man. Beautiful.
@Nova-ec4hz Жыл бұрын
Perfect installation love people being proud of their job! A thing you can do is to use only one pressure gauge and hook them all together with valves.. 👍
@jezzaandrews1940 Жыл бұрын
A work of art again.👍
@6969allgood Жыл бұрын
All round a fantastic Job , a pleasure to look at and a fantastic commentary :-)
@KarlEmig2 ай бұрын
looks great. I like the iso's with the gage port. Looking for that on my next job. thanks
@rhysdavis652511 ай бұрын
Quite literally art. Hopefully one day I can be as good as you!
@skylinelinyt Жыл бұрын
Thanks for your information. Your works are amazing.
@Sea-DoopilotАй бұрын
I have a 30x50' shop with a 6-circuit system. I just built it and only have the slab components installed, and the manifold built and pressurized. I don't have gas to the property, So, my options are propane (I will bury a tank) or electric. I also love Navien but wondered if their electric boiler would work as well as the gas? What direction would you go? It's in southern Missouri so it's not super cold there. Thanks for any help, James and great work on this one. The "for Ian" was a class act! Great work! -Brian
@canuckmechanical6490Ай бұрын
@@Sea-Doopilot electric options always work …and can be clean
@canuckmechanical6490Ай бұрын
But propane would be the best for efficiency vs cost
@Alejandrogonzalez-r3i7 ай бұрын
Got dam! A bit of passion!!!!
@mitchmass1011 ай бұрын
Absolutely amazing work
@Deep_Divers Жыл бұрын
Great videos! The only question I have is about the use of dielectric unions. Typically copper pipe is bonded to the electrical system. With dielectric unions installed at the boiler won't that break the continuity of the bond, leaving a large portion of the copper unbonded? When filters are installed I usually see a jumper to maintain that continuity or another bond established elsewhere. So, should a jumper be installed around the boiler to maintain the bond?
@timp.95824 ай бұрын
Great video, clean handsome work.
@aihf306311 ай бұрын
A work of beauty. You must the owner of the company. Your workmanship is amazing. Can I ask you a question. Where do you get your stickers
@matthewpingitore9 ай бұрын
Great job !!
@xcmskim4 Жыл бұрын
James, it seems that you've been watching Mikey Pipes. He agrees that the NFC (fire tube models) are robust and leak free. Water tube heat exchangers in general are problematic; they cannot be sealed 100% due to high temperature and high pressure operation. I personally believe Navien water tube heat exchanger have a design defect. They are an excellent company and I too really like their products. As Mikey Pipes would say, the final install came out TITS! Literally, your installs are excellent.
@canuckmechanical6490 Жыл бұрын
Great way to put it
@johnzournatzis3002 Жыл бұрын
A masterpiece in my eyes.i would have done different the placement of the expansion tank in the return line to protect its lifetime.and i would have insulation over the pipes otherwise its a masterpiece of craftsmanship congratulations i add it in favourites
@jorgegaleano65737 ай бұрын
Amazing passion sr.
@timstriff9870 Жыл бұрын
Does anyone else think he sounds like Dan Aykroid ? Sweet work indeed !
@ChuckKarl525 Жыл бұрын
Fantastic work! Please compare the NFC vs the NCB. I have a new NCB hanging in my basement and currently soldering pipes. Is the NCB a lesser boiler in terms of longevity or quality? Thank you for you videos, you are truly an artist.
@canuckmechanical6490 Жыл бұрын
The NCB is a water tube boiler vs a NFC which is a fire tube boiler ….the water tube has more restrictive passages in the heat exchanger which in no ideal in old or dirty systems ….put simply firetubes are superior
@ChuckKarl525 Жыл бұрын
@Canuck Mechanical thank you for the education. I am upgrading from oil but will be installing a new staple up system plus existing fintube with a separate circulator. I will be flushing my existing system before connecting to the new boiler. Hopefully, this is the correct approach for this installation.
@raganriley Жыл бұрын
When all the zone two pumps are closed how does the boiler know to not keep running the primary loop? How does the boiler and boiler pump know when to run?
@PJ-vp4xd Жыл бұрын
fantastic design and execution... who makes the isolator flange with port for the pressure gauge? The ones I can find only have purge ports
@canuckmechanical6490 Жыл бұрын
Calefacto
@AndrewNelson-w4o Жыл бұрын
Each of your 8 retrofit videos has been incredible. Wish you were in Washington State in the U.S. so I could hire you. My 30 year old cast iron oil burning boiler needs to be replaced, but I have propane available. Is there any reason not to replace my oil boiler and indirect domestic hot water heater with an NFC combination unit?
@canuckmechanical6490 Жыл бұрын
Nope …as long as you got good water chemistry ….on propane is fine :)
@AndrewNelson-w4o Жыл бұрын
@@canuckmechanical6490 Thanks. Propane is about $1.40 per gallon cheaper than heating oil in my area. The NFC combi unit install quote I have is about $10,000 more than a new oil boiler install. Can I make up the difference with the higher efficiency of the NFC combi unit and cheaper propane cost?
@josephthorne848 Жыл бұрын
For that Nav combi, if there was a domestic hot recirc line, what pump should you use? Would a grundfos comfort pump work?
@pitaeata8493 Жыл бұрын
great install. I'm surprised you're allowed to use loomex in exposed area; maybe upgrade to bx (armoured cable) next install.
@karimkalache712 Жыл бұрын
Hi, i jave a question. Do you raye these units for reliability? Reason i ask is that i had this same unit installed in my house and less than 9 months later have two issues with it. The first is a 351-00 error code that the company thay installed it always tries to brush aside when i bring it up. The second more annoying pressing issue is a LOUD and frequent whining noise coming from thr bottom left of the unit. This i was told is a inducer motor and they have ordered it to he replaced under warranty. But i dont know why/hiw something fails so quick on a unit that is supposed to be suitable for commercial purposes. Know im just not sure about the quality of the brand and product as a whole, was hoping to get 20+ years out of this boiler. I honestly doubt that will be the case. See my video for a clip of the noise it is currently making.
@hituw2x4 Жыл бұрын
Beautiful job! What are those pipe clamps you're using, not the split rings?
@canuckmechanical6490 Жыл бұрын
Pipe stays
@iHecToor_ Жыл бұрын
I have a quick question, how or where do connect a nest thermostat 😅
@canuckmechanical6490 Жыл бұрын
U can put them on each zone but a little expensive for doing that for zoning
@GlenS123 Жыл бұрын
Another awesome install. Brass unions far superior over dialectric unions, the gaskets is not serviceable or replaceable. They also tend to leak overtime, yet cost the same. Just my 2 cents...
@darrenthibault7396 Жыл бұрын
Wondering if the internal pump comes on when any of the other 7 pumps comes on
@canuckmechanical6490 Жыл бұрын
Yes it comes on when there is a call for heat from the taco switching relay
@TechchnologyGuruАй бұрын
What model is the circulator flange with shutoff and ports?
@canuckmechanical6490Ай бұрын
@@TechchnologyGuru calefacto
@zbess1 Жыл бұрын
Which thermostat do you suggest with the Navien NFC 200h?
@canuckmechanical6490 Жыл бұрын
I use the Honeywell T1 pro
@ComfortTechMT10 ай бұрын
Why did you choose to use circulator pumps instead of zone valves?
@canuckmechanical649010 ай бұрын
If one pump zone fails then that zone has no heat but if you use zone valves and single secondary circulator and that fails then all zones have no heat
@keyzielock9970 Жыл бұрын
Only detail I didn't like was the gas shut off that didn't look like it was full port. Still much better than CSST. Everything else is on point 👌
@tylero8595 Жыл бұрын
Looks great. Why don't you use propress? It has made our jobs quick and clean every time. Looks great though. Are you insulating?
@canuckmechanical6490 Жыл бұрын
Cuase one mistake I have to start over …with propress I can’t fix and undo a joint soldering however is very user friendly and I can alternate it ….plus I don’t want all my joints to depend on a o-ring …..dont get me wrong pro press has great benefits just not my cup or tea for hydronics ….and lastly I find things like propress, pex and tracpipe, make jobs easier and faster jobs but leads to an overall lack of craftsman ship skills and poor quality of work for younger generations …just my thoughts
@tylero8595 Жыл бұрын
@@canuckmechanical6490 Makes sense. I saw some of your other vids. You used the Taco control module on this job. On your others you used Tekmar. Why did you switch? I have only used Tekmar. Let me know. Cheers.
@canuckmechanical6490 Жыл бұрын
@@tylero8595 if you don’t try different brands u will never know if there is anything better out there :)
@abacojack1311 ай бұрын
what size copper was used in this build, for the manifolds and to supply each pump?
@canuckmechanical649011 ай бұрын
1” for main piping 3/4” for the zones
@HPL5P Жыл бұрын
Anyone in Edmonton Alberta watching that does high quality installs like this?
@RobertKiss-xc1jv Жыл бұрын
E R plumbing and heating in Calgary does. For a boiler install they might be willing to go to Edmonton sine its not that far.
@svenhodaka9145 Жыл бұрын
@@RobertKiss-xc1jvThanks, I’m in the Calgary area, I’ll check them out.👍
@scottwidrick1835 Жыл бұрын
quality!!
@ms82xp Жыл бұрын
Nice clean install. Btw, Taco is pronounced TAY-koh, not TAH-koh.. 😉
@karimkalache712 Жыл бұрын
I thought the unit would be 'overkill' for my 2200 sq ft home
@n121pp67 Жыл бұрын
The leaves are quite sharp! Did you say it’s made of sheet metal? 🙄 slicing hazard! Home owner will rip that maple leaf out in 2 minutes after the first cut.
@canuckmechanical6490 Жыл бұрын
Yap that’s why it is not in a high traffic area :)
@braideng8069 Жыл бұрын
Get a different kind of condensate neutralizer
@commonsense98098 ай бұрын
Going crazy with oversized zone pumps, not necessary for overly expensive and maintenance required systems. Wiping customers like there’s no end. I work on sky scrapers in NYC and a single pump does over 20 stories and over 1000 zones control valves. Poor customers don’t know any better, this is the problem when end users needs a heating system and they rely on a local plumbing company. Thumbs down 👎
@sudeshramdhanie62162 ай бұрын
Obviously you know NOTHING about pride in workmanship, this is not a 20 story building.