Never use Wire Nuts Again - Wago is Better Electrical Connector

  Рет қаралды 5,940,675

Silver Cymbal

Silver Cymbal

Күн бұрын

Electrical work is hard enough & wirenuts suck. They are installed wrong, overloaded & outdated. See what a WAGO connector can do and why I love these & think you will too. If you want to learn how to make electrical work easier this is the video to see. NOT sponsored in any way.
Great WAGO starter pack: amzn.to/3tb0Dcd
My wire stripper: amzn.to/3ogIbvG
Are WAGOs code approved in USA? Yes, Wago connectors meet all of the NEC code requirements regarding splicing and terminating conductors.
You must check your own area as codes vary.
This video, description and comments contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission. This helps support the channel and allows us to continue to make videos like this. Thank you for the support!
Disclaimer:
Due to factors beyond the control of Silver Cymbal, I cannot guarantee against improper use or unauthorized modifications of this information. Silver Cymbal assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. Use this information at your own risk. Silver Cymbal recommends safe practices when working on machines and or with tools seen or implied in this video. Due to factors beyond the control of Silver Cymbal, no information contained in this video shall create any expressed or implied warranty or guarantee of any particular result. Any injury, damage, or loss that may result from improper use of these tools, equipment, or from the information contained in this video is the sole responsibility of the user and not Silver Cymbal.

Пікірлер: 8 600
@SilverCymbal
@SilverCymbal 3 жыл бұрын
Thanks for watching please *LIKE & SUBSCRIBE* Wago starter kit: amzn.to/3tb0Dcd Favorite wire stripper: amzn.to/3ogIbvG BONUS: Updated Video just posted: kzbin.info/www/bejne/eGLTnqiIqMtkmdE
@mattmclaughlin7338
@mattmclaughlin7338 3 жыл бұрын
greedy bastards bought all these
@aurktman1106
@aurktman1106 3 жыл бұрын
Unavailable.
@danlux4954
@danlux4954 3 жыл бұрын
Let’s see the inside of these things. I saw a nick in the wire, not sure if that is how it connects but that doesn’t give me confidence.
@aurktman1106
@aurktman1106 3 жыл бұрын
@@danlux4954 I bought a box of them, will let you know about the quality after they get here. I have some 110V and 220V wiring to do in the workshop.
@danlux4954
@danlux4954 3 жыл бұрын
@@aurktman1106 if you properly twist the wires together the wire nut just holds on with not much damage. Had the old marrettes that had the screw in them and because the wires weren’t twisted together they weren’t making a good connection and blowing the fuse.
@IAmKyleBrown
@IAmKyleBrown 3 жыл бұрын
Anyone who uses a pipe wrench on a wire nut should not be allowed near electrical wires.
@mauryd3444
@mauryd3444 3 жыл бұрын
Or plumbing.
@elijahbaird3950
@elijahbaird3950 3 жыл бұрын
I may be mistaken. But I believe that the comment was meant to be sarcastic. As in you can overkill any simple problem. Wago connectors are overkill for any electrical job. Just like "using a pipe wrench to tighten a wire nut" would be.
@IAmKyleBrown
@IAmKyleBrown 3 жыл бұрын
@@elijahbaird3950 it was somewhat sarcastic, but also serious. I'm not saying wago connectors are overkill, I think they are actually pretty cool and to each his own to use them. What I take issue is this guy is trying to pass on false electrical advice information to try to get someone to click on his affiliate link.
@IAmKyleBrown
@IAmKyleBrown 3 жыл бұрын
@@keithdouble1440 I hope you are neither of those!
@joecrachemontange4613
@joecrachemontange4613 3 жыл бұрын
I crank em down with the 1 inch impact gun.
@jillianshoup854
@jillianshoup854 3 жыл бұрын
I've never had any probs with wire nuts. Reused plenty. You have to know how to properly use them and twist the wire.
@studdgage
@studdgage 3 жыл бұрын
Wire nuts are a pain in the ass to trouble shoot secondly wago are disconnect rated. Third the wago connectors can hold your meter for you while you push buttons. Fourth you can use them as terminal strips. My company has went straight wago we aren't allowed to use wire nuts anymore.
@kwmaris94
@kwmaris94 3 жыл бұрын
I would never use Wagus or whatever they are called!! Using them you don’t have full surface contact of the conductor where as twisting them together is more surface contact. If wires are twisted properly and then wire nut put on correctly they will unthread like a nut and bolt!!!
@JustinL614
@JustinL614 3 жыл бұрын
@@kwmaris94 They're rated. They did tests on them and the wire literally melts before the wago. You're making things up.
@kwmaris94
@kwmaris94 3 жыл бұрын
@@JustinL614 not making anything up!! Been using wire nuts for almost 40 years! Never had an issue with putting on or taking off! Not sure what you are talking about burning! That connector will burn before copper as well as a wire nut . Just by watching the video the conductor can move within the connector. Which goes back to my original point, not a 100% contact. You use what you want!
@sonsofliberty3081
@sonsofliberty3081 3 жыл бұрын
@@kwmaris94 wago is way better. They've been test by people wanting them to fail. Voltage is not a problem so contact isn't a problem. Wires do not move once they're in. When they were heat tested, the wire failed before the the wago did. You can look at it how you want, but these are far more superior than the old nuts from a heat standpoint, they're completely stupid proof, and a whole lot faster.
@poserwanabe
@poserwanabe 3 жыл бұрын
I've seen these but in decades of electrical work I've never seen a problem with a PROPERLY INSTALLED wire nut 👍
@ChristianRodriguez-ku5wk
@ChristianRodriguez-ku5wk 3 жыл бұрын
I don’t think he was only talking to the pros he was talking to the regular consumer also... that’s why he was talking slow. I’ll buy
@poserwanabe
@poserwanabe 3 жыл бұрын
@@smokeskull 🤣😂😆
@aredditor4272
@aredditor4272 3 жыл бұрын
Push connectors are the preferred choice outside of the US. Wire nuts have several disadvantages over push in connectors.
@poserwanabe
@poserwanabe 3 жыл бұрын
@@aredditor4272 assuming the wire nut is properly installed, go ahead and list them...??
@aredditor4272
@aredditor4272 3 жыл бұрын
@@poserwanabe when you twist the wire, you're cold working it to make it brittle, and it should probably all be cut off for a lasting quality connection by the next guy who has to work with it. Again, it's now the top choice outside of the US, and many US firms are also switching to push. Twisted to solid under a wire nut is garbage.
@general5104
@general5104 3 жыл бұрын
I was a journeyman electrician for over 35 years and retired a decade ago and this is the FIRST time I've EVER heard about these connectors. I'VE GOT TO FIND THESE CONNECTORS AND BUY SOME !!! THANK you for doing this video !
@lgninjalo
@lgninjalo 3 жыл бұрын
Wait until you see the quality of cordless tools we get today. I'm very grateful.
@ghostface1737
@ghostface1737 Жыл бұрын
How in the hell have you never heard of these?
@johnnieanddebbievazquez7408
@johnnieanddebbievazquez7408 9 ай бұрын
No malice intended, but that's probably why you'll remain a journeyman. Not a master is stuff like just Like these This would be something a backyard electrician. Would use because he hasn't been twisting And splicing long enough that it becomes a second nature
@Doomzdayxx
@Doomzdayxx 7 ай бұрын
@@ghostface1737 He has, he just wanted some sort of interaction with the author of this video.
@Magnum-bh5no
@Magnum-bh5no 3 жыл бұрын
Been an electrician for over 30 years and never had a problem re-using wire nuts WITHOUT cutting existing splice off, or adding another wire into the splice, I call b.s. 625 👍. 87 comments I'm a effin celebrity 🤣😂🤣
@awalden
@awalden 3 жыл бұрын
Yes! Thank you!! Being a DIY homeowner for an equal amount of time, I also call BS on this! What nonsense! Wire nuts are NOT dangerous and they don't need to be cut off and they can most certainly be reused.
@BioMess
@BioMess 3 жыл бұрын
Calling B.S. Here. Wire Nuts For The Win.
@shawnshurtz9147
@shawnshurtz9147 3 жыл бұрын
I've been JW for 17 and I can't tell you how many times I've been ti a house call for something not working because some ass hat thought you needed to use a cheater pipe to put on a wire nut cut through one wire partially then let it arc to a pile of plastic.
@OGRE_HATES_NERDS
@OGRE_HATES_NERDS 3 жыл бұрын
@@shawnshurtz9147 thats so crazy why the f would someone do that lmao
@TheBrandon164
@TheBrandon164 3 жыл бұрын
I bought 1k for industrial applications. Even with exposure of water and heat they last at least 1 year
@markied2873
@markied2873 3 жыл бұрын
Never in my life have a seen such dramatic demonstrations of wire nuts.. they work just fine
@damonluvisi
@damonluvisi 3 жыл бұрын
Lol
@carwashadamcooper1538
@carwashadamcooper1538 3 жыл бұрын
Not. Wire nuts are useful, but not In damp locations or when exposed to vibration. In the carwash industry, 99 out of 100 electrical problems are caused by wire nuts.
@markied2873
@markied2873 3 жыл бұрын
@@carwashadamcooper1538 ok, useful knowledge. Still doesn't take away his dramatic the demonstration is lol.
@dsloop3907
@dsloop3907 3 жыл бұрын
@@carwashadamcooper1538 They are available for damp/wet locations. Google them.
@williambritt5334
@williambritt5334 3 жыл бұрын
@@carwashadamcooper1538 problem with these the area of contact on the wire is very small. Twisting the wires together and then a wire nut is best way and they use tape to wrap everything up.
@mkkl1170
@mkkl1170 3 жыл бұрын
The wire nut is only as dangerous as the person installing it. Been an electrician for 25 years and have had VERY few problems with wire nuts.
@michaelangel6201
@michaelangel6201 3 жыл бұрын
Also notice how he blew pass the part in mentioning "More Expensive" also notice how he never mentioned using the proper colors of standard wire nuts is related to size and applications. All I'm saying, if you're gonna sale a product or represent a product, then talk about that product without using poor "Piss Poor" examples of what is currently 99% used, because you won't appears as credible but as cheap "Snake Oil" peddler.
@markfernandes2396
@markfernandes2396 3 жыл бұрын
@@cplcabs I agree, they also save time' and more time
@danap.235
@danap.235 3 жыл бұрын
Because electron flow occurs on the outside of the conductor there just doesn't seem to to be enough surface area contact with these splice devices with the conductor surface. Every one of these type splice devices I've removed had significant carbon build up on the conductor and the device contact point to the conductor. The splicing device has very minimal contact presence on the exterior of the conductor. I've always maintained that 5/8 inch of twist is minimum twist length to achieve sufficient surface contact to allow electron flow to under load without carbon build up. If these splicing devices came primed with some sort of carbon inhibiting grease it might work better. But I still wouldn't use them from the perspective of call backs and loss of customer confidence. Call me old fashion but electron flow is electron flow. Amen???
@marksheltonswork7848
@marksheltonswork7848 3 жыл бұрын
@@BarryPiper Remember aluminum type NM? One of the worst mistakes in electrical history.
@Trainwheel_Time
@Trainwheel_Time 3 жыл бұрын
Can't teach an old dog new tricks.
@7hefoxsin908
@7hefoxsin908 2 жыл бұрын
Another interesting feature about the clear plastic ones are that there’s a tiny opening at the back side you can insert meter leads into for testing
@SilverCymbal
@SilverCymbal 2 жыл бұрын
Absolutely. You never have to wonder if one of your wires is barely in there like wire nuts
@neplatnyudaj110
@neplatnyudaj110 2 жыл бұрын
@@SilverCymbal yaah and what about all the wirenuts previous guy installed... no, thanks.
@dllemm
@dllemm 2 жыл бұрын
You can easily put a lead under a wire nut collar to test. There is no one-fit solution, both of these have their place.
@7hefoxsin908
@7hefoxsin908 2 жыл бұрын
@@dllemm I personally don’t care which gets used, they’re both effective.
@flexedout6650
@flexedout6650 3 жыл бұрын
First of all, if you’re changing out switches or receptacles that often, you have a bigger problem. Not to mention devices don’t connect via wire nut, they have terminal screws. Once a tap is made, majority of the time it’s going to stay just like it is until then building is demolished. Secondly, not reusable??? Okay fine, sometimes they just won’t bite again, but a new one will without any problems. We all love quick connects but just twist your conductors and put a wire nut on it. And third, if it’s done right and up to code, there won’t be any issues whatsoever. Electricians don’t just walk out after finishing a job and tell the owner “hey good luck, be careful when you flip that breaker on.” It all gets tested after being installed and once power is turned on. More likely than not, if something over heats and causes a fire. It’s either a faulty device, or some shoty diy.
@petermcguine8639
@petermcguine8639 3 жыл бұрын
I use pig taild for recepticals, so in that instance I would use a wire nut. But wagos are really annoying when you're tying in a 3 or 4 gang box bc nobody makes a wago that holds 10 ground wires. But I am hardcore team wire nut
@chrisjacobsen1659
@chrisjacobsen1659 3 жыл бұрын
@@petermcguine8639 Don't the pigtails go into the screw terminals on the switch or receptacle? That's the point. Don't replace the pigtails...
@petermcguine8639
@petermcguine8639 3 жыл бұрын
@@chrisjacobsen1659 feed in and feed out go to a pigtail. The pig tail goes to the terminals. Makes its so you don't have to backstab 2 sets of 2 wire onto a single receptical in the instance of having to replace one
@BillLaBrie
@BillLaBrie 3 жыл бұрын
I change mine out at regular 50-year intervals.
@45Deere9500
@45Deere9500 3 жыл бұрын
Unless you’re living to well past 100, that means you’ll maybe change our devices two times in any one house, if you change them when you move in, and once more in 50 years.
@joelinn7328
@joelinn7328 3 жыл бұрын
Never call electrical anything “idiot proof”
@AmericanBerean
@AmericanBerean 3 жыл бұрын
True words of wisdom.
@kethf4301
@kethf4301 3 жыл бұрын
Yep. When you say something is idiot proof, somebody else is saying "challenge accepted".
@geraldeh7291
@geraldeh7291 3 жыл бұрын
I have no worries (he says as he plugs in a black wire with a white wire).
@bullfrogg4119
@bullfrogg4119 3 жыл бұрын
@@geraldeh7291 That makes it go faster!
@justaoldman5419
@justaoldman5419 3 жыл бұрын
A white wire to black wire is actually written in the code for switch Loop
@goldwinger5434
@goldwinger5434 3 жыл бұрын
Interesting, I've been using wire nuts for 40 years and I never knew that they weren't reusable.
@Drewsky840
@Drewsky840 3 жыл бұрын
He's full of shit. They can absolutely be reused
@DDracee
@DDracee 3 жыл бұрын
The nut can be if need be, he was talking about the wire tips that were in the nut. They get weakened and damaged, you'll eventually break them off.
@jeffdiedrick9462
@jeffdiedrick9462 3 жыл бұрын
They are not especially after using a pipe wrench on them⚡⚡🔥🤕
@jakebergen1837
@jakebergen1837 3 жыл бұрын
@@Drewsky840 they shouldnt be reused if possible. wire nuts stretch and bulge out when tightened so will always be a looser connection when used more than once.
@jegr3398
@jegr3398 3 жыл бұрын
@@jakebergen1837 no they dont
@68camaro18
@68camaro18 2 жыл бұрын
I am a retired electrician and this is a highly skilled trade. Wagos are ok when installing them in a low current pass through device I.e. strip fixtures. If you use them in a junction box or device box that has higher current demands like kitchen counter tops as well as entertainment center receptacles, or commercial and industrial projects and the list goes on. WAGOS WILL melt down! They were the best thing since sliced bread at my large union shop until the problem with the melting down of the wago and the insulation on the conductors. I repaired many issues from these things. We went with the tried and true wire nuts!
@jimster1111
@jimster1111 2 жыл бұрын
can confirm. as a resi electrician we only use these for recess cans only because most recess cans come with them pre installed. videos like this keep me in business tho when some DIY homeowner tries to use these when wiring 20a receptacle circuits
@MichaeljRichter
@MichaeljRichter 2 жыл бұрын
I use the Wago's regularly in industrial wiring panels at 20 amps and never had an issue. Now, on the other hand, the knockoffs sold on the online flea market sites such as Amazon and EBay are a completely different product and many struggle at 5 amps or less.
@lameassedgamecast
@lameassedgamecast 3 жыл бұрын
Moral of the story: Don't do electrical work if you have no idea what you are doing.
@sterayd
@sterayd 3 жыл бұрын
Never discourage the sense of adventure of those you don't know, most people are A holes just let the sparks flow.
@rjwiderman
@rjwiderman 3 жыл бұрын
No let them go...this will thin out the stupid.
@stroys7061
@stroys7061 3 жыл бұрын
Good safety tip.
@astromonkey2
@astromonkey2 3 жыл бұрын
@@RocafellaPlaza So how different would this video look if he just liked the product?
@lameassedgamecast
@lameassedgamecast 3 жыл бұрын
@Skylarkist Expert Your logic is flawless. Well done.
@matthewlittler8387
@matthewlittler8387 3 жыл бұрын
The youtube algorithm never ceases to amaze me.
@blazinginfinity
@blazinginfinity 3 жыл бұрын
...so you mean it's working?
@4doorsmorewhors
@4doorsmorewhors 3 жыл бұрын
Loser
@4doorsmorewhors
@4doorsmorewhors 3 жыл бұрын
Can someone explain to me what would KZbin be without them showing you videos you didn't search for ? There's something like that and it's called google
@Openreality
@Openreality 3 жыл бұрын
The one thing I've been saying about the damn red and yellow wire connector things is actually true who would've thunk it?
@aceburgers8801
@aceburgers8801 3 жыл бұрын
Get over it
@davoinshowerhandle3302
@davoinshowerhandle3302 3 жыл бұрын
Me using the same wirenut for 10 years
@itsmitch2162
@itsmitch2162 3 жыл бұрын
Literally changed out 2 furnaces today that were 23 years old and reused the original wire nuts, still good
@tomlee432
@tomlee432 3 жыл бұрын
Sir it's just fine to reuse a wire nut.they are not a one and done product. See my post to this guy's claims.
@danlux4954
@danlux4954 3 жыл бұрын
I’ve only had a handful of cheap wire nuts that crumbled. My 90 year old building still has the original wire nuts.
@dannycalley7777
@dannycalley7777 3 жыл бұрын
DSH...………….Put me down same thing !!!!!
@sideckerinc
@sideckerinc 3 жыл бұрын
I do construction in NYC for 30 years. Never waist old wire nuts. Always reuse it. So far so good!
@ivarmh
@ivarmh 2 жыл бұрын
I was using these for commercial work already back in 2009. Very handy and also nice for protecting prepared live wires before the end equipment is installed. Its also good to note that the older grey model has an indent on the back that’s meant as a guide for how long you should strip the wire to get a proper secure connection.
@ivarmh
@ivarmh 2 жыл бұрын
Hail Odin! The king of Åsgard. Chieftain of the gods. “Vanklok mann veit alt, han trur, der millom bergi han bur. Men når framandfolk honom finn, rådlaus røynest han då.» 26th verse of Håvamål
@PhillipMikeHunt
@PhillipMikeHunt 2 жыл бұрын
@BEWARE OF SEEKER FRIENDLY CHURCHES JESUS IS COMING Jesus gave up and went home long ago.
@benjamink8448
@benjamink8448 2 жыл бұрын
I also use them to protect against live wires, easily undone
@b.powell622
@b.powell622 3 жыл бұрын
I found that they are ok, but after talking with a few electricians, the wagon connector has only a point contact, used properly, wire nuts, aka, 'scotch locks ' offer a more mechanical surface contact.
@JustinL614
@JustinL614 3 жыл бұрын
I'm an electrician. As long as they are rated they perform the same as wirenuts. Electricians tend to be overly picky about weird details that don't matter.
@GnomesBeCool
@GnomesBeCool 3 жыл бұрын
@@JustinL614 agreed lol
@Rad_Triumph_765_RS
@Rad_Triumph_765_RS 3 жыл бұрын
A lever lock will always continuously apply pressure unlike a wirenut.
@helidude3502
@helidude3502 3 жыл бұрын
Tom They got a link?
@kevinsartin6059
@kevinsartin6059 3 жыл бұрын
Those wire nuts are not rated for motor connections, the wago connectors we use at work are rated for motor connections to 600v.
@AndyDillbeck
@AndyDillbeck 3 жыл бұрын
"Wire nuts are not reusable" Say what now? Apparently I've been doing it wrong for a very long time.
@SilverCymbal
@SilverCymbal 3 жыл бұрын
Manufacturers do not recommend reusing them, with the exception of flexible spring style versions vs rigid springs. Would you know the difference, don't worry no one does since the flexible ones are a tiny % of the market and even then only designed to be resused under specific circumstances, all extremely unpractical to follow. Even if you don't buy Wagos, use new connectors at least.
@jbkibs
@jbkibs 3 жыл бұрын
@@SilverCymbal oh, well if the person who wants to sell you more of their products says you should reuse them, i guess you should listen. BAHHH BAHHH (where's the hay) ;)
@tannerbruce5434
@tannerbruce5434 3 жыл бұрын
“I don’t use wire nuts I only use wagos” “What’s a wago?” “It means he’s scared of power” “Whoa better watch out there’s 120 on that wire!”
@Syrnian
@Syrnian 3 жыл бұрын
@@SilverCymbal A physically sound wire nut can be reused with no issue.
@richhagenchicago
@richhagenchicago 3 жыл бұрын
​@@SilverCymbal I disagree with your assessment that no one knows the difference, you can see the difference in the design at a glance, but you should probably not be using wire nuts or any other connector if you do not know its ratings and you should not re-use wire nuts in general. That said I use new wire nuts for all permanent wiring, but a temporary construction light setup or other temporary low current application for my own use might get some used ones from my junk bucket for economic reasons.
@taylorsutherland9447
@taylorsutherland9447 3 жыл бұрын
As a master electrician I have used thousands of Wire Nuts, as well as Wagos (both old and new style). The wagos have their place, small stranded wire and light fixtures. Wire nuts are the best connection for solid wire. The spring inside a Wago (pressure wire connector) will fail if it heats up. I dont use them on anything but control work and lighting fixtures.
@Openreality
@Openreality 3 жыл бұрын
There aren't any springs involved. It's a simple lever switch that tightens ore loosens depending upon the direction pulled. Like a light switch as a matter of fact.
@bigweek85joeyjoejoe31
@bigweek85joeyjoejoe31 3 жыл бұрын
@@Openreality The angled blade that bites into the wire is called the spring. It works like a ratchet mechanism in that it deflects when you insert the wire but bites in when you pull. The advantage is speed and simplicity of use but the price is limited connectivity. All of these quick connects only touch a small contact point on the wire. In a wire nut connection there is plenty of surface contact. At high amp draw (like a water heater or clothes dryer) this small contact area can and does occasionally overheat and fail.
@proislam1447
@proislam1447 3 жыл бұрын
@@bigweek85joeyjoejoe31 Bullshit
@bigweek85joeyjoejoe31
@bigweek85joeyjoejoe31 3 жыл бұрын
@@proislam1447 Really Pro? Then go ahead and enlighten us with your wisdom as to why it isn't so..... (crickets chirping).
@Kommunisator
@Kommunisator 2 жыл бұрын
@@bigweek85joeyjoejoe31 Wago 221 clamps are used to wire electical ovens and inverter cooking fields. So thats 3 phases of 220V/16A going full tilt - no problem at all. When I use my kitchen appliances, something like 4KW is drawn from the wall, and the Wago clamps inside the connection box don't have any problem with that. @taylor sutherland some original Wago clamps were only designed for solid wire. Newer models like the transparent ones can accomodate different types of wires though. They won't fail for years, otherwise thousands of German homes would have a problem by now. And all our electrical wiring is solid wire (3x1,5mm² as standard, or 3x2.5mm² for higher loads), I think it is even required by law.
@RTRALLDAY
@RTRALLDAY 2 жыл бұрын
Found out about Wagos when I got hired on where I am now. We use em strictly in an industrial maintenance setting. I love em. They also make em to fit size 10 wire. What we do is put the line side under the left lever, L to L. Just in case you can’t turn that circuit off, just pop out the right wire and it won’t be energized, and the other machines can keep going
@moorefilmltd
@moorefilmltd 3 жыл бұрын
I rarely have a problem taking wire nuts back off to reuse them. Usually only on smaller 22 gauge thermostat wire that was nutted outside for 25 years
@gutfinski
@gutfinski 3 жыл бұрын
There are Wire Nuts and there are wire nuts, some much better than others.
@The_sinner_Jim_Whitney
@The_sinner_Jim_Whitney 3 жыл бұрын
@@nooneyouknowhere6148 Buchanan are awful. Ideal Twisters and Wing-Nuts are the toughest, most reversible, and most heavy-duty. Buchanan ‘B-Caps’ probably account for half the failed wire nuts I’ve ever dealt with. They don’t grab as hard, and the plastic must be softer or less chemical resistant or something, because they arc out the ends/sides more often.
@GoatZilla
@GoatZilla 3 жыл бұрын
huh huh u said "nutted"
@Rad_Triumph_765_RS
@Rad_Triumph_765_RS 3 жыл бұрын
3M scotchloks can’t be removed if installed correctly as the spring with just ratchet inside the insulated shell. Also if you resume wirenuts you’re insane because now you’re assuming responsibility for a 2¢ item that is by all intents and purposes listed as a 1 time use and discard item. Can tell you’re just another hired hand and not a business owner.
@The_sinner_Jim_Whitney
@The_sinner_Jim_Whitney 3 жыл бұрын
@@nooneyouknowhere6148 They arc through because they’re softer, cheaper, thinner plastic and they degrade due to heat/cold cycles and chemical environments. I work a lot in powerhouses, chemical plants, steel mills, that sort of thing, I can’t say whether I’ve seen one fail in a commercial building. I’ve noticed the spring’s a lot easier to spin in the plastic cap in them, too. I’m not old enough to have ever installed a Scotchlock (having started my career in around 2004-5), though I’ve cut a Godzillion of them off, and they do seem like a real asspain. The Ideals are big, I’ll give you that, but man, are they tough, and when they’re put on right you’ll break a wire before you pull it out of one. I might have different opinions if I did residential work or something.
@codystewart9120
@codystewart9120 3 жыл бұрын
Anyone else just come here for the comment section? Great stuff 😂
@captain4508
@captain4508 3 жыл бұрын
Sure did. This is a joke.
@michelrea2403
@michelrea2403 3 жыл бұрын
This dude should be selling makeup 💄
@wormwoodfive398
@wormwoodfive398 3 жыл бұрын
I always use 1 hand ... other hand is only a 2nd friend
@vidard9863
@vidard9863 3 жыл бұрын
It's like watching people pretending that they don't know how to use a knife on late night tv...
@stoopidalmanac
@stoopidalmanac 3 жыл бұрын
What’s about a three way? I’m a green apprentice and know these things suck ass haha.
@PaulPaulsen
@PaulPaulsen 3 жыл бұрын
little tip for the older grey wago´s: if you want to know how long the insulation has to be cut, just turn the clamp around. there is a little shelf with a step which shows the correct length.
@zchilli0808
@zchilli0808 2 жыл бұрын
I have used a different style of “smart connector”. Not only because of the security it gave me, but because it’s just EASY! Love these things!
@meaghanhope5468
@meaghanhope5468 3 жыл бұрын
I’ve been an electrician for 26 years and have to cut off the wire nuts less than 1% of the time. The wire in the nuts is just fine to reuse and this reuse meets electrical code. The little indentations on the wire does not reduce the efficiency of the connection. Also, the smaller versions are not removable. The wires must be cut each time.
@Auburn7543
@Auburn7543 3 жыл бұрын
I'm a journeyman electrician going on 10 years of experience and I completely agree.👍
@packinaglock
@packinaglock 3 жыл бұрын
36 years in the trade and I agree. 👍
@kaloosh2639
@kaloosh2639 3 жыл бұрын
Okay so you're right ? They can be reused correct ?and still pass code? Cause ive change some fixtures (d.i.y) and just reused them didnt look bad to need to toss the inside still looked threaded and the romix ends still looked fine, but always is best gotta keep extinguishers for safes in good spots👍
@ShadowVipers
@ShadowVipers 3 жыл бұрын
@@kaloosh2639 um no, when it comes to electrical stuff, you want to have it so you don't feel need to scatter fire extinguisher across the house... That is not safe!
@chancho00
@chancho00 3 жыл бұрын
He bring up the little indentations when the actual wires are twisted together when the wire nut is just making sure they keep tightly, meanwhile those wagos just use a little sharp edge that bite the wires and create such indentation that carry all the load cause the wires are actually separated inside, this video is just a paid advertisement or just a lazy wannabe electrician.
@LMayB1213
@LMayB1213 3 жыл бұрын
We have those in a stationary light tower. Twice the lights have gone out when these cheap snap connectors have gotten hot, melted and failed. Replaced them with wire nuts, no problems since.
@richg4051
@richg4051 3 жыл бұрын
Yeah right, I believe the lesbian dude in the vid
@MichelLinschoten
@MichelLinschoten 3 жыл бұрын
@@richg4051 dude ...grow up
@baird55aus
@baird55aus 3 жыл бұрын
Then they weren't Wago brand - they were copies.
@michaelszczys8316
@michaelszczys8316 3 жыл бұрын
Only time I have trouble with wire nuts is A. They are way wrong size. B. I am trying to cram too many wires in one. With these it can open up brand new opportunities for trouble. Sounds like a winner.
@mrjakobt
@mrjakobt 3 жыл бұрын
Definitely not Wago then.
@mattmclaughlin7338
@mattmclaughlin7338 3 жыл бұрын
thats your fault for cutting the wires shorter
@diegosuarez1563
@diegosuarez1563 3 жыл бұрын
Yep, was cutting off more than needed.
@AB-mx9gv
@AB-mx9gv 3 жыл бұрын
Wire nuts are just a compleatly idiotic
@mattmclaughlin7338
@mattmclaughlin7338 3 жыл бұрын
@@AB-mx9gv completed out dated, like so 1800's
@rob61aaz
@rob61aaz 3 жыл бұрын
I pig tail off going to the device so if the wire gets to short like in video just replace the piggy..
@AMD1
@AMD1 3 жыл бұрын
@@AB-mx9gv Have you ever make a connection with one?
@Jakeutube22
@Jakeutube22 2 жыл бұрын
Ive been an industrial/residential electrician for over 15 years. Never once had an issue reusing wire nuts.This is the way I was taught in trade school.I have never had to cut wire down if I change something. Not one issue. These new style Connectors are nice but too expensive.
@kcjarembek
@kcjarembek 2 жыл бұрын
I agree, what a dumb video.......ive been an electrician for over 25 yrs and all those nice quick connects on new lighting fixtures are immediately cut off and discarded by our company, we have learned that they cause more problems than anything......those wago ones are a little different but wire nuts are still the best, fastest, and cheapest and we buy the more expensive ones........we must remember that a wire nut is actually connecting the WIRES together, its not relying on another piece of metal to jump the current......why add another variable if you dont have too. There is no question in my mind that a wire nut provides a superb wire to wire contact connection when done correctly.
@markrobert6817
@markrobert6817 2 жыл бұрын
Yeah never had to cut wire when reworking wire in a box. For whatever reason
@heyidiot
@heyidiot Жыл бұрын
Wirenuts are fine, if you know what you are doing. I might use a Wago if there wasn't enough length on the wire to do it right with a wirenut, I suppose. But it has never happened. I'm not made of money, so why would I buy something that is ten to fifty times the price?
@denomoable
@denomoable Жыл бұрын
@@kcjarembek because you’re using cheap chinese rubbish.
@peterlustig5545
@peterlustig5545 Жыл бұрын
New style? We use these in Germany for like 50 years or so. You can check rhe connection because they are transparent, the have small holes for testing and the time that you save using these saves you actually a lot of money. Using Wirenuts would be seen as unprofessional here.😅
@mickla409
@mickla409 3 жыл бұрын
Electrician here. Wire nuts are just fine and very safe. :)
@norbertfleck812
@norbertfleck812 3 жыл бұрын
Spring loaded connectors are even better. They are safer, smaller, provide better insulation and cannot loosen. And they are much faster to install.
@greedo2660
@greedo2660 3 жыл бұрын
@@norbertfleck812 They have their place, but it's not in a 120v single-phase system like we have in our homes here in the US. The electrical connections in them is much like those cheap stab-in receptacles that fail over time due to the lack of surface area bonded in the connection.
@norbertfleck812
@norbertfleck812 3 жыл бұрын
@@greedo2660 The WAGO connectors work fine with any Voltage up to 250VAC. And here in Europe we also use single phase systems at lights and sockets. The three phase system is mainly used for industrial power, stoves and the like. Inside a living house it's all single phase 230 VAC (which is splitted out of the three phase system which comes into the building by grounding the neutral phase). The standard fuse for a socket is 16 A and the wires are 1.5 square millimeter. By the way: The WAGO connectors are widely in use since the 1970ies and turned out to be much safer than any other connector. The wirenuts are even prohibited due to a lack of safety.
@tomwelshshore
@tomwelshshore 3 жыл бұрын
@@norbertfleck812 but the connection is a single metal spring on the wire where as a nut is wire spun together ensuring a good connection
@norbertfleck812
@norbertfleck812 3 жыл бұрын
@@tomwelshshore In the WAGO connectors there is a separate spring for every wire port on the one side, and a solid, zinc plated copper bar on the other. The WAGO connectors are certified for rocket launchpads and rocket engine test stands, while the wirenuts are prohibited even for household installations in EU.
@alsnows6021
@alsnows6021 3 жыл бұрын
says you only need a single hand, while having to use both hands. lol
@garylantz3322
@garylantz3322 3 жыл бұрын
Do what I say, not what I do ;-p
@chucknorris277
@chucknorris277 3 жыл бұрын
Snowflakes
@chucknorris277
@chucknorris277 3 жыл бұрын
Do those look like working hands to you. Lmfaoo expert bahaha
@jakefloyd8035
@jakefloyd8035 3 жыл бұрын
You can use them with one hand though he's not lying
@alsnows6021
@alsnows6021 3 жыл бұрын
@@chucknorris277 Yuup, knew you had to be a 12 year old or a grown man baby.
@jenniferwhitewolf3784
@jenniferwhitewolf3784 3 жыл бұрын
I love how he cuts 2" off illustrating the trim loss with each modification. Last 300 or 600 times I changed an outlet or switch, I used the screw lugs on the outlet or switch, not opened up wire nuts. A solution for which no problem exists.
@AnUnapologeticApologist
@AnUnapologeticApologist 3 жыл бұрын
If you've changed 300-600 receptacles but never had to strip wire, that's very concerning. Please tell me you're not wiring burnt wires to new receptacles? Receptacles have a tendency to burn up wire over years of use depending on the load drawn. Vacuum cleaners, for example, have a tendency to burn up receptacle wires because they draw high amperage on start and pull a lot of power in general. If you're never touching connectors then this video is not for you. I'm in commercial refrigeration, I'm constantly cutting wires and reconfiguring electrical. Wagos are all I use.
@MisterMosfet
@MisterMosfet 3 жыл бұрын
Is it actually legal to use these on mains wiring where you guys are from? Seems very dangerous as a lot of other countries have outright banned the use of any friction-fit terminators.
@AnUnapologeticApologist
@AnUnapologeticApologist 3 жыл бұрын
@@MisterMosfet what do you mean by "mains"? Are you referring to supply from a breaker? These connectors can house up to 12awg maybe 10, but that'd be max for wire size. They're rated for 32 amps and 600 volts, but can handle over 100amps and stay cool, with the insulation of the wire burning off before the connector burns up. You'd never put them on anything that high amperage anyway though because the wire would never fit. I use them for control wiring, adding components to circuits, any low voltage application (120v, 208 single phase, 3phase 208). They're amazing for troubleshooting equipment because you can splice a wire and tie your meter lead into a 3 bay to monitor voltage. The have a ton of uses. I've seen people connect wire nuts poorly causing them to get burned up. Can't really do that with these, they're idiot proof. On R290 refrigeration systems it is illegal to put anything other than wagos on wires because wagos are anti-arc.
@awalden
@awalden 3 жыл бұрын
I know!! Isn't that ridiculous?? Totally absurd! And the comments here from the "defenders" and "fans" are comical!
@n8r8ts41
@n8r8ts41 3 жыл бұрын
@@AnUnapologeticApologist vacuum cleaners do not burn up receptacles unless the vacuum is messed up. Receptacles, conductors and overcurrent protection devices are all specd to perform at a specific amperage, so the only burning that can happen will be due to loose terminations raising the current, or bad motor in the vacuum drawing an overcurrent.
@srmofoable
@srmofoable 3 жыл бұрын
You also have to think of the universal nature of wire nuts. Basically 2 sizes will cover 99% of interior residential wire combinations. With a wago you need a different part for 2,3,4,5,,etc wire junctions or you are throwing money away. Where wago do shine and where I like to use them is inside custom equipment panels. They're great inside cnc boxes and make for a tidy setup if the DIN rail is already full
@rustusandroid
@rustusandroid 2 жыл бұрын
Plus Wago's are massively expensive compared to a single wire nut.
@fredrikfjeld1575
@fredrikfjeld1575 2 жыл бұрын
Wire nuts haven't been used here for 10 years or more. Wago all the way. You have to think about Troubleshooting or when the customer suddenly wants more stuff connected as well. We just threw out thousands of wirenuts thwt had been laying around unused
@fredrikfjeld1575
@fredrikfjeld1575 2 жыл бұрын
@@rustusandroid wago are probably 3 times as expensive, but also 3 times easier to use, 100 times easier to Troubleshoot if something is wrong and 6 times as easy to connect something new
@narmale
@narmale 2 жыл бұрын
And lights, they are blistering fast for can lights in housing
@narmale
@narmale 2 жыл бұрын
@@fredrikfjeld1575 nah, 10 times... 221 3 wire wagos here are, at the cheapest, .25 cents if you buy bulk... the absolute best wire nuts can be bulk purchased for about .017 cents... its not even close, and most places are charging 1.75 EACH for wagos.... outrageous
@Playgun10
@Playgun10 3 жыл бұрын
Contractor used these on new commercial lighting install, hundreds of lights. Less than two years all these connections started to fail. It’s been a maintenance nightmare.
@robertlaw4073
@robertlaw4073 3 жыл бұрын
That was my thought exactly. My assessment is that unlike a wire nut, which when installed correctly, acts passively in the system - the connection is with the wires - this appliance actually contains the current the carrier and will be prone to failure, particular as quality for generic connectors of the sort start coming out of Asia on the cheap. Just like we see blade contact receptacles passing through big-box home improvement stores that fail within a year due to low quality control. Never should happen. I can count number of receptacles over 40 years old that I encountered that failed due to poor mechanical contact / arcing on one hand. Not true about stuff procured in past 15 years... always cutting cost.
@alcozerj
@alcozerj 3 жыл бұрын
This video reminds me of the 'As Seen On TV' ads! 😂
@AB-nb2ic
@AB-nb2ic 3 жыл бұрын
Was about to say the same. Absolute joke, making up problems that don't exist
@linemanap
@linemanap 3 жыл бұрын
I've seen a lot of apprentice's mess up putting wire nuts on in all kinds of ways that's why proper training is done. I can only imagine how many home owners have made shoddy connections over the years.
@BlackEpyon
@BlackEpyon 3 жыл бұрын
I'm a DIYer. Keep training those kids properly. If they don't know how to use a wire nut properly, they've got no business being inside an electrical box.
@proislam1447
@proislam1447 3 жыл бұрын
Yes, all the millions of loosened wire nuts have not been tightened properly? Bullshit
@dimension85
@dimension85 3 жыл бұрын
Copper contracts and expands under load which will eventually loosen the contact point to the conductor. Wagos are fast and easy but a proper wire nut connection is a much more solid compression connection.
@ClosestNearUtopia
@ClosestNearUtopia 3 жыл бұрын
They are spring loaded and will compensate for that, the plastic itself will detoriate over time and then the housing pops open due to the springload.. then you have a real problem goin on. Noticed or unnoticed.
@Birdman_in_CLE
@Birdman_in_CLE 2 жыл бұрын
Wago made their name with, and have been used in, industrial applications, for several decades. They are used in household systems in Europe for the past 15 that I am aware of. This style is no more or less prone to failure than any other.
@anthonysinclair5721
@anthonysinclair5721 3 жыл бұрын
I'm completely confidant in the approx 750,000 wire nuts I've installed in 30 odd years!👍
@ProctorsGamble
@ProctorsGamble 3 жыл бұрын
I’m an electrician with 40 years in service. WAGO is a German brand. In Europe voltage is 220 volts to ground. These work great there but with our lower 115volts l am concerned with the limited contact surface area of these. That’s the reason I never once used “quick wire” devices in my career! I only use these for connection of fixtures and only if they come with the fixture because they save my precious Wingnuts for more important jobs lol.
@anthonysinclair5721
@anthonysinclair5721 3 жыл бұрын
@@ProctorsGamble I'm not sure of the internal construction of the quick wire portion of regular household recepticals but I figured they may be similar to the old Wagos and I remember more than a few quick wire recepticals failing and becoming intermittent and a real pain to troubleshoot ; the newer Wagos seem to have a much better wire gripping mechanism though. I'm good with my wirenut method. 😎
@davidalbert6030
@davidalbert6030 3 жыл бұрын
That’s fucking wonderful. 750,000! Wow. Amazing. That’s around a dozen an hour. Your woman is a very lucky gal. Looking forward to the parade when you hit 1 million.
@chipsammich2078
@chipsammich2078 3 жыл бұрын
I think your over exaggerating by atleast a half million
@Leebetter
@Leebetter 3 жыл бұрын
I've only come across these, or ones similar, in troffers after a ballast job. Some caught fire, but was contained. Simple to cut them off and use wire nuts with the new ballast install.
@BlackEpyon
@BlackEpyon 3 жыл бұрын
I'm only a DIYer, but I never trust quick connects for anything at line voltage. Low-voltage, LED or audio wiring, sure, but not at line voltage. IMO, if you don't know how to use wire nuts properly, you've got no business being inside an electrical box.
@jayjonassen2256
@jayjonassen2256 3 жыл бұрын
Same. I was a journeyman at 17, masters at 19. Wirenuts are a much superior connector. The industry should have learned their lesson from back-stap devices that burnt down countless trailer houses
@TheAspen31
@TheAspen31 3 жыл бұрын
@@jayjonassen2256 Where? We do a 4.5 year apprenticeship in Canada.
@mrjakobt
@mrjakobt 3 жыл бұрын
@@BlackEpyon Most electricians in Europe haven’t touched a wire nut in well over a decade. I guess those aren’t professionals then.
@BlackEpyon
@BlackEpyon 3 жыл бұрын
@@mrjakobt Europe does a lot of things funny.
@The_Story_Channel
@The_Story_Channel 3 жыл бұрын
Been using wire nuts since the 80s and my father and uncle since the 70s, we call them marrettes here in Canada and they are perfectly fine if you use the right size and install them properly. You very seldom have to undo a wire nut, you don't replace switches and receptacles that often. I will also argue that you get a much better surface connection with wire nuts, and yes, you should twist the wires together before twisting a wire nut onto them. I would use a wago connector but I would only use them on low voltage fixtures.
@justinogle150
@justinogle150 3 жыл бұрын
a lot of 2x4s i've gotten actually come with wagos
@mrjakobt
@mrjakobt 3 жыл бұрын
My stove is connected using Wagos. No issues whatsoever. The‘ve been the standard in Germany for decades and I’ve not seen a single one fail.
@markwilliams4525
@markwilliams4525 3 жыл бұрын
I'm with you 100% wore nuts with twisted wires has more surface area which means less heat
@VengaboysFansiteEI
@VengaboysFansiteEI 3 жыл бұрын
@@markwilliams4525 they make wago's rated to 30 and 50 amps.
@markwilliams4525
@markwilliams4525 3 жыл бұрын
@@VengaboysFansiteEI I've heard of them but never used them. They remind me of a back wire outlet where they wouldn't have the surface area or contact pressure of the screw, seems to me a wire pre twisted with a wire nut screwed tight would provide better surface area contact and pressure meaning less heat
@killsalltires156
@killsalltires156 3 жыл бұрын
Lucky my Klein plyers allow me to redo a splice without cutting the wires. This is good for do it yourself or for lighting, but box splices should aways be spliced proper for 100 years of no issue! Signs of melted marrets are a sigh of overloaded wire and not a bad splice. I am a master electrical contractor of 29 years.
@Check7his
@Check7his 3 жыл бұрын
Yea wire nuts are the way to go. Expansion and contraction of the wire will cause loose connections in wagos.
@happyfamily7035
@happyfamily7035 3 жыл бұрын
There is so much misinformation in this video. It gave me a headache.
@JorgeAMG187
@JorgeAMG187 3 жыл бұрын
Wire Nuts is literally Stone Age Technology and so unsafe if used Wrong. Nothing can beat Wago and the argument that Wires get loose is just bullshit.
@Check7his
@Check7his 3 жыл бұрын
@@JorgeAMG187 I can pull wires out of wagos. I can't pull wires out of wire nuts. And yea heating and contraction of copper over time cause by load changes over time can cause a loose connection in a wago.
@JorgeAMG187
@JorgeAMG187 3 жыл бұрын
@@Check7hisWith enough Force i can Pull a wire out of a Wire Nut aswell. Thats not a Argument. It takes 10kg of force to push a wire out of the Wago which is alot
@The_sinner_Jim_Whitney
@The_sinner_Jim_Whitney 3 жыл бұрын
As an IBEW journeyman inside wireman, I’ve used about a billion wire nuts and seen VERY few failures. I reuse them constantly, as does every other electrician in the world. You can absolutely connect stranded and solid wire with wire nuts. Wagos fail all the time, too many parts (potential points of failure) for something that cheap. They’re pretty good for low voltage, low current applications like inside LED light fixtures and such, but wire nuts totally kick their ass in every conceivable way for general use.
@JustinL614
@JustinL614 3 жыл бұрын
You've never had the spring pop out of a wirenut? The wago is just basically a tension clip. It is more than likely the people installing them were doing it incorrectly, which of course is a problem because a product should be easy to use by alot of people.
@The_sinner_Jim_Whitney
@The_sinner_Jim_Whitney 3 жыл бұрын
@@JustinL614 I have, and when it does it’s obvious and happens right there before your eyes where you can fix it. Wagos rattle apart with vibration and such. With a wrap of 33 around the base of a wirenut, they’re good enough for motor leads or anything. One thing I’ll give Wagos, they usually don’t cause fires when they fail. They just stop the connected equipment from working. Not exactly acceptable in powerhouses, chemical plants, hospitals, etc. where I work. A PROPERLY INSTALLED (most aren’t) wirenut will last 30 years or more with absolutely no issues whatsoever.
@subiemon
@subiemon 3 жыл бұрын
i felt like i just watched a infomercial for a product that i really don't need, i have been using wire nuts for many years and never had any problems with reusing them ever...
@OttoByOgraffey
@OttoByOgraffey 3 жыл бұрын
I've reused them for years as well. But I have had some that weren't reusable.
@ronb6182
@ronb6182 3 жыл бұрын
Same here. It's just a sales pitch and if you don't know how to connect two or more wires together then you should not do electrical work. I been using them for years and never had a problem. I rather use gorilla nuts. That's what we use in our air machines where I work. He has the date wrong IDeal bought the patient in 1946. And called them wire nuts. Me and my father rewired a farmhouse and a lot of the junction boxes had wires soldered and wrapped with friction tape. The old black tape that was sticky on both sides.
@jonathansirmons7932
@jonathansirmons7932 3 жыл бұрын
You're not supposed to reuse them or the portion of wire that was scarred.
@OttoByOgraffey
@OttoByOgraffey 3 жыл бұрын
@@jonathansirmons7932 I'll remember that the next time I re-use them and the portion of the wire that was scarred.
@ronb6182
@ronb6182 3 жыл бұрын
I must have missed something. I have a bunch of yellow wire nuts that I took off when I did the LED light conversion I probably won't use them. I used the orange ones when I installed the LED lights.
@KidsCampbell
@KidsCampbell 3 жыл бұрын
I work for an electrical contractor and we have tried Wagos and keep going back to good ole tried and true wirenuts. Anything where you push a wire into something that is supposed to hold it can be a failure point. Like the push in slots on outlets and switches they are more problem then they are worth. Atleast with wirenuts, if done correctly it wraps the wires around each other at the end it helps hold them together.
@Lugnut64052
@Lugnut64052 3 жыл бұрын
Exactly. I've fixed open circuits several times because the wire stabbed into the back of a receptacle or switch finally lost tension and went open.
@GODwithus73
@GODwithus73 3 жыл бұрын
In a perfect world when you never have to reopen a box cause a mistake they might work,
@computec1993
@computec1993 2 жыл бұрын
In Germany (the origin of the Wago Connector ;-) ) we usually don't use the "lever" type wago on solid copper wire. We use Wago type 2273 for that. The type 221 (lever) is used for stranded wire, or joining solid with stranded.
@petermuller4322
@petermuller4322 2 жыл бұрын
Just wanted to ad that in Germany Wago is most commonly used-has been so for years.
@rfreaky4717
@rfreaky4717 2 жыл бұрын
Its really depending on what you do. I mostly carry around the 221 because they can do everything and are easier to remove but the 2273 are much cheaper
@blazellin7626
@blazellin7626 3 жыл бұрын
This man is a salesman. Wirenuts work fine. I’m an electrician of 18 years
@samuelswettenham161
@samuelswettenham161 3 жыл бұрын
Yep, dumb product. Have fun trying to fit these things behind GFCI outlets, get yourself another box to stick in your bag to organize the 5 different sized connectors you gotta constantly restock. Also I highly doubt their efficacy on stranded wire. I'll stick with my tans thank you very much.
@FrannyWard
@FrannyWard 3 жыл бұрын
41 years here and yes, Wire Nuts work fine. I do have some Ideal brand connectors like these. Prefer the Wire Nuts and twist my wires first.
@SmallSpoonBrigade
@SmallSpoonBrigade 3 жыл бұрын
@@FrannyWard I'm curious why folks don't think they need to twist the wires first. I'm personally far more worried about stress fractures in the wires from bending the wires to fit them in the box than getting a good secure connection with a wire nut. I don't think I've ever had a problem with it.
@FrannyWard
@FrannyWard 3 жыл бұрын
@@SmallSpoonBrigade Well I was taught that way in 1979. And today at 59 years old and having my own business off and on for thirty, I don't trust the wire nuts alone. Besides, on some jobs I come across in offices, I have to change out a device and when removing the old receptacle, if the pig tail wires for it that go to the feed in and out are twisted, I can remove the nut without breaking the circuit. If the wire nut was just put on without a real twist, I could lose either the hot or neutral on the whole circuit, pissing off a lot of people who's desktop computers just shut down. I can twist up to four conductors with a pair of nines and trim to fit a wire nut blindfolded. But, hey. If these new fangled connectors do the job and are cost effective and UL listed? I'm all for them.
@TripleAstyle1
@TripleAstyle1 3 жыл бұрын
@@FrannyWard they are not cost effective
@36736fps
@36736fps 3 жыл бұрын
I use Wago connectors only for ceiling lights where ease of use and speed is important and the amperage is low. I never use them elsewhere because a twisted connection with a wire nut has far less resistance. Note that wire nuts are more of an insulator for a twisted connection and are not really intended to hold the connection together - that is what the twist is for.
@julianreverse
@julianreverse 3 жыл бұрын
Wrong! It has no resistance at all.
@andrewsandefur7715
@andrewsandefur7715 3 жыл бұрын
@@julianreverse where’s the basis for your statement? If a splice is properly made then the wire nut isn’t even necessary. It’s there to insulate the connection, not hold it together.
@MicahFunk
@MicahFunk 3 жыл бұрын
If you think about it, both views are correct, depending on the application. If you are twisting two or three 14 gage wires together then they will hold on their own if properly twisted when the nut it twisted. If you are twisting three or 4 number 10's together you're not going to get as much of a twist on the wires in the connector area and they will not hold tight as if they were 14's. Electricity takes the path of least resistance, when a wire nut is used the wires have a direct connection to each other. If these other types of connectors are used the connection has to rely 100% on the connecting device. This adds another point of potential failure to circuit.
@36736fps
@36736fps 3 жыл бұрын
@@MicahFunk If I am joining several 12g or 10g wires together I use the type of connector that uses a brass collar with a set screw in the side to bind the untwisted wires securely together, and then attach the supplied plastic cap over the connection. Looks like a wire nut but is very secure. I do use Wagos in ceiling light fixture because the Amps are low and the connection is very fast.
@elbuggo
@elbuggo 3 жыл бұрын
Far less?
@jeffdyrland2795
@jeffdyrland2795 3 жыл бұрын
Whenever I need a wire nut, I just look in the washing machine. Can’t do that with a wago!
@Teh_Random_Canadian
@Teh_Random_Canadian 3 жыл бұрын
I have a couple shoeboxes full marrettes from a decade of washing machine nuts lol
@AgentOffice
@AgentOffice 3 жыл бұрын
How do they get there
@Teh_Random_Canadian
@Teh_Random_Canadian 3 жыл бұрын
@@AgentOffice We use them pretty much everyday. A few stragglers end up in your pockets and they are so light you can't tell they are in there. That is until you do laundry and it sounds like a rock tumbler.
@hamburbers
@hamburbers 3 жыл бұрын
@Rd Ho holy shit 2 screw mc connectors and red heads just grow there sometimes.
@dubmob151
@dubmob151 3 жыл бұрын
I thought you meant you harvest them from the wiring of the washing machine 🙃
@tonys4396
@tonys4396 Ай бұрын
Been using wire nuts since they were invented, well, not that long, but at 75 years of age, I've been using them for too long. After seeing your video, I bought the inline WAGO connectors and their conventional connectors and just did a few electrical jobs around the house, MAN are these GREAT! THANK for your great videos!
@GrayLensman51
@GrayLensman51 3 жыл бұрын
I was an electrician for Union Electric/Ameren Energy (St. Louis) for 35 years and problems with wire nuts were virtually non-existent., even when they were reused without cutting the wire back. This is a bullcrap video.
@JustinL614
@JustinL614 3 жыл бұрын
I've been an electrician for about 10 years. My father was for 42 years. Honestly for some reason most of the older guys tend to overdo everything and are behind on the times.. which usually wastes time and money. When I first got into the business older guys were very upset about not using galvanized conduit everywhere but it's totally overkill.
@travismcfalls8811
@travismcfalls8811 3 жыл бұрын
@@tomstdenis These new wire connectors do nothing to alleviate the problem with sloppy/lazy work. You still have to make sure they wired are seated in them properly and give them a tug to make sure.
@taylorbokshowan5713
@taylorbokshowan5713 3 жыл бұрын
@@tomstdenis it’s honestly pretty hard to fuck up a wire nut also
@Rad_Triumph_765_RS
@Rad_Triumph_765_RS 3 жыл бұрын
You’re old news boomer. You didn’t hear of any problems because the place burned down before the water wagon could show up with men and buckets.
@charlessansom4849
@charlessansom4849 3 жыл бұрын
Always some smart-ass kid these days to throw that “boomer” in there. Fucking grow up!
@jameslopez4222
@jameslopez4222 3 жыл бұрын
There's a reason why this design hasn't changed since 1929.....it works.
@proislam1447
@proislam1447 3 жыл бұрын
because many dumbs accepted the faults and think it worked
@ourtime-downhere6931
@ourtime-downhere6931 3 жыл бұрын
I've been an electrician for over 20 years, wire nuts are just fine. I've had more wagos fail than wire nuts but both cases are extremely rare. Both fail due to human error, not product error. Trying to discredit one product to sell your own is the oldest and sleaziest way to do business. Don't do electrical work if you don't know what you're doing.
@detcat312
@detcat312 3 жыл бұрын
just bought house where they did all kind of crazy stuff, electric put in to shop and used wrong wire and boxes, and then found out that they put wrong wire to trailer hook up and put a junction box with connections in them under ground the hard way the one plug stopped working. It just amazes me some times what I find when doing a flip or moving into a new house, I always call some one out to check my work over, before I close any thing up. I all make sure to pull my permits and all that. When I get called for a job and people as about permits I always tell them it has to be done, then what I hate when they say so and so said I dont need one for the job that is what is bad.
@danobelelement7828
@danobelelement7828 3 жыл бұрын
God bless you fot this comment i never had problems with wire nuts i used the same one more than once and never had and issue
@apexalaska
@apexalaska 3 жыл бұрын
Yes! There is a reason wire nuts are the standard! They work GREAT!
@tomtom7955
@tomtom7955 3 жыл бұрын
@@detcat312 depends on what the job is, honestly most of permitting is about government viggs and not safety at least in my experience. There are a lot of politics at play in that world. there is practical knowledge and theory , some of these guys want to argue about stupid shit like a curtsey loop thats never been an issue in any home I wired in 20 years , it cant be a curl it needs to be an L even though logic tell us a 90 degree pinch point is gonna make a worse hot spot which is the crux of their argument against a curl. I have tied romex in knots and ran lights and tools off of it for days to prove my point to some of these guys. I actually enjoy those county and state meetings get to watch my boss raise hell at somebody else for a change lol.
@waltersobchak7275
@waltersobchak7275 3 жыл бұрын
@@tomtom7955 you said a whole lot of nothing brother.
@ronniekennedy9897
@ronniekennedy9897 3 жыл бұрын
These cool little things are fine for low voltage and low current applications. THEY ARE A FIRE HAZZARD for high voltage and high current!!! There isn't enough contact area for a real load!
@GrandmasFolly
@GrandmasFolly 3 жыл бұрын
I saw that very issue inside a panel earlier this year. A wago was used on a 20A small appliance kitchen circuit and completely melted the wago. That would never happen with a well twisted wire nut.
@slick-px4pq
@slick-px4pq 3 жыл бұрын
@@GrandmasFolly I tried these damn things many years ago when they first came out. Turned into a callback nightmare. The local supplier stopped selling them because of melted splices.
@GrandmasFolly
@GrandmasFolly 3 жыл бұрын
@@slick-px4pq They’re great for low voltage and I’ve never seen a problem inside of light fixtures but they should never be used for junctions. Unfortunately their use is gaining popularity in my area. Just this week I got a call to repair some exterior lighting on a medical building that was recently acquired by a property management company that I do work for. While investigating, I opened a gutter and found a couple hundred splices all using wagos. I’m sure I’ll be receiving a call to repair this in the future.
@heyitsme1534
@heyitsme1534 3 жыл бұрын
@@slick-px4pq yup! I do commercial work and we had a batch of 2x4 lights that kept failing and some even started smoking. Went there on a service call about and every connection with these failed after 6 months. My boss said never again. And our supplier stopped selling them because they kept getting complaints.
@ryankramer
@ryankramer 3 жыл бұрын
@@GrandmasFolly Something else must have also happened. These specific ones and brand have been stress tested to 60 constant amps for 15 minutes, getting the connector up to 270 degrees with no visible damage of any kind to the connector. EDIT ADD ON: Another test put a heat source 3 inches away from the connector and it withstood about a THOUSAND degrees before it melted. I have seen knock offs being sold on Amazon, so beware of those...
@bearlemke
@bearlemke 3 жыл бұрын
"I only have 3 inches of wire left..." well are you you going to replace that fixture or receptacle 10 more times? ...yeah didnt think so. Wire nuts win again.
@grouprocox
@grouprocox 3 жыл бұрын
@Terry Eugene yup! CEC states you should be able to remove a device without disconnecting downstream devices, pigtails ftw
@brianyoung8999
@brianyoung8999 3 жыл бұрын
@@grouprocox exactly
@MariaMaria-dw1sn
@MariaMaria-dw1sn 3 жыл бұрын
Precisely! How about having to squeeze in a LV dimmer with those connectors or the biggest home owner mess, a five gang box LV switches. I suppose the neutrals will still need a wire nut anyway. Back to Home Depot!
@the_kingdom
@the_kingdom 3 жыл бұрын
I was thinking the same thing! How many times do you need to replace it - once - if you're lucky in a lifetime.
@asakayosapro
@asakayosapro 3 жыл бұрын
Bruh, if you have a receptacle failing that often, the wire and wire nuts should be the least of your problems...
@mikiemojo
@mikiemojo 3 жыл бұрын
The NEC seems to think they're perfectly fine. I've never had them fail, but then, I actually know how to use them. But seriously,,,,,,,,, the purple gloves.......
@MichaelClark-uw7ex
@MichaelClark-uw7ex 3 жыл бұрын
Installed properly wirenuts are the best method after solder.
@maxximumb
@maxximumb 3 жыл бұрын
We don't have wire nuts in the UK, or they aren't widely used. I think it's because we have 240v which can be a bit more dangerous than the 110v in the US. There was also an attempt to market ceramic wire nuts in the 1970s, but they were very poor quality and the ceramic cracked off leaving exposed metal. The Wago connectors are so much easier to use than the UK screw fastened terminal blocks. I'll agree they are not the cheapest, but when you calculate the time saved installing them as £s/hour compared to working with the tiny screws on a terminal block, they pay for themselves there and then.
@dougjones2296
@dougjones2296 3 жыл бұрын
Been in the heating and air business for decades. And I have seen technicians wear gloves, I think it's so they dont get shocked
@vladimirpolak5203
@vladimirpolak5203 3 жыл бұрын
@@maxximumb well we as electricians in canada, often in commercial applications above 240 like 277 and 347 and still use wirenuts without problems if properly installed.
@vladimirpolak5203
@vladimirpolak5203 3 жыл бұрын
@@dougjones2296 nope those are latex gloves, and you will def get shocked
@Sawdust45205
@Sawdust45205 3 жыл бұрын
Been wiring for over 35 years the only problem I’ve had with wire nuts is having to buy the purple ones lol
@ProctorsGamble
@ProctorsGamble 3 жыл бұрын
I’m an electrician with 40 years in service. WAGO is a German brand. In Europe voltage is 220 volts to ground. These work great there but with our lower 115volts l am concerned with the limited contact surface area of these. That’s the reason I never once used “quick wire” devices in my career! I only use these for connection of fixtures and only if they come with the fixture because they save my precious Wingnuts for more important jobs lol.
@elbuggo
@elbuggo 3 жыл бұрын
@@ProctorsGamble What's the problem with the limited contact surface area? They are all identical. If it works for 1 (after extensiv testing) why shouldn't it work for the rest of them too? What specific problems have you found due to this the limited contact surface area? Why not solder the connection after twisting it with a pipe wrench, and then add a double wire nut for insulation? That would give you the best contact surface area, but do you rally need it?
@The_Conqueeftador
@The_Conqueeftador 3 жыл бұрын
@@elbuggo I can't tell if you are joking or are one of those paid bots with broken english. A pipe wrench?
@elbuggo
@elbuggo 3 жыл бұрын
@@The_Conqueeftador I added a question mark there - try again!
@angusmacgregor7217
@angusmacgregor7217 3 жыл бұрын
@@elbuggo Surface area has everything to do with it! Try pulling 200 amps through a piece of #18 gauge bell wire and ask that surface area question again!
@slick9892
@slick9892 3 жыл бұрын
After living through the disastrous "push in" wiring style receptacles, and switches in the 1980's, I'm not real excited about any connection that isn't 100% solid. These seem like they may be okay, but I would like to know exactly how they work internally, before I would consider using them. They also seem to take up additional space, which many boxes don't have a lot of. Wire nuts also are a lot less trouble, if you don't buy the cheap ones.
@dubmob151
@dubmob151 3 жыл бұрын
These lever type connectors are very different from the spring loaded push and catch types, so don't read into them based on how the spring ones work. The push types have very limited range and won't hold up long term when they lose tension and heat up from the increasing resistance.
@slick9892
@slick9892 3 жыл бұрын
@@dubmob151 I'm not comparing these. As I said, these show promise. But, I'm also not just going to start using them, based on promise. That's how the disaster in example I gave, happened. When I get some of these, and dissect them, that will probably help me decide.
@DeutschlandLife
@DeutschlandLife 2 жыл бұрын
In Germany Wago Connectors are the state of the art. You use them in the whole house installation.
@LostBeetle
@LostBeetle 2 жыл бұрын
I had two receptacles in my house almost start a fire due to backstabs. A couple others done with backstabs were redone just in case after the second one starting getting warm (with almost no load on the circuit). The first one scorched a neutral wire, turning the insulation black and made it start to flake off, I actually wonder if it combusted briefly to be honest, that's what it looked like.
@afroninjadeluxe
@afroninjadeluxe 2 жыл бұрын
​@@LostBeetle That sounds like a uninformed and incorrect installment and/or a poor quality backstab connector. A backstab Wago 773 won't have any issues - if used correctly(!!!). Otherwise, what the fuck would happen to the entirety of Europes houses, they'd burning down!?
@kubectlgetpo
@kubectlgetpo 3 жыл бұрын
"They are incredibly dangerous". Completely false statement.
@incubusga
@incubusga 3 жыл бұрын
I was confused about that claim as well- I’m just a lay man handyman / home owner. I have never run into problems that I didn’t create myself.
@jordanadams6033
@jordanadams6033 3 жыл бұрын
Anything is dangerous with misproper application😂
@curiosity2314
@curiosity2314 3 жыл бұрын
It would be nice to validate your claim as just the statement alone does not help your case. Why do you believe "they are incredibly dangerous"? I have used both methods and the both perform well.
@jordanadams6033
@jordanadams6033 3 жыл бұрын
@@curiosity2314 wirenuts aren't dangerous, bad untrained electricians misproperly setting up wirenuts are dangerous. Just the same as bad untrained electricians setting up wago connecters can be dangerous. Wirenuts are in no way idiot proof. You can have too much excess wire when connecting and cause it to go through the end of the nut, people can leave excess wire exposed at the bottom, people can improperly pigtail or connect wire. Wirenuts aren't bad, bad electricians are bad
@The_Fictionist
@The_Fictionist 3 жыл бұрын
@@jordanadams6033 you’re spot on and I think that was the (albeit poorly articulated) point of this vid. In his opinion these connectors are easier to use and slightly more idiot proof. That doesn’t mean wirenuts can’t be used safely and that these connectors can’t be used improperly.
@skipman4735
@skipman4735 3 жыл бұрын
I just installed drywall in a basement. The ceiling fixtures had these installed with temporary bulbs. I disconnected them , routed the boxes and reconnected them . Very nice and easy.
@walterbrunswick
@walterbrunswick 3 жыл бұрын
Nice! Can't wait to start using these
@jbortega1178
@jbortega1178 3 жыл бұрын
I never cut my wires when i could just untwist em...wth
@tomwelshshore
@tomwelshshore 3 жыл бұрын
Yeah if you dont leave a foot of wire what happens when he replaces an outlet 100 times
@Thunder978
@Thunder978 3 жыл бұрын
I wrap wires with aluminum foil or steel wool, then smash everything back into the box with a broken broomstick. I then check my work by spraying a bit of carb cleaner in the box and flip the circuit back on. No boom = Master Electrician. (For all the Neanderthals out there of course I’m kidding.)
@brianyoung8999
@brianyoung8999 3 жыл бұрын
@@Thunder978 sarcasm level 1000
@TheObsesedAnimeFreaks
@TheObsesedAnimeFreaks 3 жыл бұрын
Makes more sense, but of course, people are going to be "oh my god your doing it wrong." your right in certain respects, if you want a perfect undamaged lead to be the most perfect little solder you can be, sure. but if you don't care, know whatever connection you are going to be making is going to be limited far below what would even cause an issue, your most likely fine just reconnecting the wires with existing wire nuts and not caring. This works if you are I don't know installing new light fixtures with LEDs that max out at 10-20 watts. if you are rewiring an entire house, it's probably better to go in an replace all the wires anyway, because chances are it's going to be wired in a way that makes no sense from a floor plan perspective. and when you replace all the wires, you might as well use proper connection techniques that are far more secure and far more reliable like soldering or wago connectors and other junction blocks and such. makes it far easier to manage cables too..
@Thunder978
@Thunder978 3 жыл бұрын
@@tellsitasitis Hell no. Double-Sided tape with staples and penny nails sprinkled all over it.
@Billybaum35
@Billybaum35 2 жыл бұрын
I was always taught that if it's solid wire. The wire nut should only be protecting your connection not making it
@wientz
@wientz 2 жыл бұрын
give it a little extra twist to lock it though .. its more than just a cap
@boeing757pilot
@boeing757pilot 2 жыл бұрын
That's not exactly correct. The twisted wires will form oxidation over time (increased resistance at splice) and might loosen based on expansion and contraction under load. The twist on connector addresses these problems: the conductors are placed into compression and remain so during expansion and contraction. And the square "spring" inside the connector cuts into the conductors and forms a gas tight connection, preventing oxidation at the contact points. The twist on connector is definitely part of a proper splice..
@knotbumper
@knotbumper 3 жыл бұрын
Only issue is the contact surface (which is the current carrying part of the conductor and connector) is substantially smaller that when two (or more) conductors are joined with a wirenut. They are fast, cheap and popular with contractors who do residential work and are paid piece work. Several customers of the contractor I work for prohibit in their specifications Wago and similar connectors due to failures. In 42 years or electrical construction, I have never seen a wire nut go bad unless it was installed incorrectly even then, of the hundreds of thousands of wire nuts I have handled, I bet there have been less than five that had failed. true, you should not reuse wirenuts. But, in the fine print, Wagos are a one time installation also.
@Morberis
@Morberis 2 жыл бұрын
Where these excel is in controls. They make testing for faults so much easier.
@beru58
@beru58 3 жыл бұрын
The beauty of the wire nut is the HUGE contact area you get.
@zybrozer1337
@zybrozer1337 3 жыл бұрын
not needed the cable insulation burns before the wago
@johnh8546
@johnh8546 3 жыл бұрын
@@zybrozer1337 I think his point is that with the large contact area between the wires ,and the aluminum in the wire nut, you don't add in much if any additional resistance into the circuit.
@jhoughjr1
@jhoughjr1 3 жыл бұрын
as an electrinics enguneer that is the factor for me. Wagos have very little meat from what ive seen
@proislam1447
@proislam1447 3 жыл бұрын
that you do not need. As long as the contact area is sufficient, more is nonsense. This is called engineering.
@johnh8546
@johnh8546 3 жыл бұрын
@@proislam1447 that you don't need so long as the wire is in good condition. In a humid area where the wire will tarnish overtime there by increasing its surface resistance more contact area is preferable. So that years down the road you are still at a sufficient level of conductivity to ensure you aren't loosing efficiency and adding heat to the circuit. I have never regretting having a larger safety margin designed into a system. I also use 12 gauge wire on all my 15 amp circuits. Anything worth building is worth over building.
@timbosplice2460
@timbosplice2460 3 жыл бұрын
Here is a quick trick, strip the stranded cable slightly longer than the solid cable fold the stranded in half then connect the wire nut. If you do that the cable will not slide on that solid copper. Been doing that since 1999. Works great
@ildemonge123
@ildemonge123 3 жыл бұрын
Agree, that's the secret for a great connection, that's what I do on residential every day.
@stayclassic2361
@stayclassic2361 3 жыл бұрын
Comments like these are why the KZbin comment section is such a treasure
@StolenJoker84
@StolenJoker84 2 жыл бұрын
I actually have a few of those WAGO connectors. They were recommended by my local hardware store for some electrical work I had to do. Very, very handy.
@AnythingOutdoorswithSteve
@AnythingOutdoorswithSteve 3 жыл бұрын
They are great for lighting loads, but 20 amp receps, I still twist and nut. Wego has a flat bar connection point, not ideal for heavy loads.
@nikoh4591
@nikoh4591 3 жыл бұрын
Wago released few years back connectors for thick wires, up to 10AWG/6mm². Rated for 42A. Even the normal ones are rated for 35A. In Finland use nothing but Wagos (or similar off-brand ones), I love them. Easy to install, easy to change If needed. Oh yea also, wire nuts are basically banned here.
@ucnhtmenow1
@ucnhtmenow1 3 жыл бұрын
I was an electrician from 2005-2010 and I still do low/high voltage work (residential/commercial) electrical and A/V work, and I remember the first time I seen these (not the Waco ones), about 4 years ago. As soon as I looked at them, I snatched them from my buddy and asked him how come no one told me these existed and told him he had just changed my life forever. I've seen them on the shelf but never took a second look at them because I've always used nuts. The only thing that sucks is not all of them are re-usable, but they're still worth every dime. People cutting wires too short don't make me wince anymore lol.
@mr0big
@mr0big 3 жыл бұрын
All of them are reusable AFAIK. Those that don't have a lever need to be twisted around the wire while pulling gently, and they will come loose. Once you get a feel of it you could open those pretty quickly.
@macdieter23558
@macdieter23558 2 жыл бұрын
@@mr0big Pleeeease don´t twist them ever. I admit it works, but it isnt the way it´s intended to work. If you look at them closely you will find that near the end there is a hole where a phase checker screwdriver fits in. When the screwdriver is inserted completely you push it a little in direction to the end of the WAGO, that will open the connection and you can slide the wire out. Pro-tip: Pay the few cents more and buy the original WAGO, the product quality is worth it!
@rfreaky4717
@rfreaky4717 2 жыл бұрын
@@macdieter23558 as far as i know you are supposed to twist them, the hole is just to insert a volt meter
@okkrom
@okkrom 3 жыл бұрын
"Are you tired of burning down your house with those old wire nuts?" -Hi there I'm Billy Mays here with the brand new useless gadget for you!
@scullanbonecrusher
@scullanbonecrusher 3 жыл бұрын
Lmao
@james10739
@james10739 3 жыл бұрын
Ya I could see that but I think they have been widely adopted in europe and I like them they are easy but he made wire nuts look like they are not a just fine solution and in every house or building you have everything been in
@frankgonzalez24
@frankgonzalez24 3 жыл бұрын
But wait, there's more.
@momos2790
@momos2790 3 жыл бұрын
Billy May is dead...probably from fire from faulty wire nut...just sayin’
@scullanbonecrusher
@scullanbonecrusher 3 жыл бұрын
@@momos2790 maybe from a faulty wirenut installer
@itisjustacomment
@itisjustacomment 3 жыл бұрын
I like how he cuts a massive amount of wire to fit his narrative :)
@antoniocamacho4412
@antoniocamacho4412 3 жыл бұрын
All he needs to cut is the bite marks off😅
@billruss6704
@billruss6704 3 жыл бұрын
And then measures 3 inches "as the crow flies".
@Nathaniel_Peterson
@Nathaniel_Peterson 2 жыл бұрын
I noticed too, but the point remains.
@JohnComeOnMan
@JohnComeOnMan 3 жыл бұрын
Typically, you don't need to undo the wire nuts when you're changing light switches.
@thefuturegamer9451
@thefuturegamer9451 3 жыл бұрын
Sometimes you do when your replacing a switch in a house that was built around 2000 in the United States, I’ve noticed that in 20 year old houses, they have a ground in the box but didn’t connect it to the switch
@djwillx2tnb819
@djwillx2tnb819 3 жыл бұрын
@@thefuturegamer9451 replacing switches in my house right now currently actually and that’s what is needing to happen, also you do if you are adding smart switches in as well.
@muskokamike127
@muskokamike127 3 жыл бұрын
@@thefuturegamer9451 In reality, the ground is connected to the box and the box is connected to the switch so it is grounded. BUT still, you could attach a length of wire to the box's grounding screw and then the switch....
@NikoBellaKhouf2
@NikoBellaKhouf2 3 жыл бұрын
@@thefuturegamer9451 my house was built in 1997 and the wiring is acting crazy. Lights flicker fast, lights that are turned on, turn off for several minutes and back on, etc.
@jcagy2
@jcagy2 3 жыл бұрын
@@thefuturegamer9451 No need to ground a switch!
@katlman
@katlman 3 жыл бұрын
Learned about these from KZbin a couple of years ago. When I built a new workshop I used these (the new style) connectors. Much faster and simpler. The electrical inspector commented on them, saying these are much better than marettes. BTW, self taught for wiring but did pull a permit and passed the inspection with no corrections to make. Slow but steady
@kindpotato
@kindpotato 3 жыл бұрын
@@FJB2020 Yeah I've been apprenticing as an electrician and it is very straightforward. Twisting together 3 wires and using a marrette was the hardest thing I had to do. So these seem pretty awesome.
@littlejackalo5326
@littlejackalo5326 2 жыл бұрын
@@FJB2020 maybe for you, but not for the vast majority of people. 90% of my work is finishing jobs that prone thought they could do because they "watched some KZbin videos." I had 9 guys doing these types of small jobs at the beginning of 2021. Now I have 32 of my 81 guys doing this kind of work, from the people who thought they would take on a DIY remodel.
@edenhazard7597
@edenhazard7597 2 жыл бұрын
@@FJB2020 everyone who says this only has limited experience in resi lmao
@edenhazard7597
@edenhazard7597 2 жыл бұрын
@@FJB2020 im talking like you bozo lmao, theres a reason less thanhalf of all journeyman electricians pass their master test
@edenhazard7597
@edenhazard7597 2 жыл бұрын
@@FJB2020 you said electrical is pretty easy, which isnt true for high level for industrial and commercial...
@michaelkistler6885
@michaelkistler6885 3 жыл бұрын
I love the idea of them for all the reasons you listed but I'm curious to the connectivity, resistance and ability to carry load vs the wirenut.
@bas6983
@bas6983 3 жыл бұрын
Will be fine as they are used widely in western europe. The older type of stick in connectors is even older and can be found in houses as old as ‘96. (At least) the wago’s are also older than you think.
@markfiddament9383
@markfiddament9383 3 жыл бұрын
Check this video kzbin.info/www/bejne/mIGTonuvi6aso7c someone tried testing them to destruction, it took over 150 amps... the wire to the connector failed first....kzbin.info/www/bejne/mIGTonuvi6aso7c
@multitutorialguy5735
@multitutorialguy5735 3 жыл бұрын
It looks like the lever Wagos hold up to the 20-30amps the wire is expected to also hold up to. Just FYI though, Europe uses 220v (nominal) so the amps are halved compared to the U.S.
@Rad_Triumph_765_RS
@Rad_Triumph_765_RS 3 жыл бұрын
It’s better. They are listed for a greater ampacity than the wire that can be connected to it.
@ZenHulk
@ZenHulk 2 жыл бұрын
In Utah, when we remodeled our house down to the studs in 2016 and used Wago connectors, the building inspector SAID NOPE, redo it, been an electrical engineer since 1989 mostly in the military and we used them for years, but Utah said no. Have a drawer full of these now.
@dansanger5340
@dansanger5340 Жыл бұрын
Should have appealed.
@OtisFlint
@OtisFlint 7 ай бұрын
Your inspector was a moron. Would have made him show me where in the code it says they can't be used and watched him bumble nonsense lol
@TheoneStanband
@TheoneStanband 3 жыл бұрын
Those wire nuts work just fine, I'm an electrician who has been using them for around two decades and I have to say I have never had an issue with those wire nuts.
@ProctorsGamble
@ProctorsGamble 3 жыл бұрын
I’m an electrician with 40 years in service. WAGO is a German brand. In Europe voltage is 220 volts to ground. These work great there but with our lower 115volts l am concerned with the limited contact surface area of these. That’s the reason I never once used “quick wire” devices in my career! I only use these for connection of fixtures and only if they come with the fixture because they save my precious Wingnuts for more important jobs lol.
@TheoneStanband
@TheoneStanband 3 жыл бұрын
@@ProctorsGamble I've used them on both 120 volts ac and 240 volts ac. As long as you install them properly there shouldn't be any problems but people do things differently I suppose.
@fivepointbaptist
@fivepointbaptist 3 жыл бұрын
I use split bolts. Then I spray them with gorilla glue. Wrap them with painters tape. Pour on some holy water. Give em a high 5. Boom! Done!
@tsadkiel2008
@tsadkiel2008 3 жыл бұрын
Best fix ever!
@ramtek2702
@ramtek2702 3 жыл бұрын
Personally, I think that wire nuts are quite forgiving and the fact that they have been used ubiquitously for nearly 100 years supports that. Of course there's always a way to misuse anything.
@oceancon
@oceancon 3 жыл бұрын
sometimes new things can work better even though we are so used to doing things the 'regular' way. For instance I just did some new spigot connection in my house and used the shark-bite setup instead of sweating pipe. More expensive? yes but way the hell easier, safer and pleasurable. Just keep that in mind when new technologies present themselves !
@ramtek2702
@ramtek2702 3 жыл бұрын
@@oceancon You might LOVE the new fittings today but your opinion won't be valid until you know they last as long as the old method which is forever. I hope they don't leak in a year because they are not fun to replace.
@oceancon
@oceancon 3 жыл бұрын
@@ramtek2702 maybe so but they are easy to replace. If you make a mistake when installing its easy to take apart and redo. just saying dont ignore new tech just for the sake of it
@ramtek2702
@ramtek2702 3 жыл бұрын
@@oceancon I don't ignore anything but my experience with "NEW" is just some guy finding a way to show you some short term gain while concealing long term consequences that often become someone else's problem. I've heard they're very difficult to replace where sweat fittings only need to be heated. Sweat fittings are not difficult if you are patient and have the right tools & knowledge. These days people are always looking for ways to cut corners.
@chipsammich2078
@chipsammich2078 3 жыл бұрын
@@oceancon Shark bites are over priced junk
@brianthiel1488
@brianthiel1488 3 жыл бұрын
I don't do homes, but in vehicles Ive always used solder and shrink tube.
@olegs79
@olegs79 3 жыл бұрын
I've installed a gajillion wirenuts, haven't died yet.
@livenotonevil8279
@livenotonevil8279 3 жыл бұрын
Same, but I do wonder if I've left a ticking time bomb somewhere.
@davidsignor7931
@davidsignor7931 3 жыл бұрын
@@livenotonevil8279 don't know about you but according to this I have ticking time bombs everywhere
@livenotonevil8279
@livenotonevil8279 3 жыл бұрын
@Scott Jarry Aren't they a subsidiary of the world health organization?
@paulmaxwell8851
@paulmaxwell8851 3 жыл бұрын
Huh! That's nothing! I've installed 1.3 gajillion wire nuts. Still breathing!
@livenotonevil8279
@livenotonevil8279 3 жыл бұрын
@@paulmaxwell8851 I knew a guy who, after installing 1.3 gajillion of those seemingly harmless wirenuts, decided to twist 1 more on (yup, he just HAD to push his luck), and that was the end of him. He was electrocuted while being stung by a zillion hornets who had arrived to attack the fire ants that had suddenly been unleashed onto his body since they were oddly attracted to the sizzling flesh smell.
@kennethrose5422
@kennethrose5422 3 жыл бұрын
I have always reused wire nuts. I've never cut wires off either. I do like these connectors
@HUGEACT-MAN
@HUGEACT-MAN 3 жыл бұрын
And let me guess, you've had none of the problems he talked about... ya me either
@drmodestoesq
@drmodestoesq 3 жыл бұрын
People are shocked when they find out I am not a very good electrician.
@MrBen527
@MrBen527 3 жыл бұрын
Lol
@civildiscourse2000
@civildiscourse2000 3 жыл бұрын
Ba-dmp tish
@lizard944
@lizard944 3 жыл бұрын
@@civildiscourse2000 Ahh, I wanted to do that! LOL
@dersupra
@dersupra 3 жыл бұрын
good one
@kimberlyashcraft7841
@kimberlyashcraft7841 3 жыл бұрын
LMAOOOOOOOOOOOOO
@sigataros
@sigataros 8 ай бұрын
Here's why I will keep using wire nuts: - They are dirt cheap - Usually a red wire nut is good for most amounts of wire and sizes in home wiring - Wago has a current rating while a wire nut joins the wires themselves directly and doesn't have a current rating - 3:10 I'm still begging companies to make transparent wire nuts but I guess we don't have them yet however wago is still a good option Mistakes you made in your video: - 0:33 you can keep using wire with bite marks and it will be fine, it will in some cases provide better connection because the recently stripped copper is guaranteed to not be rusty, you can also twist enameled wire with a wire nut and it will make a connection due to it's sandpaper abilities - 0:42 you're wasting so much wire here by cutting the wire at the bottom of the wire nut, what you need to do is to remove the nut and cut the wire just where the copper stops being insulated (you can also use wire that is stripped, it's fine) - 1:10 yes you screw them on and you're all set, if you put them too loose then you will immediately know to use a smaller wire nut, and if it's too tight then i don't know what you are doing, pre twist if you have 3+ wires, because you probably can't hold all of them together while putting the wire on, but 2 wires is fine to not twist because the wire nut does that for you - 1:29 I can, i separate the wire then twist them back together with a linemen's pliers, not that hard - 2:16 use a smaller wire nut or solder them
@Proudielad
@Proudielad 3 жыл бұрын
Well here in Australia we have a connector called BP which is basically a screw terminal in an insulated housing. You twist your wires together, insert into the terminal, and use a Phillips or a flat to screw down and secure the connection
@sylviarohge4204
@sylviarohge4204 3 жыл бұрын
Such screw terminals have long been standard in Germany. However, these have been replaced by spring-loaded terminals in many areas. The advantage of spring-loaded terminals is that the cables cannot loosen due to thermal influences. However, this is possible with screw terminals. Temperature fluctuations change the length and thickness of the wires, but also of the holding screw. Even minor changes can cause the cable to loosen over the years, which can lead to a fire.
@tischtennistucheim
@tischtennistucheim 3 жыл бұрын
@@sylviarohge4204 plus, they are way easier to handle than the old ones with screws
@katlman
@katlman 3 жыл бұрын
In Canada, most of the screws used in electrical are Robertson’s (square heads). I swear and curse the ones done with Philips heads. LOL
@dd.4910
@dd.4910 3 жыл бұрын
Australia is actually called Stralia, just correcting you there
@slaikka633
@slaikka633 3 жыл бұрын
I've been electrician in Finland nearly 20years and never used these. Only seen when opening old junction boxes. So it's been rip here much longer 😂
@eliaswb4133
@eliaswb4133 3 жыл бұрын
+1 for here in The Netherlands.. Prehistoric wire nuts are not in use for a long time already here
@Broooski
@Broooski 3 жыл бұрын
@@eliaswb4133 Lul niet man voor fabrieken etc is het zelfs verplicht ze kunnen veel grotere vermogens verdragen dan steekwago
@laiskamies
@laiskamies 3 жыл бұрын
Yupp, whenever I see those shitty wirenuts I replace them with Wagos. And also there are Wagos for 8 wires, I would never trust wirenut to hold 8 wires.
@milankaloczi4547
@milankaloczi4547 3 жыл бұрын
It's really sad, because in Hungary we use Wago at least 5 years. Somehow, we don't use wire nuts, because if somebody doesn't had terminal block, he just twisted the cable, and put electrical tape on it.
@misterspinkick
@misterspinkick 3 жыл бұрын
I've never seen wirenutss in Germany and I think nobody is using this in Europe today. There is nothing better than Wago
@fr3ddyfr3sh
@fr3ddyfr3sh 3 жыл бұрын
In Germany we never had these weird things. Traditionally it’s a luster terminal, effectively a wago with a screw instead of a leaver.
@romend1763
@romend1763 3 жыл бұрын
Same here in France
@AngeEinstein
@AngeEinstein 3 жыл бұрын
Except nobody uses them anymore
@romend1763
@romend1763 3 жыл бұрын
@@AngeEinstein Would love to know what you use insted, but... I can assure you it's still in use in Europe.
@AngeEinstein
@AngeEinstein 3 жыл бұрын
@@romend1763 almost everybody uses WAGO connectors. Big point is that a screw connection can loosen over time but the WAGO are spring loaded so that doesn't happen. Also if you tighten a screw clamp too much you damage the wire. This can possibly "cut" a big part of the wire, creating higher resistance and therefore a fire hazard. Also the cost disadvantage of WAGO is minimal. One pcs is about 0,30€. If you factor in the cost of labor and the other benefits like full reusability, increased safety(because you can't really use it wrong) it's not bad. Other option would be the WAGO connectors where you push the wire in. Those are way cheaper but can't be removed from the wire. But you still have the benefit of easy(and idiot proof) installation and spring loaded clamping force.
@robertsparling
@robertsparling 3 жыл бұрын
Electricians in Germany don't use anything but wago anymore. I just build my house and that's all I used. Lusterklemmen are from yesterday. For my light fixtures that go from a solid wire to a stranded wire, I used the type with the levers, otherwise I used the push in type.
@TheMatz40
@TheMatz40 2 жыл бұрын
I made my professional training as an electrician/electronics engineer here at Siemens back in 1985 to 1989. So I am now more than 30 years in the business. I have never, ever heard of something called a "wire nut", nor have seen something like them in Germany ever since. We used Wagos all the time. Even insulating screw joints were considered "bungling" when it comes to electrical installation...
@Semajal
@Semajal 2 жыл бұрын
I would imagine they are just an American thing :D
@XRRS24
@XRRS24 2 жыл бұрын
Here in your neighbor country Netherlands, we use these nuts all the time. Never had any issue with them.
@TheMatz40
@TheMatz40 2 жыл бұрын
@@XRRS24 I guess, if they are used properly, they are just fine. And they seem to be not so uncommon in other countries. I just wondered, that I've never encountered them in Germany. To be honest, I just learned, that they exist.
@PeterAuto1
@PeterAuto1 2 жыл бұрын
also didn't knew wire nuts before. Looks like they aren't a thing in Germany
@Leonvolt28
@Leonvolt28 2 жыл бұрын
Here in the Netherlands wire nuts are only sometimes used for high current appliances like washing machines.
@preformancemustang
@preformancemustang 3 жыл бұрын
Wago is against building codes in my state. They clam there not Secure enough properly properly hold wires together causing shorts that lead to electric ark starting a fire. So check you code book before using them.
@robertlaw4073
@robertlaw4073 3 жыл бұрын
I could imagine the problem would be a situation where the wires actually end up holding up a fixture, so imagine someone cross threaded the bracket screws, or the nut on the threaded post comes loose over time. A properly sized connection with wire nut will, in a pinch, hold up most flush fixtures, at least so you don't have it come crashing down on your head and have a chance to get up there and fix the problem before anyone gets hurt. I would not count on a thin wall plastic box to take that weight.
@brianleeper5737
@brianleeper5737 3 жыл бұрын
What state is that?
@JustinL614
@JustinL614 3 жыл бұрын
@@robertlaw4073 Don't do that unless it's the ground. I've seen guys pull wires out of the fixtures that way.
@imark7777777
@imark7777777 3 жыл бұрын
@@robertlaw4073 it seems like you're saying my hypothetical light fixture hanging from the ceiling shouldn't be hanging from the ceiling just by the wire alone? Sarcasm
@Rad_Triumph_765_RS
@Rad_Triumph_765_RS 3 жыл бұрын
Calling BS on that Permformenbuttstang
@kalpierson9728
@kalpierson9728 3 жыл бұрын
I've been doin this for 21 years I would rather use wire nutts over wagos every time
@MrHBSoftware
@MrHBSoftware 3 жыл бұрын
you and every other trained electrician...wagos are for kids
@chrisalmere20
@chrisalmere20 3 жыл бұрын
@@MrHBSoftware kinda weird arguement, "wagos are for kids". why not make your job easyer? or maybe you respond better to this, make your job easyer, spend less time per job, do more jobs, get more money! or, make your job easyer, spend less time per job, make same amount of money with fewer hours worked, spend more time with your kids.
@MrHBSoftware
@MrHBSoftware 3 жыл бұрын
@@chrisalmere20 use cheaper wingnuts, make more reliable connections have less recalls, make more money, spend more time with your kids
@bearchow1929
@bearchow1929 3 жыл бұрын
Just watched Wago video. Just what I was afraid of. The electrical contact area is tiny compared to anything you normally get with a wire nut. That was the same problem with those 3M wire splicing pieces of junk, although they were even worse with only a knife edge for contact. Wire nuts rule!
@Adam-qu2gy
@Adam-qu2gy 3 жыл бұрын
Tiny contact area made out the highest quality copper electroplated pot metal. Great!!
@norbertfleck812
@norbertfleck812 3 жыл бұрын
The WAGO connectors are much safer than any wirenut because the contacts are spring loaded and will never get loose even with vibration. The electrical ratings are much higher than needed for the specific wire gauge.
@norbertfleck812
@norbertfleck812 3 жыл бұрын
@@joshpotter9261 You are pretty much wrong, and your "advantages" are clearly disadvantages in real life. 1. WAGO connectors can only be open or closed, nothing in between. So there's no way to install them faulty. Due to the red lever an open clamp is clearly visible. Each wire port has its own spring and lever and you only insert a single wire in each port. Also you can mix soft cables and hard wires on a single connector without cutting away the thin liz wires or risking a faulty connection. The wirenuts can be installed loose, overtightened or with only having grip on some of the wires - and you cannot spot that with visual inspection. That's why they are prohibited in EU. 2. WAGO connectors are reusable hundreds of times. You can add or remove connections whenever and as often as you want. No need to cut away anything. No need to replace anything. 3. All WAGO connectors are extremely vibration proof.
@gamestheory3244
@gamestheory3244 3 жыл бұрын
As an electrician who has done hundreds if not thousand of houses and numerous commercial and industrial projects including construction, renovations and maintenance.... the whole point of the wire nut is to replace the insulation that you strip off the conductor to keep the lines isolated after you splice them together. Whereas the wago attempts to do both the splice and insulate the connection at the same time. A lot of faith is put in that which is mass produced as cheaply as possible... It is not the job of the wire nut to maintain your splice unless you are using the crimp on style. The teeth inside the nut are designed so that it twists on to prevent it from falling off and thus maintaining the isolation of the line, identified conductor and ground. Many sites and facilities that I have been on DO NOT allow the wagos to be used because of their fail rate and lack of surface area to maintain the electrical connection. As per the client and or their electrical engineer. Of which I can attest to, many times I have gone to replace a fixture and touched them and they have fallen right off the conductor. I have also been at facilities where they use nothing but wagos just for the fact that the company thinks they are saving time and money by using wagos instead of doing a splice and using a wire nut. I’ve pulled numerous brand new wagos out to install and found them to be defective and do not latch onto the conductor. Even after installing them and doing a tug test to make sure the connection is good I still had to wrap electrical tape around the wago because the company knew that they were not perfect and failed. Yes they are quick and easy to use- ideal for the do-it-yourselfer but they do have their downsides too. A spring can fail or break. A thin piece of metal can break or become separated from where it is suppose to sit. Especially when in constant use with pressure and vibrations on it.
@NnetTucnak
@NnetTucnak 3 жыл бұрын
@@gamestheory3244 So you done it wrong and dangerous. If is wirenuts sos safe why they are banned from using in machines, cars, rocket launch pads and europe, japan and others. But wago clamps not. So USA just showing us they are dumb, like man times.
@FrancoDFernando
@FrancoDFernando 2 жыл бұрын
holy crap, thank you so much....using those twisty ones are such a pain in the ass for a DIYer, especially someone like me who tends to get anxiety working on electrical projects (not anxiety if I know how to do them, but illogical anxiety about the breaker magically turning itself back on when I'm working on an outlet lol) I immediately bought the starter pack from the link you put...thanks again!
@willmcgo8288
@willmcgo8288 Жыл бұрын
You can buy lock-out equipment for your breakers so they cannot easily be turned back on without unlocking them. Maybe you'd feel better if you took a lock-out-tag-out (LOTO) course and followed the procedures.
@FrancoDFernando
@FrancoDFernando Жыл бұрын
@@willmcgo8288 Thanks for the suggestions! I'll look into those
@arielweinberger
@arielweinberger 3 жыл бұрын
The US seems to be 20 years behind when it comes to construction materials and hardware. These are in use in every house in Western Europe and have been around for ages.
@AcousticSmokeVideos
@AcousticSmokeVideos 3 жыл бұрын
Creating a product for a problem that does not exist. Good luck fellas, I wish you all the best.
@UntiI117
@UntiI117 3 жыл бұрын
Lol for real. And I highly doubt these connectors are just as cheap and available as wire nuts
@ghosthunter152
@ghosthunter152 3 жыл бұрын
“With these, a single hand can make the connection”.... then proceeds with two hands and never shows one hand 😏
@sleeperknight
@sleeperknight 3 жыл бұрын
Exactly what I was thinking. Looks like it would actually be harder than a wire nut to do one handed.
@taleoftruth
@taleoftruth 3 жыл бұрын
They actually are easier than wire nuts but usually more expensive. Awesome for working on hot wires
@DDracee
@DDracee 3 жыл бұрын
@@sleeperknight Seemed pretty obvious to me, how are you supposed to securely twist an object onto loose wires with 1 hand? The wago you can do it wire by wire with 1 hand very easily and know it's secure. Put it on the first wire, click it, then put the other wire in it, click it, repeat for however many wires.
@KitchenerLeslie2
@KitchenerLeslie2 3 жыл бұрын
@@taleoftruth if you do wagos hot with a load you will arc burn the wago ruining its integrity.
@dranik84
@dranik84 3 жыл бұрын
Lol I was about to comment this. 🤣
@whirlwind8825
@whirlwind8825 3 жыл бұрын
There is more copper contact with wire nuts therefore less resistance under loads , and the Wago has a dissimilar metal which acts as a buss bar ...sooo "Bimetallic Corrosion" will result over time ..
@mkaz411
@mkaz411 3 жыл бұрын
Everything has it's place, and agree these WAGO's have there place but wire nuts are much better for heavily loaded circuits since they have much more surface area in contact. Iv'e replaced a few of these WAGO's on microwave and other kitchen countertop circuits that burned up.
@multitutorialguy5735
@multitutorialguy5735 3 жыл бұрын
Someone used lever-style Wagos on appliance circuits? Or were they the smaller spring-tension Wagos? Just curious. I know that the basic Wagos fail over time similar to a stabbed-in receptacle.
@norbertfleck812
@norbertfleck812 3 жыл бұрын
@@multitutorialguy5735 WAGO connectors are spring loaded and available for currents up to 1000 A. All sizes can carry much more current than the biggest wire which would fit in. They are extremely fail safe even when vibration occur. The WAGO (or rebuilts) connectors are absolutely standard in Germany for decades. Wirenuts are prohibited in Germany for safety reasons.
@proislam1447
@proislam1447 3 жыл бұрын
Bullshit
@markstedfast1288
@markstedfast1288 3 жыл бұрын
Being electrician they’re great for doing Lighting connectors but when you put real amperage to them they don’t hold up
@Dirty_Bear22
@Dirty_Bear22 3 жыл бұрын
They can take plenty of amperage, pretty sure the wire usually fails before wago connectors do.
@stifflers69mom1
@stifflers69mom1 3 жыл бұрын
Wago 222’s are the industry standard now ....hands down the better option.....every pump that gets sent out our door has wagos on them, the only time we use wire nuts is 10 gauge wire or bigger
@stifflers69mom1
@stifflers69mom1 3 жыл бұрын
Your statement is ABSOLUTELY unproven
@lisab3396
@lisab3396 3 жыл бұрын
Mark >>>> Precisely !
@slyspy9819
@slyspy9819 3 жыл бұрын
Mark are you serious ? After 40yrs. of electrical work I never had a wire nut fail ....a bad slice can make a hot spot but that's not the wire nuts fault . There's "no load' on wire nuts so they can't fail , sorry I'm not buying it
@tidBITSofINFO
@tidBITSofINFO 3 жыл бұрын
The monkey wrench on a wire nut is like those cheesy infomercials where someone uses an ax to cut bread and can’t figure out why they can’t cut bread! 😂
@DickCheneyXX
@DickCheneyXX 3 жыл бұрын
You should be able to shave with an axe.
@a111z
@a111z 3 жыл бұрын
Sounds like you need to sharpen your bread axe, or swing harder.
@burnerjack01
@burnerjack01 3 жыл бұрын
"You still can't cook on a diamond..."
@HooverVilleify
@HooverVilleify 3 жыл бұрын
Wait, there's another way to cut bread?
@michaelszczys8316
@michaelszczys8316 3 жыл бұрын
" but I have four boxes of wire nuts " throw them all away, just like throwing away your box of tools for the miracle wrench
@nikkoBcool
@nikkoBcool 2 жыл бұрын
Also I trust a properly installed wire nut any day for pulling a heavy load vs the teensy metal strip you get inside the wego,.and believe me, they do come out sometimes, I see.wegos as a definite resistance point for 12 awg when youigbt have continuous loads and wire nuts offer near zero resistance when the wires are laid beside each other tight and twisted plus you will never ever be able to pull out a wire from a proper WN install whereas with wegos I've had them pop out quite easily with their flimsy clamp system, especially as the gauge becomes smaller
@Kommunisator
@Kommunisator 2 жыл бұрын
was that with the old style Wagos? The grey ones were very specific which diameters worked with them, and which didn't. The 221 have quite a broad range in that regard, and if you can pull the wire out, then you put too much stress on a connection that should be stress-free in the first place. After all, you wouldn't pull on a cable in a wire nut. That said, I had lights complete with their casings dangle from Wagos installed at the ceiling to the fixed cables - no problem whatsoever for them (don't do that, it was a test and it worked, but DON'T leave them like that.
@nikkoBcool
@nikkoBcool 2 жыл бұрын
@@Kommunisator they were solid, new, correct size per the box, foreman demanded we all use these wegos for a big FA job, after he worked a couple days in the field, got us wirenuts instead It's just flimsy build, the tiny little strip of metal that compresses is just not enough to create a solid bond from wire to wire and we are talking almost no load for the smoke heads and strobes granted they don't fall off when you are trying to for everything in the box. You can't compare a direct wire to wire overlay with a twist bond vs a small strip that touches a bit of each copper wire. While we still had the wegos I would actually pre twist the solid wires together about 2" length, then cut them short to 3/4" and I sent into one wego hole, that was a good install at that point.
@Kommunisator
@Kommunisator 2 жыл бұрын
@@nikkoBcool if twisted wires fit into a hole together, then you might be using too thing wire or a too large Wago clamp. The standardized household wire in Germany will fit into the Wago 221 perfectly, but not if you twist two of them together - only if you strip them from their insulation beyond the edge of the clamp (which you should NOT do).
@nikkoBcool
@nikkoBcool 2 жыл бұрын
@@matthewq4b did not know that but I totally approve that.
@Kommunisator
@Kommunisator 2 жыл бұрын
@@matthewq4b That only says to me that a decade old lobby seems to have won over common sense and dozens of years of problem-free installs all over Europe. Nothing more.
@davefoc
@davefoc 3 жыл бұрын
Sorry, there might have been some value in this, but the guy is an over the top fan boy.
@kingduckford
@kingduckford 3 жыл бұрын
He's a literal paid shill. He's pushing a product for money. Completely different than a fan boi.
@davefoc
@davefoc 3 жыл бұрын
@@kingduckford Thanks, I stand corrected.
@SilverCymbal
@SilverCymbal 3 жыл бұрын
@@kingduckford Call them up, put it on their facebook. They can't legally lie, since you don't believe me. I was paid nothing, got nothing and shared an amazing product. Didn't realize it was so unbelievable that some wouldn't believe it.
@michaeljedd9359
@michaeljedd9359 3 жыл бұрын
@@SilverCymbal Politicians and cops can't "legally lie" either but we all know how that goes.
@caseyhyland3581
@caseyhyland3581 3 жыл бұрын
I stopped caring what he said after he proved he can't measure at the beginning of the video
@brandonbeal525
@brandonbeal525 3 жыл бұрын
Exactly
@MarcoPolo-jg1em
@MarcoPolo-jg1em 3 жыл бұрын
I thought the samething
@ddegn
@ddegn 3 жыл бұрын
Do you mean at 0:55 ? I'm pretty sure that was just to give a rough idea of scale. I really doubt that was supposed to show he's measuring three inches. Is he wrong about VAGO connectors?
@jazar02
@jazar02 3 жыл бұрын
That reminded me of the guy on TV jamming a Q-tip in his ear.
@RipleySawzen
@RipleySawzen 3 жыл бұрын
That looks like about 3 inches of usable wire to me. Do YOU know how to measure?
@frankdrebin1791
@frankdrebin1791 3 жыл бұрын
These will melt after years of heating and cooling. I recommend these so I have future repair work.
@timsbears
@timsbears 3 жыл бұрын
Yep just like stabbing wires in back of outlets.
@clintflippo917
@clintflippo917 3 жыл бұрын
Have you done material testing, is there a paper you read? You just guessing?
@ramoncomparan55
@ramoncomparan55 3 жыл бұрын
It all depends on the amp rating really. Put enough electricity through these and im sure they will melt.
@Username-ng8jy
@Username-ng8jy 3 жыл бұрын
They’re fine for indoor use. Outdoor. Good fucking luck lol Especially if used for lights where ballasts or heat comes into play. They become fucking brittle as hell. I’ve been shocked by 277 at work 100x with these when replacing ballasts. It’s not fun after a while.
128. Скрутка, СИЗ или ВАГО? Тепловизор решает.
20:51
ЭлектромонтажUSA
Рет қаралды 1,1 МЛН
Which Splicing Device is Best?  Push Ins Vs. Wago Vs. Wirenuts
13:06
How To Home
Рет қаралды 1,4 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
When Rosé has a fake Fun Bot music box 😁
00:23
BigSchool
Рет қаралды 6 МЛН
WIRENUTS - Why Are There So Many, and Why You Should Care...
14:31
Electrician U
Рет қаралды 143 М.
Four Steps to Flawless Wire Joints (How to Solder)
11:45
Will Donaldson
Рет қаралды 645 М.
What Wire Connector is the Best? Settling a Debate! Wire Nut VS Wago
11:09
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
The DIY Guy
Рет қаралды 3,3 МЛН
I Discovered This Hidden Wiring Trick In An Old Forum!
9:24
LRN2DIY
Рет қаралды 658 М.