Paralleling the Genmax 9K, Duromax 9K and Predator 9.5K

  Рет қаралды 10,792

Generator Superstore

Generator Superstore

Күн бұрын

Пікірлер: 101
@felaxchow207
@felaxchow207 2 жыл бұрын
A very good catch on the DuroMax parallel kit no neutral issue. From what I can tell at 1:15 it looks like it is really meant for 250 volt use only and there shouldn't be a neutral pin on the 30 or 50 amp connection. Standard nomenclature if it was to be utilized in split phase mode it should be 125/250. My experience working in the electrical field when your 125/250 volt 50 amp plug tester is showing open neutral is bad news from the get go and you will end up frying up some 120 volt appliances. You can bond the neutral and ground at the parallel box, but the ground is only meant to carry fault current back to the generator to trip the upstream breaker to clear the fault and not the unbalanced load between the phases. Also, it will cause a potential shock hazard since no one would expect any current flowing through the ground connection. I think DuroMax dropped ball on this one for not having a dedicated neutral for 125/250 volt split phase operation. Great work and it might've save someone's RV from a potential electrical nightmare using the parallel kit. I've went through a few old school hard knocks and learned to test and verify before plugging in. Having a Power Watchdog inline to serve as extra insurance against those costly oopsies. After all we are human and we're not infallible. :-P
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Thanks for sharing this Felax Chow very insightful and informative feedback. Most people don’t understand why I always have the surge protector on all my test. I’ve seen poor connection, reverse connection, open grounds, open neutral, you can’t just trust the manufacturers to deliver a fault free product. Thanks for watching I hope I earned your subscribe 👍🏾
@felaxchow207
@felaxchow207 2 жыл бұрын
@@GeneratorReviews oh yes, I've hit that subscribe button quite awhile ago. Learned a lot and getting good ideas on projects along what pitfalls you might run against. I am in the process of designing my electrical system for my class B upfit. What I have on paper is 1 kW solar and 15 kWh lithium storage at nominal 52 VDC. The further into the rabbit hole I get into, I am starting to go with Victron Energy gear and I might get their isolation transformer to electrically separate the shore power connection as extra insurance.
@wow1022
@wow1022 2 жыл бұрын
i think you could pluck a neutral off the 30A twist socket and run a neutral wire from each generator and parallel the neutrals into the 50A plug on the kit... not that hard of a modification and annoying you have to do that... but it's possible
@yvonnecates511
@yvonnecates511 2 жыл бұрын
@Gavin's Garage. You are a wealth of knowledge. Thank you sir!
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Thanks 😊
@CubNole
@CubNole Жыл бұрын
You are the Generator King, thanks for the videos!
@GeneratorReviews
@GeneratorReviews Жыл бұрын
Thanks 🙏🏾
@wingloading
@wingloading 2 жыл бұрын
I'm a Duromax parallel kit user -- single generator but I added the kit as insurance against a 30amp breaker tripping while feeding my home. Most of my load side neutral current seems to return on the utility neutral, so I weighed disconnecting the kit's ground terminal. When I disconnected the ground, I have a couple of computer UPS units which did not react well by constantly cycling back and forth on battery. The batteries probably pick up something not right with the effective ground, so that leaves me with depending on the generator's bonded neutral to keep working. For standalone or separately derived, this is not an ideal solution. Also I believe if the neutral and ground were bonded on the load side, that #8 ground wire might be a bit under spec.
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Hey Jim There is a fix you can add a neutral wire to your parallel kit and you should be using number 6 wire. If you’re powering an RV or a transfer switch you want to be bonded, if you’re using an interlock kit you do not want to be bonded but you have to add a ground. That’s probably why your UPS are acting funny. Thanks for watching
@PRIME_ATE
@PRIME_ATE 3 ай бұрын
Can this kit be used for the 9500 inverted Duramax generator??
@GeneratorReviews
@GeneratorReviews 2 ай бұрын
No, I don’t believe it will
@eugeneclark8463
@eugeneclark8463 Ай бұрын
Thanks for the demo, thinking about future parallel setup, my question is this: Genmax you are showing, 9000/7500 running, paired should make maximum 15000 running watts, when paired you are using 1- 50 amp wire connection to panel from 1 generator ( this is rated for up to 50 amps ) but combined amperage produced is approx over 66.5 amps. To get full power benefit, would you run 50 amp wire off second generator to second connection to panel ( another plug and another 50 amp breaker) to utilize all 60 amp plus power at maximum running watts. Thanks for any information on this, I know a little about power but nothing about portable generators, again thank you for what you do and sharing
@GeneratorReviews
@GeneratorReviews Ай бұрын
If you plan on pulling the maximum power of 12,500W from your 50 amp in my box, yes you will need too.
@Tom-In-Ga
@Tom-In-Ga 2 жыл бұрын
Can't help but wonder why Duramax didn't provide the neutral connection. Could you use a bonding plug on the Duramax?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Since there’s no actual cable going to the parallel kit The bonding club would be useless
@Tom-In-Ga
@Tom-In-Ga 2 жыл бұрын
@@GeneratorReviews Yeah, I guess you're right. I was thinking if you plugged a bonding plug in L1 and L2 of the 120v outlets, it might work. But there's no wire to the kit so how could it? See, that's why you have a great YT channel and I just watch.😉
@VidJunkie63
@VidJunkie63 2 жыл бұрын
In your (or the readers here) opinion, is it better to go with two smaller capacity portable generators in parallel, or one large capacity portable generator to perform a whole house back up power solution?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
One larger you’ll thank me later
@egravelfl
@egravelfl 2 жыл бұрын
Thanks for your video! I bought a DuroMax XP12000EH about 2 years ago and got to put it through its paces last Oct after hurricane Ian. It worked great though I suspect that I lost a few electronic equipment either because it caused a power surge or FPL did when they restored power to my home. I wish I had known about potential power surge issues with generators way back when I bought this. From one of your other videos, I saw that I should replace my generator with an inverter generator to condition the power's sine wave (prevent surges). I've been considering the DuroMax XP9000iH but after watching your (this) video regarding the parallel kit; I'm not sure. You showed that the DuroMax parallel kit does not have a neutral wire. And you stated at around 3:19 that if you use a surge protector in your home that it won't work. What won't work? What's the impact of running this generator if there's no neutral. I'll admit that I don't fully understand that statement. Dammit Jim, I'm a Software Architect, not an electrician! :) Could you expand on this for me please?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
The surge protector needs to see a bonded neutral to ground in order to work properly
@egravelfl
@egravelfl 2 жыл бұрын
@@GeneratorReviews So this generator, or at least when used with the parallel kit, is not meant to be used in back feeding a whole house. Is there a way to make it compatible? If not, what inverter generator can be use for such application that provides at least 9000 Watts? Thanks.
@bandit5936
@bandit5936 2 жыл бұрын
Is it true that the Duramax has a CO2 shut off so if I have it my barn it won't keep shutting off do you know about that thanks
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
It has a CO monitor shut off if you put it in the barn it will shut off the generator
@MrCam3565
@MrCam3565 2 жыл бұрын
is it possible to make your own parallel plug for the predator or duromax like meeting the two 240v plugs together and still get the 50 amps? and if its possible would you make one and show how you did it and do a second part to this video?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Yes that is a possibility and yes I can show how to make it great idea by the way💡👍🏾
@mikek8229
@mikek8229 2 жыл бұрын
I'd really like to see a video in on that too
@tomroth2634
@tomroth2634 2 жыл бұрын
I would love to see that!
@Rk-mt4ll
@Rk-mt4ll 2 жыл бұрын
Yes, Mine is working great. Check out the diagram on post 123 www.powerequipmentforum.com/threads/duromax-xp9000ih-pk-parallel-box-question.25478/page-7#post-96403
@Caguzzi
@Caguzzi Жыл бұрын
Which unit do you prefer out of the three? Genmax, Duromax or Predator. Trying to decide between one of these or the Duromax 1300. Thanks!
@GeneratorReviews
@GeneratorReviews Жыл бұрын
I prefer the GenMax dual fuel, 50 amp plug and it’s the only one with oil filter screening plus so many more features
@michaelslack6891
@michaelslack6891 Жыл бұрын
Hey Gavin! Thank you again for the great information! I have a question maybe you can help me with. I have 2 Duromax xp9000ih's and the Duromax 240 volt parallel kit that I will be using for emergency power to my main panel via 50 amp inlet box and interlock kit on the main panel. I have not tried them yet as I am still breaking them in. Do you think I will have a problem tripping my 3 GFCI circuits in the main panel because of the lack of seperate neutral wires on the generators and parallel kit? Thanks for your time and knowledge, Mike
@GeneratorReviews
@GeneratorReviews Жыл бұрын
I haven’t tried it yet but I think you should definitely try your setup before needing it in a real power outage. Let me know the results
@barryhagan9742
@barryhagan9742 5 ай бұрын
It will work as long as you maintain the neutral bond on the generators. No respectable electrician will say this is is a good setup, but it will work. Since there is no neutral connection between the generators and the kit, your neutral is created using the ground wiring between your panel and the generators. This is completely against electric code, but it works. And it works because there are two neutral bonds. 1 in your panel and again at the generators. So what happens here? The missing neutral is effectively jumperer to the ground wiring. Unbalanced current between your 120V circuit legs in the house is going to flow on the ground wiring between your panel and the generators.
@michaelslack6891
@michaelslack6891 5 ай бұрын
I ended up unbonding the generators easily and added neutral wires to the parallel kit which I plug into the 30a on the front panel. All surge protectors, afci and gfci breakers and plugs in the house run perfectly. Thanks for the videos! Mike in DFW
@menolose123
@menolose123 Жыл бұрын
If you had to pick one , which one would you pick ?
@GeneratorReviews
@GeneratorReviews Жыл бұрын
My first choice I think because of the 50a plug and the fact that I don’t have to have a parallel kit would be the Genmax second choice would be Duromax. They both have displays, dual fuel and remote start.
@jmyers4006
@jmyers4006 3 ай бұрын
Thanks for all your videos. They have been super helpful. New subscriber. Is there any advantage to getting 2 4500 watt generators as opposed to one 9000. If one goes you’d still have half the power?
@GeneratorReviews
@GeneratorReviews 3 ай бұрын
Thanks 😊
@bdkbdk8005
@bdkbdk8005 5 ай бұрын
So does paralleling the generators give you double the power?
@GeneratorReviews
@GeneratorReviews 5 ай бұрын
Yes that is correct
@garden-queen2393
@garden-queen2393 2 жыл бұрын
Great parallel video. Thanks 👍
@melvinhanson3659
@melvinhanson3659 2 жыл бұрын
When you use these generators on your home is there a transfer switch that negates the bonded neutral or will I need to umbind it at the generator? If that’s the case then you want to use it for your rv do you have to rebond it?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
The transfer switch and the Rv both require a bonded generator but the inlet box is the only one that has to be a floating neutral generator. I hope this helps Thanks for watching and subscribing 👊🏾💯
@alanmarbaker7478
@alanmarbaker7478 2 жыл бұрын
Is the genmax 50 amp plug on a 50 amp breaker so you can take advantage of all the amps available when connected in parallel? Or is it a 35 amp breaker so it only gets the max of 1 generator?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
It’s a 50 amp breaker.
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
That’s why when I use it solo by itself I usually use a 30 amp four pin 30a x 240v= 7200
@electriccuts
@electriccuts 2 жыл бұрын
How do you get all your generators? Do they send them to you?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
I get sponsored by Genmax and the predator and Duramax already sold.
@electriccuts
@electriccuts 2 жыл бұрын
@@GeneratorReviews you sell the generators??
@electriccuts
@electriccuts 2 жыл бұрын
@@GeneratorReviews what website?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
@@electriccuts i’m still working on my website the ones I sold are the ones I buy and then I sell them. If you see one I review and you wanna buy it just email me
@electriccuts
@electriccuts 2 жыл бұрын
@@GeneratorReviews what is your email address?
@banhvo4958
@banhvo4958 10 ай бұрын
Hi Galvin, i had predator 9500 and genmax 9000iedc,both set on floating neutral for home backup through 50amp inlet, do i need to use bonding plug to make it bond neutral before parallel these 2 generator generators ? Or just leave it floating neutral?
@GeneratorReviews
@GeneratorReviews 10 ай бұрын
The only time we have to worry about bonded is when you’re trying to use a surge protector or charge an EV car
@banhvo4958
@banhvo4958 10 ай бұрын
Thank you, i have to connect neutral on both generator although it's floating ?
@ryanyoshimura
@ryanyoshimura 2 жыл бұрын
So if I use this parallel kit that has no neutral and plug to my house inlet, do I still need remove the bonded neutral in the generator?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Great question You shouldn’t have to since the neutral is not bonded but you still running all that power on one ground
@barryhagan9742
@barryhagan9742 5 ай бұрын
Do not remove the bonded neutral when using Duromax kit. That is the only way the unbalanced current from your 120V home circuits is returning to the source. If you float the neutrals, there is no path for that unbalanced current, so it will flow on the hot 120V legs and cause over/under voltage on your home circuits. The severity of that over/under voltage depends on how unbalanced the loads are. Every time you turn something on or off in the 120V home circuits you will be changing that imbalance. These kits should not be sold without neutral wiring. It is irresponsible how they were allowed to sell them.
@GalloPazzesco
@GalloPazzesco 4 ай бұрын
Gavin, you are DA MAN!
@GeneratorReviews
@GeneratorReviews 4 ай бұрын
Thanks man!
@GalloPazzesco
@GalloPazzesco 4 ай бұрын
@@GeneratorReviews i'm pretty sure they still have a 50 Amp parallel kit in some of the HF stores. I'll try to get a part number for you Gavin. SKU 58374 and ouch I just now realized that I've been exceeding the recommended limits (2x5500 watts) for that kit .... ruh roh. Now I have to regroup.
@shanwar9844
@shanwar9844 2 жыл бұрын
The second genmax sounds like the starter solenoid doesn't release the starter properly. It's hung up on the flywheel for a bit. What's your take on that?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
After watching it again sounds like I should’ve turned the choke a little sooner but since I had the camera in one hand
@campbellsoup4910
@campbellsoup4910 2 жыл бұрын
Hey G' Very informative vid👍🏾
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Thanks 🙏🏾
@vipseat
@vipseat 2 жыл бұрын
Between the Genmax 9000 and Duromax XP12000EH, which would you recommend for a 2000 square foot home?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
The Genmax 9000 is an inverter generator and would provide pure sine wave power to your home and would be quieter.
@davidsimon6011
@davidsimon6011 2 жыл бұрын
Hi Gavin....:) Questions....? I have a Westinghouse 4500 dual fuel inverter generator for running my 30amp Rv, I also have a 50amp surge protector with a pigtail because I'm running power from a 50amp pedestal circuit. I have a soft start for my A/C as well. Does this generator have a neutral so I can use my 50 amp surge protector inline with my generator? I haven't tried running it yet with my RV. Hope this makes sense I'm a little nieve to some of this....;) Thanks
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
You just need a bonding plug for your generator and you can and should always use a surge protector amzn.to/3xtXjwv
@wow1022
@wow1022 2 жыл бұрын
this is dangerous AND BE CAREFUL ABOUT ANY MODIFICATIONS, current is NOT supposed to flow through the ground during normal operation... DO NOT plug the parallel kit into your home without paralleling the neutral from each generator into the neutral of the 50A socket on the parallel kit.... use #8 stranded wire MINIMUM for your neutral as each generator puts out 30A and #8 is good for 40A continuous, you can get a neutral off the 30A twist socket by wiring a custom plug
@aronlichtman
@aronlichtman Жыл бұрын
If i connect 2 genmax 9000 can i get 62amps?
@GeneratorReviews
@GeneratorReviews Жыл бұрын
You will get 12500 watts at 52 amps 240v
@aronlichtman
@aronlichtman Жыл бұрын
@@GeneratorReviews but the 50amp breaker will trip by 50amp how can I get the full power?
@MikeMike-is2hl
@MikeMike-is2hl 2 жыл бұрын
Is there a parallel kit with 120/240 ? I would like to pair 2 inverters to power my house... looking for a pair that will give me at least 12K watts. Is there any combo that will give me that ?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
They do have a few but brand specific the Honda and Duromax both has a 120/240 kit I haven’t found a universal One yet
@redfule
@redfule 2 жыл бұрын
Very good 👍 what are the prices of the Duramax and the Genmax
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Check out the links in the description I have all the prices and the links to them
@davestaco
@davestaco 2 жыл бұрын
Can you parallel the genmax and the predator?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Yes I can
@BradiKal61
@BradiKal61 2 жыл бұрын
If your home needs two 9,000 watt generators in parallel to keep you going during a power outage then why don't you just get a dedicated home backup generator that runs off of natural gas? Am I crazy?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
99% of people who need this owns trailer business like food trucks and this Barry gets them by
@cleverman86
@cleverman86 2 жыл бұрын
I went with the two 9kw portable generator due to the high cost of dedicated home backup plus install and permits. I also get the flexibility of taking it with me when traveling.
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
@@cleverman86 👌🏾💯yep best route
@motoboss5250069qew
@motoboss5250069qew 2 жыл бұрын
@@GeneratorReviews so if I'm running 2 Duromax 9000 generators on parallel for home backup I can't use surge protection? Is it safe?
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
@@motoboss5250069qew perfectly fine
@defjamsgreen
@defjamsgreen 2 жыл бұрын
Great generator split phase connecting video .Keep us preppers informed of how they are wired in parallel to get the most power out of them . 😉🤙
@satgod
@satgod 9 ай бұрын
over a year and still no predator 240v parallel kit
@michaelslack6891
@michaelslack6891 5 ай бұрын
Get the Duromax parallel kit and add 2 neutral wires easily.
@colencasey7761
@colencasey7761 5 ай бұрын
@@michaelslack6891 made my own, was just saying they need to make one also the ground and neutral are tied together on the predators so one or the other gets you the same unless you unbond the neutral from the ground on them
@code3k5
@code3k5 2 жыл бұрын
now i want 2 genmax ;)
@RShivesy
@RShivesy 2 жыл бұрын
You gotta charge money for watching these videos as we all are learning so much.😁 Where is the link to that Progressive Industries 50amp lighted plug? Nice asset to have.Thanks Gavin
@GeneratorReviews
@GeneratorReviews 2 жыл бұрын
Thanks 😊 Find that thanks button and sponsor a video 👍🏾
@BradiKal61
@BradiKal61 2 жыл бұрын
Bye bye Duromax!
@FatMat916
@FatMat916 5 ай бұрын
How long to charge an ev???
@GeneratorReviews
@GeneratorReviews 5 ай бұрын
It really depends on the amperage you’re using and the EV itself
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 958 М.
GENMAX GM9000ieD Paralleled with DUROMAX XP9000iH
8:16
Generator Superstore
Рет қаралды 4,7 М.
Duromax 16000iH Inverter Generator! Why Buy This Over Any Other?
8:17
Renovations and Repair
Рет қаралды 64 М.
Cheap vs. Expensive Generator (Surprising Results)
25:49
Ambition Strikes
Рет қаралды 929 М.
GENMAX GM9000ieD Paralleled with PREDATOR 9500