Pellet Tech 101 - Making a Motor/Blower Test Cord

  Рет қаралды 13,123

Earth Sense

Earth Sense

Күн бұрын

This video will show you how to make a test cord. Making a test cord can be very handy to test motors and blowers outside of the stove to verify their operation function.

Пікірлер: 28
@kkeduda
@kkeduda 8 ай бұрын
Thank you! My convection blower wasn't working and I was all set to pay $150 for a new one. I built a test cord and checked it, and it was fine. I used your other video to make a bypass cord and check the low limit switch, and that was the problem. A new one is on the way and I am cautiously optimistic that it will fix the problem. Thanks again!
@EarthSense
@EarthSense 8 ай бұрын
Fantastic to hear - great job on your troubleshooting! Let us know how everything is working once you have the new switch installed. Thanks!
@kkeduda
@kkeduda 8 ай бұрын
No good!?! The convection blower worked with the bypass cord. However, when I installed a new switch the blower would not turn on at all. I waited quite a while until the switch got over 150 degrees as measured with an IR thermometer. Now I don't know what to do?
@kkeduda
@kkeduda 8 ай бұрын
I also checked the old, presumed bad switch by connecting it to an ohmmeter. It initially read "-1" or no reading. When I heated it with a heat gun, it almost right away went up to 2.5 and stayed there with only a tiny click. After cooling, it was back to "-1". Maybe the swtich wasn't bad? How could the jumper cable make the convection fan work if the switch wasn't the problem?
@kkeduda
@kkeduda 8 ай бұрын
Since I just figured it out, I'm replying to my own comment in case anyone in the same boat needs some guidance. My problem was NOT the convection motor, or the limit switch. I needed a better cleaning!!! I usually clean out the ports, but not the tunnels between them. The limit switch sits on one of these tunnels and all the buildup prevented heat from getting to the switch to trigger it. When I cleaned it out, the switch triggered in about 5 minutes. Now I have a new switch that I didn't need, but I figured it out.
@EarthSense
@EarthSense 8 ай бұрын
@@kkeduda Thanks so much for your messages; apologies on the delay. Excellent troubleshooting work cleaning out those tunnel areas. I'm sure you also notice better overall air flow now as well. You should be able to return that switch unless you want to keep as a spare. Really appreciate you sharing this with us and the community - I'd bet it will most certainly help others. Greatly appreciated!
@vickilewerenz7061
@vickilewerenz7061 6 ай бұрын
Thank you
@EarthSense
@EarthSense 6 ай бұрын
You're most welcome! If you need anything else just let us know. Thanks!
@jasonosburn5984
@jasonosburn5984 3 жыл бұрын
My englander started giving me issues two months ago ... i had to replace the exhaust fan and then the lower auger motor blew. your videos helped me SO much. Thank you.
@EarthSense
@EarthSense 3 жыл бұрын
So glad to hear they were helpful Jason! Any questions down the road just let us know, always happy to help. Here is our Englander parts page in case you ever need reference down the line. pellethead.com/?s=englander Appreciated!
@millerkold
@millerkold 4 жыл бұрын
Thanks man, although your fly is unzipped, and yes I was looking
@johnjohnson2826
@johnjohnson2826 Жыл бұрын
Ha ha ha ha ha now thats funny.
@jessicaselg1836
@jessicaselg1836 4 жыл бұрын
Which wire do you put the female on and which do you put the male on?
@EarthSense
@EarthSense 3 жыл бұрын
Apologies on the delay Jessica. Just depends what the lead wire spade connections are from the motor. Some are male, some are female, some are 1 of each. Doesn't matter which wire lead goes to which on the motor, just want to match up those spade connectors to what the motor has. Hopefully that helps, any other questions please let us know. Thanks!
@deepcjseven
@deepcjseven 4 жыл бұрын
I have a Harman Accentra, how much should the intake flapper open when combustion fan is running? I have a flame that is tall and lazy and suspect the combustion fan motor.
@EarthSense
@EarthSense 4 жыл бұрын
Hey William, thanks for contacting us. Definitely sounds like there is a fuel to air ratio issue going on with your Accentra. The intake flapper does not open fully in operation - I would say it's generally 1/4 to 1/2 open during operation. If you have fresh air intake flex on the stove, that flapper should be completely removed. You can check the voltage on your combustion fan - should be near line voltage during start-up. Ash build-up and blockage would be the number 1 cause for the fire you are seeing. Make sure you've checked the following. - Burnpot Holes - Inspect closely and make sure they are all open - Burnpot Cleanout - Front cover access port - Fully cleaned out. - Door gasket - Sealing tight all the way around. - Remove the plate behind the ash pan and check the combustion fan paddle and exhaust throat for any obstructions. - Exhaust venting checked and cleaned - Rear Heat Exchangers checked and cleaned. Keep us posted, happy to help. We offer every part for the Accentra and guarantee the best prices. Thanks again, Mr. Pellethead
@deepcjseven
@deepcjseven 4 жыл бұрын
Thank you Earth Sense for replying. I thoroughly cleaned out the entire stove especially the areas you suggested. My flapper is opening a 1/4 to 1/2" max and the flame does not change when I open it fully. I will measure voltage next. Mean time applying penetrating fluid to fan lock screw, maybe it'll come off without having to cut the driveshaft.
@deepcjseven
@deepcjseven 4 жыл бұрын
@@EarthSense why 2 different motors with different amp ratings? Mine is 1.75 amp others have .9 amps.
@EarthSense
@EarthSense 4 жыл бұрын
@@deepcjseven OK, yes the combustion air issue is elsewhere. Let us know when you get a voltage reading. Yes, WD40 or PBblaster is great to soak into that lock screw. Heat can also be really beneficial in getting that to move - if you have a pencil torch, heat it up a bit. Again, double check ash blockages in the areas I originally mentioned as well. Keep us posted!
@EarthSense
@EarthSense 4 жыл бұрын
@@deepcjseven Hey William, Amperage of motors will vary based on the brand and type. We often see those same ranges from .9 - 1.75 amp. For the most part we have not encountered issues with variances in motor amperage's. Often times the replacement motor is a different amperage than the original. As long as the RPM and voltage is the same, there shouldn't be an issue.
Harman Stove Auger Feed Shaft Replacement
9:37
Earth Sense
Рет қаралды 20 М.
🩷🩵VS👿
00:38
ISSEI / いっせい
Рет қаралды 16 МЛН
Kind Waiter's Gesture to Homeless Boy #shorts
00:32
I migliori trucchetti di Fabiosa
Рет қаралды 10 МЛН
Fortunately, Ultraman protects me  #shorts #ultraman #ultramantiga #liveaction
00:10
7 Days Stranded In A Cave
17:59
MrBeast
Рет қаралды 74 МЛН
Troubleshooting: Pellet Stove Auger Motor Hums but Won't Turn
5:21
Midwest Hearth
Рет қаралды 32 М.
How To Remove a Rusted Blower Wheel Tech Tips
9:10
Anti DIY HVAC
Рет қаралды 58 М.
How to Replace Harman Auger Motor, Direct Drive
8:22
Earth Sense
Рет қаралды 14 М.
Troubleshooting a Defective Blower / Fan Kit
9:46
fireplaceblowers
Рет қаралды 48 М.
How To Find Sparking/Short Circuit Ryobi Router Commutator
18:13
DIY Alam
Рет қаралды 2,3 МЛН
Understanding the Englander Pellet Stove Control
8:19
ReiMonCoH
Рет қаралды 90 М.
When A Gang Leader Confronted Muhammad Ali
11:43
Boxing After Dark
Рет қаралды 7 МЛН
🩷🩵VS👿
00:38
ISSEI / いっせい
Рет қаралды 16 МЛН