Commercial Rooftop HVAC Unit Not Cooling

  Рет қаралды 6,750

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Mikey Pipes - Pipe Doctor Plumbing & Heating & Air

Күн бұрын

Пікірлер: 88
@ld45678
@ld45678 5 ай бұрын
He is an honest tradesman. Would anyone else be this transparent?
@PipeDoctor
@PipeDoctor 5 ай бұрын
Absolutely! Transparency is key in building trust.
@robd7365
@robd7365 5 ай бұрын
What pressure / temp were you looking for on the low side when adding?
@realestateservicessaleshea99
@realestateservicessaleshea99 3 ай бұрын
Stay safe and wear your safety glasses!!!
@scottvolage1752
@scottvolage1752 5 ай бұрын
#2 Make the trades great again Mikey Pipes. Smash that Like Button folks.
@PipeDoctor
@PipeDoctor 5 ай бұрын
love you. no homo
@robertsmith2956
@robertsmith2956 5 ай бұрын
Mikey Pipes couldn't find the unit with the leak till lunch. LOL When you said you love rooftop units. I thought NOPE, which one..... Looks like fiberglass ladder, so your good. Unless you are doing the left hand behind back climbing down.
@Myoldiesrecordings
@Myoldiesrecordings 5 ай бұрын
Great vid love seeing you guys around town Its worth it to the customer to do a service call and refill tanks over finding the leak? ? Also its not even hot out yet round here what if the leaks getting bigger and this time youll be out there again in a few weeks?
@PipeDoctor
@PipeDoctor 5 ай бұрын
Will probably be back next year
@shanestegg7661
@shanestegg7661 5 ай бұрын
When I get a new unit yall trying to get under 500 microns or nah?
@PipeDoctor
@PipeDoctor 5 ай бұрын
My goal is under 100 µm
@JesseDoesHVAC
@JesseDoesHVAC 5 ай бұрын
Reading thru the comments i notice everyone keeps forgetting a big part of this trade. The customer ls wallet dictates how far they’re willing to go. Slam the Pipe Doc all you want for the gas n go, but maybe they dont wanna spend the thousands of dollars to replace the coil!
@PipeDoctor
@PipeDoctor 5 ай бұрын
Exactly. People love to just comment without actually thinking
@Brad1237202
@Brad1237202 5 ай бұрын
Thanks for the video Mikey!!! Getting an education from every video! Keep up the great work!
@PipeDoctor
@PipeDoctor 5 ай бұрын
Thanks for watching!
@nickc6399
@nickc6399 5 ай бұрын
Top of the coil is naturally going to be hotter it’s getting sub cooled as it hits the bottom of the coil. That’s normal to feel that temp change about 3/4 of the way down.
@PipeDoctor
@PipeDoctor 5 ай бұрын
Thanks for the wisdom
@SusanMackey-p5e
@SusanMackey-p5e 5 ай бұрын
It still has gas top it off and move on as you did, time is money!! Good job!
@PipeDoctor
@PipeDoctor 5 ай бұрын
Thanks!!
@zacharypalczynski8450
@zacharypalczynski8450 4 ай бұрын
Don’t ya jumper Y/R/G as a cooling call? Or u letting the board run the fan? Hmmmmmmm
@jeffsidoti9109
@jeffsidoti9109 5 ай бұрын
If you had to add refrigerant doesnt that mean there was a leak?
@PipeDoctor
@PipeDoctor 5 ай бұрын
Winner winner, chicken dinner
@tjlovesrachel
@tjlovesrachel 5 ай бұрын
May 8th …my sons birthday ❤
@PipeDoctor
@PipeDoctor 5 ай бұрын
Happy belated birthday
@tjlovesrachel
@tjlovesrachel 5 ай бұрын
@@PipeDoctor thank you Mikey pipes
@Eddy63
@Eddy63 5 ай бұрын
Another great production ... Appreciate all your effort ... Thx
@PipeDoctor
@PipeDoctor 5 ай бұрын
Thanks buddy
@utubepro7742
@utubepro7742 5 ай бұрын
MICRO CHANNEL ALUMINUM SOLDER REPAIR VERY DIFFICULT! But possible
@PipeDoctor
@PipeDoctor 5 ай бұрын
Yeah, time to replace the entire coil
@nonamesplease8228
@nonamesplease8228 5 ай бұрын
You'll be back on this one in a few weeks with all that oil on the condenser coil
@PipeDoctor
@PipeDoctor 5 ай бұрын
We gave a quote to replace the coil last year. Duhhhh
@elone1748
@elone1748 5 ай бұрын
It helps the algorithm
@PipeDoctor
@PipeDoctor 5 ай бұрын
it sure does
@kevinfountain3980
@kevinfountain3980 5 ай бұрын
Careful on that ladder
@guygfm4243
@guygfm4243 5 ай бұрын
Love the waygo
@PipeDoctor
@PipeDoctor 5 ай бұрын
Absolutely love Waco
@scottmaz4063
@scottmaz4063 5 ай бұрын
Nice clean video mikey
@PipeDoctor
@PipeDoctor 5 ай бұрын
Thanks Scott
@scottmaz4063
@scottmaz4063 5 ай бұрын
#1🎉🎉🎉
@PipeDoctor
@PipeDoctor 5 ай бұрын
Congratulations 🎈🎊🍾🎉
@scottvolage1752
@scottvolage1752 5 ай бұрын
Hay Scott M. How's it going up there?
@scottmaz4063
@scottmaz4063 5 ай бұрын
@@scottvolage1752 cold and raining coming back end of June. We miss it in Florida.
@manonfire3642
@manonfire3642 5 ай бұрын
Mikey Pipes...you must cross the line and fight the internal war within your own country (in order to save the HVAC's potential).
@PipeDoctor
@PipeDoctor 5 ай бұрын
OUCH! I'm a lover not a fighter! Love you, no homo
@nickyfresh6577
@nickyfresh6577 5 ай бұрын
Mikey on a micro channel coil fuck that I will never do that shit again finding a leak way to much time. Gas and Go, let the customer know they have a leak , see how long the recharge last maybe next time shoot some stop leak in it .... but id change the coil out not a fan of stop leak .... Nickyfresh out !!! See you around long island brother I miss the shop over by HD :(
@throttlebottle5906
@throttlebottle5906 5 ай бұрын
*cough cough cough* "got some freon in my throat", I didn't know you use "inhalers" 🤣🤣 but seriously, most of them use R-134A as the propellant, breathe deep!
@PipeDoctor
@PipeDoctor 5 ай бұрын
🤭
@bakerslounge
@bakerslounge 5 ай бұрын
Customer replacing the condenser coil?
@PipeDoctor
@PipeDoctor 5 ай бұрын
We quoted last year. It’s still there
@shailzdumont5219
@shailzdumont5219 5 ай бұрын
More rooftop vids
@tuffram2165
@tuffram2165 5 ай бұрын
Honestly, it is a very noticeable video quality difference. Especially on my 75" Samsung Q LED TV.
@PipeDoctor
@PipeDoctor 5 ай бұрын
Incredible
@HVACingMyWay
@HVACingMyWay 5 ай бұрын
If I’ve never been to system before I gas and go see how long it last then from there I decide what to do ultimately up to customer though
@hvacrnortheastern2110
@hvacrnortheastern2110 5 ай бұрын
Mike try serving a RTU on a mall they aren’t ever labeled or number.😮
@PipeDoctor
@PipeDoctor 5 ай бұрын
been there, done that
@mikepekarek6220
@mikepekarek6220 5 ай бұрын
That leak is in the bottom corner of the coil. How can you miss that big oil spot. Those coils are junk.
@PipeDoctor
@PipeDoctor 5 ай бұрын
Complete garbage
@DevinHVACInc
@DevinHVACInc 5 ай бұрын
Love gas and go 💴
@PipeDoctor
@PipeDoctor 5 ай бұрын
don't we all?
@DevinHVACInc
@DevinHVACInc 5 ай бұрын
@@PipeDoctor absolutely.
@Android_Warrior
@Android_Warrior 5 ай бұрын
So you bought the business from the old man in Florida?
@PipeDoctor
@PipeDoctor 5 ай бұрын
More like a merger
@Android_Warrior
@Android_Warrior 5 ай бұрын
@@PipeDoctor : But with a name change!!!💪💪💪
@steveblake8766
@steveblake8766 5 ай бұрын
170 thumbs up
@kat2641
@kat2641 5 ай бұрын
Nope I am “ Not “ going to lecture you on them worthless piece of junk, micro channel pieces of crap..(( 😂 can you tell I don’t like them?😂)) but after many many years of serving the gages tell us approximately how low unit is without evacuating and seeing what’s left, it just comes with the art of years of service… but so as not to let you feel un loved …….. Mikey Pipes!! A.. that little giant ladder is not tall enough! An B? I didn’t see a safety rope 😜 rolling on the floor laughing sorry boss man got to give you a little grief ❤ But being honest here most commercials? Just gas and go they do not wanna pay to find the problem. They take the easy route and the cheapest route, but as we both know, sometimes the cheapest route in the end was the most sus expensive.🤷🏻‍♂️ But I totally agree with you. I love rooftop units other than the communication wire and the T stat? Everything is up there well most everything.. your lead seal fire trap doors are usually down below… yea a question 🙋‍♂️ does NY require fire dampers in the duct work? Michigan is a pain about it 🤷🏻‍♂️ but beautiful day to be on the rooftop
@PipeDoctor
@PipeDoctor 5 ай бұрын
We don’t need no stinking fire dampers!
@kens.3729
@kens.3729 5 ай бұрын
Restaurants are the Very Worst for doing Any Preventative Maintenance on their Rooftop Equipment. They Don’t Care if Cost them more money in long run. 🤪👎
@PipeDoctor
@PipeDoctor 5 ай бұрын
I know. But I still love working on RTUs
@victormayoral7809
@victormayoral7809 5 ай бұрын
This is hilarious. You shouldn't have pardoned these idiots.
@PipeDoctor
@PipeDoctor 5 ай бұрын
Yeah, you know what I figured. We all deserve a second chance.
@robertcooke3500
@robertcooke3500 5 ай бұрын
Block the trolls
@PipeDoctor
@PipeDoctor 5 ай бұрын
Unblocked them
@danjoyce6135
@danjoyce6135 5 ай бұрын
Not even attempt to find the leak. Gas and go... collect the check and go. Total disservice to the customer
@PipeDoctor
@PipeDoctor 5 ай бұрын
Hahaha! Another rocket 🚀 scientist 👩‍🔬 who thinks they know everything! Guess you missed the part that we quoted a new coil last year. Pipe Doctor & Mikey Pipes = BOSS Cha Ching b!tch
@robertdavenport9095
@robertdavenport9095 5 ай бұрын
@@PipeDoctor Epic response bro. Keep up the great work!!!!
@PreyTheSun
@PreyTheSun 5 ай бұрын
​@@PipeDoctorI heard you're a real loser pretending to have any real certification or license, when you a actually have none.
@PreyTheSun
@PreyTheSun 5 ай бұрын
​I heard you got all butthurt when the guys at Navien wouldn't work with you because you're a bum and you only do it for the clicks, likes and your lame ass KZbin channel. Keep smoking, you sound great! ​@@PipeDoctor
@Guyhakverdi
@Guyhakverdi 5 ай бұрын
😂
@markandsuriyonphanasonkath8768
@markandsuriyonphanasonkath8768 5 ай бұрын
Micro channel is HORRIBLE, all 15 of our Samsung micro channel A/C's failed within 5 years, very poor quality. Back to "tube and fin". all great!
@PipeDoctor
@PipeDoctor 5 ай бұрын
Microchannel coils absolutely suck ass
@BlahBlah-em2ed
@BlahBlah-em2ed 5 ай бұрын
If you see Trump while out and about, tell ‘em I said hi!
@PipeDoctor
@PipeDoctor 5 ай бұрын
Will do!
Ultimate HVAC Hack Exposed: Balls Deep! They Went With the Lowest Bidder & Got Garbage
17:21
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 11 М.
They Ripped Him Off! Hacked Ductless HVAC System Don't Work: Can We Fix It?
11:16
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 11 М.
Who's spending her birthday with Harley Quinn on halloween?#Harley Quinn #joker
01:00
Harley Quinn with the Joker
Рет қаралды 18 МЛН
Random Emoji Beatbox Challenge #beatbox #tiktok
00:47
BeatboxJCOP
Рет қаралды 55 МЛН
Mia Boyka х Карен Акопян | ЧТО БЫЛО ДАЛЬШЕ?
1:21:14
Что было дальше?
Рет қаралды 9 МЛН
HVAC cooling season, rooftop unit p.m tips, tricks and what to look for
19:12
Stubborn Homeowner Won’t Replace! Ancient Rheem Central AC Outdoor Unit Not Cooling - It’s All Dead!
10:41
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 6 М.
Narrow Aisle Compact Forklift | MP001 by Diack Industries - Maximize Warehouse Space
15:34
Diack Industries - Material Handling Equipment
Рет қаралды 3,1 М.
Help! My HVAC Company Refuses Leak Search on Central AC System!
13:00
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 9 М.
Smart Meter Disaster!!
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 602 М.
Oversized Load And Nerves Of Steel In West Virginia Construction
36:56
Customer Fired Other Company! Can I Figure This No Cooling Out?
18:25
Jeff’s HVAC Adventures
Рет қаралды 571 М.
Burnham Gas Boiler EXPERT Shares Top Diagnosis Techniques
16:04
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 3,1 М.
Central A/C Maintenance Reveals Dying System Needing Massive Overhaul or Replacement
18:35
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 6 М.